ELSEMA 240VAC Slider Control Board, SLD

Similar documents
Single or Double 240VAC motor control for domestic and industrial gates and doors.

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

ELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue

Gate & Door Controller with LCD and Intelligent Technology

CB-9 CONTROL BOARD INSTRUCTION MANUAL

PART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

TEL: G&C Electronics CC E. T.

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

TECHNICAL DATA HYDRAULIC UNIT

SKC400U SLIDING GATE OPENER OWNER S MANUAL

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

PY600AC Sliding Gate Opener User Manual

Bringing Component Parts Together

Figure 3-9. Right-Hand Port Connector Configuration. 1. Remove electrical power to the Hydraulic Control Unit.

Commercial Garage Door & Gate Operators

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

GLM SERIES CONTROL Users Manual Rev:

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Sectional And Tilting Door Opener

INSPECTIONS AND MAINTENANCE

Fincor Series 2230 MKII/2240

INSTALLATION M ANUAL

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

HAN-L62 MOUNTING PLATE

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Section A1. Vehicular Gate Operators. This Price Schedule is effective June 1, Date Page Comment All June, 2016 Price Schedule update.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Auto Gate System. General Description. Features EL-888A. elock EL-888A is an electro-mechanical complete system for. EL-888A (Auto gate)

Beaver Power Factor Correction Capacitors

GCL-GT HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR

Installation and Maintenancee Manual

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

YG101 SWING GATE OPENER OWNER S MANUAL

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Capacitor Switching Contactors Type K3...-A, K3...-K

MCC Automatic Start-Stop Microcomputer Charger Control

LI-2B Installation Manual

The House of Gate Automation

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

OmniLogic Main Circuit Board (HLX-PCB-MAIN)

SECTION MOTOR CONTROL

FEATURES Charges two 6- to 8-cell NiCd/NiMH battery packs simultaneously Fully automatic operation Multi-color LEDs indicate state of charge at a

H30. H30 style Roger Technology conceived with logic ROGER TECHNOLOGY

Application Engineering

JARD by MARS JARD by MARS

Installing the gate post bracket with the cardboard arm template

Application Engineering

D-FORCE1500PV GARAGE DOOR OPENER

APOLLO Gate Operators, Inc.

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

ADJUSTABLE FREQUENCY CRANE CONTROLS

www MK-Electronic de EPSON LQ2170 Spares Guide Version 3 Page 1

Insert Residential Opener Tab Here

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

MaxPak Plus Analog DC V S Drive

ARTICULATED ARM GATE OPENER USER MANUAL

ELECTRICAL. CDTA Technical Training Center

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

CONTROL FEATURES AVAILABLE OPTIONS

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

MCU/MCU+ 550(22) & 550(23) SERIES CONDENSING UNITS (Metal Lid)

LPT50BRD (8x11x3 Enclosure)

BARRY BARRIER GATE AUTOMATION

USING WEATHERLINK FOR ALARM OUTPUT Application Note 29

SM361 RIG SWITCH CONSTRUCTION MANUAL

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Sliding Gate Operator User's Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

6002 swing gate actuator - installation guide

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Power Supply EL

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Instruction Manual for the. E-SL 450 Series

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

3 Slot Payphone Controller

EMERGENCY VEHICLE BATTERY MANAGER PS2024

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

XENON POWER SUPPLY 4000 Watt Gladiator IV

VEHICULAR DC SWING GATE OPERATORS. Residential Light Industrial. Rev. 3/17

RAMSET RAM

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

SWING GATE OPENER SW300 SERIES

WIRING THE HEATER POWER SUPPLY

ES50M-65N TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN

Transcription:

SLD Slider Control Board ELSEMA Features For Single 240VAC Motor Built-in transformer, auto close, open only, security close & special security close Application Control an automatic door or gate with 240VAC motor & limit switches Description The SLD is similar in features to the COBO30. The difference is that the SLD is made for a single 240VAC motor and does not have an electronic lock output. This makes it more economical to use the SLD when a single 240VAC motor is used. The SLD has a built-in transformer, autoclose, open only, security close and special security close. The SLD card is used to control automatic door/gate that has a 240VAC motor with limit switches. It is used for a single door or gate. The SLDE is the SLD with an enclosure (C220) and motor capacitor (10uF). The SLD has a built-in wireless operation with a remote control transmitter, push button, down only, photocell control, limit switch connection and 24VAC Output. Options, Auto Close, Open Only, Security Close and Special Security Close are user selectable using the on board 4-way dip switch. See table below: Switch on 4-way code switch ON OFF Enables Auto Close Disables Auto Close Enables Auto Close and Open Only Enables Auto Close, Open Only and Security Close Auto Close, Open Only and Special Security Close Enables Open Only Disables Auto Close and Open Only Disables Auto Close, Open Only and Security Close Disables Special Security Close Disables Open Only Enables Open Only and Security Close Disables Open Only and Security Close

Auto Closing Enabled when switch 1 is on. The AC timer can be adjusted from 3 to approximately 60 seconds by the on board trimpot called AC. Auto Close timer starts when the door is opened and stopped. Input from the Photo Cell terminal will hold-off the closing cycle. Open Only Enabled when switch 2 or 1 and 4 are on. This feature enables the user to open the door/gate but when the door/gate is opening the remote control is disabled and the door will fully opened. Door closes when auto close timer expires. Security Closing Enabled when switch 3 is on. The door/gate immediately closes after the photo beam is broken and the vehicle moves away from the photo beam, even if the door/gate is not fully open. If the door/gate is opening and no vehicle passes through the door/gate then Auto Close will close the door/gate. An Auto Close time of 3 to 60 seconds can be set on the SLD board using the trimpot marked AC. Special Security Close Enabled when switch 4 is on. Same as Security Close except door does not reverse to open when Photo beam is broken. This is to prevent car-tailing on more secure sites. Replaceable Fuse Replaceable 240VAC 5Amp fuse. Other Features Safety Feature The SLD has a built-in switch off protection. The motor will switch-off after 60 seconds on continuous running. This is called the maximum run timer.

SLDE Single 240V Motor Drive Controller with Case ELSEMA The SLDE is with an enclosure. The enclosed unit includes Elsema s C220 box, 10uf motor capacitor and the SLD card.

WIRING AND INSTALLATION INSTRUCTIONS Care should be taken not to cross printed circuit board with 240V wires over or under the board. This would induce spikes onto the sensitive circuitry of the printed circuit board. When SLD PCB is used to switch contactors (see warning note below), a VDR (Voltage Dependent Resistor 275V AC) must be connected across the coil of contactor. Warning Note When connecting contactors directly to the card you must removed the motor capacitors from the cards capacitor terminal blocks. Motor capacitor should be connected directly to the motors. The motors should also have a thermal overload. Wiring Connections Antenna The antenna connection is used to connect an antenna for the plug in FMR-201 or GLR2701SS. The antenna can be a 50 ohms 27 MHz CB-Antenna or piece of approximately 1 metre of wire. Push Button Input Push button is a normally open contact. When pressed it will start the opening or closing cycle. This push button should be waterproof for internal and external use. Waterproofing will prevent false activations, which normally occurs due to moisture inside the button. Door or gate can be held open permanently when push button is pressed continuously.

Down Only Input Down only input is a normally open contact. This is a push button input. When pressed it will start closing (down) the door/gate. The down only push button input will never open (up) the door; it will always close the door/gate. Photo Cell Input Photo Cell input is normally closed contact. The photocell is used as a safety feature. If the motor is closing and photo beam is broken, motor will stop instantly and then open fully. Should an object be blocking the motor (i.e. photo cell is broken), closing cycle or auto closing is disabled. A red LED on the controller card labeled as PC indicates photo beam is broken. A handy feature when photocell is not near the box. Limit Switches The limit switches are normally closed. SLD uses a three wire configuration of limit switches, use two outside holes of terminal block and middle (positive) of the limit switch terminal block (see wiring diagram). Low voltage wiring (24V) can be used for the limit switches. 24 Volts AC Output This terminal is used to supply an external device, such as a Loop Detector or photocell that uses 24 VAC. This output can source 100mA. Cap Motor starting capacitor (10μF) should be connected to this terminal. This capacitor value depends on motor specifications by the manufacturer. Motor Motor should be rated for 240 VAC. The motor should have three wires, i.e. two actives and one neutral. One active is for opening and the other is for closing. Power Connect 240 VAC to the terminal block marked N A. N is neutral and A is active. Remote Control Remote control is achieved by inserting Elsema s FMR-201, GLR2701SS or GLR43301SS. Power to the SLD printed circuit board should be switched off during the installation of a receiver. The transmitter can be an FMT- 301, GLT2701 or GLT43301 respectively. Technical Data Current Consumption: PCB Dimension 40mA with relay activated 10mA Standby 163 X 94 X 42 mm Mounting Hole Size 3.97 mm or 5/32" Mounting Hole Spacing Length 156 mm Width 85 mm