General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

General Purpose ph/orp Sensors

Instruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition

Signet DryLoc ph/orp Electrodes

General Purpose ph/orp Sensors

General Specifications

Instruction Manual YOKOGAWA. Model FD20 Immersion Fittings. ph/orp. IM 12B6K2-01E-E 7th edition

SIGNET 2750 ph/orp Sensor ENGLISH

Signet DryLoc ph/orp Electrodes

Signet 3719 ph/orp Wet-Tap

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Digital ph transmitter

Digital ph transmitter

General Specifications

JUMO tecline HD ph and JUMO tecline HD Rd

ph-kompaktelektrodensystem sensopac CPA 320

SIGNET 3719 ph/orp Wet-Tap

Instruction Manual YOKOGAWA. ph/orp. Model FD20 Immersion Fittings. IM 12B06K02-01E-E 9th edition. IM12B06K02-01E-E_ed09.indd 1 07/03/16 09:51

General Specifications

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

NEW QUICK CABLE-TO-SENSOR RELEASE,

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors

Dissolved Oxygen, ph, and Conductivity

General Specifications

User Manual. Model PD20, PF20 and PS20 Compact ph Probe YOKOGAWA. IM 12B6K4-01E-E 8th Edition

Instruction Manual. Model FF20 Flow fittings. Model FS20 Subassembly flow fittings. IM 12B6K1-01E-E 7th edition

Conductivity Measuring Cells ConduMax W CLS 19

Signet ph/orp Electrodes

Signet ph/orp Electrodes

* * Rev. 9 01/18 Product Manual

Model FF20 Flow fittings. Instruction Manual. Model FS20 Subassembly flow fittings YOKOGAWA. IM 12B06K01-01E-E 10th edition

Signet 3719 ph/orp Wet-Tap Assembly

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

TUpH Retraction/Submersion/Insertion ph/orp Sensors

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

SIGNET 2760 DryLoc ph/orp Preamplifier

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Specifications

General Specifications

Signet ph/orp Electrodes

Technical Information

Orbipore CPS91 and CPS91D

Signet Conductivity/Resistivity Electrodes

Signet 2760 DryLoc ph/orp Preamplifier

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Model FU20 ph/orp Sensor

ph/orp Sensor Model 399 ph/orp

Signet Conductivity/Resistivity Electrodes

Ceraliquid CPS41 and CPS41D

Performance Series ph/orp Sensors

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Model FLXA21 2-Wire Analyzer Start-up Manual

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

General Specifications

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Rosemount 402 and 402VP

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Accessories Guide ph/orp/conductivity Sensors

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

For additional information, please visit our website at SENSOR SPECIFICATIONS

AP200 series Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Orbisint CPS11 and CPS11D

Orbisint CPS11 and CPS11D

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

Signet 515 Rotor-X Paddlewheel Flow Sensors

Conductivity Sensors. Applications

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes

Personal ph, ph/orp, Conductivity Meters

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Conductivity Measurement CLM 280

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

7777 Immersion/In-Line Mounting for Meredian II ph/orp Electrodes Installation and Maintenance Manual

Performance Series ph/orp Sensors

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

Analytical Instruments Two-Electrode Conductivity Sensors

FIELD DEVICES ANALYTICAL

Differential Pressure Gauges (701P Series)

Insertion/Submersion Flow Through Sensor

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Signet 4150 Turbidimeter

Retractable ph/orp Sensors

SATRON VDt Differential Pressure Transmitter

Pasve Rotary Retraction Valve

ScienceLine ph combination electrodes

Instruction. MI September PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance

Model Q45H/ Residual Chlorine Monitor...

Transcription:

General Specifications Model PH20, FU20 and FU24 4 in 1 ph sensor GS 12B6J3-01E-A Yokogawa s family of wide body sensors is suited for a wide variety of processes. The sensors share the same unique features: Long life double junction Ag/AgCl reference system with polymerized saturated KCI fill including AG + ion trap. PTFE reference diaphragm to prevent fouling and reduce measurement error. Integral Pt1000 element for accurate temperature measurements Double junction combined with ion-trap to prolong the life of the reference probe even in chemically unfavorable environments. Platinum ORP/LE electrode for accurate simultaneous ph and ORP measurements. Versatile in-line, immersion or off-line installation. Polymerized electrolyte to extend the sensors life time. For general purpose applications the FU20 is the sensor of choice: The FU20 combination sensor exemplifies Yokogawa motto, Simply the Best sensor technology. The wide body sensor (26 mm diameter) holds four separate measuring elements in one unbreakable and chemical resistant PPS 40GF (RytonTM) body. Installation is simple with the integrated industrial 3/4 tapered thread. Temperature fluctuations are compensated for extending sensor life. The FU20 is targeted at those applications where simplicity, accuracy and reliability are required for ph or redox(orp) measurements. This means that in 90% of the known applications this sensor will be an excellent choice. For more difficult applications the FU24 sensor will be the better choice: The FU24 is also made with a chemical resistant PPS 40GF body. It is particularly useful in harsh applications with fluctuating pressure and/or temperature. These processes shorten sensor life because the process fluids move in and out of the sensor under influence of frequent pressure and/or temperature fluctuations. This results in fast desalting and dilution of the reference electrolyte which in turn changes the reference voltage causing a drifting ph measurement. By incorporating the successful Yokogawa patented Bellow system integrated in the FU24 electrode, a strong pressure compensation mechanism is created. The built-in bellow ensures immediate interior pressure equalization to the outside pressure, making the sensor virtually insensitive to external pressure variations. System Configuration A slight overpressure caused by the bellow tension, prevents fluid ingress and maintains a positive ion flow out of the sensor. This feature is of particular interest in pure water applications. In applications where chemical resistance is a vital issue the PH20 will be the choice: The PH20 body is made of chemically resistant PVDF. The sensor is nicknamed Tempress because of the patented compensation for changes in the process temperature and pressure. A simple mechanical feature makes the sensor more accurate, and gives it a longer lifetime. The compensation panels flex to accommodate changes in pressure and temperature, thus avoiding large differential pressures across the diaphragm. This prevents most problems associated with the reference junction. Both FU20 and FU24 are also available with VP connector. This makes installation easier. All sensors are delivered with a Quality Certificate. Sensors Cables Fittings Transmitters Accessories Yokogawa Corporation of America 2 Dart Road, Newnan, Georgia U.S.A. 30265 Tel: 1-800-888-6400 Fax: 1-770-254-0928 GS12B6J3-01E-A Copyright 13th Edition

2 General Specifications FU20 General specifications FU24 Measuring elements : ph glass electrode : Silver chloride reference system : Platinum electrode : Pt1000 temperature sensor. Measuring elements : ph glass electrode : Silver/Silver Chloride reference : Solid Platinum electrode : Pt1000 temperature sensor. Construction materials Body Earthing pin O-ring Reference junction Cable Sheet material Measuring Sensor : PPS 40GF (glass filled Ryton) : Solid platinum : None : Porous PTFE : Coaxial with 4 extra leads : Thermoplastic rubber : G-Glass Functional specifications (at 25 C) Isothermal point : ph 7 Reference system : Ag/AgCl with saturated KCI Glass impedance - Dome shape : nominal 200MΩ, G-glass - Flat Surface : nominal 700MΩ, G-glass Junction resistance : 1 to 10 kω Temperature element : Pt1000 to IEC 751 Asymmetry potential : 8 ± 15 mv Slope : > 96 % (of theoretical value) Dynamic specifications (at 25 C) Response time ph step (7 to 4) : < 15 sec for 90% Response time temp step (10 C) - Dome shape : < 1 min for 90% - Flat surface : < 1.5 min for 90% Stabilisation time (0.02 ph/10 s) : < 2 minutes Operating range ph : 0-14* Temperature : -10 to 105ºC (14 to 221 F) Pressure : 0 to 10 bar ( 0 to 145 PSIG) Conductivity : > 50 µs/cm Storage temperature : -10 to 50ºC (-22 to 122 F) * The ph range at room temperature is 0-14 ph, but at high temperatures the lifetime will be seriously shortened outside 2-12 ph range. Construction materials Wetted materials: Body : PPS 40GF (glass filled Ryton) O-ring : Viton Earth Pin : Solid platinum Reference Junction : Porous PTFE Measuring Sensor : G-Glass Functional specifications Isothermal point : ph 7 Glass impedance Dome shape : nominal 200 MΩ Flat Surface : nominal 700 MΩ Reference system : Double junction, Ag/AgCl with saturated KCI, including Ag + ion trap Junction resistance : 1 to 15 kω Temp. element : Pt1000 to IEC 751 Asymmetry potential : 8 ±15 mv Slope : > 96 % (of theoretical value) Note: The temperature sensor included in the FU24 is intended to provide indication and cell compensation. The construction has not been tested to the pressure vessel standards required for plant temperature control. Dynamic specifications Response time ph step (7 to 4) : < 15 sec for 90% Response time temp step (10 C) Dome shape : < 1 min for 90% Flat Surface : < 1.5 min for 90% Stabilization time (0.02 ph unit/10 s) : < 2 minutes Operating range ph : 0 to 14 Temperature : -10 to 105 C (14 to 221 F) Pressure : 0 to 10 bar (0 to 145 PSIG) Storage temp. : -15 to 50 C (5 to 122 F) Note: The FU24 is suitable for pure water applications. Note: Specifications should not be considered in isolation. For example the ph range can be 2-12pH, where the measurement is at elevated temperatures. For advice about specific applications please contact your local sales office.

3 General Specifications PH20 Measuring elements Construction materials Body Earthing pin O-ring Reference junction Cable Sheet material Measuring Sensor : ph glass electrode : Silver/Silver chloride reference system. : Platinum electrode : Pt1000 temperature sensor. : PVDF : Solid platinum/glass : Viton : Porous PTFE : Coaxial with 4 extra leads : Thermoplastic rubber : G-Glass Functional specifications (at 25 C) Isothermal point : ph 7 Reference system : Ag/AgCl with saturated KCl Glass impedance : 200 MΩ (nominal), G-glass Junction resistance : 1 to10 kω Temperature element : Pt1000 to IEC 751 Asymmetry potential : 8 ± 15 mv Slope : > 96 % (of theoretical value) potential (m V) -180-200 -220-240 -260-280 -300 Pressure Effects on sensor mv Pressure Conventional Sensor Tempress 200 250 time (min)> 300 The erratic trend of the standard sensor shows the progressive contamination of its reference junction. The graph indicates between 0.1 to 0.4 ph error with the conventional sensor while the readings from the PH20 are extremely stable. 15 10 5 0 pressure (bar) Dynamic specifications (at 25 C) Response time ph step (7 to 4) : < 5 sec for 90% Response time temp. step (10 C) : < 1 min for 90 % Stabilisation time (0.02 ph/10 s) : < 1 minute Operating range ph : 0-14* Temperature : -10 to 105ºC (14 to 212 F) Pressure : 0 to 10 bar ( 0 to 142 PSIG) Conductivity : > 50 µs/cm Storage temperature : -10 to 50ºC (-22 to 122 F)

4 Dimensions FU24 71.0 56.4 71.0 193.0 254.2 1 NPT 1 NPT 178.4 239.6 1 NPT 1 NPT 193.0 231.5 1 NPT 1 NPT 28.0 33.3 28.0 33.3 28.0 33.3 Unit: mm

Ø 22.0 (0.86) 5 Dimensions Dimensions FU20 FU20 Adapter ø 35.5 (1.4") 3/4 TAPERED THREAD 3/4 TAPERED THREAD -NPT PG7 PG7 19.7(0.78 ) 1 NPT or ISO 7/1-R1 19.7 (0.78 ) 22.5 (0.89 ) (/NSS /NTI) 1" NPT or ISO 7/1-R1 (/BSS /BTI) ø 39.0 (1.54") 25.0 (1") 99.0 (3.9") 51.0 (2.3 ) /NSS, /NTI, /BSS, /BTI 150.0 (5.9 ) PG7 -FSM 10.0 (0.39 ) Dimensions FU20 (Temp) Red F (Temp) Blue E (ph shield) Yellow C ø6.5 (ph) Clear A MODEL CODE Serie nummer 63 FU20-VP- (Ref.) Brown B (ORP/LE) Black D FU20-NPT with VP connector ø20.5 225 150 187 PH20 Ø 22 (0.86") ISO 228/1-G3/4 ISO 228/1-G3/4 90 (3.54") 170 (6.70") 190.4 (7.50") 220.5 (8.68") Unit: mm (inches)

6 Installation examples using the FU20 adapter range FD40 also for FF40 and FS40 FF40 example Nut O-ring Adapter ( /FPS or K1523DD) Fitting FU20 O-ring Adapter ( /FPS or K1523DD) FU20 O-ring

35.0 (1.38 ) 5.0 (0.2 ) 7 FS20/FF20 installation example for FU24 + adapter Ø 30.0 (1.18 ) 22 mm 10.0 (0.4 ) Ø 30.0 (1.18 ) Ø 36.0 (1.42 ) K1521JA FS20-S32-TP Dimensions Ryton adapter for FF40, FS40 and FD40 fittings (/FPS or K1523DD) for use with FU20. Note: old part K1523DC is not compatible with VP connector and sensors manufactered after December 2009. FU20 + adapter ( ie K1547PK) K1521JA FS20-S33*B

8 Installation examples using the PH20 adapter range Ø 36.0 (1.42") Sensor cable Ø 30.0 (1.18") Plug-in sensor /SF4 adapter 25.2 (1.0") 45 (1.77") ISO 228/1-G3/4" 1" NPT /FN4 (1 NPT) and /FR4 (1 ISO 7/1-R1) Ø 36.0 (1.42") Ø 30.0 (1.18") ISO 228/1-G3/4" FS40-S22-WE 20.0 (0.8") 25.2 (1.0") 45 (1.77") 3/4" NPT /SN3 (3/4 NPT) and /SR3 (3/4 ISO 7/1-R) Front- and backend mounting in the FF40 FS40-S22-TP Using the /SF4 adapter, the PH20 can be mounted in the standard range of conductivity flow fitting (FF40..), the immersion fittings (FD40-..) and sub-assemblies (FS40..). The adapter can be mounted on the front thread, or the back thread dependent on the required insertion depth. adapter options PH20 / 3: 3/4 4: 1 N: NPT R: ISO 7/1-R1 F: PVDF S: Stainless steel Unit: mm (inches) Ø 36.0 (1.42") O-rings (2x) ISO 228/1-G3/4" Ø 30 (1.18") 15 (0.6") 30 (1.18") /SF4. Adapter for FF40, FS40 and FD40 fittings 15º Minimum Direct mounting with an adapter /FN4, /FR4, /SN3, /SR3

9 Model and Suffix codes Model code Suffix code Option code Description FU20 Wide body sensor -VP Variopin connector Cable length -03 3 meter -05 5 meter -10 10 meter -20 20 meter Temp. element -T1 Pt1000 Model -NPT Dome shape model -FSM Flat surface model Options /HCNF Hastelloy cleaning system, or spare part number K1547PJ /FPS Adapter F*40 from noryl, or spare part number K1523DD /NSS 1 NPT adapter, SS (316L), or spare part number K1547PK /NTI 1 NPT adapter, Titanium, or spare part number K1547PM /BSS 1 BSP adapter, SS (316L), or spare part number K1547PL /BTI 1 BSP adapter, Titanium, or spare part number K1547PN Model code Suffix code Option code Description FU24 Combined ph sensor Sensor -05 5m fixed cable connection -10 10m fixed cable -VP Variopin connector Temperature sensor -T1 Pt1000 Sensor tip -FSM Self cleaning, flat surface -NPT Heavy duty, dome shaped Reference system - N Non-flowing Accessories K1521JA Adapter to place into F*20 assemblies, 316SS K1521JB Adapter to place into F*20 assemblies, PVDF Model code Suffix code Option code Description PH20 4-in-1 ph sensor Material -F PVDF Membrane -G Dome shaped Cable length -02 2 meter -05 5 meter -10 10 meter -20 20 meter -30 30 meter Temp. element -T1 Pt1000 -N -A Always -N -A Options /SN3 Stainless steel 3/4 NPT adapter (316L), or spare part number K1541QA /SR3 Stainless steel 3/4 R adapter (316L), or spare part number K1547QB /FN4 PVDF 1 NPT adapter, or spare part number K1547PC /FR4 PVDF 1 R adapter, or spare part number K1547PD /SF4 Stainless steel adapter for FF40, FS40 and FD40 fitings, or spare part number K1547QF /HCNF Hastelloy cleaning system - when no fitting used, or spare part number K1547PJ /HCN2 When FF20 or FS20 are used, or spare part number K1547PA Model code Suffix Code Option code Description WU10 Sensor cable Connector type -V Variopin Cable type -S Single Coax Cable length -02 2 meters -05 5 meters -10 10 meters -15 15 meters -20 20 meters

10 Spare parts PH20, FU20, FU24 & cleaning system Part no. Description K1500EK O-rings Viton 6.07x1.78 (5x2) K1500ER O-ring set Viton FF20-S22 K1511DP O-rings Viton 21.9x2.62 (5x2) K1511DQ O-rings EPDM 21.9x2.62 (5x2) K1521JA SS adapter for FU24 for us in F*20 holder K1547PC /FN4 for PH20 K1547PD /FR4 for PH20 K1547PE /PH8 for PH20 K1547PG Nozzle and mounting HCN4 K1547PP Spare Part EPDM spraying valves K1547QA /SN3 for PH20 K1547QB /SR3 for PH20 K1547QF /SF4 for PH20 K1500FR O-rings Viton 29.82x2.62 (5) K1500FS O-rings EPDM 29.82x2.62 (5) K1500FT O-rings Silicone, 29.82x2.62 (5) K1520ZD Mounting nut for PH20 K1523DD /FPS, FU20-mounting in F*40 K1547PK Adapter 1 NPT, SS 316 for FU20 K1547PL Adapter 1 BSP, SS 316 for FU20 K1547PM Adapter 1 NPT, Ti for FU20 K1547PN Adapter 1 BSP, Ti for FU20 K1547PJ Hastelloy cleaning unit HCNF K1547PF Nozzle and mounting HCN2/3/F Spare Parts Prod. No. Description M1100EU Starters Kit: (3x 500 ml) Buffer Solutions ph 4.01 / 6.87 / 9.18 M1263VM Buffer Solution ph 4.01, 1 Gallon M1263VN Buffer Solution ph 6.87, 1 Gallon M1263VP Buffer Solution ph 9.18, 1 Gallon Connection equipment BA10 Junction box for ph extension cables WF10-xxx-F ph signal cable with terminated ends. Specify length in whole meters WU10-V-S-XX Variopin cable Cleaning system for FU20 & PH20 FU20 K1547PH Some applications require frequent cleaning of the electrode. For these applications Yokogawa designed a chemical cleaning system that can either be used in the Yokogawa fitting range (HCN2, HCN3 or HCN4) or as back-end mounting option for the PH20 and FU20. The /HCNF option comes with a hastelloy cleaning nozzle, Stainless steel mounting and ferrules sets and a nylon tube of 10 meters. K1547PF Option /HCNF

11 Wiring of the PH20 / FU20 / FU24 Conventional ph (& ORP) wiring Connect the cable versions PH20, FU20 or FU24 to the EXA or EXAxt PH analyzer as shown. With this configuration, it is possible to measure ORP (or rh) at the same time (Refer to the EXA or EXAxt manual for appropriate impedance jumper and Service Code settings). ph (& ORP) WIRING DIAGRAM Color Callouts are only for when using a Variopin Cable. Number Callouts are for integral Cable. Red 11 Blue 12 Brown13 Blk 14 Clear15 Yellow 16 (11) (12) (13) (17) (14) (15) (16) T2 TEMPERATURE T1 TEMPERATURE RE REFERENCE REFERENCE SCREEN SE SOLUTION GROUND GE GLASS (Measure) S GLASS SCREEN Wiring for ORP measurement with normal reference Connect the PH20, FU20 or FU24 to the EXA PH analyzer as shown. Refer to the EXA manual for appropriate impedance jumper and Service Code settings. ORP WIRING DIAGRAM with normal reference Red 11 Blue 12 Brown 13 Jumper Black 14 16 15 (Not used) (11) (12) (13) (17) (14) (15) (16) T2 T1 RE SE GE S TEMPERATURE TEMPERATURE REFERENCE REFERENCE SCREEN SOLUTION GROUND Pt (ORP Measure) GLASS SCREEN Wiring for ORP measurement with ph reference Connect the PH20, FU20 or FU24 to the EXA Glass PH analyzer as shown. Refer to the EXA manual for appropriate impedance jumper and Service Code settings. ORP WIRING DIAGRAM with ph sensor as reference Red 11 Blue 12 Clear 15 16 Yellow Blk 14 13 (Not used) Jumper (11) (12) (13) (17) (14) T2 T1 RE SE TEMPERATURE TEMPERATURE REFERENCE (ph) REFERENCE SCREEN (SOLUTION GROUND) (15) GE Pt (ORP Measure) (16) S GLASS SCREEN

Yokogawa Corporation of America North America 2 Dart Road, Newnan, GA 30265-1094, USA Phone: 800-888-6400 Fax: 770-254-0928 12530 West Airport Blvd., Sugar Land, TX 77478 Phone: 281-340-3800 Fax: 281-340-3838 Yokogawa has an extensive sales and distribution network. Please refer to the website (www. yokogawa.com/us) to contact your nearest representative. Mexico Melchor Ocampo 193, Torre C, Oficina 3 B Veronica Anzures D.F., C.P. 11300 Phone: (55) 5260-0019, (55) 5260-0042 Yokogawa Canada, Inc. Bay 4, 11133 40th Street SE, Calgary, AB Canada T2C2Z4 Phone: 403-258-2681 Fax: 403-258-0182