GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

Similar documents
GTFM V. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5026 Revised: 09/11/2013

DART. Operation / Installation Manual. Digital Analog Remote Transducer. Computer Weld Technology, Inc. Manual Part Number: A8M5015 Revised: 9/28/2004

Installation and Operation Instructions DLP Series

To ensure proper installation, digital pictures with contact information to before startup.

2100 Turbine Flow Sensor

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Application Engineering

Application Engineering

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

3200NT Timer Service Manual

Iron Gate Air Pump System Manual

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

ValveMate 7000 Controller Operating Manual

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Carbon Monoxide Transmitter

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

Induction Power Supplies

Signet Pressure Transmitter

Abstract. GLV Systems Test Plan 1

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

HPC40 Series Calibrator psi

Tracer VM with User Interface

Signet Pressure Transmitter

L5000 Plus. Installation & Setup Guide

USERS MANUAL MCD REMOTE OPERATOR

OEM Manual. 4042SA Leak Detecting Spill Alarm Instruction manual

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Gate & Door Controller with LCD and Intelligent Technology

Product Guide: Series III Pump Control Board Set (RoHS)

INSTALLATION/OPERATING INSTRUCTIONS TSC

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Installation Instructions & Users Manual

Tracer VMA with AutoReg

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Application Engineering Europe

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

INSTRUMENTATION & CONTROL

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element

Model 8000XL OPERATOR MANUAL

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Features and Benefits. Control Features

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

TRAC-3 TENSION READOUT AND CONTROL

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

PKG-341-MBC08-PS-CBL System Diagram and Specifications

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

Flight Systems. Replacement for KASSEC DESCRIPTION

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

CENTRIFEEDER ELECTRONICS

GSC300 Auto Start Engine Controller

EZ-TRAC Digital Tension Readout and Control

GSC300 Auto Start Engine Controller

Hydro-Flow Model 2200 Installation and Operation Guide B

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Section 55 Chapter 6

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Model Q45H/ Residual Chlorine Monitor...

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

OV4 Installation Manual

Installation and Operations Manual

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Dissolved Oxygen Measurement System with Air Blast Cleaner

Installation Instructions

LTX RF LEVEL SENSOR. Instruction Manual

Model 7400 OPERATOR MANUAL

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

Combined Ventilation Controller RVWS-T-224HA

PowerView PV380-R2 Mechanical Configuration

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

OPERATOR S MANUAL StudPro LiteXI Pin Welder Stud Welding Products, Inc

AFD-280U Parts List AFD-280U. (350 gm) (450 gm) (700 gm)

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

OPERATING INSTRUCTION: DGC-6D/6D1I

Rosemount 8750WB Magnetic Flowmeter System

CONTROLLERS & SPECIAL VALVES

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Automotive Application ET01 Software Revision A 12/06

wd-2

Programmable 8 Channel Injector Driver Module

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Transcription:

Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation Manual Manual Part Number: A8M5010 Revised: June 26, 2008

Table of Contents 1.0 OVERVIEW... 1 1.1 SYSTEM REQUIREMENTS... 1 1.2 BENEFITS... 1 1.3 FEATURES... 1 1.4 MECHANICAL SPECIFICATIONS... 1 1.5 SENSOR SPECIFICATIONS... 2 1.6 MODELS... 2 2.0 INSTALLATION... 3 2.1 OPTIONS... 3 2.2 GAS LINE HOOKUP... 3 2.3 CABLE HOOKUP... 3 2.4 GAS FLOW LIMITS... 3 2.5 GAS FLOW VOLUME... 4 3.0 OPERATION... 5 3.1 FIRMWARE VERSION... 5 3.2 LIMITS... 5 3.3 PARAMETERS... 5 3.4 BATTERY SPECIFICATIONS... 6 4.0 SETTING GAS FLOW CONTROL LIMITS... 7 4.1 DESCRIPTION... 7 4.2 SETUP... 7 5.0 GAS FLOW SURGE "P" MEASUREMENT... 8 5.1 DESCRIPTION... 8 6.0 GAS FLOW USAGE "U" MEASUREMENT... 9 6.1 DESCRIPTION... 9 6.2 SETUP... 9 7.0 GAS CYLINDER LOW VOLUME MEASUREMENT... 10 7.1 DESCRIPTION... 10 7.2 SETUP... 10 8.0 GTFM CONNECTOR PIN ASSIGNMENT... 11 8.1 AUX CONNECTOR... 11 8.2 RELAY CONNECTOR... 11 9.0 CHANGING THE BATTERY... 12 10.0 MODEL SPECIFICATIONS... 13 10.1 120 VAC PORTABLE GTFM IV SYSTEM P/N: A0A0032... 13 10.2 240 VAC PORTABLE GTFM IV SYSTEM P/N: A0A0033... 14 10.3 ADM IV GTFM IV SYSTEM P/N: A0A0064... 15 10.4 120 VAC IN-LINE GTFM IV SYSTEM P/N: A0A0036... 16 10.5 240 VAC IN-LINE GTFM IV SYSTEM P/N: A0A0037... 17

10.6 GTFM IV RELAY CABLE P/N: A3W0259... 18 10.7 GTFM IV AUX CABLE P/N: A3W0260... 19 10.8 GTFM IV ENCLOSURE ASSEMBLY P/N: A3W0179... 20 10.9 GTFM IV MOUNTING DIMENSIONS... 22

1.0 Overview 1.1 System Requirements The GTFM IV Gas Turbine Flow Monitor, is designed to permit the user to precisely measure the flow rates of the weld shielding gases. WARNING DO NOT USE WITH ANY FLAMMABLE GASES. The unit comes in both "portable" and "inline" models and is available in English or Metric versions. The portable version can be used to check the gas flow rates directly at the welding torch. The unit is battery powered, which allows it to be carried throughout the shop. This version is ideal for use by maintenance personnel to correctly set and verify shielding gas flow rates at the welding torch. 1.2 Benefits The "in-line" version is designed to be permanently installed in a welding fixture to continuously monitor the gas flow rate. When used in this manner the GTFM can provide "sure-flow" gas testing by setting upper and lower control limits for the user defined gas flow rates. An internal fault relay can be used to warn or interrupt the welding process if an out-of-limits condition is detected. 1.3 Features Some of the features contained in the unit are the capability to limit test, provide an accumulated gas usage and peak flow rates as well as displaying on going gas flow rates. The unit also provides an analog output voltage representing measured gas flow rates. 1.4 Mechanical Specifications Dimensions 3-1/4"W x 1-3/4"H x 5-3/8 L (85 mm W x 45 mm H x 127 mm L) Weight 23 oz. (652 gm) Pipe Fittings 3/8" NPT with 3/8" hose barb fittings 1

1.5 Sensor Specifications Measurement Range 5-255 CFH (2-120 LPM) Display Resolution ±1 CFH (± 1 LPM) Accuracy ±2 % of full-scale ±1 digit Operating Pressure 50-PSI maximum (344 KPA) Fault Relay Output: N.O. Dry Contact Closure Relay Rating 120 vac @ 0.5 amps non-inductive, 24 vdc @ 1.0 amps noninductive Analog Sensor Output: 0-2.55 vdc @ 10 ma. Analog Scaling 0.01 vdc = 1 CFH (.01 V = 1 LPM) Power Requirement 10-28 vdc @ 100 ma. Operating Temperature 20-140 F (-7-60 C) Battery Charger 120 vac 60 hz @ 300 ma (220 VAC 50 hz @ 300 ma) Battery Life Approximately 2 hours with full charge (English / Metric units of measurement available) Note: Specifications subject to change without notification. 1.6 Models The following models are covered in this document: Part No. A0A0032 A0A0033 A0A0064 A0A0036 A0A0037 Description 120 VAC Portable GTFM IV System 240 VAC Portable GTFM IV System ADM IV GTFM IV System 120 VAC In-Line GTFM IV System 240 VAC In-Line GTFM IV System 2

2.0 Installation 2.1 Options The GTFM can be used as a portable or in-line gas flow monitor. If the unit was purchased as a portable monitor, it will be equipped with a rubber gas cone. The cone is designed to fit standard torch gas cups and allows the GTFM to measure the actual gas flow at the torch. To install, simply press the GTFM gas cone onto the welding torch gas cup. Make sure that the cone is fitted snugly to the gas cup. 2.2 Gas Line Hookup The GTFM may also be installed into the gas line and used to permanently monitor the gas-flow rate. This model is supplied with barbed 3/8 ID hose fittings. The sensor will accept any 3/8 NPT pipefitting. The user may hard plumb the sensor if desired. DO NOT USE PIPE DOPE OR TEFLON TAPE ON THE PIPE FITTINGS. The sensor should be located between the welding-gas solenoid and the torch. DO NOT INSTALL THE SENSOR ON THE INLET SIDE OF THE GAS SOLENOID. If the sensor is installed on the inlet pressure side of the gas solenoid, the maximum operating pressure (50 psi) of the transducer may be exceeded. 2.3 Cable Hookup WARNING: Do not over tighten fittings as it may twist the sensor out of position. The GTFM provides an analog voltage, which will represent gas flow. This analog voltage can be monitored by using the Auxiliary Cable and connecting the plug to the "AUX" connector on the bottom panel. The output voltage will have the following relationship: 2.55 volts = 255 cfh or.01 volts/cfh The output impedance of this signal is 100 ohms and can source 2 milliamps of current. The analog-interface cable can also be used to supply power to the GTFM. The power requirement is (10-28) vdc @ 100 ma. 2.4 Gas Flow Limits The GTFM can be used to test for High/Low gas flow limits. An internal fault relay will be set (CLOSED) when the gas flow is within the programmed limits. The fault relay can be interfaced to an external weld fixture controller. 3

NOTE: THE FAULT RELAY WILL ONLY BE ACTIVE WHEN POWER IS SUPPLIED VIA THE PLUG-IN TRANSFORMER OR AN EXTERNAL POWER SOURCE CONNECTED TO "AUX" CONNECTOR. 2.5 Gas Flow Volume The GTFM can also be used to monitor accumulated gas flow and to provide an indication when the volume in a gas cylinder has reached a programmed minimum limit. The GTFM will calculate the volume of gas used based on the measure flow rate. If the user programs the initial volume in a cylinder, and the minimum volume for safe operation, the GTFM will indicate when the estimate minimum volume has been reached. The GTFM will flash a "G" on the display when the estimated cylinder volume has decreased below the programmed minimum. Setting the starting volume V to 0 disables the function. NOTE: THE LOW GAS VOLUME FAULT WILL NOT ACTIVATE THE FAULT RELAY BUT WILL INDICATE THE FAULT CONDITION BY FLASHING A "G" ON THE DISPLAY SCREEN. 4

3.0 Operation 3.1 Firmware Version The GTFM is supplied with a plug-in the wall transformer, which powers the GTFM and will also charge the optional internal battery. Plug the transformer into a suitable ac receptacle, and connect the power cable into the "POWER" jack located on the bottom panel of the GTFM. Turn the power switch on the front panel "ON". The LED display will sequentially display the following power up message. 1 ST 2 ND 3 RD GTFM V#.# 0 Where: #.# is the firmware version number Activate the gas solenoid for the welding torch. The GTFM will now display the gas flow rate in CFH (Cubic Feet per Hour). 3.2 Limits To program the High/Low limits and test parameters press the "Mode" switch (left most toggle switch) to the up ("SET") position. The first programmable parameter will appear on the display. The letter displayed on the left most part of the display indicates the selected parameter. To select the next parameter, press the toggle switch to the up ("SET") position. To change any displayed value press the "MODE" switch to the down ("PGM") position. Each pressing of the switch will increment the value by 1. To auto increment the value hold the "MODE" switch in the down ("PGM") position for 1.5 seconds and the GTFM will auto increment the value. Release the switch to terminate the auto increment function. NOTE: PRESSING THE TOGGLE SWITCH DOWN WHILE VIEWING THE ACCUMULATED VOLUME PARAMETER ("U"), WILL RESET THE VALUE TO 0. 3.3 Parameters The following programmable parameters will be displayed with each successive press of the "MODE" toggle switch to the up ("SET") position: L### H### D### Low limit for gas flow testing (cfh/lpm) High limit for gas flow testing (cfh/lpm) Delay time from start of gas flow to enable testing of the high limit (.01 seconds) 5

T### P### M### V### U### Test time that the flow must be continuously out of limits before activating the fault relay (0.01 seconds). The peak gas flow value detected (cfh/lpm) The peak gas flow value detected (cfh/lpm) that when reached, will provide a low gas volume fault indication (Flashing "G" on display). (0-255 cubic ft/liters) The current volume of gas in the cylinder. (0-999 cubic ft/liters) The total volume of gas used based on actual gas flow rates and time. (0-999 cubic ft/liters) Where: ### is the current value for the selected parameter. After displaying the last parameter, the GTFM will return to the normal display mode. If a "MODE" switch function is not activated within 20 seconds, the GTFM will automatically return to the normal display mode. 3.4 Battery Specifications The portable GTFM is supplied with an internal, rechargeable battery. The battery will operate the GTFM continuously for approximately 2 hours when fully charged. The supplied plug-in the wall transformer will recharge the battery in approximately 8-10 hours. The GTFM can be operated while charging the battery. When using the GTFM in battery powered mode the display will automatically clear and a "." will be displayed. This is used to conserve the battery when the GTFM is not measuring actual gas flow. The low power mode will be activated after approximately 25 seconds of no gas flow readings. As soon as gas flow is detected the normal display will return. 6

4.0 SETTING GAS FLOW CONTROL LIMITS 4.1 Description To use the GTFM as a Sure-Flow gas switch, the user can set the upper ("H") and Lower ("L") limits by using the "PGM" toggle switch. The GTFM will activate the internal fault relay as long as the gas flow remains above the lower limit and below the upper limit. If the gas flow rate moves outside of the control limits the fault relay will be deactivated. The "D" parameter is used to delay the start of high limit testing. The value of this parameter will determine when the GTFM will begin testing for the upper control limit after the gas flow is initiated. The lower limit is always being check during the gas flow period. A high gas flow fault will only occur after this time period has expired. The "T" parameter is used to specify the amount of time that the gas flow rate must be continuously above or below the control limits before setting a gas fault condition. 4.2 Setup To set the lower limit select the "L" parameter by pressing the "MODE" switch to the up ("SET") position until the "L" parameter is displayed. While viewing the "L" parameter press the "MODE" switch to the down ("PGM") position to increment to the desired value. To set the Upper limit select the "H" parameter by consecutively pressing the "MODE" switch to the up ("SET") position until the "H" parameter is displayed. While viewing the "H" parameter press the "MODE" switch to the down ("PGM") position to increment to the desired value. NOTE: The lower limit will increment up to the value set by the upper ("H") parameter then it will reset to the 0. The High limit will increment to 255 then reset to the lower ("L") parameter value. 7

5.0 GAS FLOW SURGE "P" MEASUREMENT 5.1 Description The GTFM has a peak value "sample and hold" feature. This allows the user to measure the maximum gas flow rate, which occurred during the welding cycle. The maximum value is the result of a gas surge, which occurs when the gas solenoid is activated. The "MODE" switch on the front panel is used to display the maximum flow rate. The maximum value is displayed by pressing the "MODE" switch to the up position consecutively until the "P" parameter is displayed. The maximum value is reset during power up and when the GTFM first detects gas flow. 8

6.0 GAS FLOW USAGE "U" MEASUREMENT 6.1 Description The GTFM has a gas flow accumulator, which can be used to display total gas usage. This function allows the user to measure the total cubic ft. or liters of gas used from the last time that the accumulator was reset. The maximum volume displayed is 999 cubic ft. If the usage exceeds this value the accumulator will be reset to 0 and will count up from zero as the usage increases. 6.2 Setup NOTE: WHEN GTFM IS EMPLOYED TO MEASURE METRIC VOLUME, THE DISPLAYED USAGE NUMBER MUST BE MULTIPLIED BY TEN (10) TO OBTAIN ACCURATE READING. The accumulated usage value is displayed by consecutively pressing the "MODE" switch to the up ("SET") position consecutively until the "U" parameter is displayed. The value can be reset to zero by pressing the "MODE" key down to the "PGM" position. NOTE: THE GTFM PROVIDES A REASONABLE ESTIMATE OF SHIELDING GAS USAGE. HOWEVER, THIS NUMBER CANNOT BE CONSIDERED TO BE ABSOLUTE SINCE THE GTFM DOES NOT MEASURE OR MONITOR OTHER VARIABLES, WHICH MAY HAVE AN EFFECT ON GAS USAGE, SUCH AS PRESSURE AND TEMPERATURE. 9

7.0 GAS CYLINDER LOW VOLUME MEASUREMENT 7.1 Description The GTFM can be used to provide the user with an indication of when the volume in a cylinder of gas is reaching a low level. To use this function the user must set the starting volume in the cylinder and a minimum value for testing. When the minimum value is reached the GTFM will flash a "G" on the display. The GTFM will display the flashing "G" until the original volume is zero. To disable this function set the "V" parameter to zero. 7.2 Setup To set the starting volume select the "V" parameter by consecutively pressing the "MODE" switch to the up ("SET") position until the "V" parameter is displayed. While viewing the "V" parameter press the "MODE" switch to the down ("PGM") position to increment to the desired value. To set the minimum limit select the "M" parameter by pressing the "MODE" switch consecutively to the up ("SET") position until the "M" parameter is displayed. While viewing the "M" parameter press the "MODE" switch to the down ("PGM") position to increment to the desired value. 10

8.0 GTFM CONNECTOR PIN ASSIGNMENT 8.1 AUX Connector The following is the pin assignment for the "AUX" sensor connector: Pin No. Function 1 + Power input (10-24 vdc @ 100ma) 2 + Analog gas flow rate output 3 - Analog gas flow rate output 4 Common power input 5 Common power input 8.2 RELAY Connector Plug - "LEMO" Manufacture P/N FGG-1B-305-CLAD52Z CWT P/N X3P5628 The following is the pin assignment for the "RELAY" connector: Pin No. Function 1 Relay common 2 N.C. - Will be open when gas flow is within programmed limits. 3 N.O. - Will be closed when gas flow is within programmed limits. Plug - "LEMO" Manufacture P/N FGG-1B-303-CLAD52Z CWT P/N X3P5627 11

9.0 CHANGING THE BATTERY To open the unit, remove the eight (8) screws on the sides of the box. Do not remove the two socket screws in the brass fittings on each side of the box where the inlet/outlet holes are. Carefully lift the cover off. Unplug the battery from JP4. Install the new battery pack and plug the battery onto JP4. Make sure that the Red wire is toward the "RED" marking on the P.C. board and the Black Wire is toward the "BLK" marking on the P.C. board. Reinstall the cover and the eight (8) mounting screws. CWT Replacement Part - P/N X3B5008 4.8V Rechargeable Battery. 12

10.0 MODEL SPECIFICATIONS 10.1 120 VAC Portable GTFM IV System P/N: A0A0032 ITEM QTY PART NO DESCRIPTION 1 1 A3A0179 GTFM4 Enclosure Assembly 2 1 X3B5008 Rechargeable Battery 3 1 A2M0170 Hose/Cone Assembly 4 1 X3T5036 120VAC Power Supply 13

10.2 240 VAC Portable GTFM IV System P/N: A0A0033 ITEM QTY PART NO DESCRIPTION 1 1 A3A0179 GTFM4 Enclosure Assembly 2 1 X3B5008 Rechargeable Battery 3 1 A2M0170 Hose/Cone Assembly 4 1 X3T5047 240VAC Power Supply 14

10.3 ADM IV GTFM IV System P/N: A0A0064 ITEM QTY PART NO DESCRIPTION 1 1 A3A0179 GTFM4 Enclosure Assembly 2 1 A3W0288 GTFM4 Aux. Cable 3 1 A3E0104 GTFM4 Mounting Bar 4 2 #10-32 x 1/2" Lg. Socket Flat Hd. Screw 5 2 X6F5093 Adaptor Fitting 6 2 X6F5094 Barb Fitting 7 2 X6F5095 "B" Size Nut 15

10.4 120 VAC In-Line GTFM IV System P/N: A0A0036 ITEM QTY PART NO DESCRIPTION 1 1 A3A0179 GTFM4 Enclosure Assembly 2 1 X3T5036 120VAC Power Supply 3 1 A3E0104 GTFM4 Mounting Bar 4 2 #10-32 x 1/2" Lg. Socket Flat Hd. Screw 5 2 X6F5093 Adaptor Fitting 6 2 X6F5094 Barb Fitting 7 2 X6F5095 "B" Size Nut 16

10.5 240 VAC In-Line GTFM IV System P/N: A0A0037 ITEM QTY PART NO DESCRIPTION 1 1 A3A0179 GTFM4 Enclosure Assembly 2 1 X3T5047 240VAC Power Supply 3 1 A3E0104 GTFM4 Mounting Bar 4 2 #10-32 x 1/2" Lg. Socket Flat Hd. Screw 5 2 X6F5093 Adaptor Fitting 6 2 X6F5094 Barb Fitting 7 2 X6F5095 "B" Size Nut 17

10.6 GTFM IV Relay Cable P/N: A3W0259 ITEM QTY PART NO DESCRIPTION 1 1 X3P5627 3 Circuit Plug 2 1 X3P5629 Yellow Strain Relief 3 1 X3W5025 3 Conductor Shielded Cable WIRE COLOR FROM DESCRIPTION Black Pin 1 Relay Common Clear Pin 2 Relay N.C. Red Pin 3 Relay N.O. 18

10.7 GTFM IV Aux Cable P/N: A3W0260 ITEM QTY PART NO DESCRIPTION 1 1 X3P5628 5 Circuit Plug 2 1 X3P5629 Yellow Strain Relief 3 1 X3W5037 4 Conductor Shielded Cable WIRE COLOR FROM DESCRIPTION Red Pin 1 Power (10-28 vdc) White Pin 2 VOUT+ (0-2.55 vdc) Green Pin 3 VOUT- Black Pin 4 Common Shield Pin 5 Chassis Ground 19

10.8 GTFM IV Enclosure Assembly P/N: A3W0179 20

ITEM QTY PART NO DESCRIPTION 1 1 A2M0191 GTFM Small Screen 2 1 A2M0192 GTFM Large Screen 3 1 A2M0193 GTFM Display Lens 4 1 A2M0195 GTFM4 Inlet Adaptor 5 1 A2M0196 GTFM4 Outlet Adaptor 6 1 A3A0180 GTFM4 Switch Assembly 7 1 A3E0100 GTFM4 Enclosure 8 1 A3E0101 GTFM4 Cover 9 1 A3E0103 GTFM4 Overlay 10 1 A5A0094 GTFM4 Dual P.C.B. Assembly 11 1 A5I0010 GTFM4 Eprom 12 1 X3Q5002 Flow Cartridge 13 2 X3S5093 Dress Nut 14 1 X4S0100 O-Ring 15 1 X4S5001 O-Ring 16 2 X6S5053 Standoff 17 4 #4-40 X 1/4" Lg. Binder Hd. Screw 18 4 #4 Internal Lock Washer 19 8 #4-40 X 3/16" Lg. Binder Hd. Screw 20 4 #6-32 X 1/2" Lg. Socket Flat Hd. Screw 21

10.9 GTFM IV Mounting Dimensions Rear View Side View Installation with Threaded Inserts Rear View Side View Installation with Mounting Bar 22