Certificate: _01 / 29 April 2014

Similar documents
Certificate: / 22 March 2013

Certificate: / 22 March 2013

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

Certificate: TNU112UML0348/ Test report: 112UML0348 / of 14 January 2013

Certificate: _01 / 20 August 2013

Confirmation: / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

PRODUCT CONFORMITY CERTIFICATE

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

Air Flow Measurement Technologies

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

Analysis of the tyre choice for noise emission measurements within the context of vehicle type approval and COP compared to on road operation

Superstatic 440. Static Heat- and Cooling Meter. Application

Sound-absorbing spacer Sorp10

Online data sheet FLOWSIC100 VOLUME FLOW MEASURING DEVICES

Pumps and pumping units SL i & Micro C

GMD 13 New gravimetric measuring system with evaluation on location

Series 3730 Electropneumatic Positioner Type

Inductive conductivity meter

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report

(Text with EEA relevance)

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

TÜV RHEINLAND ENERGIE UND UMWELT GMBH. Report on the assessment of the antibacterial properties of AE DeCont rings with AGXX coating

COMMISSION REGULATION (EU)

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

QUESTION / CLARIFICATION

Auftrags-Nr.: Order No.: Auftragsdatum: Order date: FT Technologies Ltd. (for add. information see page 3)

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

TYPE-CERTIFICATE DATA SHEET

EU Mutual Recognition Technical Requirements

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

one filter having K between 1.5 and 2.5 m -1

Georgia Pacific Crossett Operations Hydrogen Sulfide and Meteorological Monitoring Program

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

Assessing and Enforcing Clean Air Regulations in Germany

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

SITRANS P measuring instruments for pressure

Differential pressure transmitter PASCAL Ci4 Delta P

Docket No. ER June 2018 Informational Report Energy Imbalance Market Transition Period Report Idaho Power Company

DEPARTMENT OF TRANSPORTATION. Commercial Driver s License Standards: Application for Exemption; Isuzu North

DEPARTMENT OF TRANSPORTATION. Commercial Driver s License Standards: Application for Exemption; Daimler Trucks North America (Daimler)

Evaluation Certificate

DEPARTMENT OF HEALTH

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

European Aviation Safety Agency

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Mini Pressure Transmitter HA7

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

ISCC s Risk based Certification Approach for Waste and Residues

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

AVL CONTINUOUS FUEL BALANCE

Certificate of Accreditation

Differential pressure transmitter PASCAL Ci4 Delta P

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA),

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Title: Terms and Conditions for the Approval of Coriolis Liquid Meters. Effective Date: Page: 1 of 9 Revision: 1

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

VITLAB Dispenser. Standard Operating Procedure (SOP)

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Ride-on lawnmowers (combustion engine powered)

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Design and Optimization of Contra-Rotating Fans Oliver Velde #, Christian Friebe &, Marius Korfanty #

Inductive conductivity meter

Industry 4.0 Is Unthinkable Without Calibration!

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

FUNCTIONAL SAFETY CERTIFICATE

Tillers Motor hoes (combustion engine powered)

AVL PLU 131U FLOW METER

Panel-mounted Thermostats

Declaration of Conformity as per Directive 97/23/EC

EC Type-Approval Certificate UK 2655 Revision 2

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Marine Shaft Power Meter Product Overview

Intelligent Positioner

Continuous level sensor NSK

AirPort MD8 Battery-Power, Portable Air Sampler

ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions

National comparison on verification of fuel dispensers

Parts Certificate Certificate for a part of a measuring system for LOTW

Data Sheet Calibration / Testing. calibration flat rate not included Type Description Article No. Visual inspection, cleaning, performance

Method Implementation Document (MID)

Influence of mounting tube diameter on anemometer output

Electronic flow switch With display, for liquid media Model FSD-3

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

WELMEC European cooperation in legal metrology

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

Determination of Safety-Relevant Data of Niobium

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

European Technical Assessment ETA-13/0900 of 10/04/2014

Certificate of EC type-approval of a measuring instrument Number: UK 2489 Revision 4

Transcription:

Test report: 936/21219344/B of 01 October 2013 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 2.1 Approved application The tested AMS is suitable for use at combustion plants according to Directive 2010/75/EU, chapter III, at waste incineration plants according to Directive 2010/75/EU, chapter IV and other plants requiring official approval. The tested ranges have been chosen with respect to the wide application range of the AMS. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a sixmonth field test at a waste incineration plant. The AMS is approved for an ambient temperature range of -20 C to +50 C. Any potential user should ensure, in consultation with the manufacturer, that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: test report 936/21219344/B of 01 October 2013 of TÜV Rheinland Energie und Umwelt GmbH suitability announced by the German Federal Environment Agency (UBA) as the relevant body the ongoing surveillance of the product and the manufacturing process publication in the German Federal Gazette (BAnz AT 01 April 2014 B12, chapter II, No. 2.1, Announcement by UBA from 27 February 2014) qal1.de info@qal1.de page 2 of 6

AMS designation: AccuFlo QAL for velocity Manufacturer: S.K.I. GmbH, Mönchengladbach Field of application: For measurements at plants requiring official approval (Directive 2010/75/EU on industrial emissions, chapter III and IV) Measuring ranges during the performance test: Component Certification range Supplementary ranges Unit Velocity 2-20 2-40 2-60 m/s Software version: LSE-QAL-2.11 Restriction: The lower limit of velocity measurement is 2 m/s. Notes: 1. Following a filter fault with high dust content, the probe must be inspected for contamination and where necessary cleaned. 2. The maintenance interval is three month. 3. There are 4 different probes that differ in profile size. SDF 22, 32 and 50 have a fixed width and variable length. The 4 th type (SDF-50+) changes width upon length adjustment. 4. The designation of the measuring system was changed from SDF 22/32/50 to AccuFlo. 5. Supplementary testing (extension of the maintenance interval, new probe type) to the announcement of the Federal Environment Agency (UBA) of 12 February 2013, Federal Gazette (BAnz) AT of 05 March 2013 B10, chapter II number 2.3). Test report: TÜV Rheinland Energie und Umwelt GmbH, Cologne Report No.: 936/21219344/B of 1 October 2013 qal1.de info@qal1.de page 3 of 6

Certified product This certificate applies to automated measurement systems conforming to the following description: The measurement of the volumetric flow rate is based on the principle of differential pressure in flowing exhaust gas. This is carried out as an in-situ method of measurement by means of a dynamic pressure probe (Type SDF) and a pressure sensor (Model: SITRANS P). The pressure transmitter is connected to the evaluation electronics (μflow 100LSE). There, the calculation of the differential pressure signals by means of exhaust gas boundary conditions (temperature, pressure and density) is carried out. Velocity signals are issued through two 4-20 ma analogue outputs with variable measuring range. The manufacturer, S.K.I. GmbH, produces the probe tube in four different models (SDF-22, SDF-32, SDF-50 and SDF-50+). These differ mainly in their thickness, which defines the maximum length of the probe. Slight differences are found in their geometrical structure. General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 15267. The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, TÜV Rheinland Energie und Umwelt GmbH must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This can be applied to the product or used in publicity material for the certified product. This document as well as the certification mark remains property of TÜV Rheinland Energie und Umwelt GmbH. With revocation of the publication the certificate loses its validity. After the expiration of the certificate and on requests of the TÜV Rheinland Energie und Umwelt GmbH this document shall be returned and the certificate mark must not be employed anymore. The relevant version of this certificate and its expiration is also accessible on the internet: qal1.de. qal1.de info@qal1.de page 4 of 6

Certification of AccuFlo QAL for velocity is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: Initial certification according to EN 15267 Certificate No. 0000038500: 22 March 2013 Expiry date of the certificate: 04 March 2018 Test report: 936/21219344/A of 08 October 2012 TÜV Rheinland Energie und Umwelt GmbH, Cologne Publication: BAnz AT 05 March 2013 B10, chapter II, No. 2.3 Announcement by UBA from 12 February 2013 Supplementary testing according to EN 15267 Certificate No. 0000038500_01: 29 April 2014 Expiry date of the certificate: 04 March 2018 Test report: 936/21219344/B of 1 October 2013 TÜV Rheinland Energie und Umwelt GmbH, Cologne Publication: BAnz AT 01 April 2014 B12, chapter II, No. 2.1 Announcement by UBA from 27 February 2014 qal1.de info@qal1.de page 5 of 6

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer S.K.I. GmbH AMS designation AccuFlo QAL Serial number of units under test 12048607 / 12048608 Measuring principle differential pressure measurement Test report Test laboratory Date of report 936/21219344/A TÜV Rheinland 2012-10-08 936/21219344/B 2013-10-01 Measured component Velocity Certification range 2-20 m/s Calculation of the combined standard uncertainty Tested parameter u² Standard deviation from paired measurements under field conditions * u D 0.280 m/s 0.078 (m/s)² Lack of fit u lof 0.081 m/s 0.007 (m/s)² Zero drift from field test u d,z 0.046 m/s 0.002 (m/s)² Span drift from field test u d,s 0.127 m/s 0.016 (m/s)² Influence of ambient temperature at span u t 0.115 m/s 0.013 (m/s)² Influence of supply voltage u v 0.025 m/s 0.001 (m/s)² Uncertainty of reference material at 70% of certification range u rm 0.162 m/s 0.026 (m/s)² * The larger value is used : "Repeatability standard deviation at span" or "Standard deviation from paired measurements under field conditions" å ( ) Combined standard uncertainty (u C ) u c = u max, j 0.38 m/s Total expanded uncertainty U = u c * k = u c * 1.96 0.74 m/s 2 Relative total expanded uncertainty U in % of the range 20 m/s 3.7 Requirement of 2010/75/EU U in % of the range 20 m/s 10.0 ** Requirement of EN 15267-3 U in % of the range 20 m/s 7.5 ** For this component no requirements in the EC-directives 2010/75/EU on industrial emissions are given. The chosen value is recommended by the certification body. qal1.de info@qal1.de page 6 of 6