Installation Guide Thermal Conductivity Detector Accessory 19232E

Similar documents
Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Nickel Catalyst Tube Accessory 19205A

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Installing a Purged Packed (PP) Inlet

Installing a Cool On-Column Inlet

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Agilent G1554A On-Column Capillary Inlet with EPC

Installing a PTV Inlet

Installing the CO 2 Cryogenic Oven Cooling Kit

Installing a PTV Inlet

Installing an Auxiliary Pressure Control Module

Installing an Auxiliary Pressure Control Module

Installing a Purged Packed Inlet

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Installation Guide. Agilent 7683 Automatic Liquid Sampler

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Installing the 6850 Direct Valve Column Connector Kit

Installing the Flame Ionization Detector EPC Flow Control Manifold

Agilent G3510A/G3511A Multimode Inlet

29 Installation Step 1. Unpacking the GC Cable diagrams Step 2. Placing the GC system on the benchtop Step 3. Turning the power on

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Agilent G2738A Upstream Capillary Interface

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

HP 6890Series Gas Chromatograph. Installation Guide. Flame Ionization Detector. Accessories HP G1561A HP G1562A HP G1591A HP G1598A

Operation Quick Reference Guide

Installation Instructions

Model Fixed Rack-Mount Kit

Switching DC Power Supply

Dionex AS-DV Autosampler Preventive Maintenance Procedure

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Exchange of rollers from the XTS-Mover

INSTALLATION INSTRUCTIONS

Fiber Optic Illuminator. Model 21AC Model 21DC

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Installation Instruction

Agilent G5632 Valve Kit Instructions

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Installing the G2743A/G2745A Valve Actuator Kits

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL

Deans Switch Microfluidics

Agilent InfinityLab Quick Change Valve G4235A Instructions

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Operating Manual. Agilent 7673 Automatic Liquid Sampler

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

PNA FISH Workstation Operating Instructions

SAM S KIOSK & SET ASIDE USER MANUAL INSTALLATION & MAINTENANCE

Universal Splice Tray Installation Instructions

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

Agilent G4239C Valve Kit - Instructions

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Agilent Online-SPE Direct Inject Kit G4744A

Carousel Unit User Manual Replacing the Check Stand Motor

PET UNIT DOSE CABINET

Agilent 6890 Gas Chromatograph

Agilent G3348B Flame Photometric Detector

Model 700 Microarray Oven

INSTALLATION INSTRUCTIONS

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

Hot Injection Adapter Kit - Installation Guide

LV Capacitor CLMD03 Power Module Instruction manual

Replacing the Batteries in the Fortress LI 660

Installing the Switch

IMPORTANT SAFETY INSTRUCTIONS

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Agilent G2647A (Single) and G2648A (Dual) Flame Photometric Detector Update Kits

Megohmmeter Test Probe

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Agilent Valve Kit G4231A/B/C and G4232B/C/D

HP Modular Cooling System 200/100 Options Installation Guide

TCD (H2) EFC INSTALLATION

RE22 Airbag Systems, Side

Triple Output Power Supply

Installation Instructions Studio Makeup Station

BATTERY REPLACEMENT GUIDE

CONSOLE MANAGEMENT CONTROLLER

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

CoolWave 2 Phase Control Board and Cable Replacement Kit

P&G MANUFACTURING INC.

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

Installation Instructions

Agilent G2333B (Single) and G2334B (Dual) Flame Photometric Detectors

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

BMW N54 Baffled Oil Catch Can, CCV Side, PARTS LIST AND INSTALLATION GUIDE

Transcription:

Installation Guide Thermal Conductivity Detector Accessory 19232E

Agilent Technologies 2000 All Rights Reserved. Reproduction, adaptation, or translation without permission is prohibited, except as allowed under the copyright laws. Part number 19232-90127 First Edition, DEC 2000 Replaces Part No. 19232-90120 Operating and Service Manual. HP is a registered trademark of Hewlett-Packard Co. Printed in USA Safety Information The Agilent Technologies Thermal Conductivity Detector meets the following IEC (International Electrotechnical Commission) classifications: Safety Class 1, Transient Overvoltage Category II, and Pollution Degree 2. This unit has been designed and tested in accordance with recognized safety standards and designed for use indoors. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. Whenever the safety protection of the Agilent 19232 has been compromised, disconnect the unit from all power sources and secure the unit against unintended operation. Refer servicing to qualified service personnel. Substituting parts or performing any unauthorized modification to the instrument may result in a safety hazard. Disconnect the AC power cord before removing covers. The customer should not attempt to replace the battery or fuses in this instrument. Safety Symbols Warnings in the manual or on the instrument must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions violates safety standards of design and the intended use of the instrument. Agilent Technologies assumes no liability for the customer s failure to comply with these requirements. WARNING A warning calls attention to a condition or possible situation that could cause injury to the user. CAUTION A caution calls attention to a condition or possible situation that could damage or destroy the product or the user s work. Sound Emission Certification for Federal Republic of Germany Sound pressure Lp < 68 db(a) During normal operation At the operator position According to ISO 7779 (Type Test) Schallemission Schalldruckpegel LP < 68 db(a) Am Arbeitsplatz Normaler Betrieb Nach DIN 45635 T. 19 (Typprüfung) Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 USA

Installing the Thermal Conductivity Detector Accessory 19232E Preparing the GC WARNING Hazardous voltages are present in the instrument whenever the power cord is connected. Avoid a potentially dangerous shock hazard by disconnecting the power cord before working on the instrument. 1. Set the main power line switch to the off position. Red O visible OFF ON 2. Disconnect the power cable from its receptacle. 3. Allow time for the oven and heated zones to cool. 4. When the heated zones are cool, turn off all gas supplies at the source. Copyright 2000 Agilent Technologies Printed in USA Dec 2000 Agilent Part No. 19232-90127

Preparing the GC 5. At the bottom of the inlet or detector to be removed, inside the column oven, remove the column and hardware associated with the inlet or detector (liner, column/liner nuts, ferrules, makeup gas adapter, etc.). 6. Remove the injection port cover by grasping its back edge and lifting it upward. If an autosampler is installed, the injection port cover will not be present. Injection port cover Top cover Lid shaft Press here to free cover 1/4-inch screw and washer 2

Preparing the GC 7. If an autosampler is installed on the instrument, it will be necessary to remove it and its mounting bracket to allow removal of the left side cover. a. Remove the autosampler tray from its mounting bracket by simultaneously lifting and turning the two tray locks that hold it in position, then sliding the tray away from the instrument. b. Lift the autosampler tray from its mounting bracket and set it aside. c. Remove the autosampler bracket by removing the six screws securing it to the instrument. 8. Remove the two screws securing the left side panel along its bottom edge. Left side panel Screws 9. Slide the left side panel towards the rear of the instrument and lift. 3

Preparing the GC 10. Remove the electronics carrier top cover by grasping it at the rear and lifting upwards until its catch releases, then pulling it towards the rear of the instrument. Electronics carrier top cover 11. Remove the right side panel by removing four screws: two each along its top and bottom edges. Screws Screws Right side panel 4

Preparing the GC 12. Remove the back cover of the instrument by removing four screws and sliding the cover off the rear of the instrument. Screws Screws 5

TCD detector Switching valve Makeup gas line Flow module Caution The insulation on the GC is made of refractory ceramic fibers (RCF). Ventilate your work area. Wear long sleeves, gloves, safety glasses, and a disposable dust/mist respirator. Dispose of insulation in a sealed plastic bag. 1. If present, remove the cover plate from the detector mounting location and the insulation below it. 2. Remove the flow-control label plate in the detector A or B location. The plate is glued in place and is removed by pushing it firmly through 6

openings in the back of the flow panel to get it started, then pulling it free. Flow control plates A position B position 3. Place the provided self-adhesive TCD flow plate in the space where flow-control components for the detector are to be installed. 4. There are two mounting studs on the back of the main flow panel for installing the detector flow module. Place the flow module assembly on 7

the studs. Secure it with an M4, 1-3/4 inch screw through the center hole of the flow module. TCD flow module Reference Makeup Mounting screw 5. Route the makeup gas tubing from the flow module across the top of the oven to the detector area. Use the metal tube retaining clips located near the rear of the oven to hold the tubing in place. Makeup gas tubing 8

6. Install the TCD switching valve and bracket immediately to the rear of the detector mounting area and secure with two M4 screws. Switching valve and bracket 7. Insert the makeup gas tube through the hole where the detector is to be mounted and position the tubing in the slot located in the oven ceiling liner. Slot in oven liner, position B Slot in oven liner, position A 9

8. Remove the plastic covers from the sensors and insert the heater and sensor cartridges into the detector block. Install the second sensor (Delta-T) into the block. Heater Temperature sensor Delta-T sensor 9. Install the detector through the top of the oven and secure with two M4 screws. WARNING The insulation on the GC is made of refractory ceramic fibers (RCF). Ventilate your work area. Wear long sleeves, gloves, safety glasses, and a disposable dust/mist respirator. Dispose of insulation in a sealed plastic bag. 10. Use the insulation removed (tear apart as needed) to fill in the area around the detector. 10

11. Place the top insulation on the detector and align the slot in the insulation as shown below. Slot for filament and Delta-T leads Slot for heater/ sensor wires Slot toward rear for position B Slot toward front for position A 12. Install the thermal cover and route the filament leads, Delta-T sensor leads, and heater/sensor wires through the appropriate slots in the cover. Secure the cover with two M4 screws. Caution Board components can be damaged by static electricity. Use a properly grounded static control wrist strap when handling the TCD board. 11

13. Install the TCD signal board in the position (slot) on the main circuit board corresponding to the detector location. B A 14. Gently twist the filament leads together. Route the filament and the Delta-T sensor leads through the notch in the mainframe to the TCD 12

circuit board. Then route the switching valve leads through the hole below the notch to the circuit board. Switching valve leads Filament and Delta-T sensor leads Heater/sensor wires 15. Apply the TCD label on the electronics carrier across from the detector. TCD label B FILAMENT LEADS TEMP SENSOR LEADS GAS TYPE N 2, Ar He, H 2 A SEE MANUAL TO DISCONNECT Caution Board components can be damaged by static electricity. Use a properly grounded static control wrist strap when handling the TCD board. 13

16. Insert the TCD filament leads into the first two sockets in the green connector. To insert the lead, open the socket by inserting the blade of a small screwdriver into the slot adjacent to the socket being connected. 17. Insert the Delta-T sensor leads into the remaining two sockets on the board. Filament leads Delta-T sensor leads 18. Connect the switching valve leads (yellow and black) to the J24 connector in the TCD signal board. Route the leads through the round hole in the mainframe. 14

19. Connect the sensitivity control lead from the TCD signal board to the corresponding detector position on the main circuit board (P16 = DET A, P17 = DET B). P17, Detector B P16, Detector A J24, Switching valve 20. Route the detector heater/sensor leads over the switching valve bracket to the rear of the instrument, then through the plastic tray to the main circuit board. Heater and sensor wires must be connected to matching heated zones (DET A sensor on P7 and DET A heater on J9 or DET B sensor on P7 and DET B heater on J9). Connect the sensor leads (white) to P7. Connect the heater leads (red) to J9. 15

MAIN CIRCUIT BOARD Position 3 & 4 = Det A position Position 5 & 6 = Det B position White P7 sensors J9 heaters Red Position 9 & 10 = Det A position Position 7 & 8 = Det B position 21. Reinstall the panels and covers. Reconnect the instrument power cord and restore power. 22. Make gas connections to the back of the flow module per the Getting Started Guide (for the 4890) or the Site Prep/Installation (for the 5890) manual. 23. Install a column in the detector makeup gas adapter as described in your GC Operating Manual. 24. Establish your gas flows and run a test chromatogram as described in your GC Operating Manual. 16

Printed on recycled paper. This product is recyclable. Agilent Technologies, Inc. Printed in USA Dec 2000 19232-90127