DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG

Similar documents
DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

ONE STAGE GAS BURNERS RDBS SERIES

IBExU Institut für Sicherheitstechnik GmbH

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

STAINLESS STEEL CONDENSING GENERATOR RANGE RATED. MODEL Heat thermal input 65,5. 62,0 Heat output (80 C/60 C) 14,0

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

Boiler Management Unit (BMU)

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

Installation- and maintenance instruction BENTOFLEX ST 108 PL

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Installation- and maintenance instruction BENTOFLEX ST120KAV

Spare parts list SI RSF 22/04/

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

0063 Page 1 of 2 CERTIFICATE 88735/01. Appendix no.: 1 Dated: July 2015 Examination report(s): /2. List of available types,

DATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

Installation- and maintenance instruction ST120 S75/21

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

TECHNICAL INFORMATION

Oil - kerosene burner

Light oil - kerosene burner

Solenoid actuator MB 7 and butterfly valves BVHM

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

ECONOMATIC REX/REXF REX/REXF DUAL STR

Innovo Condensing high efficiency water heater

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

AXIAL FANS Axis / Tubo OPERATION MANUAL

available in battery up to 4 units for a total of 560 kw

DATA SHEET. Model: TG4 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

VE4000 & VE5000 SERIES

Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

SPARE PARTS CATALOGUE

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

European Fire Pump Listing

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

Gas burners EK EVO 6 EK EVO 7

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

EU Mutual Recognition Technical Requirements

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Certificate of constancy of performance

Installation- and maintenance instruction BENTOFLEX ST133KA/K

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RESOLUTION MEPC.181(59) Adopted on 17 July GUIDELINES FOR PORT STATE CONTROL UNDER THE REVISED MARPOL ANNEX VI

SPARE PARTS CATALOGUE

SGS Australia Pty Ltd

VALUPAK. Packaged gas burners

PAB Atex-certified centrifugal pumps

Installation- and maintenance instruction B20KA/K

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

SPARE PARTS CATALOGUE

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

The Baxi GA Combi & System Boiler Range

Opening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.

C e r t i f i c a t e

UD and UC Gear pump unit

Differential Pressure Sensors

G72x Series Direct Spark Ignition Controls

Prüffeld der Schaltwerke

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

PORTABLE GENERATING SETS POWER RANGE 2 15 KVA 2017

Amendment to Test Report

portable generating sets power range 2 15 kva 2015

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Installation- and maintenance instruction B80-2/3

Amendment to Test Report

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

The bereal Project - Scientific Highlights

System 6. Solenoid Coils Armature Assemblies Valve Systems

Spare parts list (2015/10) Gö. GB172-30/35/42 i

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Rexroth IndraDyn E. Standard Motors MOT-FC for Frequency Converter Operation. Project planning manual R Edition 03

Test report. About the effect of Lambda System Cleaning Products. No

Made in Germany. Portable generators. power 2-15 kva

Jiangsu Zeversolar New Energy CO.LTD Building 9 No.198, Xiangyang Road, Suzhou, PEOPLE'S RE- PUBLIC OF CHINA

Doing more for clean environment and energy saving

Certificate of Conformity self-generation unit

Technical Data. Dimensions

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

23-Jul-14. VCA job number: CSQ Date: 23 July Dear Sirs,

PFP The compact lightweight

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

Transcription:

Page: 2 of 10 Report No. R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants 7 Remarks 8 Electrical data 8 Installation species 8 Registration-requiring components 9 Supports 9 Inspection results 10 Pages Annex 1 Annex 2 measured values used measured instrument

Page: 3 of 10 Report No. test model / type: 1x ZWE24-5 MFK 24 kw OF-type TTnr. 7716010255 1x ZWE24-5 MFA 24 kw RSF-type TTnr. 7716010253 1x ZWE28-5 MFA 28 kw RSF-type TTnr. 7716010254 Applicable examinations: CE-type examination test report B 06/11/0891-1 from 26.04.2007 explanations / characteristics: The appliances are also marked as Brands and Types: Brand Product name Types Specials Efficiency Class Junkers Ceraclass comfort ZWE 24-5 MFA. ZWE 24-5 MFK. ZWE 28-5 MFA.. RSF System OF System RSF System 2 star BOSCH BW 24C comfort ZWE 24-5 MFA. ZWE 24-5 MFK. RSF System OF System 2 star BW 28C comfort ZWE 28-5 MFA.. RSF System elm leblanc Junkers acleis Ceraclass comfort NGVM 24-4 HN (ZWE 24-5 MFA E) RSF System 3 star NGVM 28-4 HN (ZWE 28-5 MFA E) RSF System NGLM 24-4 HN (ZWE 24-5 MFK) OF System 2 star ZWE 24-5 MFA E. RSF System 3 star ZWE 28-5 MFA E RSF System ZWE 24-5 MFK OF System 2 star The gas appliances ZWE 24-5 MFA /MFK and ZWE 28-5 MFA are already certified by DVGW under CE-PIN CE-0085BS0043 and CE-0085BS0044. This test report is to confirm new countries of destination and product names of used brands. It could be reached 3star efficiency by optimization of fan speed of MFA-types. These gas appliances will be presented as MFA E-types. Already certified types were produced furthermore.

Report No. DVGW Prüflaboratorium Gas Page: 4 of 10 Countries / categories / inlet pressures country abbreviation category inlet pressure mbar natural gas LPG special notes Flue system Netherland NL II 2L3B/P 25 30 RSF: 80/110; 80/80; OF: 130 Hungary HU II 2HS3B/P 25 30, 50 RSF: 60/100; 80/80; OF: 130 Italy IT II 2H3+ 20 28-30/37 RSF: 60/100; 80/80; OF: 130 Italy IT II 2H3B/P 20 30 RSF: 60/100; 80/80; OF: 130 All already certified countries are valid furthermore!

Report No. DVGW Prüflaboratorium Gas Page: 5 of 10 Technical data for the enterprise with G 25.1; 25 mbar: (HU) Type Setting Nominal heat input (H i ) Ø Nozzle Nominal heat output (H i ) Burner Pressure G 25.1 mm mbar 80/60 Efficiency 1) 60/40 55/45 full 26,7 kw 24,0 kw 12,1 90,6 ZWE24-5 MFA reduced 18 x 1,15 9,4 kw 7,3 kw 1,0 93,2 full 26,7 kw 24,0 kw 12,1 90,2 ZWE24-5 MFK reduced 18 x 1,20 8,4 kw 7,3 kw 1,0 87,4 full 31,3 kw 28,1 kw 15,2 91,1 ZWE28-5 MFA reduced 18 x 1,20 10,6 kw 8,6 kw 1,0 90,9 Technical data for the enterprise with G 25; 25 mbar: (NL) Type Setting Nominal heat input (H i ) Ø Nozzle Nominal heat output (H i ) Burner Pressure Efficiency G 25 mm mbar 80/60 60/40 55/45 full 26,7 kw 18 x 1,10 24,0 kw 14,5 ZWE24-5 MFA reduced 8,4 kw 7,3 kw 1,4 full 26,7 kw 18 x 1,20 24,0 kw 12,0 ZWE24-5 MFK reduced 8,4 kw 7,3 kw 1,2 full 31,3 kw 18 x 1,25 28,1 kw 11,8 ZWE28-5 MFA reduced 12 kw 10,5 kw 1,0 Technical data for the enterprise with G 20; 20 mbar: (IT) Type Setting Nominal heat input (H i ) Ø Nozzle Nominal heat output (H i ) Burner Pressure Efficiency G 20 mm mbar 80/60 60/40 55/45 full 25,9 kw 18 x 1,00 24,0 kw 12,6 93,0 ZWE24-5 MFA E reduced 8,1 kw 7,3 kw 0,8 90,8 full 26,7 kw 18 x 1,10 24,0 kw 10,7 89,8 ZWE24-5 MFK reduced 12,3 kw 11 kw 2,5 89,0 full 30,2 kw 18 x 1,05 28,1 kw 15,6 92,9 ZWE28-5 MFA E reduced 9,5 kw 8,6 kw 0,8 90,6 1) average boiler temperature 70 C or 60 C measurement uncertainty +/- 1,5

Page: 6 of 10 Report No.: Flue Type 60/100 Concentric Horizontal Gropalli HU Appl. Capacity 500 501-1000 1001-2000 2001-3000 3001-4000 ZWE24-5 MFA 78 80 85 90-4000 ZWE28-5 MFA 81 81 85 85-4000 Flue Type 60/100 Concentric Vertical - Gropalli Appl. Capacity 1500 1501-3500 3501-6000 6001-8000 Flue Type 80/80 Twin Pipe Pancake connection ZWE24-5 MFA ZWE28-5 MFA 200 0 2001-10000 10001-20000 20001-30000 82 85 90 - Flue Type 80/110 Concentric Horizontal NL 500 501-1000 1001-2000 2001-3000 3001-5000 30000 ZWE24-5 MFA 82 85 85 85-5000 ZWE28-5 MFA 80 85 85 90-5000 Flue Type 80/110 Concentric Vertical NL 1500 1501-3500 3501-6000 6001-10000 ZWE24-5 MFA 82 85 85-10000 ZWE28-5 MFA 85 90 90-10000

Page: 7 of 10 Report No.: Flue Type 80/80 Twin Pipe Pancake connection - NL ZWE24-5 MFA ZWE28-5 MFA 2000 2001-10000 10001-20000 20001-30000 82 85 90-30000 Flue Type 60/100 Concentric Horizontal Gropalli IT 500 501-1000 1001-2000 2001-4000 4001-5000 ZWE24-5 MFA E 76 78 78 85-5000 ZWE28-5 MFA E 72 85 85 - NA 4000 Flue Type 60/100 Concentric Vertical Gropalli IT 1500 1501-3500 3501-6000 6001-8000 ZWE24-5 MFA E 76 78 78 85 8000 ZWE28-5 MFA E 80 85 85-8000 Flue Type 80/80 Twin Pipe Pancake connection - IT 2000 2001-10000 10001-20000 20001-30000 ZWE24-5 MFA E 76 76 78 85 30000 ZWE28-5 MFA E 80 80 85-30000 Execution variants / Explanations: ZWE combi boiler (central heating CH and domestic hot water DHW) 24(28) Nominal heat output 5 design generation MFK open flue system (B-category) MFA room sealed flue system (C and B category) MFK E RSF-version with 3star-efficiency

Page: 8 of 10 Report No.: Remarks: maximum water pressure CH: 3 bar Pressure class: 2 maximum outlet temperature CH: 82 C minimum outlet temperature CH: 45 C NOx class: efficiencies class: standard efficiency boiler acc. EU 92/42/EEC: 4 for MFA-type 3 for MFK-type ** for MFK and MFA-types *** for MFA E-types domestic hot water comfort class: ** diameter of the flue gas system: 60/100 mm or 80/110 mm (concentric system) or 80/80 mm (parallel system) for MFA-type, company Gropalli, 130 mm (connector for MFK-type) Electrical Data: 230 V, 50 Hz, 160 W degree of protection: IP X4D Installation species: B 11, B 11BS for specification MFK B 22, B 32, C 12(x),C 32(x),C 42(x),C 52,C 82(x) for specification MFA B 22, B 32, C 12(x),C 32(x),C 42(x),C 52,C 82(x) for specification MFA E

Page: 9 of 10 Report No. Registration-requiring components: Component Type Manufacturer Registration-Number Gas Valve 845 SIGMA SIT la precisa S.p.A. CE-0063AS4831 Automatic burner control systems for gas burner Pressure sensing devices for gas burners and gas burning appliances HT III BBT Thermotechnik CE-0085BP5501 DDS 605... Huba Control AG CE-0085AP0974 CH STB 161 4 Inter Control GmbH & Co KG VDE 4868-4510-0071 Flue gas STB 1NT...-... Texas Instruments Inc. VDE 4464.3-4510-0008 Supports: no

Page: 10 of 10 Report Nr.: Inspection results: The examination of the gas appliances in the context of the safety-relevant approvals resulted in that a safety operation with natural gas and LPG for the listed countries is inconsideration of the requirements is ensured under fulfillment of listed restrictions. The safety and automatic control correspond to the regulations and function duly. The pollutant emission is lower than the permissible limiting values. This test report is written for the certification by DVGW (German association for gas and water e.v., Josef Wirmer Strasse 1 3, D 53123 Bonn) as confirmation of the conformity. Publication and passing on to third are permissible only in complete, unabridged form. Publication or spreading of excerpts, summaries, valuations or other working on and transformations, in particular for advertisement purposes, is permissible only with previous written agreement of the DBI-GTI ggmbh Freiberg. The publication of the page 1 (first page) is permitted. The inspection results represented in this report exclusively refer to the test samples. Evaluations of the results regarding the fulfilment of the essential safety requirements of the European directive 90/396/EEC in the context of this report take place informatively for the client. It represent no evaluation in the sense of the conformity procedure for the type approval certificate, which is reserved only by the certification body.