LR9 F OVERLOAD RELAYS

Similar documents
3 - Protection components Motor circuit-breakers

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

C -5 to +55 (0.8 to 1.1Uc) Permissible o

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Essential equipment for all your requirements

AF40... AF96 3-pole contactors Technical data

Thermal overload relays Type TA Class 10

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

KD LV Motor Protection Relay

Modular contactors and relays

SIRIUS 3RU2 Thermal Overload Relays

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Protection components

AF series contactors (9 2650)

Application Description

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

References 4 Fuse carriers

Industrial Contactors CTX 3 3P 185A - 800A

AF series contactors (9 2650)

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Short form catalogue. Motor protection & control

AE 9... AE 40 Contactors NE... Contactor Relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Pendant control stations 6

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

1 Phase electronic contactor (SC 1)

RVS-AX Instruction Manual

CI-TI Contactors and motor starters Types CI 61 - CI 98

MAGNETIC MOTOR STARTERS

Technical Information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

4 - Miniature controls

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Manual Motor Starters. Meta-MEC

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Star Series Motor protection & control

CI-TI Contactors and Motor Starters Type CI 6-50

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Bimetal Overload Relays 3UA and 3UC

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Bulletin 825 SMM Smart Motor Manager

Electronic overload relays EF205 and EF370

TAE pole Contactors

Technical Information

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Meta Solution. Contactors and Overload relays

Protection Equipment

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

ASL09..S 3-pole Contactors - Spring Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Protection and control VIP30, VIP35. Relays technical manual

Technical data for manual motor starters Type MS325

Selection Guide Motor Control Device Solutions

CA Z-EN Overload relays, CT-operated overload relays

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

DEVICE STATE/BYPASSED FAILURE OVERLOAD

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

SECTION MOTOR CONTROL

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Industrial Protection Products Edition

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

and other modular devices for low voltage installation

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

DX³ RCCBs - ID 4P up to 100 A

MCD 200 Series Soft Starters

Industrial contactors CTX-1

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Meta Solution. Contactors and Overload relays

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Description. Positive safety relays

Transcription:

Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue

General 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common, and which is often accidental, is the utilisation of motors beyond the operating limits defined by the manufacturer or in abnormal ambient conditions. A statistical survey carried out in Britain, covering 9000 incidents of motor failure, gave the following results: Overloads 0 % Pollution (example: corrosive atmosphere) 9 % Phase failure 4 % Bearing failure % Ageing (example: ambient temperature too high) 0 % Rotor faults 5 % Miscellaneous 9 % These faults are related to motors with a power rating of 7 kw or more. An examination of the above results shows that, in more than 50 % of cases, the fault is due to the effects of heating. Leaving aside the replacement of wearing parts, such as bearings, slip rings, brushes, etc., the life of a rotating machine is linked to that of its insulation. Provided that the temperature rise limit is not exceeded, the life expectancy of insulating materials is extremely long. It is decreased by approximately one half for an excess temperature rise of 0 C. The operating temperature limit TL of an insulating material depends on the type of material and is the sum of the ambient air temperature AT (cooling air), the temperature rise limit TRL and an additional temperature rise value ATR considered necessary because the measurement of winding resistance variation does not determine the temperature of the hottest part of the motor winding, but only gives an average value for temperature rise. The diagram below defines the standardised limits for different classes of insulation. In all cases, the normal ambient cooling air temperature is fixed at 40 C. 80 65 55 40 0 25 20 5 00 80 ATR TRL TL 60 40 20 AT 0 E B F H Insulation classes Based on Schneider MKTED2050EN Catalogue Page of 4

General (continued) 6 Motor protection The rated power of a motor corresponds to its temperature rise limit for an ambient temperature of 40 C. The standard temperature rise limits for the different parts of a machine are given in the following table, which is an extract from publication IEC 6004-. Temperature rise limit in C Insulation class B F H Insulated winding 80 00 25 (measurement by resistance) Commutators and slip-rings 80 90 () 00 () Bearings 60 60 (2) 60 (2) When a motor is used at an ambient air temperature other than the normal value, its temperature rise limit should be modified in order to maintain the same maximum temperature limit. The result is that the motor operational power is no longer the same as its rated power. Also, the altitude of the installation, if this is above 000 m, affects the cooling and increases the temperature rise. The following table gives the ratio between operational power and rated power, according to the operating conditions, for a given ambient temperature. It corresponds to insulation class B. Operational power / Rated power in watts Altitude Ambient temperature m 0 C 5 C 40 C 45 C 50 C 55 C 60 C 000.07.04.00 0.96 0.92 0.87 0.82 500.04.0 0.97 0.9 0.89 0.84 0.79 2000.0 0.98 0.94 0.90 0.86 0.82 0.77 2500 0.97 0.95 0.9 0.87 0.84 0.79 0.75 000 0.9 0.9 0.87 0.84 0.80 0.76 0.7 500 0.89 0.86 0.8 0.80 0.76 0.72 0.68 4000 0.8 0.8 0.78 0.75 0.72 0.68 0.64 The values shown in the above table are for guidance only. In effect, the derating of a motor depends on its size, insulation class, method of construction (self-ventilated or forced ventilation, degree of protection IP 2, IP 44, etc.), and varies according to the manufacturer. Also, in addition to the normal ambient conditions, the rated power of a motor is defined by the manufacturer for continuous duty S. This covers continuous operation of sufficient duration to enable the motor to reach a steady temperature. It is this value of rated power that is normally shown on the motor plate. There are other standardised types of duty, such as temporary duty S2, or intermittent periodic duty type S, S4 and S5, for which the motor manufacturer defines an operational power appropriate to each and different from the rated power. () For temperature rise limits of 90 C and 00 C the brushes must be selected with the agreement of the motor manufacturer. (2) These limit values may be exceeded, depending on the quality of the grease used and the applied loads. Based on Schneider MKTED2050EN Catalogue Page 2 of 4

General 6 Motor protection Selection of thermal protection To optimise the life of a motor, it is important to select the appropriate thermal protection which will prevent operation under abnormal heating conditions, whilst ensuring maximum continuity in the operation of the driven machine or associated plant by avoiding unnecessary stoppages. It is essential to know the real operating conditions: b ambient temperature, b operating altitude, b type of standard duty, in order to determine the operational values for the motor (power, current) and to be able to select efficient thermal protection. These operational values are given by the motor manufacturer. Various types of thermal protection devices are available: b thermal overload relays or thermal-magnetic motor circuit-breakers, b thermistor protection relays, with PTC thermistor probes () b multifunction relays. by thermal overload relay A conventional thermal overload relay protects the motor in the following two cases: b overload, by monitoring the current drawn by each phase, b phase imbalance or failure, by its differential mechanism. It therefore covers 44% of the cases of motor failure. This type of protection relay is widely used, is extremely reliable and is a relatively low cost device. It is particularly recommended if there is a risk of rotor locking. Nevertheless, it has the disadvantage of not taking into account, with sufficient accuracy, the thermal state of the motor. The operating principle of this type of device is, in fact, based on the bending of bimetal strips caused by the current drawn by the motor. As the thermal inertias of the overload relay and motor are different, in some cases it may be possible to restart the motor following an overload trip even though its temperature is still too high. by instantaneous electronic over current relays LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements. By monitoring the current through the current transformers with which they are equipped, they provide protection against: b overtorque or mechanical shock, b locked rotor (mechanical locking under steady state conditions), b phase failure. These relays are particularly recommended for providing mechanical protection on machines with: b high resistive torque, b high inertia, b and with strong probability of locking under steady state conditions. They do not incorporate a thermal overload memory and can therefore be used to provide motor protection in severe duty applications, such as: b long starting times, b frequent starting. These relays have definite time characteristics: current threshold and time based function Because of their two separate time settings "D-Time" (starting time) and "O-Time" (trip time during steady state), these over current relays can be combined with the motor-starter function. () PTC: Positive Temperature Coefficient Based on Schneider MKTED2050EN Catalogue Page of 4

General (continued) 6 Motor protection Resistance (Ω) 4000 0 550 250 00 50-20 0 Temperature ( C) Markings complied with by universal probes Mark A (standard EC 6004--A) NOT -20 NOT -5 NOT NOT +5 NOT +5 by PTC thermistor relay Better monitoring of the internal motor temperature can be provided by PTC thermistor probes, embedded in the motor windings during manufacture, associated with a thermistor protection relay (type LT S). PTC probes are resistors with a positive temperature coefficient. Their resistance value increases very rapidly when their temperature reaches the Nominal Operating Temperature threshold, indicated by NOT on the curve opposite. Their small size means that they have a low thermal inertia and can rapidly follow the temperature variations of their surroundings. This is the only solution for motor protection in applications involving severe starting/ stopping (duties S, S4, S5) and, likewise, for applications where the motor could be inadvertently overcooled. Problems other than those due to thermal effect can also arise: earth fault, abnormal overheating of bearings, etc. More comprehensive protection can be obtained: b either by associating several types of protection device (example: thermal overload relay + thermistor protection relay + earth fault relay), b or by using a multifunction protection relay type LT6. relays Relay type Thermal Over overload () current LR2 K, LRD, LR97D LR9 F Causes of overheating Over current LT47 For use with PTC probes LT Multifunction LT6 Slight overload Locked rotor Underload Supply phase failure Ventilation fault With PTC probes Abnormal rise in ambient temperature Shaft bearing seizure Insulation fault With PTC probes With PTC probes Protracted starting time Severe duty With PTC probes Ideally suited Possible solution Not suitable (no protection) () Or motor circuit-breaker type GV2 ME, for example. Based on Schneider MKTED2050EN Catalogue Page 4 of 4

Presentation 6 Presentation LR9 F electronic protection relays are especially suited to the operating conditions of motors. They provide protection against: b thermal overload of -phase or single-phase balanced or unbalanced circuits; b phase failure and large phase unbalance, b protracted starting times, b prolonged stalled rotor condition. LR9 F electronic protection relays are mounted directly below an LC F type contactor. They cover a range from 0 to 60 A, in eight ratings. The settings can be locked by sealing the transparent protective cover. A reset button is mounted on the front of the relay. Two versions are available: b simplified version: class 0: LR9 Fppp, class 20: LR9 Fp5pp, b complete version: class 0, 0 A or class 20, selectable, conforming to EN 60947-4-: LR9 Fpp. This latter version includes an alarm function which makes it possible to forestall tripping by load shedding. Simplified version: class 0 or 20 2 07 90 50 Ir(A) 27 5 4 NO 98 97 NC 95 96 6 Complete version: class 0, 0 A or class 20, selectable, and alarm circuit 7 8 2 07 90 Class Load Ir(A) 20 27 0 + 24 V - / 0 04 50 Alarm NO 98 97 NC 95 96 5 4 9 6 Ir adjustment dial 2 Test button Stop button 4 Reset button 5 Trip indicator 6 Setting locked by sealing the cover 7 Class 0/class 20 selector switch 8 Selector switch for balanced load /unbalanced load 9 Alarm circuit Based on Schneider MKTED2050EN Catalogue Page 5 of 4

Characteristics 6 Environment Conforming to standards IEC 60947-4-, IEC 60255-8, IEC 60255-7, EN 60947-4- and VDE 0660 Product certifications UL 508, CSA 22-2 Degree of protection Conforming to VDE 006 IP 20 Conforming to IEC 60529 IP 20 on front of relay with accessories LA9 F0 or LA7 F70p, see page 2 Protective treatment Standard version TH Ambient air temperature around the device (conforming to IEC 60255-8) Storage C - 40 + 85 Normal operation C - 20 + 55 () Maximum operating altitude Without derating m 2000 Operating positions without derating Shock resistance Vibration resistance In relation to normal vertical mounting plane Permissible acceleration conforming to IEC 60068-2-7 Permissible acceleration conforming to IEC 60068-2-6 Any position gn - ms 2 gn - 5 to 00 Hz Dielectric strength at 50 Hz Conforming to IEC 255-5 kv 6 Surge withstand Conforming to IEC 6000-4-5 kv 4 Resistance to electrostatic discharge Resistance to radiated radio-frequency disturbance Resistance to fast transient currents Electromagnetic compatibility Conforming to IEC 6000-4-2 kv 8 (in air) 6 (in indirect mode) Conforming to IEC 6000-4- V/m 0 Conforming to IEC 6000-4-4 kv 2 EN 5008- and 2, EN 50082-2 Conforming () For operating temperatures up to 70 C, please consult your Regional Sales Office. Based on Schneider MKTED2050EN Catalogue Page 6 of 4

Characteristics (continued) 6 Electrical characteristics of power circuit Relay type LR9 F5p57, F57 F5p6, F6 F5p67, F67 F5p69, F69 Rated insulation voltage Conforming to IEC 60947-4 V 000 (Ui) Rated operational voltage Conforming to VDE 00 gr C V 000 (Ue) Rated impulse Conforming to IEC 60947- kv 8 withstand voltage (Uimp) Rated operational current (Ie) A 0 to 60 F5p7, F7 F7p75, F75 F7p79, F79 F7p8, F8 Short-circuit protection and coordination See pages: 24540/2, 24540/, 24544/2 and 24544/ Frequency limits Of the operating current Hz 50 60. For other frequencies, please consult your Regional Sales Office () Power circuit connections Width of terminal lug mm 20 25 25 0 LR9 F7p75 40 and LR9 F75 40 LR9 F7p79 and LR9 F79 Clamping screw M6 M8 M0 M0 M2 Tightening torque N.m 0 8 5 5 58 Auxiliary contact electrical characteristics Conventional thermal current A 5 Short-circuit protection Control circuit connections By gg or BS fuses or by circuit-breaker GB2 CD0 Flexible cable with cable end A 5 Min. Max. conductor mm 2 x 0.75 x 2.5 2 conductors mm 2 2 x 2 x.5 Flexible cable without cable end conductor mm 2 x 0.75 x 4 2 conductors mm 2 2 x 2 x 2.5 Solid cable conductor mm 2 x 0.75 x 2.5 2 conductors mm 2 2 x Tightening torque N.m.2 Maximum sealed current consumption of the coils of associated contactors (occasional operating cycles of contact 95-96) a.c. supply V 24 48 0 220 80 600 VA 00 200 400 600 600 600 d.c. supply V 24 48 0 220 440 W 00 00 50 45 25 () For applications involving the use of these overload relays with soft starters or variable speed drives, please consult your Regional Sales Office. Based on Schneider MKTED2050EN Catalogue Page 7 of 4

Characteristics (continued) 6 Operating characteristics Tripping class Conforming to IEC 60947-4- 0, 0 A and 20 Temperature compensation C - 20 + 70 Reset Fault indication Test function Stop function Tripping thresholds Sensitivity to phase failure Adjustment (nominal motor current) Security sealing Conforming to IEC 60947-4- Conforming to IEC 60947-4- Manual on front of relay On front of relay On front of relay Alarm A.05 ± 0.06 In Tripping A.2 ± 0.06 In Actuation of N/C contact, without affecting N/O contact Tripping in 4 s ± 20 % in the event of phase failure Setting dial on front of relay Yes Alarm circuit characteristics Rated supply voltage d.c. supply V 24 Supply voltage limits V 7 2 Current consumption No-load ma y 5 Switching current ma 0 50 Short-circuit and overload Auto-protected Voltage drop Closed state V y 2.5 Connection Flexible cable without cable end mm 2 0.5.5 Tightening torque N.m 0.45 LR9 F tripping curve Average operating times depending on multiples of the setting current Class 0 Class 20 Tripping time in seconds 000 Tripping time in seconds 000 00 00 0 2 0 2 0 2 4 5 6 7 8 9 0 2,2 x times the setting current (Ir) 0,2 2 4 5 6 7 8 9 x times the setting current (Ir) Cold state curve 2 Hot state curve Based on Schneider MKTED2050EN Catalogue Page 8 of 4

References 6 for motor protection Compensated and differential overload relays Thermal overload relays: b compensated and differential, b with relay trip indicator, b for a.c., b for direct mounting on contactor or independent mounting (). 89555 Relay setting range Fuses to be used with selected relay am gg For direct mounting beneath contactor LC Reference Weight A A A Class 0 (2) 0 50 50 80 F5 F85 LR9 F557 0.885 48 80 80 25 F5 F85 LR9 F56 0.900 60 00 00 200 F5 F85 LR9 F567 0.900 LR9 F5pp 90 50 60 250 F5 F85 LR9 F569 0.885 2 220 250 5 F85 F400 LR9 F57 0.950 200 0 400 500 F225 F500 LR9 F775 2.20 89556 00 500 500 800 F225 F500 LR9 F779 2.20 80 60 60 800 F400 F60 and LR9 F78 4.60 F800 Class 20 (2) 0 50 50 80 F5 F85 LR9 F5557 0.885 48 80 80 25 F5 F85 LR9 F556 0.900 LR9 F7pp 60 00 00 200 F5 F85 LR9 F5567 0.900 90 50 60 250 F5 F85 LR9 F5569 0.885 2 220 250 5 F85 F400 LR9 F557 0.950 200 0 400 500 F225 F500 LR9 F7575 2.20 00 500 500 800 F225 F500 LR9 F7579 2.20 80 60 60 800 F400 F60 and LR9 F758 4.60 F800 () When mounting overload relays up to size LR9 F57 directly beneath the contactor, they may be additionally supported by a mounting plate (see page 2). Above this size it is always necessary to use the mounting plate. Power terminals can be protected against direct finger contact by the addition of shrouds and/ or insulated terminal blocks, to be ordered separately (see page 2). (2) Standard IEC 60947-4 specifies a tripping time for 7.2 times the setting current In: - class 0: between 4 and 0 seconds, - class 20: between 6 and 20 seconds. Based on Schneider MKTED2050EN Catalogue Page 9 of 4

References (continued) 6 for motor protection Compensated overload relays, class 0 or 20 with alarm Thermal overload relays: b compensated, b with relay trip indicator, b for a.c., b for direct mounting on contactor or independent mounting (), b class 0 or 20 by selector switch, b protection of -phase or single-phase circuits by selector switch, b with alarm function that enables tripping to be forestalled. 89557 Relay setting range Fuses to be used with selected relay am gg For direct mounting beneath contactor LC Reference Weight A A A 0 50 50 80 F5 F85 LR9 F57 0.885 48 80 80 25 F5 F85 LR9 F6 0.900 60 00 00 200 F5 F85 LR9 F67 0.900 90 50 60 250 F5 F85 LR9 F69 0.885 LR9 F57 2 220 250 5 F85 F400 LR9 F7 0.950 200 0 400 500 F225 F500 LR9 F75 2.20 00 500 500 800 F225 F500 LR9 F79 2.20 80 60 60 800 F400 F60 and LR9 F8 4.60 F800 () When mounting overload relays up to size LR9 F7 directly beneath the contactor, they may be additionally supported by a mounting plate (see page 2). Above this size it is always necessary to use the mounting plate. Power terminals can be protected against direct finger contact by the addition of shrouds and/ or insulated terminal blocks, to be ordered separately (see page 2). Based on Schneider MKTED2050EN Catalogue Page 0 of 4

References 6 Accessories (to be ordered separately) LA7 D0p Control accessories Description Sold in lots of Unit reference Weight Remote electrical reset device () LA7 D0p (2) 0.090 Remote Reset function control by flexible cable (length = 0.5 m) LA7 D05 0.075 Remote Stop and/or Reset function control Adapter for door mounted operator LA7 D020 0.005 LA7 D05 R Rod (snap-off end to obtain required length, between 7 and 20 mm) Operating head for spring return pushbutton 0 ZA2 BZ 0.00 ZA2 Bpppp () 0.02 Connection accessories For mounting an LR9 F5p7 thermal overload relay together with an LC F85 contactor Description Reference Weight Set of busbars LA7 F407 0.60 For mounting a thermal overload relay beneath a reversing contactor or star-delta contactors Application Width of Set of busbars Weight For relay For contactor terminal lug Reference mm LR9 F5p57, F5p6, F5p67, LC F5 5 LA7 F40 0.0 F5p69, F69, F7 LR9 F5p57, F5p6 LC F50, F85 20 LA7 F402 0.0 LR9 F5p7, LR9 F7 LR9 F5p7, LR9 F7 LR9 F7p75, F7p79, LR9 F75, F79 LR9 F7p8, LR9 F8 LC F85 25 LA7 F407 0.60 LC F225, F265 25 LA7 F40 0.60 LC F225...F400 25 LA7 F404 0.60 LC F400 25 LA7 F404 0.60 LR9 F7p75, F7p79, F7p8, LR9 F75, F79, F8 LC F500 0 LA7 F405 0.270 LR9 F7p8, LR9 F8 LC F60, F800 40 LA7 F406 0.600 () The time for which the coil of remote electrical reset device LA7 D0 can remain energised depends on its rest time: s pulse duration with 9 s rest time; 5 s pulse duration with 0 s rest time; 0 s pulse duration with 90 s rest time. Maximum pulse duration of 20 s with rest time of 00 s. Minimum pulse time: 200 ms. (2) Reference to be completed by adding the coil voltage code. Standard control circuit voltages, (for other voltages, please consult your Regional Sales Office) : Volts 2 24 48 96 0 220/ 20 80/ 400 a 50/60 Hz B E F M Q N Consumption, inrush and sealed: < 00 VA c J B E DD F M Consumption, inrush and sealed: < 00 W. () Stop: ZA2 BL42 and Reset: ZA2 BL69. 45/ 440 Based on Schneider MKTED2050EN Catalogue Page of 4

References (continued) 6 Accessories (to be ordered separately) Mounting plates for overload relay For use with relays Reference Weight LR9 F5p57, F5p6, F5p67, F5p69, F5p7, LR9 F57, F6, F67, F69, F7 LA7 F90 0.00 LR9 F7p75, F7p79, F7p8, LR9 F75, F79, F8 LA7 F902 0.00 LA7 F90p Sets of power terminal protection shrouds, single-pole For use with relays LR9 F5p57, LR9 F57 Number of shrouds per set Set reference Weight 6 LA9 F70 0.05 LR9 F5p6, F5p67, F5p69, LR9 F6, F67, F69 LR9 F5p7, LR9 F7 LR9 F7p75, F7p79, F7p8, LR9 F75, F79, F8 6 LA9 F702 0.05 6 LA9 F705 0.05 6 LA9 F70 0.05 LA9 F70p Power terminal protection shrouds, -pole For use with relays LR9 F5p57, F5p6, F5p67, F5p69, LR9 F57, F6, F67, F69 Reference Weight LA7 F70 0.00 LA7 F70p LR9 F5p7, LR9 F7 LR9 F7p75, F7p79, F7p8, LR9 F75, F79, F8 Insulated terminal blocks For use with relays LR9 F5p57, F5p6, F5p67, F5p69, LR9 F57, F6, F67, F69 LA7 F702 0.00 LA7 F70 0.00 Set of 2 blocks Reference Weight LA9 F0 0.560 Marking accessories Description Sold in lots of Unit reference Weight Clip-in marker holder 00 LA7 D90 0.00 LA9 F0 Bag of 400 blank self-adhesive legends 7 x 6 mm LA9 D9 0.00 Based on Schneider MKTED2050EN Catalogue Page 2 of 4

Dimensions 6 Common side view LR9 F5p7, F7 LR9 F5p57, F5p6, F5p67, LR9 F5p69, F57, F6, F67, F69 () 2,5 56,8 48 25 48 20 50 50 (2) 50 40 50 40 44,8 0 76 60 7 96 60 7 76 5,5 5,5 46,8 5 20 5 () Terminal shroud LA9 F70p (2) 6.5 x.5 for LR9 F5p57 and F57. 8.5 x.5 for LR9 F5p6, F5p67, F5p69, F6, F67, F69 Common side view LR9 F7p75, F7p79, F7p8, LR9 F75, F79, F8 LR9 F7p8 (for mounting beneath LC F60 and F800), LR9 F8 27,6 () 42,2 44,8 08,8 4 70 22, P 0 P2 25 6 82 6,8 228,8 88,8 20 62, 80 200 80 40 6 5,5 5,5 66 66 () Terminal shroud 50 LA9 F70p P P2 LR9 F7p75, F75 48 48 LR9 F7p79, F7p8, F79, F8 55 55 Direct mounting beneath contactor LC F 76,5 76,5 9 Mounting beneath contactors: reversing LC2 F or star-delta LC F 40 Mounting plate for LR9 F H H2 b H H H2 G LA7 F4 () (2) () H H2 b LA7 G F90 45 F902 90 () (2) () Contactors LC With LR9 relays b H H2 H Contactors LC With LR9 relays b H H2 H F5 F5p57, F5p6, F5p67, F5p69, 240 0 50 20 F5 F5p57, F5p6, F5p67, F5p69, 279 60 50 20 F57, F6, F67, F69 F57, F6, F67, F69 F50 F85 F5p57, F5p6, F5p67, F5p69 F57, F6, F67, F69 F5p57, F5p6, F5p67, F5p69 F57, F6, F67, F69 246 0 50 20 F50 F5p57, F5p6, F5p67, F5p69 F57, F6, F67, F69 250 0 50 20 F85 F5p57, F5p6, F5p67, F5p69 F57, F6, F67, F69 28 60 50 20 285 60 50 20 F225 F5p7, F7 27 40 50 20 F225 F5p7, F7 F7p75, F7p79, F75, F79 08 50 58 20 F7p75, F7p79, F75, F79 60 00 58 20 F265 F5p7, F7 279 40 50 20 F265 F5p7, F7 2 90 50 20 F7p75, F7p79, F75, F79 4 60 58 20 F7p75, F7p79, F75, F79 6 00 58 20 F0 F7p75, F7p79, F75, F79 7 60 58 20 F0 F7p75, F7p79, F75, F79 64 00 58 20 F400 F7p75, F7p79, F7p8, F75, F79, F8 7 60 58 80 F400 F7p75, F7p79, F7p8, F75, F79, F8 64 00 58 80 F500 F7p75, F7p79, F7p8, F75, F79, F8 46 70 58 80 F500 F7p75, F7p79, F7p8, F75, F79, F8 90 0 58 80 F60, F800 F7p8, F8 50 0 58 80 F60, F800 F7p8, F8 509 20 58 80 () Relay mounting plate LA7 F90p, see page 2 () DZ5 MB for LC F5 to F400 (2) AM EC or AM DF for LC F5 to F60 and LC F800 Based on Schneider MKTED2050EN Catalogue Page of 4

Schemes, setting-up 6 Schemes LR9 F5p57 F7p8 LR9 F57 F8 (with alarm) KM /L /L2 5/L Test Test Stop Stop Man. reset 95 Man. reset 95 2/T 4/T2 6/T 96 98 97 A M KM 4 2 4 6 L 5 L2 L KM () /L /L2 5/L 0 04 (4) () 2 % 2/T 4/T2 6/T 96 98 97 A M M KM 4 2 4 6 + 0 V L L2 L 5 (2) () + (4) (2) () M N KM A A2 () N KM A A2 () () Tripped on thermal overload (2) Overheating alarm () Setting current (4) Specialised circuit Setting-up the special functions of LR9 F thermal overload relays Setting the relay b Lift the transparent cover 7 to gain access to the various settings. b Adjustment is achieved by turning dial which is graduated directly in Amperes. b The setting can be locked by sealing the cover 7. 7 05 90 LR9 F569 Ir(A) 25 50 protection électronique moteur ELECTRONIC MOTOR PROTECTION TEST TRIPPED STOP RESET NO 98 97 NC 95 96 6 5 4 2 Stop function Test function 2 Stop Test Trip indicator PED STOP RESET TRIPPED TEST STOP RESET TRIPPED TEST STOP RE b The Stop function is obtained by pressing the red STOP button. b Pressing the Test button: v actuates the N/C contact, v has no effect on the N/O contact. b The STOP button can be locked by fitting a U clip (reference: LA7 D90). b The Test function is obtained by pressing the red TEST button 2 with a screwdriver. b Operation of the TEST button simulates tripping of the relay and: v actuates both the N/O and N/C contacts, v actuates the trip indicator 5. Based on Schneider MKTED2050EN Catalogue Page 4 of 4