ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Similar documents
2-position electric actuators with Ball valves VBZ ½...11/4

Electromotoric Actuators

S1024-2POS / S POS S2024-2POS / S POS

introduction FE Series Automated Butterfly Valves Product Data Sheet < STANDARDS >

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Electromotoric actuators

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Minimum 18 in-lb Torque

Safety switches for hinged doors

Electromotoric Actuators

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

EL5600 Series Electric Actuators for DN15 to DN100 Valves

NV Direct Coupled Globe Valve Actuator

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Safety rope switch with reset for emergency stop

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Electromotoric Actuators

Model 20 DPS.2005 Doc: J2-20DPS2005/01 Nov 2006

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Actuators for air dampers and control valves of oil burners

MF /MS Series

Safety rope switches with reset for emergency stop

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe

Powers TM Controls EA 338 Electronic Actuator

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Safety switches for hinged doors

Actuators for air dampers and control valves of oil burners

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

SAV Electronic Valve Actuator

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

FL series position switches

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Type 231 ACTUATOR FOR DAMPERS. G R U N E R t h e. f r i e n d l y a l t e r n a t i v e. Actuator with rotation drive. 20 Nm 30 Nm

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Electromotoric Actuators

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Position switches FD series

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Motorized Butterfly Valve

Electromotoric Actuators

Safety switches for hinges

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Actuators for air dampers and control valves of oil burners

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Motorized Butterfly Valve

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

introduction VKD Series Automated Ball Valves Product Data Sheet < STANDARDS >

Actuators for Air and Gas Dampers

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND TWO-POSITION CONTROL

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

MF4E MF4E

Recommendations Multipin connector Wired mode (permanent and pulse signal) Positioning mode

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

RUC industrial relays of small dimensions

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

Safety rope switch without reset for simple stop

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Operating Instructions. Angle Seat Control Valve. Type 7020

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Minimum 27 in-lb Torque

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Pressure chlorine changeover unit C 7520

M9208-xxx-x Series Electric Spring Return Actuators

I-BFV.KIT Butterfly Valve Gear Operator Replacement

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Actuators for Air and Gas Dampers

Non-Spring Return EconoDrive Floating Actuator

Minimum 27 in-lb torque

Overview of types. Technical data. Safety notes

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

ComfortPoint Programmable Lon, VAV/Unitary Controllers

LF Series Spring Return Direct Coupled Actuator

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

Position switches FC series

1 Phase electronic contactor (SC 1)

FSAF24(-S) US, FSAF120(-S) US

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

Function Relays, Interfaces and Converters

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Transcription:

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS TABLE OF CONTENTS 1.0 - WARNINGS 2.0 - GENERAL DATA 2.1 - Technical characteristics 2.2 - Data on electrical supply and consumption 3.0 - FIELD APPLICATION 4.0 - ELECTRICAL CONNECTION 4.1 - Opening cover of electric actuator 4.2 - Electrical connection 12-24 V AC/DC 4.3 - Electrical connection 110-230 VAC/DC 4.4 - Connection of signal auxiliary wires to the limit switches 4.5 - Wiring diagram 4.6 - Adjustment of actuator stroke 4.7 - Closure of electric actuator cover 5.0 - EMERGENCY OPERATION 5.1 - Working in emergency with battery (optional) 6.0 - MAINTENANCE 7.0 - VALVE AUTOMATION 8.0 - TRANSPORT AND STOCKING 1.0 Warnings Please read the following instructions before making any installation of the actuator The damages caused from the non-observance of these instructions are not covered in the warranty. This documentation must be kept in dry place and available for use. The installation and maintenance of electric actuator must be made only by qualified personnel. Before proceeding to the electrical connections, please make sure the ground wiring system works correctly. Please always check that supply voltage is included between the ones indicated on the label on the exterior of the actuator. Before making any maintenance on the actuator, always make sure to shut off the power supply. Valbia s.r.l. reserves the right to change the data and the characteristics of this manual at any time and with no notice in the scope of a constant updating of technological improvement. 2.0 General data Documentation unit Value Object of device - Electric actuator Construction type - Electronic control integrate device Protection level of cover - IP65 Cover type (UL50) - Ambient temperature range C F -20 C 55 C -4 F +131 F Rated voltage used and nature (auxiliary contacts) V 250 Vac / 30 Vdc Rated current and load (auxiliary contacts) A 1 A @ 250Vac - 1 A @ 30 Vdc (resistite load) Section of connections clamps conductors 2 mm 0,5-1,5 Maximum torque of clamps screws tightening Nm Lb.In 0,5 4,43 Maximum torques of cap screws tightening Nm Lb.In 2,5 22,15 Protection class against electric shock - Class II Blocking way of cables - Glandes PG11 Restriction of continue operation time (internal restrictions) sec. 120 Action type - Type 1 Level of pollution - Level III Category of overvoltage - III Product in conformity to the Community norm 73/23 CEE (LVD), 89/336/CEE (EMC), 93/68/CEE (CE Mark). 2.1 Technical characteristics The electric actuator VB015 has the heating resistor standard, always supplied. The option 110V and 230V have a synchronal motor which guarantees a rotation time not dependent from the torque. If the actuator has to face a torque higher than the foreseen maximum torque then the actuator trigger itself and keep a state of stress for an indicative period of 3 6 hours. The options at 12V and 24V AC/DC, in case the torque go over the maximum one foreseen, are projected to block automatically the actuator by taking off the electrical supply to the motor. This status keeps the electric actuator steady until a new impulse will be processed.

2.2 Supply data elec./consumption MOD. Nominal tension 12V ac/dc 24V ac/dc 110V ac 230V ac Nominal torque ( Nm) ( Lbs.in ) Current absorbed 1,2A 0,6A 75mA 25mA Absorbed power 15VA 15VA 6,6VA 6VA Frequency VB015 15 133 50/60 Hz Rotation time 0-90 (sec) 10 10 25 25 3.0 Field application VALBIA electric actuators have been designed and tested to operate ball and butterfly valvess for industrial sector. Actuators are available in standard version with rotation 0-90. On request we can supply actuators with rotation 0-180. For applications other than that above are needed please contact the VALBIA engineering. 4.0 electrical connection The connection has be done directly into the internal part of the actuator, by passing the cable through one of the two external glands PG11 (IP68). It is then necessary to open the upper cover in order to locate the terminal-block and the correct electronic supply. Please pay attention to the cabling and setting phases of electromechanical limit switches in order to avoid that fluids or other substance do not get in touch with any electronic part. Before assembling the upper cover please make sure that the o-ring is seated in the proper groove and there are no other instructions which could compromise the perfect tightness of cover. ATTENTION: Valbia electric actuators can work in any position, anyhow we do not suggest application where glandes are positioned up side-down, because this position could not guarantee a perfect tightness on glandes. In case the assembling of electric actuator and the electrical connection of itself are scheduled to be made in two different moments then please take care of the right closure of the glandes entrance. 4.1 Opening of actuator (fig.1) Remove position indicator (B) by loosening the screws (C). - Screw the fasteners (D) to remove the upper cover (A). - Raise up the cover (A) carefully to avoid to damage the internal electric parts. - Turn in the electric supply cable (diam. 6 9 mm / 0,24 0,35 inch) by the properly bolds (E) (PG11). - Proceed to connect the cable in its proper terminal-block (F) by looking at the wiring diagram (please also review the tag you find inside the cover) according to the different voltage ( fig.4 ). Fig.1 External view of actuator 2

4.2 Electrical connection for models supplied with 12-24V AC/DC (fig. 2 and 4) Electrical connection for model supplied with 12 AND 24V AC - The signal cable of closing (clockwise rotation) must be connected to the contact 1 (terminal block F ) - The signal cable of opening (counter-clockwise rotation) must be connected to the contact 2 (terminal-block F ). - The cable of neutral must be connected to the contact 3 (terminal-block F ) Electrical connection for model supplied with 12 AND 24V DC - Connect the contact 1 to the contact 2 ( terminal block F ) - Connect the contact 1 to the contact 4 for supplying the heater. - To get the control of opening (counter-clockwise rotation) please connect the positive pole to the contact 1 and the negative pole to the contact 3 ( terminal block F ). - To get the control of closing (clockwise rotation) please connect the negative pole to the contact 1 and the positive pole to the contact 3 ( terminal block F ). ATTENTION : the electric actuator VB015 has the double insulation and if supplied at 12 and 24 V DC then it does not need of ground wiring system. Terminal block F Fig.2 Plate for supply 12 and 24V DC and particular of terminal block F 4.3 Electrical connection for models with supply at 110-230V AC 50/60Hz (fig. 3 ) - The signal cable of closure (clockwise rotation) (signal of phase) must be connected to the input 1 of the terminal block F. - The signal cable of opening (counter-clockwise rotation) (signal of phase) must be connected to the input 2 of the terminal block F. - The signal cable of neutral must be connected to the contact 3 of the terminal block F. ATTENTION: the electric actuator VB015 has the double insulation and if supplied at 110-230 VAC then it does not need of ground wiring system. Terminal block F Fig.3 Plate of supply 110-230VAC/DC and particular of terminal block F 3

4.4 Connection of signal auxiliary wires to the limit switches (fig.4) These are 2 auxiliary contacts of limit switches (free contact) available on the terminal block G which is possible to connect to give signals to the end user. -To connect to the terminal block G between the contacts: - 7 and 8 to get the signal of closure. - 10 and 12 to get the signal of opening. Terminal block G Fig.4 View of terminal block G to connect to auxiliary signals 4.5 Wiring diagram (fig.5) The following figure shows the wiring diagram (also it is, as tag, inside the cover) to be followed for the proper cabling to the actuators. When the limit switches POS1 and POS2 are pressed they stopped the motor and so the opening and closing operation. Fig. 5 Electric wiring diagram to cable the actuators 4

5 4.6 Adjustment of actuator stroke (fig.6 ) The procedures to adjust the actuator stroke are as follows: 1. Take care there is not electrical supply 2. Remove the upper cover of the actuator ( see instructions point 4) 3. Take care that the device to be automatised (example: valve) is on OPEN position 4. The electric actuator VB015 has 2 discs camsholder, the upper one 2 orders the micro limit switches to control open and closed, while the bottom one 1 orders the auxiliary limit switches used to give the signal of opening and closure. For each camsholder there is a black cam, (opening rotation) and a white cam (closure rotation), the two cams are tighted by a screws 3. N.B. Please take care of the conditions of the limit switches by using a tools of electrical continuity. Fig. 6. Cams of the limit switch

4.7 Electric actuator case closing (fig.1) - After making the proper connection, please proceed to the assembling of cover A, by paying close attention not to hit any electronic parts. - Re-assemble the position indicator B on OPEN blocking it by screw C. - Make sure that the tightening of cables is secure, by screwing the gland E. - Finish the closure of the cover A by screwing in the fasteners D. 5.0 Emergency operation The electric actuator VB015 has an external handwheel B with position indicator, by which is possible to operate manually the closing and opening operations. The manual operation operates by working on the external handle H by turning it to the position MAN, at this point is possible to make the manual operation you like by working on handhweel B. To return to the automatic position please turn the handle H to position AUTO. Attention: do not operate the manual override when the actuator is working. 6.0 Maintenance These electric actuators do not need of any format maintenance. The internal lubrication is sufficient for the whole life of the actuator. To get a good cleaning of the external parts, we suggest to use a light detergent with low level of chemical aggressiveness. In case of damage or a problem in operation, we recommand that you send the actuators back to Valbia for inspection. Valbia s.r.l. declines all responsability and warrantee on our actuators repaired from any third party 7.0 Valve automation The mechanical assembling between the electric actuator and the item to be automated (for example: the valve) can be done by direct mounting or by a mounting kit. Both the cases you can verify the right alignment and the correct dimensions of the part to transmit the power in order to avoid axial stress which can damage valve and actuator. All Valbia electric actuators are in conformity of norm EN ISO 5211-DIN 3337. In order to have a right automation of the valve, is necessary to use a Valbia electric actuators whose range has a torque of at least 25% over the valve maximum torque. Do not raise up or moved the motorized valve by using the electric actuator as point of grip or hold. 8.0 Transport and stocking Valbia electric actuators are supplied in paperboard boxes which are of solid construction for a normal transport. Please handle and keep with care the cover until the moment of the installation of the actuator. The stocking of the material needs a dry and well ventilated place. Please take care also that it must be protected from temperature changes. 6