TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters:DC/AC+AC/DC+DC/DC+AC/AC)

Similar documents
Transparent and Functional Motors Application AEL-FTM

Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

Screenshot of the computer data acquisition and calculations software INTRODUCTION

DC Brushless Motor Application AEL-DCBRA

Integrated Laboratory for Electrical Machines LIMEL

Computer Controlled Heat Exchangers Training System, with SCADA and PID Control TICC

Motor-Generator and Transformer Construction Application AEL-MGTC

EDIBON SCADA System and PID Control included. 2 Control Interface Box. 1 TIUS. Base Service Unit. Cables and Accessories Manuals. TIPL.

Photovoltaic Solar Energy Modular Trainers

Photovoltaic Solar Energy Modular Trainers

Fluid Friction in Pipes, with Hydraulics Bench (FME00) AFT

Wind Energy Unit EEE. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

Final User Smart Grid Trainer AEL-FUSG

Photovoltaic Solar Energy Unit EESFB

MGI. Gyroscope PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Biodiesel Process Unit EBDB

Hydraulic and Electro-Hydraulic Application AE-HD

Basic Unit of Mechanical Drive Systems MDSU. Engineering and Technical Teaching Equipment INTRODUCTION GENERAL DESCRIPTION

Energy Power Plants Trainer AEL-EPP

ELECTRIC MACHINES EUROLAB 0.3 kw

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION

Pneumatic and Electro-Pneumatic Application AE-NS INTRODUCTION

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

RENEWABLE ENERGY TRAINER

BAIJI OIL TRAINING INSTITUTE ISO-9001:2008 DATE :1/4/2014 LABORATORY FOR THE ELECTRICAL SYSTEMS AND CONTROL OF OIL DRILLING RIGS $

ELECTRIC MACHINES UNILAB 1 kw

AEL-4. Advanced Electrical Laboratories (AEL-LABS): Electromechanical Constructions Lab. Engineering and Technical Teaching Equipment

Electrical Machines Lab

A New Buck-Boost Converter for a Hybrid-Electric Drive Stand P. Mašek

Assembly and Maintenance of Pumps AMP

ELECTRIC MACHINES EUROLAB 0.3 kw

electronic control of electrical machines

Electricity Course. Part B Course Outline

Electrical Power Systems 2014/15

A Electric Power / Controls ELECTRIC POWER TECHNOLOGY 0.2 kw

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

The Wound-Rotor Induction Motor Part I

Power Electronics Training System

Electric Power Technology Training Systems

Power Electronics Training System

ELECTRICAL ENGINEERING DEPARTMENT LIST OF EQUIPMENT IN EEM LAB

List of major equipment in Electrical Enginerring Department Labs

Powerframes - Power Electronics

ELECTRICAL MACHINES LAB.

9. Electrical Motors Operation and Protection Lab (150-A).

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Question Number: 1. (a)

Second Edition. Power Electronics. Devices and Circuits. V. Jagannathan

Electromechanical Training System

Practical Variable Speed Drives and Power Electronics

Wind Turbine Emulation Experiment

High-Voltage, High-Current DC- DC Converters Applications and Topologies

Motor Winding Kit. LabVolt Series. Datasheet

TECHNICAL DATA SHEET KVA UPS Systemss

Industrial Controls Training Systems

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Powerframes - Power Electronics

Electrical Power & Machines Range

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

AC/DC FFE converter power module

AEL-3. ELECTRICAL MACHINES LAB AEL-2. HOME AUTOMATION SYSTEMS LAB

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Load Test On 3 Phase Slip Ring Induction Motor Lab Manual

THYRO-A TM. Thyristor Power Controller (SCR) 8 A 1,500 A

2 kw Electromechanical Training Systems

Inverter with MPPT and Suppressed Leakage Current

Brake Test On Three Phase Induction Motor Lab Manual

Development of Electrical Power System Simulator.

Course Name: POWER ELECTRONICS Course Code: EE603 Credit: 4

Motor Drives Training System (Stand-Alone, 120 V Version) (8036-C0)

A Electric Power / Controls SMART GRID TECHNOLOGIES 0.2 kw

Introduction to El. Energy Systems. October 1, 2014

Principles of Doubly-Fed Induction Generators (DFIG)

ELECTRONIC EQUIPMENT DISTRIBUTION POWER ELECTRONIC COMPONENTS

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index

ELECTRIC MACHINES OPENLAB 0.2 kw

New & Renewable Energy

EMMS3 ELECTRICAL MACHINES MODULAR SYSTEM 300W

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

8036-A0 Motor Drives Training System (Stand-Alone)

THYRO-A DIGITAL THYRISTOR SCR POWER CONTROLLERS 8 TO 1500 A

Thyro-A DIGITAL ThyrIsTor scr power ConTroLLers 8 To 1500 A

Compression/Tension Testing Machines

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

Power Systems and Smart Grid Technology Lab

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Onfiniti. 1 Phase UPS

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Impulse Voltage Test System, Q Structure, kV

Exercise 7. Thyristor Three-Phase Rectifier/Inverter EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Thyristor three-phase rectifier/inverter

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives

Guaranteed Technical Particulars(GTP) Deviation/Remarks Specify if any. Computerized Motor testing system suitable to test LV 3 phase motors

Power Systems Trainer

Power electronic grid connection of PM synchronous generator for wind turbines

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Transcription:

Technical Teaching Equipment Computer Controlled Teaching Unit for the Study of Power Electronics (Converters:DC/ACAC/DCDC/DCAC/AC) TECNEL Always included in the supply: RTC. EDIBON Real Time Control System Teaching Technique used 1 Unit: TECNEL. Teaching Unit for the Study of Power Electronics, including Control Interface. (Converters: DC/AC AC/DCDC/DCAC/AC). 4 5 2 Data Acquisition Board Cables and Accessories Manuals PROCESS DIAGRAM AND ELEMENTS ALLOCATION 3 Software for: - Computer Control - Data Acquisition - Data Management Computer (not included in the supply) Products Products range Units 2.-Electronics DIODES Module THYRISTORS Module FRONT PANEL IGBTS Module CAPACITORS Module OPEN CONTROL MULTICONTROL REAL TIME CONTROL POWER Supply PRACTICES SCHEMES SENSORS Module BACK PANEL Worlddidac Member ISO:9001-2000 Certificate of Approval. Reg. No. E204034 European Union Certificate Page 1 Certificates ISO 14001: 2004 and ECO-Management and Audit Scheme (environmental management) Worlddidac Quality Charter Certificate Worlddidac Member

1 DESCRIPTION TECNEL is a Unit with Computer Control and Data Acquisition System designed to study the basis of Power Electronics. It allows students to study AC/DC, DC/AC, DC/DC, AC/AC converters. Basically, it consists of three modules of power electronics elements: diodes, thyristors and IGBTS. SPECIFICATIONS Items always included in the supply: TECNEL. Unit: Diagram in the front panel with similar distribution that the elements in the real unit. Steel box. Front panel: Diodes module: 6 diodes. Thyristors module: 6 thyristors. IGBTS Module: 6 IGBTS. Snubber net. Sensors module: 4 Voltage sensors. 2 Current sensors. Power supply connections for Vr, Vs, Vt, Neutral and Ground. Practices schemes. Back panel: Data Acquisition Board Connector (SCSI connector). Tachodynamo connector. Main fuses (Vr, Vs, Vt) and LEDs. Circuit breaker (main switch). Single-phase driver. Three-phase driver. IGBT driver. TSI board. PIC board. SKHI61 board. Four relays board. 2 Three-phase relays. Commuted power supply. Three-phase magnetothermal. Control Interface. TECNEL Unit DAB. Data Acquisition Board: PCI Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI. Analog input: Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KSPS (Kilo samples per second). Input range (V)= ± 10V. Data transfers=dma, interrupts, programmed I/0. Number of DMA channels=6. Analog output: Number of channels=2. Resolution=16 bits, 1 in 65536. Maximum output rate up to: 833 KS/s. Output range(v)= ± 10V. Data transfers=dma, interrupts, programmed I/0. Digital Input/Output: Number of channels=24 inputs/outputs. D0 or DI Sample Clock frequency: 0 to 1 MHz. Timing: Counter/timers=2. Resolution: Counter/timers: 32 bits. 2 5 TECNEL/CCSOF. Computer ControlData AcquisitionData Management Software: Compatible with all actual Windows operating systems. Graphic and intuitive simulation of the process in screen. Compatible with the industry standards. Registration and visualization of all process variables in an automatic and simultaneously way. Flexible open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters. Management, processing, comparison and storage of data. Sampling rate up to 250,000 data per second. Comparative analysis of the obtained data, after to the process and modification of the conditions during the process. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals: Required Services, Assembly and Installation, Interface and Control Software, Starting-up, Safety, Maintenance, Calibration & Practices Manuals. 3 4 DAB TECNEL/ CCSOF * References 1 to 5: TECNEL DAB TECNEL/CCSOF Cables and Accessories Manuals are included in the minimum supply, enabling a normal operation. Page 2

SPECIFICATIONS (continuation) Complementary items: Simulation Software: 6 PECADS. Power Electronics Computer Aided Design and Simulation Software.(Converters: DC/AC, AC/DC, DC/DC, AC/AC). (See PECADS Catalogue). PECADS Digital Measurement Unit: 7 EAL. Network Analyzer Unit: This unit shows the main electric parameters on the electric network through the interface and an easy parameter selection. Steel box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase (R,S,T) measure and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20-500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02-5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kw. Prec.: ± 1%. Power Factor: Power Factor for each phase and average. Range -0.1 to 0.1. Prec.: ± 1%. Temperature: Operating temperature 0 to 50 C. *It has to be complemented with a digital multimeter when working with DC. Required services: power supply: 220 V/50 Hz. - 110 V/60Hz. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. Approx. EAL Analog Measurement Unit: 8 EAM-VA. Analog Measurement Unit: This unit allows to analyze the different voltages and currents involved in a circuit through a simple frontal panel that includes analog measurement instruments. Steel box. 4 Voltmeters. - A.C. Measuring Instruments with moving iron. - Voltmeter with measuring range from 0 to 500Vac. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Ammeters. - A.C. Measuring Instruments with moving iron. - Ammeter with measuring range of 0 to 5A. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Analog inputs for each meter. Dimensions: 490 x 330 x 310 mm. approx. Weight: 10 Kg. approx. EAM-VA Page 3

RECOMMENDED ACCESSORIES Loads: IND. Inductance: (2 units) - From 33 to 236 mh, or similar. REV. Variable Resistance: (2 units) -0-150W (500W), or similar. OR IND REV RCL3R. Resistive, Inductive and Capacitive Loads Module: Our Resistive, Capacitive and Inductive Loads Module (RCL3R) offers: Single and Three-phase resistances. Single and Three-phase inductances. Single and Three-phase capacitors. Steel box. Diagram in the front panel. Variable resistive loads: 3 x [ 150 W (500 W) ]. Fixed resistive loads: 3 x [ 150 W (500 W) 150 W (500 W) ]. Inductive loads: 3 x [ 0, 33, 78, 140, 193, 236 mh ].(230V /2 A) Capacitive loads: 3 x [ 4 x 7 mf ]. (400V) Dimensions: 490 x 450 x 470 mm. approx. Weight: 30 Kg. approx. RCL3R Motors: EMT15. D.C. Permanent magnet motor: Power: 100W. Speed:4000 r.p.m. Maximum terminal voltage: 100V. This motor is supplied with connectors, couplings and standard motor support. EMT15 EMT17. Three-phase motor of squirel cage with Y connection: Power: 250 W. Speed: 2760 r.p.m. Frequency: 50 Hz. V. Armature: 3 x 380 Vac. I. Armature nominal: 2.3-1.3A. This motor is supplied with connectors, couplings and standard motor support. EMT17 Tachodynamo: TECNEL/T. Tachodynamo: The TECNEL/T is an automatic unit, that could be permanently connected to the main rotor. Output voltage gradient: 30 /- 3% V /1000 r.p.m. Electrical supply: continuous d.c. output 0-100 V. Dimensions: 200 x 150 x 50 mm. approx. Weight: 1 Kg. approx. TECNEL/T Page 4

RTC (EDIBON Real Time Control System) Software Main Screens Installation and Configuration Screens Main installation menu Data Acquisition Board Drivers Installation Control Software Installation Main screen Main Menu screen Practices Selection screen Page 5 Continue...

RTC (EDIBON Real Time Control System) Some typical exercises results Single-phase Rectifier Half Wave Non-controlled: Single-phase Rectifier Half Wave, Non-controlled, RL load: Page 6 Continue...

RTC (EDIBON Real Time Control System) Some typical exercises results Single-phase Rectifier Full Wave, Non-controlled, R load: Single-phase Rectifier Half Wave Controlled: Page 7 Continue...

RTC (EDIBON Real Time Control System) Some typical exercises results Three-phase Rectifier, Full Wave, Non-controlled: Single-phase PWM Control: Page 8 Continue...

RTC (EDIBON Real Time Control System) Some typical exercises results Single-phase Square Inverter: Page 9

Some Practical Possibilities of the Unit: EXERCISES AND PRACTICAL POSSIBILITIES 1.- Single phase half-wave rectifier with load R. 2.- Single phase half-wave rectifier with load R-L. 3.- Single-phase half-wave rectifier with R-L load with free wheeling diode (FWD). 4.- Single-phase full-wave rectifier. 5.- Three-phase half-wave uncontrolled rectifier. 6.- Three-phase full-wave uncontrolled rectifier. 7.- Single-phase half-wave controlled rectifier. 8.- Single-phase full-wave controlled rectifier. 9.- Single-phase full-wave controlled rectifier with a DC motor. 10.- Three-phase full-wave completely controlled. 11.- Single-phase semi-controlled rectifier. 12.- Three-phase full-wave semi-controlled rectifier. 13.- Chopper. 14.- Single-phase square-wave inverter. 15.- Single-phase displaced-phase inverter. 16.- Single-phase inverter. PWM control. 17.- Three-phase inverter. PWM control with R load and R-L load. 18.- Three-phase inverter. PWM control with AC motor. 19.- Alternating regulators: R and R-L load. 20.- Asynchronous three-motor with rotor in short circuit (squirrel cage). POSSIBILITIES OF OTHER AVAILABLE EXPANSIONS Expansion 1: Expansion 2: 9 Mini ESN. Multipost EDIBON Mini Scada-Net System Teaching Technique 10 used ESN. Multipost EDIBON Scada-Net System Teaching Technique used 1 UNIT = 30 STUDENTS can work simultaneously n Any other additional unit Teaching Unit for the Study of Power Electronics, including Control Interface. (Converters:DC/ACAC/DC DC/DCAC/AC) (TECNEL) Computer Control Software: Computer Control Data Acquisition Data Management BASIC ELECTRONICS AND ELECTRICITY INTEGRATED LABORATORY (LIEBA) (1) TEACHING UNIT FOR THE STUDY OF ANALOG/DIGITAL AND DIGITAL/ANALOG CONVERTERS (CADDA) (1) TEACHING UNIT FOR THE STUDY OF REGULATION AND CONTROL (RYC) CENTRAL PLC ELECTRICAL MACHINES UNIT (EME) PLC PLC PLC PLC PLC (1) TEACHING UNIT FOR THE STUDY OF POWER ELECTRONICS (TECNEL) (1) (1) n (1)Interface n PLC 30 Student Post Teacher s Central Computer LOCAL NET OPEN CONTROL MULTICONTROL MULTI STUDENT POST Mini Scada-Net Software Note: The Mini ESN system can be used with any computer controlled unit. OPEN CONTROL MULTICONTROL MULTI STUDENT POST REAL TIME MULTICONTROL SYSTEMS 30 Student Post SCADA CENTRAL COMPUTER LOCAL NET Option Note: The ESN system can use any computer controlled unit. ETDL EDIBON TECHNICAL DISTANCE LEARNING SYSTEM 30 students can work at the same time ORDER INFORMATION Items always included in the supply Complementary items to the standard supply Minimum configuration for normal operation includes: Simulation Software: Unit: TECNEL. Teaching Unit for the Study of Power Electronics, 1 6 2 3 4 5 including Control Interface. (Converters:DC/AC AC/DC DC/DC AC/AC). DAB.Data Acquisition Board. TECNEL/CCSOF. Computer Control Data Acquisition Data Management Software. Expansions: Cables and Accessories. Manuals. 7 8 9 10 PECADS. Power Electronics Computer Aided Design and Simulation Software. (Converters: DC/AC, AC/DC, DC/DC, AC/AC). Measurement Units: EAL. Network Analyzer Unit. EAM-VA. Analog Measurement Unit. Mini ESN. Multipost EDIBON Mini Scada-Net System. ESN. Multipost EDIBON Scada-Net System. * IMPORTANT: Under TECNEL we always supply all the elements for immediate running as 1, 2, 3, 4 and 5. Page 10

REQUIRED SERVICES - Electrical supply: Three-phase with neutral and ground, 380V/50Hz or 220V/60Hz. - Computer (PC). - Loads (see recomended accesories). DIMENSIONS & WEIGHTS - Dimensions: 490 x 330 x 310 mm. approx. - Weight: 40 Kg. approx. RECOMMENDED ACCESSORIES - IND. Inductance REV. Variable Resistance. (2 units of each one) OR - RCL3R. Resistive, Inductive and Capacitive Loads Module. Loads: - EMT15. DC Permanent magnets motor. - EMT17. Three-phase motor of squirrel cage with Y connection. Motors: - TECNEL/T. Tachodynamo. Tachodynamo: AVAILABLE VERSIONS Offered in this catalogue: - TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics (Converters: DC/AC AC/DC DC/DC AC/AC). Offered in other catalogue: - TECNEL/B. Computer Controlled Basic Teaching Unit for the Study of Power Electronics (Converters: AC/DC AC/AC). Specifications subject to change without previous notice, due to the convenience of improvements of the product. * REPRESENTATIVE: C/ Del Agua, 14. Polígono San José de Valderas. 28918 LEGANES. (Madrid). SPAIN. Phone: 34-91-6199363 FAX: 34-91-6198647 E-mail: edibon@edibon.com WEB site: Issue: ED02/08 Date: October/2008 Page 11