Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Similar documents
Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

7 Lighting Technology

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

7 Lighting Technology

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sheet-Steel Light Fittings Series 6014 / 6414

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Terminal Boxes Series 8125

LED Linear Luminaire Series EXLUX 6402

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

7 Lighting Technology

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Linear Luminaire with LED Series EXLUX 6402/2

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Compact Sheet-Steel Light Fittings Series 6114

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Safety Switches Series 8537

Plug and Socket Devices SolConeX 16 A Series 8570

Compact Sheet-Steel Light Fittings Series 6114/1

Sheet Steel Emergency Light Fitting Series 6018

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Floodlight Series 6521/4

Load disconnect switch Series 8146/5-V11

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Floodlight LED Series 6525

Floodlight Series 6121

Floodlight LED Series 6525

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Floodlight LED Series 6125

Tank Inspection Lights Series 6122

Linear Luminaire for Fluorescent Lamps

7 Lighting Technology

Ex UPS standard Series 8265

7 Lighting Technology

Control Device System NEC Series ConSig 8040

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Portable Lamps Series HS6145, HSL145

Position Switches Series 8070/2

Position Switches Series 8060/2

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Position Switches Series 8074/2

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Control Buttons Series 8082

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Operating Instructions

Linear Luminaire with LED

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Control switch/load disconnect switch Series 8008

Control Buttons / Switches for Panel Mounting Series 8003

Metal Position Switch Series 8074

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Operating Instructions

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

10 Load and Motor Switchgear

Tubular Light Fitting with LED Series 6036

Linear fluorescent luminaire LED V-CG-S

Load and Motor Switches, Load-Break Switches Series 8549

Battery Boxes Series 8316

Load and Motor Switches, Load-Break Switches Series 8544

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Terminal Boxes Series 8146

Load and Motor Switches, Load-Break Switches Series 8544

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Easy and safe installation

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Pendant Light Fitting IEC

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVDL LED fitting - zones 21, & 22

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

A good connection. International approvals.

9 Control Equipment. Control Unit System Series ConSig 8040

K: bracket type. L: pole type

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

I Ex-safety switches I

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Transcription:

> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600 are useable for normal lighting, but also as group or centrally-supplied emergency light fitting. ATEX / IECEx Class I (NEC 505) (NEC 506) Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x For use in x For use in x x x x x WebCode 6600A Lighting /1

Selection Table Version Lamps Electronic ballast Order number Weight Number of lamps Lamp wattage W kg ECOLUX 6600 1 18 1 channel ECG 6600/521-8...-... 2.500 for use in Zones 2, 21 and 22 36 1 channel ECG 6600/541-8...-... 4.600 58 1 channel ECG 6600/561-8...-... 5.800 2 18 1 channel ECG 6600/522-8...-... 2.500 18 2 channel ECG 6600/522-9...-... 2.900 36 1 channel ECG 6600/542-8...-... 4.600 36 2 channel ECG 6600/542-9...-... 5.000 58 1 channel ECG 6600/562-8...-... 5.800 58 2 channel ECG 6600/562-9...-... 6.200 Order number supplement Through wiring Standard: without 6600/...-.0..-... Special: with 3 conductors 6600/...-.3..-... Special: with 5 conductors 6600/...-.5..-... Cable entry Standard: M25 x 1.5; 1 cable entry, 6600/...-..1.-... 2 stopping plugs Special: M20 or M 25 6600/...-..9.-... in moulded material or metal Specify on order Switching off Standard: without 6600/...-...0-... Special: with switch 8080, 2-pole 6600/...-...1-... Terminal strip Standard: terminal strip 8184, 4 / 6 mm 2 solid / finely stranded 6600/...-...-.1.. Special: WAGO 265 2.5 mm 2 6600/...-...-.2.. Number of terminals Standard: with 3 cores; L1 + N + PE 6600/...-...-..3. Special: with 5 cores; L1 + L2 + L3 + N + PE 6600/...-...-..5. Address module Standard: without 6600/...-...-...0 Special: 6448/11-02 (STAHL) 6600/...-...-...1 Note The light fittings are supplied without tubes and mounting accessories. These parts must be ordered separately. Explosion Marking IECEx Gas explosion Dust explosion Europe (ATEX) Gas explosion Dust explosion Certificates IECEx Gas explosion Dust explosion Europe (ATEX) Gas explosion Dust explosion Other certificates Ex na II T3/T4 Ex td A21 IP66 T * (6600/52., 6600/54.) Ex td A22 IP56 T * (6600/56.) * surface temperature see test certificate Zone 2: E II 3 G Ex na II T4 Zone 21: E II Ex td A21 IP66 T... C * Zone 22: E II Ex td A22 IP66 T... C * * surface temperature see test certificate IECEx BVS 07.0023X IECEx BVS 07.0023X Zone 2: DMT 01 E 085 Zone 21: DMT 01 ATEX E 086X Zone 22: DMT 01 ATEX E 085 USA (FM), Canada (CSA), Russia (CTB), Kazakhstan (JSC), Belarus (Gospromnadzor), Brazil (UL do Brasil), Shipping (GL)) /2 Lighting

Technical Data Electrical Data Rated voltage Rated current Power factor cos p Switch-off of the light Luminous characteristics Lamps Measures for light guidance Efficiency of light Luminous intensity distribution AC: 220 V (- 10 %)... 240 V (+ 10 %); 50 / 60 Hz DC: 154... 276 V at 230 V / 50 Hz; for light fittings version 1 lamp 2 lamps 18 W 36 W 58W cos p ) 0.96 capacitive; additional compensation not required optional On opening the diffuser when opening the fastening mechanism of one of the quick fasteners, voltage to ballast will be switched off all-pole; contacts are positively opening, reconnection when cover and quick fasteners are closed. Faulty lamp If lamp is faulty, power supply of lamps is switched off automatically by electronic ballast; when using a 2-channel-ECG power is switched off only to the defective lamp. Two pin-fluorescent lamps d 26 mm, socket G13 1 x 18 W 1 x 36 W 1 x 58 W 0.1 A 0.18 A 2 x 18 W 2 x 36 W 2 x 58 W 0.18 A 0.33 A 0.25 A 0.49 A Standard Wide beam, reflector painted white. Colour: signal white RAL 9003; prismatic structure for anti-glare in the diffuser sides. Special Additional reflector (easily mounted), broad deep-beam, aluminium anodized and semi-polished. 08258E00 Version 1-lamp, without reflector 1-lamp, with reflector Accuracy class acc. to LitG B21 B31 08257E00 Environmental Conditions Ambient temperature 08259E00 Version 2-lamp, without reflector 2-lamp, with reflector Accuracy class acc. to LitG B21 B31-20... + 55 C (18 W / 36 W without trough wiring) - 20... + 45 C (58 W und 18 W / 36 W with trough wiring) 08257E00 Lighting /3

Technical Data Mechanical Data Type of IP66 (IP64 when using breathing gland 8162) IP56 at 58 W I(with internal PE connection terminal) Protection class Material Enclosure Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Lamp cover Polycarbonate; protective paint possible Gasket Polyurethane-gasket foamed into diffuser Quick-acting locks Polyamide, glass fibre reinforced, black / white Assembly parts Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Cover fixing Quick fasteners to open with screw-driver; cover hinged for access. Assembly / Installation Mounting 2 x M8 inserts in housing Mounting grooves in housing to accommodate bracket fitting and ceiling rails for variable light installation. Variable mounting distances of light fittings; see dimension drawings Cable glands 1 x cable gland 8161, M25 x 1.5; cable dia. range: d 7... 17 mm 2 x stopping plugs 8290, M25 x 1.5 Entry parts in moulded plastic (8161 / 8290): M20 Metal glands: M20; M25; Metal cable gland earthing via metal adapter plates Connection type Standard Spring cage terminal clamping area: max. 2 x 2.5 mm 2 or Terminal block with screw terminals in polyamide also with additional connection points for through wiring cable dia range: max. 2 x 6 mm 2 (single core) max. 2 x 4 mm 2 (flexible) numbers of terminals: 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) Special Screw terminals clamping area: 2 x 4 mm 2 (fine wire / single wire) 3 pole (terminal marking: L1 + N + PE) Installation notes Looping through of There are 2 M25 x 1.5 cable entries on the connection side for looping through of connection cables cable (entry and exit on one side). Through wiring Fittings can be supplied with internal through-wiring. Entry and exit holes for connection cables are positioned on opposite sides. A through-wiring kit can be fitted after manufacture (see accessories). Terminals: See technical data top Wiring cross-section: 2.5 mm 2 for max. 16 A Monitoring module Function Monitoring and switch module for central battery systems in accordance to VDE 0108: The module is capable of performing the single monitoring of light fitting and the combined circuit of normal and emergency light fittings. The module offers the following functionality: Control of the light fitting (ON / OFF) and function testing Within one circuit it is possible to operate up to 20 modules via a coding switch Each single device within a circuit can be programmed as: permanent light, stand-by light and switched light Mixed operation of modules in one circuit possible Input voltage (Input between L+ and N-) U N U DC Control input (between L and N) U N 230 V (+ 10 % / - 15 %), AC, 50 Hz 175... 275 V DC 230 V (+ 10 % / - 15 %), AC, 50 Hz Connection power (output) P 4... 100 W Ambient temperature limit Dimensions T a (Modul) - 10... + 50 C L x W x H = 95 x 40 x 32 mm /4 Lighting

Accessories and Spare Parts Designation Illustration Description Order number Weight Fluorescent lamp 04936E00 Two-pin cap d 26 mm Light colour: universal white 18 W 1350 Im kg 108952 0.100 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Diffuser cover 05329E00 for light fitting 18 W 124890 0.500 for light fitting 36 W 124897 0.860 for light fitting 58 W 124904 0.800 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 Ballast Mounting kit for through wiring Reflectors 10809E00 05893E00 05503E00 05324E00 1 x 18 W 1-channel 106599 0.270 2 x 18 W 1-channel 106596 0.406 1 x 36 W 1-channel 106598 0.260 2 x 36 W 1-channel 106595 0.420 1 x 58 W 1-channel 106597 0.310 2 x 58 W 1-channel 106594 0.410 For later installation into standard-light fitting DV3, tension clamp terminals 3 x 2.5 mm 2, max. 16 A terminal marking: L1 + N + PE 18 W 124925 0.300 36 W 124927 0.300 58 W 124929 0.300 DV5, tension clamp terminals 5 x 2.5 mm 2, max. 16 A terminal marking: L1 + L2 + L3 + N + PE 18 W 124919 0.300 36 W 124921 0.300 58 W 124923 0.300 DV3, screw terminals 3 x 2.5 mm 2, max. 16 A terminal marking: L1 + N + PE 18 W 124912 0.400 36 W 124915 0.400 58 W 124917 0.400 DV5, screw terminals 5 x 2.5 mm 2, max. 16 A terminal marking: L1 + L2 + L3 + N + PE 18 W 124895 0.400 36 W 124902 0.400 58 W 124909 0.400 for later installation, broad deep beam For 1-lamp light fittings 18 W 117128 0.082 For 1-lamp light fittings 36 W 117137 0.172 For 1-lamp light fittings 58 W 117150 0.218 for lights with two lamps 18 W 117098 0.265 for lights with two lamps 36 W 117115 0.234 For 2-lamp light fittings 58 W 117145 0.290 Lighting /5

Accessories and Spare Parts Designation Illustration Description Order number Weight kg Adapter plates for earth continuity when using metal glands; 1 x M20 x 1.5 1 piece 115815 0.070 05755E00 1 x M25 x 1.5 1 piece 1 x NPT 1 / 2 1 piece 1 x NPT 3 / 4 1 piece 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 2 x NPT 1 / 2 1 piece 115818 0.070 115821 0.070 115824 0.070 115826 0.060 115828 0.060 115829 0.060 Lamp-holder Lamp holder for two-pin cap lamps G 13 107275 0.008 Mounting rail 05888E00 for a variable mounting distance of 1 pair 124894 0.210 05895E00 Mounting clamp bracket Mounting bracket mounted on the mounting rail for a variable mounting distance of 1 pair 124901 0.300 Ring bolts 05896E00 M8, direct mounting in insert nuts, 1 pair 115736 0.120 Wall-mounting bracket 05378E00 to mount the lamps as side-entry lamps using a tube with a length of 1300 mm, d 42 mm (for pipe clamp R 1 1 / 2 ) 109281 6.000 Ceiling mounting bracket 05460E00 for ceiling suspension of the lamp, 1 pair 124908 0.230 Pipe clamps Mounting set,,grid cable rack 05897E00 09402E00 with mounting rail for a variable mounting distance; Material: stainless steel R 1 1 / 4 (d 42 mm) 124913 1.140 R 1 1 / 2 (d 48 mm) 124891 1.160 R 2 (d 60 mm) 124898 1.300 for grid cable racks, with a cable diameter of 6 mm; 124905 1.560 with mounting rail for a variable mounting distance; Material: stainless steel Ceiling and wall-mounting bracket 04361E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 1 pair 124910 1.150 05898E00 /6 Lighting

Accessories and Spare Parts Designation Illustration Description Order number Weight kg Cable gland in moulded material, series 8161 05864E00 8161/5-M20-13 1 piece 138518 0.012 8161/5-M20-13 50 pieces 138454 0.600 8161/5-M25-17 1 piece 138520 0.020 8161/5-M25-17 50 pieces 138456 0.850 Stopping plug in moulded material, series 8290 8290/3-M20 x 1,5 1 piece 143522 0.005 04840E00 8290/3-M20 x 1.5 100 pieces 143543 0.600 8290/3-M25 x 1.5 1 piece 143524 0.007 8290/3-M25 x 1.5 100 pieces 143544 0.800 Breathing gland 05703E00 for installation in lights; in moulded material; without counter nut Thread: M25 x 1.5 1 piece 138573 0.010 Thread: M25 x 1.5 20 pieces 138576 0.200 Lighting /7

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Dimensions Light fitting 18 W 36 W 58 W L1 700 1310 1610 L2 1) 400 800 800 L3 2) 340... 460 680... 920 795... 1030 1) Fixed mounting distance 2) Variable mounting distance Light fittings ECOLUX 6600, 18 W, 36 W, 58 W 04824E00 Pipe clamp 04717E00 Mounting set grid cable rack 04822E00 Ceiling- and wall-mounting bracket 04716E00 Ceiling mounting bracket 04833E00 04823E00 04715E00 04834E00 Wall mounting bracket for pole-mounting version Ring bolt Mounting clamp bracket Installation accessories We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /8 Lighting