Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Similar documents
Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

Installation Instructions

Cable-Operated Disconnect Switches. Accessories

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Kits for 125A, 150A 250A and 400A Frame Sizes

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

600V, Non-Fusible, (3-Pole, 3 Phase)

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Installation Instructions for Replacement Mechanism Kit

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

CCP2-FLR1-21_ flange-rod operating mechanism

OPERATOR ADAPTER A21ABA

GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

COOKSON OWNER'S MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

Product Guide. NEMA pump controls.

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

TOYOTA SIENNA TRAILER WIRE HARNESS Preparation

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Installation Instructions

EXTERNAL DISCONNECT ENCLOSURE INSTALL

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

TMT Boxer 24v slider motor installation notes from EasyGate

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

Installation Instructions

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Installation Instructions

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Patriot. Aluminum and Steel 5spring. Step #1 Tarp Spool with Gear Motor (Includes Instructions for Optional Wind Deflector)

Camaro/Trans Am V3 T6 Kit Installation Instructions

CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch

Load Break Disconnect Switches FSLBS

UL/CSA Non-fused Disconnect Switches

Big performance in a small package

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

1494U Visible-Blade Disconnect Switch

Safety Interlock Switches

Design Standard. Purpose: Design Standard:

Installation Instructions

Parkit360 Transformer

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Operation and Maintenance Manual

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Installation Instructions

Rider 120 S, 120 SE Rider Rider 140 to series EE Rider 140 from series FF Cutter decks Accessories...

w w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.

Preferred Cutout, Disconnect Enclosure, Type 12

INSTALLATION INSTRUCTIONS AM rev. A

AE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12

WARNING! THIS PRODUCT MUST BE INSTALLED BY A TRAINED, AUTHORIZED RICON SERVICE TECHNICIAN.

Installation Instructions For Motor Control Center (MCC) Units

Owner s Manual Read and keep this manual. Patents World Wide

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Actuators & Surface Safety Valves

Pneumatic Isolation Module

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

SPEEDFAX TM 2011 Disconnect Switches Contents

SEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N

Registers for spiral ducts

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Prevents Unscheduled Truck Departures

Publication: PDI-010 Date: March 5, 2010 Model: UXV 500

ch2200 ch2300 mt3 osprey pro-trim single s twin s sl-3 INSTALLATION INSTRUCTIONS AND OWNERS MANUAL

Quick Connection Panel (QCP) Installation Guide

BINNACLE MOUNT REMOTE CONTROL INSTALLATION AND USER S GUIDE

Wheel Horse. 36 Tiller. Model No & Up. Operator s Manual

NEVER STOP CORRUGATE OPENER

INSTALLATION & OWNER S MANUAL

I N ST R UC T I ON MODEL 5614 MEAT SAW MODEL ML (Starting Serial Number ) FORM Rev. A (11-95) MEAT SAWS

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

OPERATOR ADAPTER ABF

DODGE SuperRail Mounting Kit #0848

SECTION V ASSEMBLY CAUTION THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE THOROUGHLY UNDERSTOOD BEFORE ATTEMPTING MACHINE ASSEMBLY.

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

REV READ BEFORE INSTALLATION OF KIT:

Transcription:

Bulletin 494C Cable Operated Disconnect Switch Kit () Installation Instructions (Cat 494C- _ Series : ) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator. Table of Contents Page Quick Installation Guide - Disconnect Switch Installation,3 - Disconnect Handle Installation 3 - Assemble and Install Line Terminal Guard 4 - Cable Mechanism Installation 4 - Connecting Rod Adjustment Procedure 5 Enclosure Without Handle Cutout 6 - Locate Handle - Drill Handle Holes Door Catch Mounting Bracket Installation 7 Trailer Fuse Block Installation () 8 Phase Barrier Replacement () 9 Fuse Clip Installation () 0 Bulletin 494C Cable Operated Disconnect Switch Kit Components Bulletin 494C Cable Operated Disconnect Switch Kit Optional Accessory List

QUICK INSTALLATION GUIDE IMPORTANT: When locating the switch, verify that the minimum diameter for the loop of the cable between the switch mechanism and handle mechanism is not less than 6 inches. Any reduction to the diameter of the bend loop for the cable will reduce the efficiency of the cable system, and create additional drag and friction within the cable conduit. IMPORTANT: Verify that the cable assembly does not interfere with any mechanical and moving parts. Keep the cable conduit a minimum of /" from all heat sources and current carrying terminals, fuses, transformers, etc. Disconnect Switch Installation Switch Size Panel Mounting Dimensions AA BB CC DD EE (4) Mounting Plate Holes " " 4-3/4" -3/8" 9/3" Dia. FF Minimum Bend Diameter 6" Dia. a Locate switch with right hand mechanism EE AA EE AA BB BB DD DD CC CC Enclosure with Right Hand Flange FF FF Enclosure with Left Hand Flange b Locate switch with left hand mechanism AA EE AA EE BB BB DD DD CC CC Enclosure with Right Hand Flange FF FF Enclosure with Left Hand Flange ()

Disconnect Switch Installation (Cont'd) Assemble disconnect switch to cable switch mechanism 3 Assemble disconnect switch assembly to mounting plate 90-30 lb-in () Thread forming screws provided with disconnect switch. Disconnect Switch with Right Hand Cable Mechanism (shown) Thread forming screws provided with cable mechanism. 90-30 lb-in () 4 Install rubber handle on line terminal guard 5 Install the line terminal guard on disconnect switch LINE TERMINAL GUARD LINE TERMINAL GUARD Disconnect Handle Installation Install gasket Install handle and mechanism bracket 3 Install defeater lever 60-80 lb-in (Right Hand Flange Mounted Shown) NOTE: Apply grease from capsule to gasket or groove to retain gasket to handle. 7- lb-in (3)

3 Cable Mechanism Installation Verify that disconnect switch and handle are in "ON" position. (Switch blades will not be visible) Rotate connecting rod (clockwise) into drive bar until it begins to exit the drive bar (approximately 8 full turns). 3 Align connecting rod with primary link Connecting Rod Primary Link (4)

3 Cable Mechanism Installation (Cont'd) 5 Install hitch pin clip 6 Turn disconnect handle "OFF" and install handle mechanism spring Hitch Pin Clip 4 Connecting Rod Adjustment Procedure "ON" Position ➊ Move disconnect handle to the "ON" position. ➋ If switch does not fully close, return handle to "OFF" position. ➌ Remove link spring hitch pin and disengage the connecting rod from the primary link. ➍ Turn connecting rod counter-clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring. "OFF" Position ➊ Move disconnect handle to the "OFF" position. ➋ If switch does not fully open, return handle to "ON" position. ➌ Remove hitch pin and link spring, then disengage the connecting rod from the primary link. ➍ Turn connecting rod clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test. ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring. ATTENTION: CHECK FOR PROPER OPERATION. Upon completion of the installation instructions, no further adjustment of the cable mechanism is required. (5)

Enclosure without Handle Cutout Enclosures with a Flange Thickness less than 3/6" use dimensions below to install disconnect handle. Locate Handle -/8" -/8" -3/8" -3/8" 4-3/8" 4-3/8" Top Handle Hole Right Hand Flange Left Hand Flange Drill Handle Holes ().38 Dia. Holes Top Handle Hole 5/6" /" /4" 5-/" 6-/" Square corners or up to /4" radius (6)

Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures) Door Catch Mounting Bracket: Provided with projections for welding. Projections can also be used as a guide for drilling holes. Can be used as a template to drill corresponding holes in the enclosure door. User to supply the hardware for fastening the bracket. Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. The bracket hardware must be inaccessible to unauthorized personnel. Dimension K (3/4" to ") When using large disconnect handle kit only (494F-M or -S), use door catch provided with handle kit. When using large disconnect handle kit and small door hardware kits (494V-L, -LL, -L or -LL), use door catch provided with door hardware kit. Dimension K (-/8" to -3/8") When using large disconnect handle kit and large door hardware kits (494V-L3 or -LL3), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top TOP VIEW Door Catch Enclosure Door Door Catch Mounting Bracket Flange Thickness K Door Catch - /8" - 5/8" - 3/8" Enclosure Base -/8" -/8" -3/8" -3/8" 4-3/8" 4-3/8" 3-3/4" 3-3/4" Top Handle Hole Door Catch Mounting Bracket -5/8" -5/8" Door Catch Mounting Bracket Right Hand Flange (7) Left Hand Flange

Trailer Fuse Block Installation (Switch Rating ) Trailer Fuse Block Location Note: Refer to the figures and chart below to determine the location on the mounting plate for the trailer fuse block. (Not required for non-fusible disconnect switch applications.) 494V-FS400 400 Amp Trailer Fuse Block (494V-FS400) Fuse Torque (lb-in) A Amps Voltage Class Fuse Fuse Lug to Wire Block Clip Terminal into Lug 00 00 00 00 400 400 400 400 50 600 600 600 50 600 600 600 H/R H/R J HRCII-C H/R H/R J HRCII-C 7-/6" 0-3/6" 6-3/8" 6-3/8" 8-/6" -/6" 7-3/6" 8-/6" 90-30 90-30 6-75-00 75-305 -37 75-00 75-305 A 4-3/4" Install Trailer Fuse Block 494V-FS400 (See Table ) (8)

Phase Barrier Replacement Kit (Switch Rating ) 494F-PH5 3 0-30 lb-in 4 CLICK Terminal Adapter Installation - Conversion from Fusible to Non-Fusible (Switch Rating ) 90-0 lb-in 3 75-00 lb-in 35-50 lb-in (9)

Fuse Clip Installation (Switch Rating ) Switch for Right Hand Mechanism Switch for Left Hand Mechanism 00A Fuse Clips Fuse Clips 6 - lb-in - 37 lb-in 00A Fuse Clips Fuse Clips 6 - lb-in - 37 lb-in Switch for Right Hand Mechanism Switch for Left Hand Mechanism 00A Fuse Clips Fuse Clips 3-37 lb-in 40-55 lb-in 00A Fuse Clips Fuse Clips 3-37 lb-in 40-55 lb-in (0)

Bulletin 494C Cable Operated Disconnect Switch Kit Components Disconnect Switch Kit Cat No. Handle 494F-M (7-/" Painted Metal) ( - 600A) 494F-S (7-/" Stainless Steel) ( - 600A) Switch Switch for Right Hand Mechanism 494F-D400 () Switch for Left Hand Mechanism 494F-DX400 () Cable Mechanism Cable with Right Hand Mechanism 494C-CM9: (4 Ft Cable) 494C-CM0: (5 Ft Cable) 494C-CM: (6 Ft Cable) 494C-CM: (0 Ft Cable) Cable with Left Hand Mechanism 494C-CMX9: (4 Ft Cable) 494C-CMX0: (5 Ft Cable) 494C-CMX: (6 Ft Cable) 494C-CMX: (0 Ft Cable) Fuse Block 494V-FS400 () Fuse Clips 40-N45 (Class H,J, 00A - 50V, 00A - 600V) 40-N46 (Class H,J, - 50V, - 600V) 40-N54 (Class R, 00A - 50V, 00A - 600V) 40-N55 (Class R, - 50V, - 600V) ()

Bulletin 494C Cable Operated Disconnect Switch Kit Optional Accessory List Optional Accessories (Installation Instructions Not Included) Cat No. Electrical Interlock Switch with Right Hand Mechanism 495-N43 (-N.O./N.C.) (00A - ) 495-N44 (-N.O./N.C.) (00A - ) Switch with Left Hand Mechanism 495-N4 (-N.O./N.C.) () 495-N4 (-N.O./N.C.) () Auxiliary Contact 495-N8 (-N.O.) (30A - ) 495-N9 (-N.C.) (30A - ) Auxiliary Contact Adapter Kit 495-N5 (00A - ) (Required only for switch with Left Hand Mechanism) Wire Lug Connectors 494R-N4 (CU Wire Size ( ) - #/0-50 MCM () 494R-N5 (CU Wire Size #4...500 MCM () Phase Barrier 494F-PH5 () Switch Rating Fuse Class Fuse Clip Rating 50V 600V Cat No. Fuse Cover with Door H, J, R Non-Fusible 00A 00A ---- ---- 495-N68➀ H, J, R Non-Fusible 00A 00A ---- ---- 495-N63➁ ➀ Switch with right hand mechanism ➁ Switch with left hand mechanism 405-55-0 () Printed in U.S.A.