iseries-s (Setpoint) Mixing Valve

Similar documents
SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID#

SUPERSEDES: August 1, 2003 EFFECTIVE: August 15, 2005 Plant ID#

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID#

Instruction Sheet. Variable Speed - Setpoint (00-VS) 00 and Load Match Cartridge Circulators

TDX - Taco Duplex Starter with

Submittal Data Information

2-WAY AND 3-WAY MOTORIZED VALVES FOR STEAM, VACUUM AND HOT WATER APPLICATIONS

Submittal Data Information

Twin-Tee. Hydronic Accessories

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8

7 ZONE VALVES. Applications

Pre-plumbed Blowdown Assembly ½ Model

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

Introduction. System Components

TC62D Installation Instructions

INSTALLATION/OPERATING INSTRUCTIONS VSP. A Variable Speed Pump Control

Raptor 085HB-270HB & 155CB Submittal

Raptor 085HB-270HB & 155CB Submittal

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

SetPoint 501 and 501s Controllers Installation and Operation Manual

L404F,T,V PressureTrol Controllers

MV100 Electric Controllers T100, T200 Thermostatic Controllers and V2000 Radiator Valves

Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

Operation and Installation Manual

INSTALLATION AND OPERATION INSTRUCTIONS. Variable Speed Pump Control

- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08

SetPoint 150 Controller Installation Manual

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

PARTS LIST PRESSURELESS COOKER MODELS: GSX-5HE, GSX-7HE, GSX-10HE

Product Instructions. Mixing Station. Features. Specifications. Materials

Composite PEX-AL-PEX Tubing

DOMESTIC HOT WATER TEMPERATURE CONTROL WITH SAFEGUARD

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Motorized Tempering Valves with Transformers for

SE8300 Series Installation Guide 24 Vac Low Voltage

OptiRamp Rational SCADA

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

INSTALLATION INSTRUCTION

3 & 4-Way Rotary Valves

- Wiring Brochure Mixing Expansion Module 440

Accessories. UP timer. Timer control. Approvals. UP Series

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

T100A,F,M Controllers

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Hydronic Accessories H YDRONIC C OMPONENTS & S YSTEMS. Taco Catalog # Supersedes: Dated: 02/1/01

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Product Catalog. Just because it s in the floor doesn t mean it s INFLOOR.

Hamilton 3VO Submittal

VEP-11/12/21/22 Series

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Stainless-steel Manifold Assembly, 1" with Flow Meter Submittal Information Revision B: Sept. 4, 2014

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

YCCS TE-6800 Series Temperature Sensors

Replacement Elements

Remote Temperature Controllers. Quick Selection Guide

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

ELECTRONIC THERMOSTAT: T901

Erie VM PopTop Series Modulating Valves

Digital Room Thermostats with Touch Screen LCD

V5013B,C,F Three-Way Mixing and Diverting Valves

Healthcare Solutions Room Pressure Monitors and Controls

CLIMA. Take Control of Your System with. Gain Efficiency -> Save Energy. technological solutions

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

MrPEX 1 ½ " Brass Manifold Installation Guide

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

INSTALLATION/OPERATING INSTRUCTIONS MCP

Power Supplies DORMA PS

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Premounted Midi Shunts

Description. functions including single duct pressure dependent or pressure independent systems.

Engineering & Design Data

4900 Series Air Separators Standard & High Velocity

Erie VT/VS PopTop Series Two Position Spring Return Valves

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

Temperature Controllers

6. Mounting. 7. Rough-in. 8. Settings. 10. Quick

Cv Values L & T-PORT 90 T-PORT STRAIGHT THRU

Specifications & Submittal

Temperature Controllers

Single-Valve Powerstation

100 Series - High Performance Plastic Valves. Water Control Solutions

Wirsbo Radiant Heating System

GL-235 Solar Pool Controller

Aquatrac Instruments Application Note

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

- Wiring Brochure Universal Reset Module 422

INSTALLATION INSTRUCTION

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

- Wiring Brochure Universal Reset Module 422e

Transcription:

Taco Radiant ade Easy pplication Guide (Setpoint) ixing Valve Products & pplications P06 EFFECTIVE:ugust 15, 2005 SUPERSEDES: arch 1, 2004 OVERVIEW (Setpoint) ixing Valve Use the Taco Setpoint ixing Valves instead of a thermostatic mixing valve for precise dial-in supply water temperature control to a heating system. The direct drive microprocessor-based actuator modulates a 2-way, 3-way or 4-way valve to inject different rates of hot water into the cooler system return water. In combination with the optional boiler protection sensor, the iseries valves provide the unique benefit of optimal temperature control with boiler protection. The setpoint temperature is adjustable from 80ºF to 180ºF using a dial located on top of the actuator. 15ºF setback of the supply water can be initiated for additional unoccupied or nighttime setback control. n external multi-status LED indicator light, plug-in wiring connections and an easy to remove actuator makes installation and diagnostics a snap. DESIGN When using an ixing Valve, the following piping requirements must be considered for proper operation (see Figures 1, 2 and 3). 1. In order to hydraulically isolate the boiler loop from the injection or system loop primary/secondary piping must be used. There must be no more than 4 pipe diameters between the tees in the boiler loop (Note 1). 2. There must be at least 6 pipe diameters of straight pipe on either side of the tees (Note 2) in order to prevent the momentum of water in the boiler loop from pushing flow through the injection loop. 3. There should be a minimum of 1 foot drop on the return pipe of the injection loop, in order to create a thermal trap (Note 3) and prevent unwanted heat transfer. 4. When using a 2-way ixing Valve, a balancing valve must be located between the tees in the system loop, in order to provide a pressure drop to induce flow through the mixing loop. Figure 1 System alancing Valve Injection Valve Note 3 Note 2 Note 1 Features: 2-way injection or 3-way mixing Operates off constant power or relay end switch all valve design, high Cv anual operation button Solid state microprocessor design Compact design Easy, one-handed actuator removal 125 PSI shutoff pressure Plug-in low voltage connections ulti-status LED indicator light Fail safe mode sensor included djustable setpoint dial (80 F to 180 F) Selectable 15 F setback Optional boiler protection (set at 135 F)

Figure 2 Figure 3 System C Note 3 Note 2 Note 1 System Note 1 Note 3 Note 2 VLVE SIZING ND SELECTION 2-way ixing Valve Selection In order to properly size the 2-way ixing Valve, follow the design procedure below: 1) Determine the design radiant heating load. 2) Determine the design boiler supply temperature. 3) Determine the radiant system return temperature which is based on the design temperature drop across the radiant system. 4) Determine the design injection flow rate using the following equation: Eq. 1: Design Injection Flow Rate (US GP) = Design Radiant Heating Load (TU/hr) 500 x ( - Radiant System Return) 5) From the 2-way Cv chart below, select the valve size with the closest Cv value to the injection flow rate calculated in step 4. Do not size the 2-way ixing Valve based solely on pipe size. iseries: 2-way Cv Size Cv 1 2 " 4.9 3 4 " 10.3 1" 8.9 3-way ixing Valve Selection Select the 3-way ixing Valve based on the 3-way Pressure Drop chart below. Flow GP 1 2 1 1 1 2 2 4 6 8 1 2 " (Cv = 1.5) PSI Ft. Head 0.11 0.26 iseries: 3-way Valve Pressure Drop 3 4 " (Cv = 3.3) 1" (Cv = 3.0) PSI Ft. Head PSI Ft. Head 0.02 0.05 0.03 0.06 0.44 1.03 0.09 0.21 0.11 0.26 1.00 2.31 0.21 0.48 0.25 0.58 1.78 4.11 0.37 0.85 0.44 1.03 1.47 3.39 1.78 4.11 3.31 7.64 4.00 9.24 5.88 13.58 P06 2

4-way ixing Valve Selection Select the 4-way ixing Valve based on the 4-way Pressure Drop chart below: Flow GP 1 2 1 2 4 6 8 10 12 14 16 18 20 3 4 " (Cv = 7.0) PSI Ft. Head 0.01 0.01 iseries: 4-way Valve Pressure Drop 1" (Cv = 9.3) 1 1 4 " (Cv = 17.5) PSI Ft. Head PSI Ft. Head 0.00 0.01 0.00 0.00 0.02 0.05 0.01 0.03 0.00 0.01 0.08 0.19 0.05 0.11 0.01 0.03 0.33 0.75 0.18 0.43 0.05 0.12 0.73 1.69 0.42 0.96 0.12 0.27 1.31 3.01 0.74 1.71 0.21 0.48 2.04 4.71 1.16 2.67 0.33 0.75 2.94 6.79 1.66 3.84 0.47 1.08 4.00 9.24 2.28 5.27 0.64 1.48 2.96 6.84 0.84 1.93 3.76 8.70 1.06 2.44 2.30 5.31 OPERTION Power Up and Heat Request Whenever the is powered up, the LED turns green and the control starts operation. The power to the may be switched through an end switch (e.g. Taco ZVC/SR style zone control), a thermostat for intermittent operation, or a power source (24 vac) may be connected directly to the for continuous operation. Setpoint The operates the valve to maintain a fixed setpoint. The setpoint temperature is set using the Setpoint dial located on the top of the actuator.the setpoint range available is from 80ºF to 180ºF. Protection Return (optional) 120 130 140 110 150 100 160 90 170 80 F 180 F SETPOINT n optional boiler return sensor (Taco part #9300-2044RP) can be installed to provide boiler protection.when the boiler return temperature is below 135ºF, the green LED fiashes rapidly (reduced output) and the modulates towards the closed position in order to allow the boiler temperature to recover. Setback The has a setback function used to lower the setpoint target.the setpoint target is lowered by 15ºF whenever there is a contact closure across the SETCK and SENSOR COON terminals. System OILER SUPPLY SETCK Setback Input POWER GREEN SENSOR ERROR RED C R 24 VC POWER SENSOR COON 24 V (ac) Transformer End Switch P06 3

INSTLLTION 2-way Installation For installations where boiler protection is NOT required, the optional boiler sensor does not need to be installed. 2-way Valve 2-way Valve with Low Temperature Zones 2-way Valve with Low Temperature Zones ultiple 2-way Valves - Low Temperature System ultiple Temperature System C C ultiple Temperature System P06 4

3-way Installation For installations where boiler protection is NOT required, the boiler sensor does not need to be installed. C 3-way Valve C 3-way Valve with Low Temperature Zones C 3-way Valve with Low Temperature Zones C C C ultiple Low Temperature System C C ultiple Temperature System P06 5

3-way Installation (continued) For installations where boiler protection is NOT required, the boiler sensor does not need to be installed. C C P ultiple Temperature System C P High ass 3-way Valve with High Temperature Zones (lternate Piping) C ultiple Temperature System C C ultiple Temperature System P06 6

4-way Installation For installations where boiler protection is NOT required, the boiler sensor does not need to be installed. 4-way Valve Low Temperature System 4-way Valve with Low Temperature Zones ultiple Temperature System 4-way Valve with Low Temperature Zones ultiple Temperature System ultiple 4-way Valves - Low Temperature System ultiple Temperature System P06 7

Radiant ade Easy TCO, INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 FX: (401) 942-2360. TCO (Canada), Ltd., 6180 Ordan Drive, ississauga, Ontario L5T 23. Telephone: 905/564-9422. FX: 905/564-9436. Visit our web site at: http://www.taco-hvac.com Printed in US Copyright 2005 TCO, Inc. P06 8