Back-UPS CS Back-UPS CS 350

Similar documents
Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Manual Back-UPS BR800/1100CI-IN

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

3000VA 120/208/230VAC

Installation and Operation Manual Back-UPS BR1000-CH

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Uninterruptible Power System

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Installation and Operation Smart-UPS SUA500PDR

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Up to 98% efficient under full load Similar runtimes to the previous 3u model

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Uninterruptible Power System

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

02/15/01. Powerware User s Guide VA.

MM-AVR UPS Series User s Manual

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

POWERWARE User s Guide VA.

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

Uninterruptible Power System

Uninterruptible Power Supply

POWERSTAR INC. Operations / Maintenance Manual Model: PS VA Tower UPS

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

UTILITY INPUT MAINS OUTLET

Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

3 Uninterruptible Power Systems

CP900EPFCLCD User s Manual K

3 Uninterruptible Power Systems

Eclipse Plus VA UPS and Surge Suppressor User s Manual

APC Smart-UPS Uninterruptible Power Supply Model 5000RMB User s Manual

Limousin II User Manual

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Installation and Operations Manual

BroadBand PowerShield. 20 AHr Battery. User Manual

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

PR1000ELCD / PR1500ELCD User s Manual

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

Informer Compact Series

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

APC Smart-UPS RT UXI/UXICH

Installation and Operation

Liebert PowerSure PSI UPS

DP140e. Installation & Operations Manual

User Manual. Smart-UPS. Uninterruptible Power Supply. 1000/1500 VA 100/120/230 Vac. 750XL/1000XL VA 120/230 Vac. Tower

Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

SecureUPS On-Line 120V AC Output, 1300VA

Liebert PSA VA. Installer/User Guide

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Pulsar EXtreme 2200C / 3200C

User Manual Back-UPS BE425M/425M-LM, BN450M/450M-CA

SUA1000I-IN / SUA1500I-IN 230 VAC

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Protection and conditioning against all forms of power anomalies.

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Uninterruptible Power Systems

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

3 Uninterruptible Power Systems

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

1. Important Safety Warning

Foreword

ALLIANCE SERIES OWNER'S MANUAL

Installation and Operation

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

User Manual V1.0 MaxiFlex 3000

Airpax Dimensions, Inc.

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Uninterruptible Power Systems

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

Transcription:

Back-UPS CS Back-UPS CS 350 APC Back-UPS CS, 210 Watts / 350 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, USB Includes: CD with software, Cord management straps, USB cable, User Manual Standard Lead Time: Usually in Stock

BK350 Features Battery failure Provides early-warning fault analysis on batteries enabling timely preventive notification maintenance Battery-protected and Reserves power capacity and run time for connected equipment that require surge-only outlets battery back-up while providing surge only protection for less critical equipment Cold-start capable Provides temporary battery power when the utility power is out. Serial Connectivity Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks. Hot-swappable Ensures clean, uninterrupted power to protected equipment while batteries batteries are being replaced Disconnected battery Warns when a battery is not available to provide backup power. notification Dataline Surge Provides protection of connected equipment from power surges on the data Protection lines. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Audible Alarms Provides notification of changing utility power and UPS conditions. User-replaceable Increases availability by allowing a trained user to perform upgrades and batteries replacements of the batteries reducing Mean Time to Repair (MTTR) USB Connectivity Provides management of the UPS via a USB port (not available on all models). Serial Connectivity Provides management of the UPS via a serial port. Transformer-block Protect equipment with input transformer blocks without blocking access to spaced outlets other receptacles. Intelligent Battery Maximizes battery performance, life, and reliability through intelligent, Management precision charging. Safety-agency Ensures the product has been tested and approved to work safely with the approved connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. Lifetime data recovery Provides peace of mind by providing professional data recovery services in warranty the event data is lost due to the failure of the unit. Battery replacement Allows quick, easy battery replacement. without tools LED status indicators Quickly understand unit and power status with visual indicators. Back-UPS CS Features & Benefits Protection Data line surge protection Battery-protected and surge-only outlets Convenience Protects connected loads from surges, spikes, lightning, and other power disturbances. Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment LED status indicators Quickly understand unit and power status with visual indicators.

Audible Alarms Transformer-block spaced outlets Automatic self-test Battery replacement without tools Availability Cold-start capable Hot-swappable batteries Automatic restart of loads after UPS shutdown Resettable circuit breakers Safety Safety-agency approved Provides notification of changing utility power and UPS conditions. Protect equipment with input transformer blocks without blocking access to other receptacles. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Allows quick, easy battery replacement. Provides temporary battery power when the utility power is out. Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatically starts up the connected equipment upon the return of utility power. Enables a quick recovery from overload events. Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.

Output Output Power Capacity Max Configurable Power Nominal Output Voltage Waveform Type Output Connections 210 Watts / 350 VA 210 Watts / 350 VA 120V Stepped approximation to a sinewave (3) NEMA 5-15R (Battery Backup) (3) NEMA 5-15R (Surge Protection) Input Nominal Input Voltage Input Frequency 120V 50/60 Hz +/- 3 Hz (auto sensing) Input Connections NEMA 5-15P Cord Length Input voltage range for main operations 1.83 meters 98-140V Batteries & Runtime Battery Type Typical recharge time Replacement Battery Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof 8 hour(s) RBC2, RBC2J RBC Quantity 1 Typical Backup Time 20.7 minutes (105 Watts) at Half Load Typical Backup Time 5.6 minutes (210 Watts) at Full Load Runtime Chart Back-UPS CS Energy Use/Efficiency

Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and resistive load output. View Enlarged Chart Communications & Management Interface Port(s) Control panel Audible Alarm DB-9 RS-232,USB LED status display with On Line : On Battery : Replace Battery and Overload indicators Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Surge Protection and Filtering Surge energy rating Filtering Data Line Protection 1020 Joules Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 RJ-11 Modem/Fax/DSL protection (two wire single line) Physical Maximum Height 165.00 mm Maximum Width 91.00 mm Maximum Depth 284.00 mm Net Weight 5.68 KG Shipping Weight 6.36 KG Shipping Height 263.00 mm Shipping Width 175.00 mm Shipping Depth 357.00 mm Master Carton Units 2.00

Master Carton Weight 29.00 lbs. Color Beige SCC Codes 1073130401629 5 Units per Pallet 80.00 Environmental Operating Environment 0-40 C Operating Relative Humidity 0% Operating Elevation 0-3000 meters Storage Temperature -15-45 C Storage Relative Humidity 0% Storage Elevation 0-15000 meters Audible noise at 1 meter from surface of unit Online Thermal Dissipation 45.00 dba 20.00 BTU/hr Conformance Regulatory Approvals Standard Warranty FCC Part 68,TUV 3 years repair or replace **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

Troubleshooting Use the tables below to solve minor Back-UPS installation and operation problems. Consult APC On-line Technical Support or call APC Technical Support for assistance with problems that cannot be resolved using this document: Possible Cause Back-UPS will not switch on Back-UPS not connected to an AC power source. Procedure Check that the Back-UPS power plug is securely connected to the wall outlet. Back-UPS Storage Before storing, charge the Back-UPS for at least eight hours. Store the Back-UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature 23 o to 86 o F (-5 o to 30 o C) 86 o to 113 o F (30 o to 45 o C) Recharge Frequency Charging Duration Every 6 months Every 3 months 8 hours 8 hours Please contact APC Technical Support to troubleshoot the unit before returning it to APC. Back-UPS circuit breaker tripped. Very low or no utility voltage. Disconnect non-essential equipment from the Back-UPS. Reset the circuit breaker (located on the rear panel of the Back-UPS) by pushing the circuit breaker button fully inward until it catches. If the circuit breaker resets, switch the Back-UPS on and reconnect the equipment one-at-a-time. If the circuit breaker trips again, it is likely that one of the connected devices is causing the overload. Check the wall outlet that supplies power to the Back-UPS using a table lamp. If the lamp bulb is very dim, have the utility voltage checked by a qualified electrician. Order Replacement Battery The typical battery lifetime is 3-6 years (depending on the number of discharge cycles and operating temperature). A replacement battery can be ordered over the phone from APC, or the battery can be ordered on-line from the APC web site (see below, a valid credit card is required). When ordering, please specify Battery Cartridge RBC2. Battery Replacement Battery replacement is a safe procedure. The Back-UPS can be left on with the equipment connected during this procedure. Do not replace the battery when the Back-UPS is On Battery. Refer to the APC Safety Guide for additional information. Please consult the "Connect Battery" diagrams (a through d) on the front page of this document when performing the following procedures: Back-UPS does not power computer/monitor/external drive during an outage Internal battery is not connected. Computer, monitor or external disk/ CD-ROM drive is plugged into a Surge Only outlet. Check the battery connections. (See Connect the Battery under Installation on the front page of this document. Move computer, monitor, or external drive power cord plug to the Battery Backup outlets. Back-UPS operates on battery although normal utility voltage exists Back-UPS circuit breaker tripped. The wall outlet that the Back-UPS is connected to does not supply utility power to the unit. Disconnect non-essential equipment from the Back-UPS. Reset the circuit breaker (located on the rear panel of the Back-UPS) by pushing the circuit breaker button fully inward until it catches. Back-UPS does not provide expected backup time Back-UPS is excessively loaded. Back-UPS battery is weak due to recent outage and has not had time to recharge. Battery requires replacement. A red indicator is lit Battery is not connected properly. The Overload indicator is lit if equipment connected to the Battery Backup outlets is drawing more power than the Back-UPS can provide. Battery requires replacement. Red indicators are flashing Back-UPS failure. Specifications Connect the Back-UPS to another wall outlet or have a qualified electrician check the building wiring. Unplug non-essential Battery Backup connected equipment, such as printers and plug them into Surge Only outlets. Note: Devices that have motors or dimmer switches (laser printers, heaters, fans, lamps, and vacuum cleaners, for example) should not be connected to the Battery Backup outlets. Charge the battery. The battery charges whenever the Back-UPS is connected to a wall outlet. Typically, eight hours of charging time are needed to fully charge the battery from total discharge. Back-UPS run-time is reduced until the battery is fully charged. Replace battery (see Order Replacement Battery). Batteries typically last 3-6 years, shorter if subjected to frequent power outages or elevated temperatures. Check the battery connections. Consult "Connect the Battery" under "Installation" on the front page of this document. It shows how to access the battery and connect the wires. Move one or more equipment power plugs to the Surge Only outlets. The battery should be replaced within two weeks (see "Order Replacement Battery"). Failure to replace the battery will result in reduced run-time during a power outage. Call APC for service. Replace Battery indicator lit and an alarm sounds when the Back-UPS is turned on Internal battery not connected. Check the battery connections. Consult "Connect the Battery" under "Installation" on the front page of this document. It shows how to access the battery and connect the wires. 1. While viewing the Back-UPS from the front, lay the Back-UPS on its left side (diagram a). 2. Slide the battery compartment cover off of the Back-UPS (diagram a). 3. Grasp the tab attached to the battery and slide the battery partially out of the case. Grab the battery firmly and pull it straight out. The battery wires will disconnect as the battery is pulled out (diagram b). 4. Carefully unpack the new battery. Retain the packing carton so that the old battery can be recycled. 5. Insert the new battery halfway into the Back-UPS (diagram d). 6. Connect the wires to the new battery as follows: 7. Red Wire - to red (positive) terminal 8. Black Wire - to black (negative) terminal 9. Note: Small sparks at the battery terminals are normal during connection. 10. Carefully insert the battery fully into the Back-UPS. 11. Slide the battery compartment cover back into place. 12. The Replace Battery indicator will shut off within the 14-day self-test interval, or when the Back- UPS is switched On. The old battery must be recycled. Deliver the battery to an appropriate recycling facility or return it to APC in the packing carton that came with the new battery. Additional recycling information is provided with the new battery. Service If the Back-UPS arrived damaged, notify the carrier. If the Back-UPS requires service, do not return it to the dealer. The following steps should be taken: 1. Consult the Troubleshooting section to eliminate common problems. 2. Verify that the circuit breaker is not tripped. A tripped circuit breaker is the most common Back- UPS problem. 3. If the problem persists, consult APC On-line Technical Support or call APC Technical Support (see below). When calling APC Technical Support, have the Back-UPS model number, serial number and date of purchase available. Be prepared to troubleshoot the problem over the phone with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address. A Back-UPS under warranty will be repaired at no cost. The standard warranty is two (2) years from the date of purchase. APC s standard procedure will be to replace the original unit with a factory reconditioned unit. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement to the customer. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. If the warranty has expired, there is a repair charge. For return: Disconnect the red battery terminal wire from the Back-UPS battery (see "Connect the Battery" instructions and graphics on the front of this document). Department of Transportation (DOT) regulations require that the battery wire be disconnected before shipping the Back-UPS to APC. Pack the Back-UPS in its original packaging. If the original container is not available, contact APC Technical Support to obtain a a new set. Pack the Back-UPS properly to avoid damage in transit. Never use styrofoam beads for packaging. Damage sustained in transit is not covered under the warranty (insuring the package for full value is recommended). Write the RMA number on the outside of the package. Return the Back-UPS to APC by insured, prepaid carrier to the address provided by APC Technical Support. Warranty Input Voltage (on line) Frequency Limits (on line) On Battery Waveshape Maximum Load Typical Recharge Time Operating Temperature Storage Temperature Operating and Storage Relative Humidity Size (H x W x D) Weight Shipping Weight EMI Classification On Battery Run-Time 98-132 Vac 47-63 Hz (autosensing) Stepped Sine Wave 350 VA - 210 W 500 VA - 300 W 8 Hours 32 o to 104 o F (0 o to 40 o C) 23 o to 113 o F (-5 o to 45 o C) 0 to 95% non-condensing 6.5 x 3.6 x 11.2 inches (16.5 x 9.2 x 28.5 cm) 350 VA - 12.5 lb (5.7 kg) 500 VA - 13.8 lb (6.3 kg) 350 VA - 14.0 lb (6.4 kg) 500 VA - 15.3 lb (7.0 kg) FCC/DOC Class B Certified 20 Minutes typical - desktop computer and 15 inch (38.1 cm) monitor. The standard warranty is two (2) years from the date of purchase. APC s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement to the customer. Copyright 2002 American Power Conversion. All rights reserved.