EDS / EFS Series Control Stations

Similar documents
EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Hazardous Factory Sealed Control Devices

Control Stations Hazardous and Non-Hazardous

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Motor Starters Hazardous and Non-Hazardous

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Circuit Breakers Hazardous

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Spring-loaded cover seats against neoprene gasket.

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Push Button. Rocker Arm

Enclosures. Section E

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Covers for Cast Iron or Aluminum Device Boxes

EBMC Combination Line Starters and Enclosures

FACTORY SEALED CONTROLS - INTRODUCTION

GHG43 Series Control Stations

Division 2 Contender Series Factory Sealed Control Stations

Condulet Conduit Bodies and Outlet Boxes Hazardous

FACTORY SEALED CONTROLS - INTRODUCTION

Junction Boxes Hazardous and Non-Hazardous

Industrial Control & Circuit Breakers

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

STAINLESS STEEL PANEL MOUNT

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Plugs and Receptacles: Hazardous Location

Condulet Cast Device Boxes and Covers Application and Selection

N2MV Series W Non-metallic

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

W-Series Junction Boxes

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

IEC 309 Plugs, Connectors, Receptacles, and Inlets

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

PEERLESS BLOWERS DIRECT DRIVE BLOWERS

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Standard Materials Bodies and covers: copper-free aluminum.

Hazardous Duty Applications

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

ACE Variable Frequency Drive System

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

NMC Combination Line Starters and Enclosures

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

ACE20 explosionproof variable frequency drives Utilizes Allen-Bradley PowerFlex 700 drives

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

UniCode Series Factory Sealed Control Stations and Pilot Lights

SECTION ENCLOSED CONTROLLERS

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Solar Combiner Solutions

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

SynergEX Panelboards for Hazardous Locations

One piece neoprene protective sleeve seals wiring area from dirt, grit and moisture.

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

KNOCKOUTS Cat. # Bracket Plastic Clamp Conduit Cable Unit Qty. Wt. Lbs. Per 100 TP100 TP104 TP106 TP114

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

254 Series Convector. Standard Construction Features

Transcription:

EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: To prevent arcing of enclosed device from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust In non-hazardous areas where sturdy, durable enclosures are required In conjunction with magnetic starters or contactors for remote control of motors Manual motor starting switch enclosures are used: For manual starting of small AC or DC motors To provide manual starting and stopping and, in the case of units with heaters, motor running protection Features: Factory sealed devices have many distinct advantages: Reduce installation problems Eliminate external seals Lower installation costs Improve safety Are used with general purpose snap and pushbutton type switches Standard neoprene covers for front operated pushbuttons. Prevents accumulation of dirt and entrance of water around operating shafts Mounting lugs and taper tapped hubs with integral bushings Large machine screws for fastening covers to bodies Lockout provisions on front operated pushbutton (marked "STOP" and "OFF") and selector switch covers Lockout hole for padlock having " hasp is provided when used with covers for front lever and side rocker type operation Close tolerances in machining of wide, mating flanges and journalled shafts and bearings for front button operation, produces flametightness of enclosure joints On enclosures with front lever and side rocker type operating handles, threaded type shafts and bushings are used to ensure flametightness Dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs /2" to " sizes When STOP is indicated, button is automatically red. When START is indicated, button is automatically green. Otherwise, black buttons are standard. Certifications and Compliances: NEC/CEC: Class I, Division & 2, Groups B*, C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III NEMA/EEMAC:, 7B*CD, 9EFG UL Standard: 20 CSA Standard: C22.2 No. 0 Standard Materials: Bodies Feraloy iron alloy; copper-free aluminum Front operated pushbutton and pilot light covers Feraloy iron alloy Side operated type pushbutton covers copper-free aluminum Shafts stainless steel Shaft bushings stainless steel Rocker handle and pushbutton guards type 6 / 6 nylon Sealing enclosures copper-free aluminum Standard Finishes: Feraloy iron alloy electrogalvanized and aluminum acrylic paint Copper-free aluminum natural Type 6 / 6 nylon black Stainless steel natural Options: The following special options are available from the factory by adding suffix to Cat. #: Description Suffix Momentary red emergency STOP button front operated mushroom button, breaks normally closed contacts only... S Lockout provision on front operated pushbutton cover (standard on buttons marked "OFF" and "STOP")... S5 For 24 VDC operation on pilot lights... S00 Three-position selector switches with modified operation: Momentary contact clockwise operation, spring return to center, maintained contact counter-clockwise operation S64 Momentary contact counter-clockwise operation, spring return to center, maintained contact clockwise operation... S65 Bodies and covers (single and two gang units) copper-free aluminum... SA Where indicated in the catalog listings, EDS units suitable for Class I, Division, Group B usage can be supplied, add suffix -GB, EFS units are suitable for Class I, Division, Group B as standard... GB Maintained red emergency STOP button with lockout front operated mushroom button breaks normally closed and makes normally open contacts (push to stop), lockout standard (will not fit with a pilot light if transformer is required)... S769 Spring return to center from right and left... S842 EDS bodies and factory sealed cover and device sub-assemblies are available for field assembly (see page 52). *See suffix GB in Options section. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 206 Eaton

EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Methods of Factory Sealing EFS/EDS Series EDS Series Factory sealed EDS and EFS pilot light, pushbutton and selector switch control stations do not need external sealing. Device contacts are factory sealed in explosionproof ESWP contact blocks. Small, compact enclosures have accurately ground wide flanges on both the body and cover for a flame-tight joint. Dimensions (Inches) Bodies EDS factory sealed snap switches or manual motor starting switches do not need external sealing. The switches are enclosed in a unique sealing well with double flanges which mate with the cover and the body. Small, compact enclosures have accurately ground wide flanges on body, cover and sealing well for flame-tight joints. Wiring pigtails are factory sealed from under the sealing well. Reliable pouring of seals at the factory ensures safe sealing. Covers Hub Size /2 Dim. "h" Dim. "i" 7 /8 5 Side View General use snap switch front operated and manual motor starting switch Pushbutton switch rocker type side operated Front View - Single gang Front View - Two gang Pushbutton switch front operated Selector switch *See suffix GB in Options section. Dimensions are approximate, not for construction purposes. Surface covers have same length and width as bodies. 526 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business

EDS / EFS Series Fully Assembled EFS Pilot Lights Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: EFS pilot lights are used: In areas which are hazardous due to the presence of flammable vapors, gases or highly combustible dusts For installation at petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards exist To visually indicate at a remote location that the desired function is being performed Features: Small, compact enclosures with accurately ground flange on both body and cover for flame-tight joint Pilot lights are factory sealed. Conventional external seals are not required Dead end (EFS) or through feed (EFSC) hubs /2" to " sizes Certifications and Compliances: NEC/CEC: Class I, Groups B*, C, D Class II, Groups E, F, G Class III NEMA/EEMAC:, 7B*CD, 9EFG UL Standard: 20 CSA Standard: C22.2 Options: The following special options are available from factory by adding suffix to Cat. #: Description Suffix Pilot lights for circuit voltages up to 600 volts maximum (standard voltage range 0 25) See Listings LED pilot lights in place of standard incandescent pilot lamps Bodies and covers copper-free aluminum LED 24 VDC operation on pilot lights S00 SA Standard Materials: Bodies Feraloy iron alloy (U.S.) and copper-free aluminum (Canada) Pilot light covers Feraloy iron alloy Operating shafts stainless steel Standard Finishes: Feraloy iron alloy electrogalvanized with aluminum acrylic paint Copper-free aluminum natural Stainless steel natural Electrical Rating Range: Pilot lights 0 to 600VAC * External conduit seal required for inch hub size in Division, Group B within 5 feet (.5 meters) of enclosure. 50 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business

EDS / EFS Series Fully Assembled EFS Pilot Lights Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Pilot lights listed below are factory sealed and do not require external seals*. Lamps are 6 watt, miniature bayonets, incandescent lamps for use on 0 25 volt circuits. LED pilot lights can be provided in place of standard incandescent lamps by adding suffix LED after the color symbols. For Options see pages 50 5. Enclosures with single pilot covers only can be equipped with a transformer for each lamp for high voltages as shown. Ordering Information Enclosure with Single Pilot Light Hub Size Dead End Cat. # Through Feed Cat. # /2 EFS524 ➀ EFSC524 ➀ EFS2524 ➀ EFSC2524 ➀ EFS524 ➀ EFSC524 ➀ Enclosure with Double Pilot Lights Hub Size Dead End Cat. # Through Feed Cat. # /2 EFS56 ➀ EFSC56 ➀ EFS256 ➀ EFSC256 ➀ EFS56 ➀ EFSC56 ➀ Transformer Voltages Above 25 Nominal Volts 50 60 Hertz Transformer Primary Voltage Range 220 / 0 220 240 T2 440 / 0 440 480 T4 550 / 0 550 600 T5 Cat. # Suffix ➀ Add color symbol for each pilot light from table below. Example: EFS56 with red and green lights is EFS56-J-J Color Symbol Color Symbol Color Symbol Red J Amber J6 Blue J Green J Clear J0 Dimensions In Inches: Typical body side view Front view Cover Dimensions are approximate, not for construction purposes. Hub Size Dim. "h" Dim. "i" /2 7 /8 5 * External conduit seal required for inch hub size in Division, Group B within 5 feet (.5 meters) of enclosure. LED pilot lights can be furnished in place of standard incandescent pilot lamps. Add suffix LED to catalog number after color symbol. Surface covers have same length and width dimensions as bodies. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business 5

EDS / EFS Series Sub-assembly Reference Guide For a complete list of components for EDS & EFS, see page 54 for FlexStation Series and their Sub-assemblies Complete Control Sub-assembly Station Cover & Device Cast Back Box Notes and Requirements PUSHBUTTONS EDS284 DSD98 EDS27 EDSC284 DSD98 EDSC27 EDS25 DSD922 EDS27 Start/ Stop Legend included EDSC25 DSD922 EDSC27 Start/ Stop Legend included EDS290 DSD92 EDS27 EDSC290 DSD92 EDSC27 EDS284-S769-EM-SP DSD98-S769-EM-SP EDS27 Emergency Stop Legend included EDSC284-S769-EM-SP DSD98-S769-EM-SP EDSC27 Emergency Stop Legend included EDS2284 (2) DSD98 EDS272 EDSC2284 (2) DSD98 EDSC272 EDS225 (2) DSD922 EDS272 Start/ Stop Legend included EDSC225 (2) DSD922 EDSC272 Start/ Stop Legend included EDS2290 (2) DSD92 EDS272 EDSC2290 (2) DSD92 EDSC272 PILOT LIGHTS EFS2524-J* DSD948-J* EDS27 EFSC2524-J* DSD948-J* EDSC27 EFS256-J*-J* DSD947-J*-J* EDS27 EFSC256-J*-J* DSD947-J*-J* EDSC27 PUSHBUTTON / PILOT LIGHT COMBINATIONS EDS247-J* DSD958-J* EDS27 * Insert pilot light color EDSC247-J* DSD958-J* EDSC27 * Insert pilot light color EDS2247-J* DSD948-J* & DSD92 EDS272 * Insert pilot light color EDSC2247-J* DSD948-J* & DSD92 EDSC272 * Insert pilot light color EDS22868-J*-J* DSD947-J*-J* & DSD92 EDS272 * Insert pilot light color EDSC22868-J*-J* DSD947-J*-J* & DSD92 EDSC272 * Insert pilot light color SELECTOR SWITCHES EDS227 DSD92 EDS27 EDSC227 DSD92 EDSC27 EDS2272 DSD924 EDS27 EDSC2272 DSD924 EDSC27 EDS227 DSD925 EDS27 EDSC227 DSD925 EDSC27 EDS2274 DSD926 EDS27 EDSC2274 DSD926 EDSC27 EDS2275 DSD927 EDS27 EDSC2275 DSD927 EDSC27 * Insert pilot light color When using the EFS Series pilot light in Cl. I, Div., Group B applications, the EFS back box is required in place of the EDS. MANUAL MOTOR STARTER WITH O/L EDS20 DS45A & SW EDS27 "-W * " for heater, or "-0" distributor provided EDSC20 DS45A & SW EDSC27 "-W * " for heater, or "-0" distributor provided EDS202 DS45A & SW4 EDS27 "-W * " for heater, or "-0" distributor provided EDSC202 DS45A & SW4 EDSC27 "-W * " for heater, or "-0" distributor provided EDS209 DS45A & SW EDS27 "-G * " for heater, or "-0" distributor provided EDSC209 DS45A & SW EDSC27 "-G * " for heater, or "-0" distributor provided EDS2094 DS45A & SW2 EDS27 "-G * " for heater, or "-0" distributor provided EDSC2094 DS45A & SW2 EDSC27 "-G * " for heater, or "-0" distributor provided EDS299 DS45A & SW9 EDS27 "-P * " for heater, or "-0" distributor provided EDSC299 DS45A & SW9 EDSC27 "-P * " for heater, or "-0" distributor provided EDS200 DS45A & SW0 EDS27 "-P * " for heater, or "-0" distributor provided EDSC200 DS45A & SW0 EDSC27 "-P * " for heater, or "-0" distributor provided www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business 59

EDS / EFS Series Sub-assembly Reference Guide For a complete list of components for EDS & EFS, see page 54 for FlexStation Series and their Sub-assemblies Sub-assembly Complete Control Station Cover & Device Cast Back Box Notes and Requirements MANUAL MOTOR STARTER EFD28-T8 DSD96 EDS27 Alternative DS45A & SQ D 250 KO- EDS27 SQ D switch provided by distributor EFDC28-T8 DSD96 EDSC27 Alternative DS45A & SQ D 250 KO- EDSC27 SQ D switch provided by distributor EFD249 DSD97 EDS27 Alternative DS45A & GE 268S EDS27 GE switch provided by distributor EFDC249 DSD97 EDSC27 Alternative DS45A & GE 268S EDSC27 GE switch provided by distributor SNAP SWITCHES EDS229 DS652 & SW5 EDS27 Alternative DSD9 EDS27 External Sealing Fitting Required EDSC229 DS652 & SW5 EDSC27 Alternative DSD9 EDSC27 External Sealing Fitting Required EDS28 DS652 & SW6 EDS27 Alternative DSD64 EDS27 External Sealing Fitting Required EDSC28 DS652 & SW6 EDSC27 Alternative DSD64 EDSC27 External Sealing Fitting Required EDS20 DS652 & SW7 EDS27 Alternative DSD96 EDS27 External Sealing Fitting Required EDSC20 DS652 & SW7 EDSC27 Alternative DSD96 EDSC27 External Sealing Fitting Required EDS240 DS652 & SW8 EDS27 Alternative DSD97 EDS27 External Sealing Fitting Required EDSC240 DS652 & SW8 EDSC27 Alternative DSD97 EDSC27 External Sealing Fitting Required EDS2229 (2) DS652 & (2) SW5 EDS272 Alternative (2) DSD9 EDS272 External Sealing Fitting Required EDSC2229 (2) DS652 & (2) SW5 EDSC272 Alternative (2) DSD9 EDSC272 External Sealing Fitting Required EDSC228 (2) DS652 & (2) SW6 EDSC272 Alternative (2) DSD64 EDSC272 External Sealing Fitting Required EDS220 (2) DS652 & (2) SW7 EDS272 Alternative (2) DSD96 EDS272 External Sealing Fitting Required EDSC220 (2) DS652 & (2) SW7 EDSC272 Alternative (2) DSD96 EDSC272 External Sealing Fitting Required EDSC2240 (2) DS652 & (2) SW8 EDSC272 Alternative (2) DSD97 EDSC272 External Sealing Fitting Required ROCKER SWITCHES EDS2596 DSD949 EDS27 EDSC2596 DSD949 EDSC27 EDS262 DSD95 EDS27 Start/ Stop Legend included EDSC262 DSD95 EDSC27 Start/ Stop Legend included EDS294 DSD950 EDS27 EDSC294 DSD950 EDSC27 EDS2696 (2) DSD949 EDS272 Start/ Stop Legend included EDSC2696 (2) DSD949 EDSC272 Start/ Stop Legend included EDS2262 (2) DSD95 EDS272 EDSC2262 (2) DSD95 EDSC272 EDS2294 (2) DSD950 EDS272 EDSC2294 (2) DSD950 EDSC272 Additional notes: See Eaton's Crouse-Hinds' installation instructions for any possible additional sealing requirements. Part numbers listed with " hub in back box (Ex. EDS284). For /2" hub, change the "2" to "" (EDS84). For " hub, change the "2" to "" (EDS84). with "Stop" legend have lockout provided as standard. Pilot Light Colors J*-- J= Red, J= Green, J6= Amber, J0= Clear, J= Blue. LED pilot lights are available with LED suffix. Pilot Light Transformers for voltages over 25V. Suffix T2= 240/220-0V, T4= 48040-0V, T5= 600/500-0V (not available on double pilot cover). Standard legend plate markings are available by adding nomenclature after the part number (EDS284-Run). Selector switch nameplate kits available. 2-Pos = "SS2KIT", -Pos = "SSKIT". See Replacement Parts book for additional information. Copper-free aluminum bodies and covers available with SA suffix. Additional control station options may be found in Section. Group B ratings may be achieved by adding the GB suffix or using the EFS back box. See part number instructions for the item required. Group B ratings may already be achieved when used in Class I, Division 2 applications. See Certifications and Compliances for item required. Additional control station configurations available through the FlexStation Component Series. 540 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business