INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Similar documents
INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

BASYS Infrared Sensor Activated

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR DOUBLE AND TRIPLE STATION SENSOR ACTIVATED SOLID SURFACE LAVATORY SYSTEMS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

Optima ETF-600/ETF-610

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC INFRARED SENSOR ACTIVATED LAVATORY FAUCETS. Below Deck, Mechanical Below Deck, Thermostatic

Maintenance Guide. OPTIMA Components:

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

BASYS Infrared Sensor Activated

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS

Sloan Automatic Infrared Sensing Faucets

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEMS SENSOR ACTIVATED ROYAL CONCEALED and EXPOSED URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

Installation Instructions

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Installation Instructions

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap

Installation Instructions

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail

Electronic Hand Washing Faucet

Installation Instructions

G2 Optima Plus Flushometer

Installation Instructions

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Installation Instructions

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

INSTALLATION INSTRUCTIONS

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

EBF-550. Battery Powered Hand Washing Faucet

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

Camaya Series Soap Dispenser

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED SLOAN EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

LIGATURE RESISTANT SENSOR FAUCET

Installation Instructions

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

Aqua-FIT Serio Series TM

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

Allura. Widespread Lavatory Faucet SLW-4712 Installation and Service Instructions. Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712

Installation Instructions

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Single Lever Pull-Out Kitchen Faucet

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Aquila Single Lever Vessel Faucet

Britt Single Handle Commercial Kitchen Faucet

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Artec Pro Single Handle Commercial Kitchen Faucet

INSTALLATION GUIDE. Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05

Installation Instructions

Sheven Single Lever Vessel Faucet

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED CROWN & CROWN II FLUSHOMETER EXPOSED CLOSET & URINAL INSTALLATIONS

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

INSTALLATION INSTRUCTIONS

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions / Warranty. Citterio 39115XX1

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions Series

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Installation Instructions

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Transcription:

Code No. 0816496 Rev. 2 (02/09) INSTLLTION INSTRUCTIONS FOR SLON SF ELECTRONIC SENSOR CTIVTED LVTORY FUCETS SF SERIES FUCETS SF-2100 Series Transformer Powered with attery ackup, Sensor ctivated, Pedestal Style Lavatory Faucets SF-2150 Series attery Powered, Sensor ctivated, Pedestal Style Lavatory Faucets SF-2200 Series Transformer Powered with attery ackup Sensor ctivated, Gooseneck Style Lavatory Faucets SF-2250 Series attery Powered, Sensor ctivated Gooseneck Style Lavatory Faucets SF-200 Series Transformer Powered with attery ackup Sensor ctivated, 4 Centerset Lavatory Faucets SF-250 Series attery Powered, Sensor ctivated 4 Centerset Lavatory Faucets PRIOR TO INSTLLTION Prior to installing the Sloan SF Series Electronic Lavatory Faucet, install the items listed below. lso, refer to the appropriate rough-in diagram. Plug-In Transformer Models SF-2100/SF-2200/SF-200/SF-2400 only Install electrical receptacle(s) for plug-in transformer(s) 120 VC, 1 amp service for each 6 VDC plug-in transformer used. International models may be supplied with a 220 VC/VDC transformer. Hot and cold water supply lines or tempered water supply line Drain lines International models are supplied with 1/2 G water connections. Important: INSTLL LL ELECTRICL WIRING IN CCORDNCE WITH NTIONL/LOCL CODES ND REGULTIONS. INSTLL LL PLUMING IN CCORDNCE WITH PPLICLE CODES ND REGULTIONS. 6 VDC STEP-DOWN TRNSFORMER MUST E USED FOR HRDWIRE PPLICTIONS. EFORE CONNECTING COPPER TUE(S) OR FLEX HOSE(S) TO SUPPLY STOP(S), FLUSH LL WTER LINES UNTIL WTER IS CLER. TOOLS REQUIRED FOR INSTLLTION Electric drill for drilling anchor holes (1/4 /6 mm drill bit) Straight blade and phillips blade screwdrivers Open end wrenches (9, 11, 1, 16, 22 mm) The components supplied with International Models of the SF Series Faucets may vary from what is shown in this manual. Consult factory to identify variations that may apply to your market. SF-2400 Series Transformer Powered with attery ackup, Sensor ctivated, Pedestal Style Lavatory Faucets SF-2450 Series attery Powered, Sensor ctivated, Pedestal Style Lavatory Faucets LIMITED WRRNTY Sloan Valve Company warrants its SF Series Electronic Hand Washing Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of one year from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries. THERE RE NO WRRNTIES WHICH EXTEND EYOND THE DESCRIPTION ON THE FCE HEREOF. IN NO EVENT IS SLON VLVE COMPNY RESPONSILE FOR NY CONSEQUENTIL DMGES OF NY MESURE WHTSOEVER.

FUCET ROUGH-IN SF-2100 / SF-2150 Series SF-2200 / SF-2250 Series SPOUT 2-1/8 (54 mm) SPOUT TRIM PLTE 1-1/4 (2 mm) MIN. DI. HOLE REQUIRED TRIM PLTE - Supplied with SF-2200/SF-2250 Optional item for SF-2200-INTL/SF-2250-INTL 2-1/8 (54 mm) 1-1/4 (2 mm) MIN. DI. HOLE REQUIRED GSKET RETINER NUT (2) 1-1/2 (8 mm) MX. DECK THICKNESS 24 (610 mm) LONG FLEX HOSE CONTROL MODULE 1/2 NPSM TO /8 COMPRESSION CONNECTION - Not Required for INTL Models GSKET RETINER NUT SF-200 / SF-250 Series 1-1/2 (8 mm) MX. DECK THICKNESS COPPER TUE OR FLEX HOSE 6-9/2 (160 mm) 6 (914 mm) LONG SENSOR CLE TEMPERED SUPPLY SPOUT 1 (25 mm) MIN. DI. HOLE REQUIRED HOT ND COLD WTER SUPPLY PPLICTIONS SLOTTED MOUNTING WSHERS (2) WING NUTS (2) 1-1/2 (8 mm) MX. DECK THICKNESS SF-2400 / SF-2450 Series DM VRITION (ELOW DECK MECHNICL) MIXING VLVE 2-1/8 (54 mm) SPOUT HOT SUPPLY /8 (10 mm) K-CHEK TEE COLD SUPPLY TRIM PLTE - Supplied with SF-2400/SF-2450 Optional item for SF-2400-INTL/SF-2450-INTL 1-1/4 (2 mm) MIN. DI. HOLE REQUIRED SIDE VIEW COPPER TUES OR FLEX HOSES - Flex Hoses Supplied Only with some International Models. GSKET RETINER NUT (2) 1-1/2 (8 mm) MX. DECK THICKNESS -7/8 (98 mm) 40 4-1/2 (114 mm) 10 (254 mm) 5-1/4 (1 mm) 27 4-45/64 (117 mm) 4-9/64 (119 mm) 20 4-1/2 (115 mm) 20 7 (180 mm) 2

1 2100/2150 SERIES & 2400/2450 SERIES Install Flex Hose and Mounting Studs 2200/2250 SERIES & 200/250 SERIES Install Flex Hose Install Mounting Studs. Install Flex Hose. Install Flex Hose. 2 2100/2150 SERIES, 2200/2250 SERIES & 2400/2450 SERIES Install Spout, Trim Plate and Spacer 200/250 SERIES Install Spout Pedestal Spout Pedestal Spout Pedestal Spout Trim Plate Spacer pply a bead of plumbers putty around the outside of the Faucet underbody. Trim Plate Trim Plate Spacer Spacer

2100/2150 SERIES ONLY Install Rubber Gasket, and Nuts 2200/2250 SERIES ONLY Install Rubber Gasket, and Nut Secure Faucet to the Deck by installing Rubber Gasket, and Nuts. Tighten Nuts securely. Do not overtighten. Rubber Gasket Nuts Secure Faucet to the Deck by installing Rubber Gasket, and Nut. Tighten Nut securely. Do not overtighten. Rubber Gasket Nut 200/250 SERIES ONLY Install Slotted Mounting Washers and Wing Nuts 2400/2450 SERIES ONLY Install Rubber Gasket, and Nuts SLOTTED MOUNTING WSHER Rubber Gasket WING NUT Nuts Secure Faucet to the Deck by installing Slotted Mounting Washers and Wing Nuts. Tighten Wing Nuts securely. Do not overtighten. Secure Faucet to the Deck by installing Rubber Gasket, and Nuts. Tighten Nuts securely. Do not overtighten. 4

4 Install Control Module in an appropriate location (see Rough-in) 5 Connect Sensor Cable and Water Lines to Control Module Using Control Module as a template, mark mounting holes on wall. When installed, Sensor Cable and Flex Hose need some slack. Note: dapter For /8 Connections only. Drill 1/4 (6 mm) hole at each mounting hole location. C Install Plastic nchors (supplied) into mounting holes in wall. Control Module Connect Sensor Cable (from Faucet). Connect Flex Hose (from Faucet). C Connect Water Line (supplied with INTL Models only) to Supply Stop and Control Module. Note: dapter For /8 Connections only. D Install Control Module to wall using Fasteners supplied. 6 Install atteries Loosen Cover Screws and remove Cover from Control Module. 7 Connect Transformer (Transformer Powered Models only) and Turn on Water Supply Plug Transformer into Receptacle. Remove attery Compartment, remove compartment lid using screwdriver and install four (4) -size batteries (supplied) as indicated by the (+) and ( ) symbols inside the attery Compartment. Replace compartment lid and tighten with screwdriver. Plug Transformer Jack into Control Module. C Turn on Water Supply. C Reinstall attery Compartment into the Control Module. D Reinstall Control Module Cover using all four (4) Screws. 5

7 Gang Transformer Installation To connect multiple faucets to a single transformer, use the Sloan SFP-5- Gang Transformer Kit (Purchase Separately). The SFP-5- Gang Transformer Kit is supplied with cables to connect up to 6 faucets. To connect up to 8 faucets, purchase 2 additional SFP-8 Cable Splitters separately. Connect the Transformers and Cables to the Sensor Faucets as shown below. 8 Set Range djustment NOTE: Sensor Range can be adjusted after power is supplied to the Faucet (battery or hardwire). Hold the red button in until the sensor flashes (approximately - 6 seconds). For complete installation, refer to instructions packaged with Gang Transformer Kit. SFP-5- Gang Transformer Kit is available in 120 VC only!!!!importnt!!!! DO NOT PLUG IN THE TRNSFORMER UNTIL LL CONNECTIONS RE MDE Plug-in Gang Transformer SFP-6 Cable Splitter SFP-8 To dditional Faucets (6 Max.) Cable Splitter SFP-8 Cable Splitter SFP-8 8 Set Range djustment (continued) 9 Set Water Flow Time-Out Place your hand (or card) in front of the sensor at the distance you desire the Faucet to activate. Leave hand or card at this location while the sensor range is setting. Remove hand or card when the sensor light turns off. The sensor range is now set. Note: The sensor range is dependent on the distance of your hand or card while the sensor is in range setting mode. Note: If no target is placed in front of the sensor, the sensor range will set to its longest distance. NOTE: There are two available time-out settings; 7 seconds and 70 seconds. Hold the red button in for more than six seconds. The water flow time-out setting will change from 7 seconds to 70 seconds or from 70 seconds to 7 seconds. 6

8 Test Faucet Operation Care and Cleaning of Chrome and Special Finishes 1. Place hands under faucet. Solenoid valve should click, LED in sensor window should blink once and water should flow from the spout. DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean Faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the Faucet from any splattering of cleaner. cids and cleaning fluids will discolor or remove chrome plating. 2. When hands are removed, the water flow should stop. TROULESHOOTING GUIDE 1. Faucet delivers water in an uncontrolled manner.. Faucet is defective. Contact Sloan Valve Company Installation Engineering Department (see below). 2. Faucet does not deliver any water when Sensor is activated. INDICTOR: Solenoid valve produces an audible CLICK.. Water supply stop(s) closed. Open water supply stop(s).. Water strainer in control module is clogged. Close supply stops and remove water inlet line at control module. Remove, clean and reinstall strainer and water inlet line. Replace strainer if required. INDICTOR: Solenoid valve DOES NOT produce an audible CLICK.. atteries low (battery powered models). Replace batteries.. Power failure (transformer powered models). Check power supply.. Faucet delivers only a slow flow or dribble when Sensor is activated.. Water supply stop(s) are partially closed. Completely open water supply stop(s).. Water strainer in control module is clogged. Close supply stops and remove water inlet line at control module. Remove, clean and reinstall strainer and water inlet line. Replace strainer if required. C.erator is clogged. Remove, clean, and reinstall aerator. Replace aerator if required. D.Valve is defective. Contact Sloan Valve Company Installation Engineering Department (see below). 4. Faucet does not stop delivering water or continues to drip after user is no longer detected.. Valve is defective. Contact Sloan Valve Company Installation Engineering Department (see below). 5. The water temperature is too hot or too cold on a Faucet connected to hot and cold supply lines.. Supply Stops are not adjusted properly. djust Supply Stops. When assistance is required, please contact Sloan Valve Company Installation Engineering Department at: 1-888-SLON-14: (1-888-756-2614) OR 1-847-2-2016 7

PRTS LIST 1 1 1C 1D 12 11 5 1 2D 2H 10 2 2 2E 4 2C 5 7 8 10 2F 6 9 10C 10 Item Part Description No. No. 1 Pedestal Faucet ssembly w/outlet (Models SF-2100/SF-2150) 1 Gooseneck Faucet ssembly w/outlet (Models SF-2200/SF- 2250) 1C Faucet ssembly w/outlet (Models SF-200/SF-250/) 1D Pedestal Faucet ssembly w/outlet (Models SF-2400/SF-2450/ 2 SFP-4 Mounting Hardware Kit, (Models SF-2100/SF-2150/SF-2400/ SF-2450) includes Items: 2, 2, 2D, 2E and 2F SFP-5 Mounting Hardware Kit, (Models SF-2200/SF-2250) includes Items: 2F, 2G and 2H SFP-16 Mounting Hardware Kit, (Models SF-200/SF-250) includes Items: 2C and 2F 2 eveled Gasket 2 Metal 2C ETF-546- Gasket, Washers (2), Wing Nuts (2) & Compression Fitting 2D Threaded Studs (2) 2E Nuts (2) 2F Screws and nchors for Control Module 2G Metal Washer 2H Gasket SFP-6 Plug-in Transformer (120 VC/6 VDC) SFP-20 Plug-in Transformer Type G Rectangular (UK) (240 VC/6 VDC) SFP-25 Plug-in Transformer Type C Round Pin (Euro) (240 VC/6 VDC) SFP-26 Plug-in Transformer Type Flat lade (sia) (240 VC/6 VDC) 4 atteries- size (4) 5 SFP-40-6-Pin Control Module w/ range adjustment button 6 Inlet adapter - 1/2" NPSM to /8" Compression Connection (not supplied with most international models) 7 SFP-10 Flex Hose, Control Module to Spout 8 SFP-11 Trim Plate w/ Spacer (not supplied with most international models) 9 ETF-617- /8 ak-chek Tee Compression Fitting Item No. Part No. Description ccessories 10 SFP-5- Gang Transformer Kit, includes: 10 SFP-6- Plug-in Transformer(120 VC/6VDC) 10 SFP-8 Cable Splitter, 51 /100 mm (5 included in kit) 10C SFP-7 Cable Extension, 51 /100 mm Repair Parts 11 SFP-41 Sensor (adjustable range - identified by a 6 pin connector) 12 SFP-15 Strainer(located in water inlet of control module) 1 Solenoid ssembly for SF control module IMPORTNT: Sloan added the range adjustment feature in ugust 2008 for faucets made prior to ugust 2008 use the following replacement items: 11 SFP-4 Sensor (identified by a 4 pin connector) 5 SFP-8 4-pin Control Module Replacement erators & Spray Heads (not shown) Models: SF-2100/2150, SF-200/250 & SF-2400/2450 SFP-1 0.5 gpm/1.9 Lpm Spray head SFP-2 2.2 gpm/8. Lpm erator SFP-15 0.5 gpm/1.9 vandal resistant spray head SFP- 24 2.2 gpm/8. Lpm vandal resistant aerator Models: SF-2200/2250 SFP-12 Gooseneck Spout w/ outlet SFP-14 1.5 gpm/5.7 Lpm Laminar Spray Head Items without part numbers are not sold separately The information contained in this document is subject to change without notice. SLON VLVE COMPNY 10500 Seymour venue Franklin Park, IL 6011 Phone: 1-800-982-589 or 1-847-671-400 Fax: 1-800-447-829 or 1-847-671-480 www.sloanvalve.com Copyright 2009 SLON VLVE COMPNY Printed 02-09