Micro-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw

Similar documents
Form C Renewable Energy Micro-Generation Connection Application Distribution System

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kva to 10 MVA or less)

PSNH INTERCONNECTION REQUEST

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

London Hydro Connection Checklist

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

GENERATOR INTERCONNECTION APPLICATION

If any further information is required for CHELCO to fulfill its reporting requirements, please let us know.

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Electric Utility Contact Information Indiana Michigan Power

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Distributed Generation Interconnection Policy

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

Enquiry Form (Non-Registered Generator With Capacity less than 5 MW)

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number:

Louisville Gas and Electric Company

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Bulletin Interconnection of electric power production sources Rules 2-010, , , , , , and

Solar Power Installation Application

PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION

NET METERING APPLICATION

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

APPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1

Net Metering Interconnection Requirements

Electrical Guidelines for Inverter-Based Micro-Generating Facility

3. Customer shall provide space for metering equipment and meter base as per Springville City Power requirements.

NET METERING ENROLLMENT APPLICATION REFERENCE GUIDE

Net Metering Service. Customer Information Package

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS

Request for Payment Instructions Rule 21 Export Submittal Instructions

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

Enquiry Form for Micro and Small Generators 5MW and Less

SCHEDULE NO. ACG33 NET METERING SERVICE

Inverter Advancements in UL1741 and UL 62109

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

RENEWABLE ENERGY PROGRAM Step 1, Section 1 ENROLLMENT FORM FOR LEASED RESIDENTIAL AND SMALL COMMERCIAL PHOTOVOLTAIC AND WIND TURBINE SYSTEMS

Consumer Guidelines for Electric Power Generator Installation and Interconnection

MCCOOK PUBLIC POWER DISTRICT McCook, Nebraska BOARD POLICY NUMBER 488

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

Umatilla Electric Cooperative Net Metering Rules

APPLICATION Net Energy Metering Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

Section 6. Generation Interconnection

Duke Energy Carolinas North Carolina Interconnection Request Checklist

California PUC Rule 21 Generating. Facility Interconnection Application Guide. Technical Note

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

December 13, This document was filed with the Board of Public Utilities on December 13, It is awaiting final approval by BPU staff.

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 25 kw)

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Guidelines for Inverter-Based Micro-Generating Facility (10 kw and Smaller)

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Request for Payment Instructions form. Rule 21 Non-Exporting Generators Submittal Instructions

P.O. Box 790 Kingston, ON, Canada, K7L 4X7 Phone: Fax:

Standards, Procedures and Policies for Grid Connection

Please Refer to Attached Sample Form

Request for Payment Instructions Rule 21 Non-Exporting Generators Submittal Instructions

REQUIREMENTS FOR GRID INTERCONNECTION OF RENEWABLE GENERATION SYSTEMS

TERMS AND CONDITIONS

APPLICATION Net Energy Metering (NEM2) Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

To complete the process for a net metering interconnection, please follow the steps below:

Minnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

Definitions. Scope. Customer Generation Interconnection Requirements

Micro Embedded generation

To complete the process for a net metering interconnection, please follow the steps below:

Application for release of capital subsidy on installation of Grid Connected Solar Power Plant

Inverter with MPPT and Suppressed Leakage Current

INTERCONNECTION RULES AND REGULATIONS FOR NET ENERGY METERING SYTEMS

HIGH PENETRATION RENEWABLE HYBRID POWER SYSTEMS TO MEET OFF-GRID COMMUNITY AND INDUSTRIAL ENERGY NEEDS

Please Refer to Attached Sample Form

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

Distributed Generation

White River Electric Association, Inc. Net Metering Information & Service Requirements

Application for Net Export Rebate

ENGINEERING SPECIFICATION

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

Standby Power Systems

Renewable Grid Integration Research in the U.S.

RULES FOR CUSTOMER INTERCONNECTION OF ELECTRIC GENERATING FACILITIES

Photovoltaic Installations

TANZANIA BUREAU OF STANDARDS

Power Purchase and Grid Connection Procedures

STATE OF NORTH DAKOTA DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS TABLE OF CONTENTS

Pretest Module 24 Three-phase Service Entrance

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Transcription:

This form is applicable to individual or multiple generating units at the Customer s facility with total nameplate rating of 10 kw or less. Your generation facility must generate electricity from a renewable energy source that is wind, water, solar radiation, or agricultural biomass. Inverter-based generating units must not inject DC greater than 0.5% of the full rated output current at the point of connection of the generating units. The generated harmonic levels must not exceed those given in the CAN/CSA-C61000-3-6 Standards. For generation size up to 10 kw, a Connection Impact Assessment will not be required and Westario Power Inc. will not perform such an assessment. There may be a limitation on the number of microgeneration facilities that can be connected to the same distribution feeder. IMPORTANT: All fields below are mandatory, except where noted. Incomplete applications may be returned by Westario Power Inc. Please return the completed form by email, mail or fax to: Westario Power Inc. Attn: System Reliability Department 24 Eastridge Road, R.R. #2 Walkerton, ON N0G 2V0 Email: microfit@westario.com Telephone: 519-507-6666 ext-232 FAX: 519-507-6790 Attention: Generation Connections NOTE: Applicants are cautioned NOT to incur major expenses until Westario Power Inc. approves to connect the proposed generation facility. Date of Application: (dd / mm / yyyy) 1. microfit reference number*: (*not required for Net Metering applications) 2. Project/Customer Name: 3. Proposed In-Service Date: (dd / mm / yyyy) 4. Project Information: Company/Person Contact Mailing address line 1 Mailing address line 2 Telephone Cell Fax Email 5. Project Location: Address Owner (mandatory) Engineering Consultant (Electrical) (optional) 1

City/Town/Township Lot Number(s) Concession Number(s) 6. Program Type: A. microfit (Complete all sections) B. Net Metering to microfit Conversion i) Existing Net Metering Customer upgrading generation size and/or technology/ fuel type, up to 10 kw (Complete all sections) ii) Existing Net Metering Customer with no upgrades in generation size and/or technology/ fuel type, up to 10 kw (Complete sections 6, 7 and 8 only) C. Net Metering (Complete all sections) 7. Customer Status: Existing Westario Power Inc. Customer? Yes No If yes, Westario Power Inc. Account Number: Name of Account Holder*: (*must be the same name as applicant) Are you a GST registrant? Yes No If yes, provide your GST registration number: - RT 8. Project Size: Number of Units Nameplate Rating of Each Unit kw Generator connecting on single phase three phase Existing Total Nameplate Capacity kw Proposed Total Nameplate Capacity kw 9. Fuel Type: Wind Turbine Solar/Photovoltaic Cells (Rooftop) Biomass Bio-gas Hydraulic Turbine Solar / Photovoltaic Cells (Groundmount) Bio-diesel Other (please specify): 2

10. Customer Owned Step-up Interface Transformer (if applicable): a. Transformer rating kva b. High voltage winding connection Delta Star Grounding method of star connected high voltage winding neutral Solid Ungrounded Impedance grounded: R X ohms c. Low voltage winding connection Delta Star Grounding method of star connected low voltage winding neutral Solid Ungrounded Impedance grounded: R X ohms Note: The term High Voltage refers to the connection voltage to Westario Power Inc. s distribution system and Low Voltage refers to the generator / inverter output voltage. 11. Generator / Inverter Information: (For generation facilities installing more than one type of generator, complete section 10) a. Manufacturer: b. Model No. c. Number of phases Single Phase Three Phase d. Nameplate rating: kw e. Generator / Inverter AC output voltage Volts f. Type of inverter: Self-commutated Line- commutated Other, please specify g. Are power factor correction capacitors automatically switched off when generator breaker opens? Yes No h. Is the generator / inverter paralleling equipment and / or design pre-certified and meets anti-islanding test requirements? Yes No i. If answer to the above question is Yes, to which standard(s), e.g. CSA C22.2 No. 107.1-01, UL1741, etc. j. Method of synchronizing the generator / inverter to Westario s system Manual Automatic k. Maximum inrush current upon generator or inverter connection (I inrush / I rated ) per unit 3

12. Grid Interface Controller (if applicable): a. Manufacturer: Model Number: 13. Type of Connection: Select the Single Line Diagram below that is appropriate for your connection to the Westario Power Inc. s distribution system: a. Diagram 1 - Net Metering Connection b. Diagram 2 - Parallel Metering Connection Diagram 1 - Typical Net Metering Connection Source: Solera Sustainable Energies Company Limited Diagram2 - Typical Parallel Metering Connection Source: Solera Sustainable Energies Company Limited 4

14. Connection to Westario Power Inc. s Distribution System: (To be completed by Westario Power Inc.) a. Connection voltage to Westario Power Inc. s distribution system: kv b. Station: c. Feeder: By submitting a Form C, the Applicant authorizes the collection by Westario Power Inc. ( WPI ), of the information set out in the Form C and otherwise collected in accordance with the terms hereof, the terms of WPI s Conditions of Service, WPI s Privacy Policy and the requirements of the Distribution System Code and the use of such information for the purposes of the connection of the generation facility to WPI s distribution system. 5