Siemens AG Modern design and easy handling for charging at home or in the semi-public area

Similar documents
How do you take the first step towards an energy efficient future?

Standard-compliant components for commercial photovoltaic applications

SIMOTICS GP Frame sizes 80 and 90

LIIKENNEVIRTA LTD GENERAL TERMS AND CONDITIONS FOR THE CHARGING SERVICE

Take explosion protection measures, reduce the risks

SAKHALIN ENERGY INVESTMENT COMPANY LTD. INVITATION TO TENDER

ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions

Welcome to the world of electromobility!

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

SIGENTICS HV Series S-modyn

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

RSPO PalmTrace - Book and Claim Terms and Conditions

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164

SIMOTICS FD looks different, offers more

5SM6 AFD Units Advanced Preventative Fire Protection

Drive technology for the chemical industry. chemical INDUSTRY

Product guide. Enclosed NEMA starters. Answers for industry.

Vertabelo Academy. Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Purpose. Background. Exclusions

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

Benefits, typical uses

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Volkswagen Marine Boat Engines

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Efficiency classes of single-speed three-phase, cage-induction motors

Section 1 Scope of application

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Technical Support for Electric Vehicle Charging Requirements in the Building Code that are in effect January 1, 2018

Faster project implementation. Earlier return on invest. SIMOTICS HV M shaft height 450 to 800: the modular motor concept up to 19 MW

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

ASK SAM! SIMPLE, SAFE AND COMPLIANT WITH CALIBRATION REGULATIONS.

8 Cylinder TDI. Volkswagen Marine. Boat Engines

Solid Tantalum Surface Mount, TANTAMOUNT, Molded Case, Very Low DCL

Dublin Airport Chauffeur Code of Conduct Dublin Airport Chauffeurs Code of Conduct. Dublin Airport Parking

Instruction Manual. Ex-Time 40 / 50

Witham (Specialist vehicles) Ltd For sale by Tender - 13th September pm Direct From UK Ministry of Defence

Rig Master Power by Mobile Thermo Systems Inc.

Drive System Application

Electric Networks/Ina Lehto Updated Original 12/2011

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

Wind Power Inverter WINDY BOY 5000A/6000A

Telhio Credit Union Account to Account (A2A) Transfer Service User Agreement

NI 9251 with mini XLR

Toro Sprayer Calibration Tool

KeContact P20. User manual

COUNTY ROAD COMMISSION RULES FOR THE MOVEMENT OF OVERSIZE OR OVERWEIGHT VEHICLES AND LOADS

INDUSTRIAL HAUL AGREEMENT

Design Guide for Integration of Fixed-Mount Circuit Breakers

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

ELECTRICITY SERVICE PRICE LIST

Control Circuit Protection

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Always the right gear unit. The widest gear unit range worldwide. ... to large ones. From small. FLENDER gear units. Answers for industry.

EXTRA ORDINARY 16 AASHAADHA, 1937(S) BIHAR ELECTRICITY REGULATORY COMMISSION

The optimum geared motor for every motion control application. Brochure April 2007

Installation Manual & Warranty

Compact, flexible, highest availability. H-compact PLUS

BETA Switching Switches and Light Indicators

Siemens AG SIMOTICS T-1FW3 Torque Motors. The Powerful Torque Motors. Edition February Brochure. siemens.

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Exchange of rollers from the XTS-Mover

User Agreement For Transfer To/From Other Financial Institution (A2A) Transfer Service

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

ECO Plus - Warranty documents. Axle systems with air suspension

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement

PVI 60KW, PVI 82KW, PVI 95KW

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

EU-Mexico Free Trade Agreement EU TEXTUAL PROPOSAL

Case No IV/M HAGEMEYER / ABB ASEA SKANDIA. REGULATION (EEC) No 4064/89 MERGER PROCEDURE. Article 6(1)(b) NON-OPPOSITION Date: 007/10/1997

LAW OF THE REPUBLIC OF KAZAKHSTAN # 588-II DATED JULY 9, 2004 ON THE ELECTRIC POWER INDUSTRY

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

Modifications to the German Road Traffic Act (StVG)

PEAK LOAD CAPACITY AGREEMENT XXXX/2017. Customer Oy. and. Finextra Oy

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

SIRIUS 3TH4 contactor relays with 8 and 10 contacts. Electrical Components for the Railway Industry

Product Environmental Declaration according to ISO Type II siemens.com/mobility

c-go 24V/6A 24V/8A 24V/12A

Drive System Application

PV inverter SUNNY MINI CENTRAL 7000HV

(Liability of producers and importer for spent batteries and accumulators etc.)

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Description AX5806. List of permissible motors. Version: Date:

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

DHL ecommerce BATTERY SHIPPING POLICY

Model Legislation for Autonomous Vehicles (2018)

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Getting Started Guide Racing Supplement EXTREME CONTENTS INSIDE

Three-Phase Induction Motors SIMOTICS HV Series H-compact

Transcription:

s Drivergy WB140A charging unit Modern design and easy handling for charging at home or in the semi-public area Easy charging at home WB140A charging unit: Modern, functional design and easy handling combine to create an optimized solution for use in garages and workshops, as well as in semipublic parking lots. Additionally, the type of protection IP44 facilitates applications outdoors, e.g. in carports. Comfortable handling The charging process commences as soon as the charging coupler is connected to the electric vehicle. The integrated delay function supports setting a charging delay in two-hour increments (2/4/6/8 hours) up to a max. of 8 hours. This allows charging with PV current or utilizing off-peak tariffs. LEDs display the current status. The additional LEDs at the top right and left of the housing indicate the actual charge status and are easily visible from a distance: ready-to-charge / charging / fault. Easy installation The system-tested and CE-compliant charging unit can be quickly and easily connected to a 230/400 V grid. At the time of installation the installer can limit the maximum current to match the existing conditions of the electrical system. A separate mounting bracket facilitates wall mounting. The charging cable is fixed to the charging unit and can be wrapped around the housing for easy storage. Highlights 7 The delay function allows low-cost charging 7 LEDs that are easily visible at a distance signal the current operational status 7 The installer can limit the maximum current for simple adaptation to the existing electrical system 7 Separate mounting bracket for easy installation Answers for infrastructure and cities.

Monitoring Devices Charging Infrastructure for Electric Vehicles 5TT3 charging units Overview IEC/EN 61851 describes the safety requirements that must be met by conductive charging systems for electric vehicles. Standard-compliant AC charging in operational mode 3 requires a charging station with safety-relevant functions. The WB140A charging units are based on monitoring electronics developed by experienced engineers and system-tested in combination with the charging cable and coupler as well as the intuitive operator control unit. The WB140A complies with the revised standard IEC 62196-2 and comes with the new charging coupler Type 2 Generation 2. This ensures compatibility with future generations of electric vehicles. Application The WB140A charging unit is a system-tested, CE-compliant unit for charging electric vehicles in operational mode 3 in accordance with IEC/EN 61851 and IEC/EN 62196 for indoor and outdoor use, e.g. carports, garages, workshops, underground parking garages or multistory parking decks. Flexible wiring options The WB140A features rear and bottom fed wiring ports. Delay button A simple, multi-setting delay timer has been built into the WB140A charging unit to allow for user control. With the press of a button, the user can delay charging up to 8 hours from the time of plug-in. The charging process starts automatically after the time delay has elapsed. Charging status indicator Large LEDs indicate the current operational status at a distance. The following states are displayed: "Ready-to-charge" / "Charging" / "Fault". Adjustment switch for optimum performance Installing electric vehicle chargers in older buildings can be a challenge. With the WB140A charging unit the maximum value for the charging current can be adjusted to match facility capability. Incremental settings range from a maximum current of 32/20 A down to 10 A. Customer-focused design An integrated holster keeps dust and dirt away from the charging coupler. The Type 2 Gen 2 connector is ergonomically designed for user comfort. The 4 m cord can be stored by wrapping it around the housing. I202_02436 I202_02435 Frontal and lateral view Mounting bracket 2 Siemens 2012

Monitoring Devices Charging Infrastructure for Electric Vehicles 5TT3 charging units Technical specifications WB140A charging units with charging cable and charging coupler 5TT3 201-1KK25 5TT3 201-1KK27 5TT3 201-1KK37 Standards IEC/EN 61851-1; IEC/EN 61851-22; IEC/EN 62196-1; IEC 62196-2 Operational voltage V AC 230 230/400 Rated frequency Hz 50/60 Rated current max. 20 A 32 A Type of protection IP44 Safety class I Touch protection in acc. w. DIN EN 50274 Finger and back-of-hand safe Ambient conditions Ambient temperature C -25... +40 Storage temperature C -30... +60 Relative humidity % 95 Installation location Suitable for indoor and outdoor use Mains connection bottom/rear Connection cross-sections mm 2 1.50... 6 2.5... 10 Housing Material Plastic Color RAL 7035 (light gray) Dimensions (H x W x D) mm 420 x 420 x 483 Weight kg 5.5 5.8 6.6 Charging tap-off Charging mode in acc. w. IEC 61851-1 3 Connection type in acc. w. IEC 62192 C, charging cable with charging coupler Type 2 Gen 2 Operator controls PAUSE (STOP/START charging process) DELAY 2, 4, 6, 8 hours (charging process delay) Displays LED, green, orange, red, blue Length of charging cable m 4 Selection and ordering data Rated current Charging coupler Type Rated operational voltage DT Order No. Price per PU PU (UNIT, SET, M) PS*/ P. unit PG Weight per PU approx. A V AC kg WB140A charging units with charging cable and charging coupler 20 2 Gen 2 230 5TT3 201-1KK25 1 1 unit 050 5.500 20 2 Gen 2 230/400 5TT3 201-1KK27 1 1 unit 050 5.800 32 2 Gen 2 230/400 5TT3 201-1KK37 1 1 unit 050 6.600 Further information Order number index incl. export markings Order No. Export markings ECCN AL 5TT3 5TT3 201-1KK25 EAR99H N 5TT3 201-1KK27 EAR99H N 5TT3 201-1KK37 EAR99H N * You can order this quantity or a multiple thereof. Siemens 2012 3

Appendix Conditions of sale and delivery Overview By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The General Terms of Payment as well as the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry shall apply. For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany shall apply. For customers with a seat or registered office outside of Germany The General Terms of Payment as well as the General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany shall apply. For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany shall apply. General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given - these are subject to change without prior notice. The prices are in (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products. You will find an exact explanation of the metal factor, the text of the Comprehensive Terms and Conditions of Sale and Delivery of Siemens AG in the Internet under www.siemens.com/automation/salesmaterial-as/catalog/en /terms_of_trade_en.pdf Export regulations Siemens shall not be obligated to fulfill this agreement if such fulfillment is prevented by any impediments arising out of national or international foreign trade or customs requirements or any embargoes or other sanctions. If Purchaser transfers goods (hardware and/ or software and/ or technology as well as corresponding documentation, regardless of the mode of provision) delivered by Siemens or works and services (including all kinds of technical support) performed by Siemens to a third party worldwide, Purchaser shall comply with all applicable national and international (re-) export control regulations. In any event Purchaser shall comply with the (re-) export control regulations of the Federal Republic of Germany, of the European Union and of the United States of America. If required to conduct export control checks, Purchaser, upon request by Siemens, shall promptly provide Siemens with all information pertaining to particular end customer, destination and intended use of goods, works and services provided by Siemens, as well as any export control restrictions existing. Purchaser shall indemnify and hold harmless Siemens from and against any claim, proceeding, action, fine, loss, cost and damages arising out of or relating to any noncompliance with export control regulations by Purchaser, and Purchaser shall compensate Siemens for all losses and expenses resulting thereof, unless such noncompliance was not caused by fault of the Purchaser. This provision does not imply a change in burden of proof. The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL ECCN Number of the German Export List Products marked other than N require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an AL not equal to N are subject to European or German export authorization when being exported out of the EU. Export Control Classification Number Products marked other than N are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with ECCN not equal to N are subject to US re-export authorization. Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required due to the final end-use and destination for which the goods are to be used. In addition, you can preview the export designations via our "Industry Mall" online catalog system in the respective product description. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. 4 Siemens 2012

Appendix Notes Siemens 2012 5

Siemens AG Infrastructure & Cities Sector Low and Medium Voltage Division Low Voltage & Products Postfach 10 09 53 93009 REGENSBURG GERMANY www.siemens.com/sentron Subject to change without notice Order No.: E86060-K8210-E360-A2-7600 MP.R3.LP.0000.00.3.09 / Dispo 18301 PI 1012 1. SB 6 En / valid until 09/13 Printed in Germany The information provided in this product catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.