TM-9100 Series Room Command Module

Similar documents
TM-11x1 Series Room Temperature Module

SEN and SEN Outdoor Air Temperature Sensors

System 350 P352AB Electronic Pressure Control Series

D-4070 Two Stage Pneumatic Actuator

VA-8020 Floating Valve Actuator

YCCS TE-6800 Series Temperature Sensors

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

A25 Series Warm Air Control with Manual Reset

AV-8020 Series Floating Control Actuated Valve

M9216 Series Electric Spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

TE-6300 Series Temperature Sensors

System 350 S350P Proportional Plus Integral Temperature Stage Module

M x Series Valve Linkage Kits

Damper Actuator Installation

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

TE-6001 Hardware Assemblies for TE-6000 Temperature Elements

TE-6300 Series Temperature Sensors

EP-8000 Series Electro-Pneumatic Transducers

VA-715x Electric Valve Actuator

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

VA-7450 Series. Electric Valve Actuators

M100F Incremental Motor Actuator R81F Interface Board

S-2300 Pneumatic Selector Switch

MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors

A419ABG-3C Electronic Temperature Control

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications

P70, P72, and P170 Controls for Low Pressure Applications

G76x Direct Spark Ignition Controls

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

VA-715x Electric Valve Actuator

R81EAA-2 Economizer Circuit Board

VA-720x Electric Valve Actuator

ATP-2040 Electric Damper Actuator/Transmitter

Q35 Series Automatic Vent Damper System

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

Barbara, Here is the list of items. I numbered the attachments to match with the numbers below.

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

System 350 S350C Temperature Slave Stage Module

P445 Series Electronic Lube Oil Control

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

Series Y63, Y64, Y65, Y66, and Y69 Transformers

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

VA-4233-GGx Series Electric Valve Actuators

Metasys Zoning Package

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

M9210-xxx-3 Electric Spring Return Actuators

Universal Packaging Module (UPM)

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Digital Room Thermostats with Touch Screen LCD

DPS/MPS/RAH/RPS/SWP Space Sensor

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

TS , -850 Series TS , -850 Series TS-57031, TS

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

System 350 A350E Electronic Cooling Control

Flare Valves 1/2 inch 2-Way and 3-Way

P66 Series Electronic Fan Speed Controls

BAPI-Stat 3 Room Sensor

EDA-8100 Electric Damper Actuator

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

Metasys Zoning Package Installation

G861 Series Integrated Function. Direct Spark Ignition Control

M9220-xxx-3 Electric Spring Return Actuators

Y75 Series Sensing Probes

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

M9300 Series Potentiometer Kits

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

G72x Series Direct Spark Ignition Controls

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

T100A,F,M Controllers

M9300 Series Switch Kits

R-317 Air Flow Controller

M Remote Mounting Kit

VG7000 Valve Linkage for M100 Series Motor Actuators

V46 Series Pressure-Actuated Water-Regulating Valves

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

A11 Series Low Temperature Cutout Control

Operating the Network Control Module (NCM) Battery Charger/Tester

M9109 Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

G600 Series Replacement Intermittent Pilot Ignition Controls

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

Metasys Zoning Package Overview

P70, P72 and P170 Series Controls for High Pressure Applications

SERIES 700 ANALOG ELECTRONIC CONTROLS

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

TK-6024, TK-6124, TK-8024, TK-8124

F61 Series Standard Flow Switches

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Manual Flushing. I nspection and Service

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Y20EBA Linkage Kit, M100 to Barber-Colman 1/2 to 1-1/4 Inch Valves

Transcription:

FANs 216, 1628.3 Product/Technical Bulletin TM-9100 Issue Date 0400 TM-9100 Series Room Command Module The TM-9100 Series Room Command Modules are designed for use with the TC-9100 series of DDC (Direct Digital Control) terminal unit controllers. The setpoint dial enables the room occupant to adjust the setpoint of the controller within the range of 55 to 85 F, +/-5 F, 12 to 28 C, or +/-3 C. The Temporary Occupancy button enables the occupant to change the controller mode manually. The status of the controller is indicated by an LED (Light-Emitting Diode) indicator on the TM-9100. There are four room command modules with a 3-speed fan selector. Refer to Ordering Information at the end of this bulletin for details of all models available. Figure 1: TM-9100 Series Room Command Module Shown with and without Setpoint Dial Features and Benefits High Accuracy Thermistor Sensor Choice of Setpoint Dials Adjustable Setpoint Limits Temporary Occupancy Button Optional Fan Speed Selector External LED Mode Indicator Choice of Wallbox Mounting Base (included with all models) Provides a low-cost alternative to expensive metal alloy sensors Provides aesthetic flexibility Provides limits to user setpoint adjustment range Enables the user to adjust room comfort by selecting the controller s mode Allows manual control of the speed of the fan to ensure comfort Shows the controller s current operating status Makes the TM-9100 adaptable for most installations 2000 Johnson Controls, Inc. 1 Part No. 24-8464-2, Rev. B www.johnsoncontrols.com Code No. LIT-216509

Product Overview The TM-9100 Room Command Module is available with a setpoint dial, and must be connected to a TC-9100 series controller with the corresponding remote setpoint range. The 55 to 85 F or 12 to 28 C range model provides remote adjustment of the setpoint of the controller, while the +/-5 F or +/-3 C range model provides remote offset adjustment (deviation to the room temperature setpoint programmed into the controller). The LED, located directly above the Temporary Occupancy button on the TM-9100, indicates the current operating mode of the TC-9100 controller as follows: LED on: Occupied mode (Comfort) LED off: Unoccupied mode (Night) D imensions 3.15 80 60 55 65 70 F 3.15 80 75 AUTO OFF LO MED HI Fan Selector 80 85 Setpoint Dial LED Temporary Occupancy Button 1.29 33 Figure 2: TM-9100 Cover Dimensions, in. (mm) LED flashing: Standby mode Refer to the Facilitator TC-9102 Terminal Controller Technical Bulletin (LIT-1628340) for more information. The TM-9100 Temporary Occupancy button provides a means to circumvent day/night programming and turn the HVAC system on or off manually. If pressed for about a second, the controller mode is changed. Refer to the TC-9102 Applications Application Note (LIT-6375130), Tables 3, 4, and 5 for more information. When connected to a TC-9102 controller, which has a 3-speed fan control auxiliary output, the fan selector allows manual control of the fan speed. The positions of the selector are as follows: AUTO OFF LO MED HI Automatic fan speed set by the TC-9102 controller. Fan off (except when controller is in the low limit protection mode). Fan is low speed. Fan is medium speed. Fan is high speed. Figure 3: TM-9100 Base Dimensions, in. (mm) Figure 4: TM-9100 Wallplate Dimensions, in. (mm) 2 TM-9100 Series Room Command Module Product/Technical Bulletin

I nstallation Install the TM-9100 where the occupant can easily read and adjust the setpoint dial or fan speed selector. Locate the module where the temperature is representative of the general room conditions. Avoid mounting the TM-9100 near cold or warm air drafts, radiant heat, or direct sunlight. IMPORTANT: Parts Included Do not mount the module on an exterior wall. All wiring connections must be made in accordance with the National Electrical Code and all local regulations. room command module with attached surface mounting base separate wallplate for wallbox mounting wallplate endcaps (2) serrated setpoint dial (attached) smooth setpoint dial (separate) dial-stop self-tapping screws (2) hollow plastic wall anchors (2) No. 8 x 1-1/4 in. slotted pan-head sheet metal screws (2) No. 6-32 x 1/2 in. flat-head machine screws (2) Tools Needed 1/16 in. (1.5 mm) Allen wrench or stat adjustment tool screwdrivers, flat-blade, 1/4 in. and 3/16 in. tip screwdriver, Phillips, No. 1 tip 5/16 in. drill bit and drill hammer M ounting The TM-9100 series allows for two mounting methods: surface mount and wallbox mount. For surface mounting, follow the instructions for removing the cover and proceed to the Surface Mounting Procedure section. For wallbox mounting, follow the instructions for removing the cover and proceed to the Wallbox Mounting Procedure section. Note: All TM-9100 models include the U.S. Wallbox Mounting Base Kit. Discard the kit if surface mounting the module. Removing the Cover To remove the cover from the base, insert a 1/16 in. (1.5 mm) Allen wrench or T-4000-119 Stat Adjustment Tool into the small hole located in the center of the top of the cover. While pressing down gently on the tool, pull the cover away from the base until it is free. (See Figure 5.) Insert stat adjustment tool or Allen wrench here. Cover Base Figure 5: Removing the Cover from the Base TM-9100 Series Room Command Module Product/Technical Bulletin 3

Surface Mounting Procedure To surface mount the TM-9100: 1. Pull the wiring through the wall. (See Figure 6.) 2. Place the base against the wall, and mark the screw holes using the base as a template. 3. Drill two 5/16 in. (8 mm) holes, insert anchors, position base, then drive the screws. 4. Wire to appropriate terminals as shown in Figures 16 and 17. No. 8 Screws (2) Wall Anchors (2) Wallbox Mounting Procedure To wallbox mount the TM-9100: 1. Loosen the cover screw installed in the wallplate. 2. Pull the wiring through the wallbox. (These instructions assume a standard 2 x 4 in. [51 x 102 mm] wallbox is used.) 3. Rotate the wallplate so one of the arrows on the wallplate points up. 4. Fasten the wallplate to the wallbox using the No. 6 screws provided. (See Figure 8.) Cover Screw Base Wiring to TM-9100 Drywall Base No. 6 Screws Figure 8: Installing a TM-9100 Using a Wallplate a b b c Figure 6: Installing a Surface-Mounted TM-9100 Reassembling the Surface-Mounted TM-9100 If using the dial-stop screws, proceed to the Dial-Stop Screws section. To reassemble the TM-9100, place the cover against the bottom edge of the base, and push the upper part of the cover until it clicks firmly into place. (See Figure 7.) Figure 7: Reattaching the Cover to the Base Figure 9: Terminal Locations Shown on Inside of TM-9100 Surface-Mount Base Note: The terminal locations on the back of the TM-9100 cover are opposite of those marked on the base. (See Figure 9.) Terminal 14 will be located in the farthest right position of the right terminal block when viewing the inside of the TM-9100 cover as shown in Figure 11. 5. Remove terminal block(s) from the TM-9100 base by lifting the plastic fingers on the back of the base and sliding the terminal block down and out of the retainer. (See Figure 10.) Discard this base. 4 TM-9100 Series Room Command Module Product/Technical Bulletin

Plastic Fingers on the Back of the TM-9100 Base Cover Screw Cover Figure 10: Removing the Terminal Block(s) from TM-9100 Surface-Mount Base 6. Push the terminal blocks onto the pins located inside the TM-9100 cover with screw heads toward the board and the wire leads exiting the terminal blocks from the bottom as shown in Figure 11. Figure 12: Reattaching the Cover to the Wallplate 3. Install the endcaps provided by snapping them onto the wallplate. (See Figure 13.) Figure 13: Installing Endcaps in Wallbox Applications Figure 11: Inside View of TM-9100 Cover Shown with Terminal Blocks Positioned for Wallplate Mounting 7. Wire to appropriate terminals as shown in Figures 16 and 17. Reassembling the Wallbox-Mounted TM-9100 If using the dial-stop screws, proceed to the Dial-Stop Screws section. To replace the TM-9100 cover onto the installed wallplate: 1. Place the bottom edge of the cover against the bottom edge of the wallplate. 2. Rotate the cover up onto the wallplate, and tighten the cover screw using the stat tool or Allen wrench. (See Figure 12.) Dial-Stop Screws A pair of self-tapping screws can be installed to mechanically limit the range of the TM-9100 setpoint dial. (See Table 1.) 1. Remove the base of the module from the cover by inserting a 1/16 in. (1.5 mm) Allen wrench or T-4000-119 Stat Adjustment Tool into the small hole located in the center of the top of the cover. While pressing down gently on the tool, pull the cover away from the base until it is free. 2. Set the dial to the center top position, with the pointer (indentation) at the 70 F (20 C) mark. 3. Insert the stat adjustment tool through the hole in the back of the cover (1) and push gently until the dial knob is released (2). TM-9100 Series Room Command Module Product/Technical Bulletin 5

Setpoint Dial To replace a serrated setpoint dial with a smooth dial, follow Steps 1, 2, 3, and 5 in the Dial-Stop Screws section, substituting a smooth dial for the serrated dial in Step 5. W iring Figure 14: Removing the Setpoint Dial 4. On the front of the module cover, there is a series of seven holes on either side of the setpoint dial pivot, which had been hidden by the knob. To limit travel of the dial, choose the desired range, and insert screws in the corresponding holes. (See Table 1.) For example, for a limitation of ±4.2F, insert one screw each in the holes marked (A) in Figure 15. Note: For an asymmetrical range, insert screws into differently lettered holes on each side. Table 1: Dial Range Limits Holes 55-85 F ±5 F 12-28 C A 57.5/82.5 ±4.2 13.3/26.7 B 59.3/80.7 ±3.6 14.3/25.7 C 61.2/78.8 ±3 15.3/24.7 D 63/77 ±2.3 16.3/23.7 E 65/75 ±1.7 17.3/22.7 F 66.8/73.2 ±1 18.3/21.7 G 68.6/71.4 ±0.4 19.3/20.7! CAUTION: Equipment Damage Hazard. Disconnect the power supply before wiring connections are made to avoid electrical shock or possible equipment damage. Make wiring connections to the terminal blocks in the base of the TM-9100 module using 24-14 AWG wire. Follow the wiring diagrams shown in Figures 16 and 17. IMPORTANT: All wiring to the module is low voltage (Class 2) and must be separated from the power line voltage wiring. Do not run wiring close to transformers or high frequency generating equipment. Complete and verify all wiring connections before applying power to the controller. Figure 15: Dial-stop Screws 5. Press the dial back in place on the cover, making sure the pointer (indentation) is aligned with the 70 F (or 20 C) mark at the top of the circle. Then place the cover over the lower edge of the TM-9100 base and push the upper part of the cover until it clicks firmly into place. Figure 16: Wiring to a Room Command Module Using an Internal NTC (Negative Temperature Coefficient) Sensor 6 TM-9100 Series Room Command Module Product/Technical Bulletin

TC-9100 Series Controller 52 51 50 24 23 22 21 20 15 14 To Remote NTC Sensor TM-9150/TM-9160 Room Command Module Maximum 164 ft. (50 m) Fan Speed (Optional) Right 23 CW 22 21/24 20 15 14 Left CCW Setpoint (Optional) Common NTC Sensor LED Temporary Occupancy Button Figure 17: Wiring with Remote NTC Sensor Table 2: Nominal Temperature vs. Resistance for Thermistor Sensor Temperature Resistance (ohms) F C Thermistor 30-1 7784 40 4 5880 50 10 4484 60 16 3450 70 21 2678 80 27 2095 90 32 1652 100 38 1313 110 43 1051 Resistance (ohms) 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 30-1 40 4 50 60 70 80 90 10 16 21 27 32 Temperature, F ( C) 100 38 110 43 Replacement and Repair Field repairs must not be made. To order a replacement, refer to the Ordering Information section for the desired product code number, and contact your Johnson Controls representative. Ordering Information Table 3: Room Command Modules Ordering Code TM-9151-0000 Setpoint Scale None TM-9161-0000 12 to 28 C Fan Switch TM-9161-4005 +/-3 C None TM-9161-5000 55 to 85 F TM-9161-5005 +/-5 F TM-9161-0002 12 to 28 C TM-9161-4007 +/-3 C 3-speed TM-9161-5002 55 to 85 F Fan Override TM-9161-5007 Note: +/-5 F All TM-9100 series models include an NTC sensor, a Temporary Occupancy button, and a wallplate for wallbox mounting. Table 4: Replacement Parts and Accessories Ordering Code TE-6300-607 Description TE-6400-603 End Caps (2) TM-9100-8901 TM-9100-8902 T-4000-119 ACC-INSL-0 ACC-INSL-1 3 in. Thermistor Probe for remote NTC temperature sensing (Refer to the TE-6300 Series Temperature Sensors Product/Technical Bulletin [LIT-216320] for more information.) Dial-Stop Screws Kit (bag of 100 self-tapping screws) Serrated Knob Kit (bag of 10 knobs) Stat Adjustment Tool (to open module) Wallbox Mounting Pad (bag of 10) Surface Mounting Pad (bag of 10) Figure 18: Temperature vs. Resistance for Thermistor Sensor TM-9100 Series Room Command Module Product/Technical Bulletin 7

S pecifications Product Ambient Operating Conditions Ambient Storage Conditions Terminations TM-9100 Series Room Command Module 32 to 122 F (0 to 50 C); 10 to 90% RH non-condensing -4 to 158 F (-20 to 70 C); 100% RH non-condensing Terminal block accommodates 24 to 14 AWG (maximum) wire Thermistor Sensor Temperature Coefficient: Nonlinear, negative temperature coefficient Reference Resistance: 2.25k ohms at 77 F (25 C) Accuracy: ±0.36 F (±0.2 C) in the range of 32 to 158 F (0 to 70 C) Remote Setpoint Fan Speed Selector Temporary Occupancy Button Mode Indicator Mounting Housing Dimensions (H x W x D) Shipping Weight 10k ohm, 3-wire potentiometer marked for 55 to 85 F, 12 to 28 C, -5 to +5 F, or -3 to +3 C 10k ohm, 3-wire potentiometer: AUTO, OFF, LO, MED, HI Momentary contact Red LED Direct surface mount or wallbox mounting base Material: Flame-resistant thermoplastic, self-extinguishing UL94 VO 3.2 x 3.2 x 1.3 in. (80 x 80 x 33 mm) 0.33 lb (0.15 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Printed in U.S.A. www.johnsoncontrols.com 8 TM-9100 Series Room Command Module Product/Technical Bulletin