DART Ware Wash Speed Control

Similar documents
DEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)

Trapper Drain Maintenance/Odor Control Chemical Dispensing

DEMAMaster TM DM-811 Series Installation Manual

DEMA Nitro for Europe Ware Wash Chemical Dispensing

DEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.

Trident Laundry Chemical Delivery System

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

DEMA SQUIRT DRAIN UNIT

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

Drain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing

BIOACTIVE SOLUTIONS AC DRAIN STATION

Spray Clean 606T-2 Installation Instruction

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

DEMA Pro-Fill II Sink Dispenser

DEMA Pro-Fill I Sink Dispenser

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

DEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET

Spray & Foam Dispenser Item #

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

I Button Chemical Dispenser. Overview. Installation Instructions

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

665 Series Dispenser. Metering tip kit

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

PeroxiDraw Dispenser

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

Caution! Pg. 1 of 5 I-932

D EMA TWO-STAGE INJECTOR MODELS 233, 234A, 236A, 236-8, 238, AND 2312 INSTALLATION INSTRUCTIONS FIGURE 3 FIGURE 2

Certo Chemical Dilution System

Items # and #

SAFETY INFORMATION & INSTRUCTION MANUAL

Intended Use: Explanation of Signal Word Consequences

910 BHF OWNER S MANUAL. Pg. 1 of 9

ILCS EDGE System Installation Manual

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

Cleaning & Sanitizing Instructions

BLAST-TEC PRO - ROTATING TURBO NOZZLES

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

Owner s Manual FS-10/FreshSpa

Reference Manual FM-200 Series

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

INSTALLATION INSTRUCTIONS TOP MOUNT SINK CH366

VSP SERIES Installation, Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS

GW-120 Bar Glass Washer

WARRANTY POLICY FOR LD SERIES LABEL DISPENSERS REPAIR POLICY

MULTIPOSITION AIR CYLINDER

INSTALLATION INSTRUCTIONS. PART NUMBER C (Gun Metal Gray Finish) 2016 HYUNDAI TUCSON 1.6 Turbo

INSTALLATION INSTRUCTIONS UNDERMOUNT SINKS

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

DWV-PVC PVC DRAIN, WASTE & VENT FITTINGS PRODUCTS PRICE LIST INCLUDES HVAC PRODUCTS. 07 DWV- PVC through 8 22 HVAC

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

PACIFICA Shower Cabin Installation Instructions

Installation Instructions Model: AB Single-lever Pull-down Spray Faucet

SCHEDULE 80 PVC PRESSURE FITTINGS L80P EFFECTIVE JULY 1, 2017 REVISED PRODUCTS PRICE LIST INCLUDES: SCHEDULE 80 PVC 1/4 TO 12

INSTALLATION INSTRUCTIONS

I n j e c t o r s. Different Models. Applications Fertigation Chlorination and acidification Water additives ph and EC control

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

INSTALLATION INSTRUCTIONS PART NUMBER:

INSTALLATION INSTRUCTIONS PART NUMBER WR (Wrinkle Red Finish)

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Installation Instructions Model: AB Single-Lever Pull-out Kitchen Faucet

INSTALLATION INSTRUCTIONS PART NUMBER: C (Gun Metal Gray Finish)

INSTALLATION INSTRUCTIONS PART NUMBER:

BOSTON TOWER MERCHANDISER ILLUMINATION KIT (P/N ) INSTALLATION INSTRUCTIONS

SCION xb L4-2.4L

DP-139 PUMP DIMENSIONS

INSTALLATION INSTRUCTIONS PART NUMBER:

Discount Codes 07 DWV-PVC through 8 22 HVAC DWV - PVC. PVC Drain - Waste Vent Fittings. Includes: DWV - PVC - through 8 HVAC.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PART NUMBER C (Gun Metal Grey Finish)

Transcription:

DART Ware Wash Speed Control Overview Simple and value best describe the DEMA Dart. The system is extremely easy to setup and program. The Dart is suitable to deliver detergent, rinse aid and sanitizer to small low volume dish machines. The Dart is perfect for single rack dish machines such as door or under the counter. Warnings Installation of DEMA products must meet all applicable electrical codes and regulations established by national, city, county, parish, provincial or other agencies. It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation. For questions, contact a certified electrician. ALL ELECTRICAL POWER MUST BE TURNED OFF TO THE DISPENSER AND TO THE APPLIED MACHINE. All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee. ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS. I-1064 Page 1 of 5

Nomenclature & Specifications DART.DEJ Pump Connections J ¼ Compression Nut (for ¼ OD LDPE or Vinyl tubing) C Cone Compression Nut (for ¼ OD x 1/16 wall soft tubing) Squeeze Tube Material (pump tube) E EPDM S Silicone P Supertube (PVC) Application Kit D Detergent Kit R Rinse Kit S Sanitizer Kit X General Kit (no bulk head or check valve hookup fittings) Detergent Kit 81.260.1 1 Detergent Bulk Head Fitting (mounts in dish machine wash tank) 24.10.11 1 ¼ x 1/8 x 16FT Vinyl Tubing Rinse Kit (For ¼ Compression Version DART.REJ) 904.8T 1 Rinse check valve 100.12.SV1 1 ¼ x 1/8 x 16FT Vinyl Tubing Sanitizer Kit (For ¼ Compression Version DART.SEJ) 904.8KY 1 Sanitizer check valve (Kynar, compatible with chlorine) 100.12.SV1 1 ¼ x 1/8 x 16FT Vinyl Tubing DART.X Kit 24.10.11 1 ¼ x 1/8 x 16FT Vinyl Tubing I-1064 Page 2 of 5

Electrical Specifications Main Power: 115/230VAC 50/60Hz 0.5A Factory set to 230VAC (see page X, how to change to main power setting) Pump Performance 1.3 oz/minute (40 ml/minute) MAX 40 PSI MAX Dimensions & Weight 2.85lbs (1.3Kg) Shipping weight ELECTRICAL INSTALLATION: All installations must be in accordance with city, county, parish, state, or provincial electrical codes and be performed by a certified electrician. For questions, please contact a local licensed electrical contractor. 1. All electrical power must be turned off to the dish or cleaning machine and any other circuit that is to be used for this installation. Lockout and tag procedures must be observed when installing this device. Never open the Olympian enclosure while power is applied. Signals may be active from the dish or cleaning machine, even with Olympian power turned off. Use appropriately rated insulated wiring, electrical fixtures, and other materials Power selection switch that meet all applicable electrical and building codes. 2. O-DDV Controls Only: This control has a switch to select the proper line voltage. The unit is factory set to 230VAC. To change the voltage to 115VAC, remove the back of the control. Move the switch from 230VAC to 115VAC as shown in Figure 1. Reinstall the back cover. WARNING: This must be done before connecting power to the unit. 3. Connect to the appropriate power source. Wiring Color Code Brown Wire Blue Wire Green/Yellow Wire Line Common Ground Figure 1. Input Voltage Switch I-1064 Page 3 of 5

TUBING INSTALLATION: 1. Install tube stiffener as shown in Figure 2. 2. Place stiffened tube into chemical container. 3. Cut tubing to the appropriate length. Attach tubing to the pump inlet. 4. Attach outlet tubing to pump outlet and to dish machine using the bulk head or check valve fittings that are supplied with the kit. SETTING SPEED: 1. Apply power. 2. Remove the cover in Figure 3. 3. Adjust the potentiometer until the pump runs at the desired speed. 4. Replace the Olympian cover. Figure 2 Speed adjustment potentiometer Figure 3 Replacement Parts Item DEMA P/N Qty Description 1 81-226-6 1 Dial Speed Control Pump Assembly 2 1 Cover with Label 3 1 Olympian Control (no pump included) 4 81-223-1 1 Mounting Bracket Pump Replacement Parts Item DEMA P/N Qty Description 1 81-240-2 1 Pump Bore 2 81-231-1 1 Squeeze Tube Assembly 3 81-219-1 1 Roller Block Assembly - Rinse 4 81-241-2 1 Pump Base 5 80-67-13 2 Compression Fittings I-1064 Page 4 of 5

Return Policy: No merchandise may be returned for credit without DEMA Engineering Company s written permission. Return Merchandise Authorization (RMA) number required in advance of return. Warranty: DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse or misapplication. Rubber and synthetic parts such as O -rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty will be void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge. F.O.B. factory DEMA assumes no liability for damages. Return merchandise authorization number to return units for repair or replacement must be granted in advance of return. DEMA Engineering Company 10020 Big Bend Blvd. St. Louis, MO 63122 (800) 325-3362 or (314) 966-3533 www.demaeng.com I-1064 Page 5 of 5