Single or Double 240VAC motor control for domestic and industrial gates and doors.

Similar documents
ELSEMA 240VAC Slider Control Board, SLD

ELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue

Gate & Door Controller with LCD and Intelligent Technology

TEL: G&C Electronics CC E. T.

The House of Gate Automation

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

Typical applications are the control of barriers/booms in the parking and access control environments.

PART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026

Installation and Maintenancee Manual

GLM SERIES CONTROL Users Manual Rev:

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

CB-9 CONTROL BOARD INSTRUCTION MANUAL

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SKC400U SLIDING GATE OPENER OWNER S MANUAL

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Security alarms, warning systems.

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

3 Slot Payphone Controller

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

DEEP SEA ELECTRONICS PLC

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

OVERLOAD PROTECTION. All electrical circuits must have some means of protecting against overload.

MX431 Generator Automatic Voltage Regulator Operation Manual

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

Sectional And Tilting Door Opener

Auto Gate System. General Description. Features EL-888A. elock EL-888A is an electro-mechanical complete system for. EL-888A (Auto gate)

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

BARRY BARRIER GATE AUTOMATION

USER MANUAL. Automated Vehicular Boom Gate. Version: 1.0 Date: March, 2015

HIGH SPEED SLIDING GATE OPENER

Sliding Gate Operator User's Manual

LI-2B Installation Manual

Pro Series 600 Pro Series 800

DEEP SEA ELECTRONICS PLC

General Information...3. Features...5. Parts Identification...6. Installation...8. Alternate Installation Electrical Fine Tuning...

Application Engineering

Installing the gate post bracket with the cardboard arm template

Application Engineering

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

SLIDING GATE OPENER USER MANUAL

General Information...3. Features...5. Parts Identification...6. Installation...8. Alternate Installation Electrical Fine Tuning...

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

YG101 SWING GATE OPENER OWNER S MANUAL

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

DEEP SEA ELECTRONICS PLC

PY600AC Sliding Gate Opener User Manual

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

ELECTRICAL. CDTA Technical Training Center

Euclid Full Voltage Magnet Controller

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

Bringing Component Parts Together

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

Insert Residential Opener Tab Here

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

Components for EEx e Panels

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

TECHNICAL DATA HYDRAULIC UNIT

MaxPak Plus Analog DC V S Drive

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

SWING GATE OPENER SW300 SERIES

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

EMERGENCY VEHICLE BATTERY MANAGER PS2024

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Installing the gate post bracket with the cardboard arm template

ADJUSTABLE FREQUENCY CRANE CONTROLS

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

PS24/AC Volt AC 16 Amp

LD Operating Manual S A ELECTRONIC USTRALIA. LD Volt Owners Manual. Warnings and electrician s notes Hints and Pointers Examples

Instruction Manual for the. E-SL 450 Series

INSTALLATION M ANUAL

MODEL 422 Submersible Pump Controller

AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

Small Full Bridge Permanent Magnet Motor DC Controller User Manual

Sliding Gate Operator User's Manual

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

MCC Automatic Start-Stop Microcomputer Charger Control

JANDS DD-8. Technical Manual. Version 1.0

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

MS-1 SPEED COMMANDER DOOR CONTROL INSTALLATION MANUAL. issue 1

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

HWP Protection Board

PRODUCT INFORMATION BULLETIN

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

RAMSET RAM

REVISION HISTORY REVISION HISTORY

RP-4000 Reserve Power Control

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Transcription:

COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option for receiver plug-in ELSEMA Application Single or Double 240VAC motor control for domestic and industrial gates and doors. Description The COBO30 is an upgrade of the older COBO20. The COBO30 has built-in transformer, auto close, open only, security close and extended lock pulse. The COBO30 card is used to control automatic door/gate that have 240VAC motor with limit switches. It can be used for either single or double gates. Even hydraulic doors can be wired to the COBO30 card. Hydraulic doors have overflow fluid limits which requires the COBO30 to disable the electronic limit switches. This is selectable by linking the limit switches. Limit switches are linked as factory defaults. The COBO30 has a built-in lock control, push button, photocell control, wireless operation with a remote control transmitter, door open indicator (LED Output), limit switch connection and 24VAC Output. The COBO30 is also available in a weatherproof plastic case C220 and is called COBO30E Options, Auto Closing, Open Only, Security Closing and Extended Lock Pulse are user selectable using the on board 4-way dip switch. See table below: Switch on 4-way dip switch ON OFF Enables Auto Close Disables Auto Close Enables Auto Close and Open Only Enables Auto Close, Security Close and Open Only Extended Lock Pulse 4sec Enables Auto Close, Special Security Close and Open Only Disables Auto Close and Open Only Disables Auto Close, Security Close and Open Only Normal Lock Pulse 2sec Disables Auto Close, Special Security Close and Open Only

Auto Closing Enabled when switch 1 is on. The AC timer can be adjusted from 3 to approximately 30 seconds by the on board trimpot called AC. Auto Close timer starts when the door has opened and stopped. Input from the Photo Cell terminal will hold-off the closing cycle. Open Only Enabled when switch 2 is on. This feature enables the user to open the door/gate but when the door/gate is opening the remote control is disabled and the door will fully open. Door closes when auto close timer expires. Security Closing Enabled when switch 3 is on. The door/gate immediately closes after the photo beam is broken and the vehicle moves away from the photo beam, even if the door/gate is not fully open. If the door/gate is opening and no vehicle passes through the door/gate then Auto Close will close the door/gate. An Auto Close time of 3 to 30 seconds can be set on the COBO30 board using the trimpot marked AC. Extended Lock Pulse Enabled when switch 4 is on. Lock pulse provides a 2 second pulse on opening and closing cycle on a standard 12-volt lock. When extended lock pulse is enabled an additional 2 seconds is provided, bringing the total lock pulse to 4 seconds. This will result in a 4 second closing and opening delay, between motor 1 and 2. To use the 2 or 4-second pulse feature, a suitable transformer needs to be connected to the COBO30. This transformer will supply the extra current that will operate the lock. Recommend transformer size is 60VA to 100VA. Also a link has to be placed beside the 1N4004 diode. Refer to the picture below for the location of the link. Updated March 2008. If your existing card does not have white cement 8.2 ohm, 5 Watt resistor, please contact Elsema and we will provide you with this resistor for free.

Special Security Close Enabled when switch 1 and 2 are on. Same as Security Close except door does not reverse to open when Photo beam is broken. This is to prevent car-tailing on more secure sites. Other Features Pedestrian Access In opening direction the door/gate can be stopped when it is opening. This allows the user to open the door/gate partially to give pedestrian access. Red Led Red OP and CL LED indicate that the motor is running, when the led is on. If motor is not running and either one of the LED s is on check motor wire connections. (Note: This feature will only work if the Limit Switches are used) Travel Timer (TRV pot) The travel timer is factory preset to maximum (30 seconds) and should not be adjusted when motors with limit switches are used. When Hydraulic operation, i.e. no limit switches is used, then you will need to adjust the travel timer. Set the travel-timer to stop relays as indicated by red OP and CL led. We recommend approximately 3 seconds after the door/gate is fully opened or closed. The OP or CL led should go off after 3 seconds when door/gate is fully opened or closed. If an extra 30 seconds travel time is required, switch the one-way switch (S1) next to the TRV trimpot to on. Replaceable Fuse Replaceable 240VAC 5Amp fuse.

Technical & Installation Instruction Care should be taken not to cross printed circuit board with 240V wires over or under the board. This would induce spikes onto the sensitive circuitry of the printed circuit board. When COBO30 PCB is used to switch contactors (see warning note below), a VDR (Voltage Dependent Resistor 275V AC) must be connected across the coil of contactor. Warning Note When connecting contactors directly to the card you must removed the motor capacitors from the cards capacitor terminal blocks. Motor capacitor should be connected directly to the motors. The motors should also have a thermal overload.

Wiring Connections ELSEMA Power Connect 240 VAC to the terminal block marked 240 VAC. Motors Motors should be rated for 240 VAC. Each motor should have three wires, i.e. two actives and one neutral. One active is for opening and the other is for closing. Both motors operate in parallel. However, motor two has a two second delay on closing to allow double gates to overlap. Motor starting capacitors of 10µF are provided depending on manufacture of motor specifications. Lock Output This terminal block outputs a short pulse on opening and closing cycle. This is used for a standard 12V lock. To extend lock pulse, set code switch 4 to the on position. To use the 2 or 4-second pulse feature, a suitable transformer needs to be connected to the COBO30. This transformer will supply the extra current that will operate the lock. Recommend transformer size is 60VA to 100VA. Push Button Input Push button is a normally open contact. When pressed it will start the opening or closing cycle. This push button should be waterproof for internal and external use. Waterproofing will prevent false activations, which normally occurs due to moisture inside the button. Door or gate can be held open permanently when push button is pressed continuously. Photo Cell Input Photo Cell input is normally closed contact. The photocell is used as a safety feature. If the doors/gates are closing and the photo beam is broken, the door/gate will stop instantly and then open fully. Should an object be blocking the door/gate (i.e. photo cell is broken), closing cycle or auto closing is disabled. A red LED on the controller card labeled as PC indicates photo beam is broken. A handy feature when photocell is not near the box. Antenna The antenna connection is used to connect an antenna for the plug in FMR-201, GLR2701SS or GLR43301SS. The antenna can be a 50 ohms 27 MHz CB-Antenna or piece of approximately 1 metre of wire. X Output Terminal block marked X has 24 Volt DC outputted whilst the door is moving. This allows you to connect a 24V relay on terminal marked X to switch a warning light or horn when the door is moving. X output can source 20mA. Led Output If a visual indication of the gate or door status is required at a remote place, a LED can be wired to terminal block marked LED. This LED will be on (and stay on) when gate is open and off when gate is closed. (Note: This feature will only work if the Limit Switches are used)

Limit Switches The limit switches are normally closed. To use limit switches remove links from the terminal blocks and wire to relevant limit switches. For three wire operation of limit switches, use two outside holes of terminal block and one positive of the limit switch terminal block (see diagram). Low voltage wiring (24V) can be used for the limit switches. 24 Volts Out This terminal is used to supply an external device that uses 24 VAC (up to 120mA can be sourced). For example, if you want to connect a Loop Detector (LD30) you could use this terminal block to supply power to the Loop Detector. Remote Control Remote control is achieved by inserting Elsema s Plug-in type receivers. Power to the COBO30 printed circuit board should be switched off during the installation of a receiver. The transmitter should be compatible with the type of receiver used. Manufactured by Distributed by Elsema Pty Ltd 3/10 Hume Rd, Smithfield NSW 2164, Australia Ph: 02 9609 4668 Fax: 02 9725 2663 Website: http://www.elsema.com