CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Similar documents
CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

CP (Vdc) CP (Milliamp) CP (Slidewire)

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

MA-5200 Series MA-5300 Series

CP CP

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

TS , -850 Series TS , -850 Series TS-57031, TS

MF4E MF4E

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

AV-401. Application. Features. Applicable Literature. Pneumatic Actuator Valve Linkage Kit General Instructions

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

TS Series TS Series

M100F Incremental Motor Actuator R81F Interface Board

IMP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning. Hyciraulic Actuator General Instructions SIEBE

MK-6600 Series, MK-6800 Series, and MK-6911

AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

MC-351, 421, 431, MC-4311

MA40-704X Series MA41-707X Series MA41-715X Series

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

MS40-717X Series. Application. Features. DuraDrive Series Spring Return Proportional Actuators General Instructions

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

TK-6024, TK-6124, TK-8024, TK-8124

AV-611. Application. Applicable Literature. Schneider Electric DuraDrive Globe Valve Linkage General Instructions

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

2211 Series. Application. Features. One-Pipe Pneumatic Room Thermostats General Instructions SPECIFICATIONS

VA-4233-GGx Series Electric Valve Actuators

MS Series MS Series MS Series

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

Damper Actuator Installation

MF Series MS Series

MF Series MF Series MF Series

TAC DuraDrive Product Guide Direct Coupled Actuators

MA/F/S 4D-xxxx-xxx Two Position, Floating and Proportional Series SmartX Actuators Rotary Overshaft Actuators

ComfortPoint Programmable Lon, VAV/Unitary Controllers

MS41-634X Series. Features. SmartX Actuators Non-Spring Return Proportional General Instructions

System 350 S350P Proportional Plus Integral Temperature Stage Module

Non-Spring Return EconoDrive Floating Actuator

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Series 71, 72, and 76 Modutrol IV Motors

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

VA-715x Electric Valve Actuator

Series EA High Torque Actuators with Integrated Controller

MX4X-6XXX-20X Series MX4X-7XXX-20X Series

35 and 70 lb-in. Non-Spring Return Direct Coupled Actuators ML6161, ML7161, ML6174, ML7174

Application. Features

Invensys Energy Solutions 1354 Clifford Avenue (Zip 61111) P.O. Box 2940 Loves Park, IL United States of America

Powers TM Controls EA 338 Electronic Actuator

Installation Instructions

Installation Instructions

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9216 Series Electric Spring Return Actuators

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

AV-608 Linkage Adapter Kit

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Series 41 and 81 Modutrol IV Motors

System 350 P352AB Electronic Pressure Control Series

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

MAx1-720x Two Position Series MFx Floating Series MSx Proportional Series

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Q7130A, Q7230A, Q7330A Modutrol IV Interface Modules

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Flowrite 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

VA-4233-AGx Series Electric Valve Actuators

MA40-704X Series, MA4X-707X Series, MA4X-715X Series DuraDrive Series Spring Return Two-Position Actuators General Instructions

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

M436A/M836A,B Damper Motors

MF /MS Series

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators


DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

SAX Electronic Valve Actuator

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

ML6420, ML7420 Non-Spring Return Electric Linear Valve Actuators

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

VA-715x Electric Valve Actuator

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Powers TM Controls SW 141 Differential Static Airflow Switches

Transcription:

CP-80-xxx Series to 5 Vdc Input Electronic General Instructions Application The CP-80-xxx Series electronic actuator drive is designed to process a variable to 5 Vdc signal from a controller to provide proportional control of an electric gear train actuator. Features Mounts directly onto Schneider Electric proportional, electric, gear train actuators. Fixed to 5 Vdc operating range., 0, and 0 Vac models available. Color-coded pigtail leads. Applicable Literature Environmental Controls Cross-Reference Guide, F-68 Environmental Controls Reference Manual, F-68 Environmental Controls Application Manual, F-5 Pneumatic Products Catalog, F-78 MP-xx Series, MP-xx Series, MP-xxx Series, and MP-xxx Series Reversible and Proportional Electric s General Instructions, F-579 Printed in U.S.A. / Copyright 0 Schneider Electric All Rights Reserved. F-90-8

SPECIFICATIONS Inputs Control Signal: Range, to 5 Vdc, nonadjustable. Span, Refer to Table-. Start Point, Refer to Table-. Power Requirements: Refer to Table-. Power Supplies: Refer to Table-. Outputs Connections: Color-coded pigtail leads. Mounting: Directly to an actuator. The upright position is preferred, but other positions are acceptable. Case: Black Phenolic - IDI -0 5VA - RoHS Compliant. Environment Ambient Temperature Limits: Shipping & Storage, -0 to 60 F (-0 to 7 C). Operating, -0 to 0 F (-0 to 60 C). Humidity: 5 to 95% relative humidity, non-condensing. Locations: NEMA Type. Agency Listings US Standard UL 87: Underwriters Laboratories (File #E99 Category XAPX, Temperature Indicating and Regulating Equipment). Canadian Standard C. No. : Underwriters Laboratories (File #E99 Category XAPX7, Temperature Indicating and Regulating Equipment). Table- Specifications. Power Requirement Part Number Vac,.8 VA 50/60 Hz (+0/-5%) CP-80-0 CP-80-0 0 CP-80-0 0 Power Supply b 0 Vdc, 50 ma regulated and filtered Start Point of Adjustable a from to Vdc input Factory-set at 6 Vdc a Remove the company logo, then turn the start point potentiometer CW to increase the start point. b The power supply must not be connected to the +0 (red) of other supplies. Span Fixed at Vdc for full actuator stroke Table- Typical s. Power Torque Stroke Spring Internal Series 60 Hz Amp Lb-in. N-m Degrees Return Transformer a MP--500. 50 5.6 80 No MP-6.5 50 5.6 80 CW No MP-7.5 50 5.6 80 CCW No MP-8.5 0.9 80 No MP-50-500 0 0.5 50 5.6 80 Yes MP-65 0 0.5 50 5.6 80 CW Yes MP-75 0 0.5 50 5.6 80 CCW Yes MP-8 0 0.5 0.9 90 Yes MP-85 0 0.5 0.9 80 Yes MP-86 0 0.5 0.9 80 Yes MP-95 0 0.95 50 50.8 80 Yes a Units with a - suffix, e.g. MP-xxxx-xxx--x, include a built-in transformer (used for Barber-Colman Microtherm or with AE-50) with secondary leads wired externally to terminals seven and eight of the actuator. Red ( Vac) to terminal eight and Blue ( Vac) to terminal seven. When these actuators are used with controllers other than Barber-Colman Microtherm or AE-50, disconnect the Red and Blue leads and tape off. Note: Models prior to - suffix had transformer wired directly to potentiometer. To disconnect the transformer, remove the back plate of the actuator, disconnect and tape the transformer leads. Copyright 0 Schneider Electric All Rights Reserved. F-90-8

ACCESSORIES None TYPICAL APPLICATIONS (wiring diagrams) TOOLS Appropriate screwdriver TOOL-0 Calibration kit for System 8000 TM products. Refer to Figure- for a service application wiring diagram showing the connections between a CP-80-xxx series drive and an MP-xx, MP-xx or MP-xx series actuator. CP-80-XXX Yellow Blue Red Brown/White Brown Brown/Black Red/Black Blue/Black Yellow/Black Green/Yellow MP-XX, MP-XX, MP-XX Series Yellow (OP) Wire Nuts Blue (COM) Red (+0) Terminals x 7 8 00 Ohm Slidewire Limit Switches Typical Controller TP-80 CP-80 Shading Windings Field Winding Part Number Vac Color CP-80-0 Black/Blue CP-80-0 0 White CP-80-0 0 White/Black Black L (H) L (G) Power For actuator with internal transformers. Disconnect red and blue leads from actuator terminals 7 and 8 and tape off. Diagram shown: increasing input causes CW actuator rotation. All references to the direction of rotation are determined by looking at the actuator output shaft. For CCW rotation with an increasing input signal, reverse the wires to terminals 7 & 8 and &. Connect Green/Yellow ground wire from CP actuator drive to case ground screw. Figure- Service Application Wiring Diagram. INSTALLATION Inspection Requirements Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products. Tools (not provided): Appropriate screwdriver Digital Volt-ohm Meter (DVM) Training: Installer must be a qualified, experienced technician Other accessories as appropriate Wiring diagrams F-90-8 Copyright 0 Schneider Electric All Rights Reserved.

Warning: Electrical shock hazard! Disconnect power before installation to prevent electrical shock or equipment damage. Make all connections in accordance with the electrical wiring diagram and in accordance with national and local electrical codes. Use copper conductors that are suitable for 75 C. Caution: Do not exceed the ratings of the device(s). Static charges produce voltages high enough to damage the electronic components. Follow static electricity precautions when installing or servicing the device(s). Discharge any static electricity you may have accumulated. Discharge static electricity by touching a known, securely grounded object. Avoid locations where excessive oil, dust, moisture, corrosive fumes or vibration, or an explosive atmosphere is present. Mounting Upright mounting of the drive is preferred, but other positions are acceptable. Mount the drive onto an actuator as follows:. Insert the drive s two /" conduit connectors into the two /" knockouts provided on the actuator casing. Refer to Figure-, Figure-, and Figure-5. Left-Side Mounting (Optional) Right-Side Mounting (Typical) Figure- Mounting Position of on. Caution: The power wires must always be inserted directly into the power wiring compartment of the actuator. If the optional mounting position for the drive (refer to Figure-) is used, it is required that the wires of the drive are routed to exit through its other conduit bushing.. Secure the drive to the actuator with the two locknuts provided. Refer to Figure-. Copyright 0 Schneider Electric All Rights Reserved. F-90-8

Power Wiring Compartment L (H) L (G) Barrier To Controller L (H) 5 L (G) 6 8 x 7 Location of Start Point Adjustment Potentiometer Low Voltage Wiring Compartment Top view. Remove green wire from terminal X. Right-side mounting is shown. Connect Green/Yellow ground wire from CP actuator drive to case ground screw. Figure- / Wiring and Mounting Arrangement. WIRING Power Wiring All the power to the drive is supplied by the electric actuator onto which the drive is mounted. Refer to Figure-. Refer to Table- for power wire selection. Table- Power Wire Selection. Voltage Vac 0 0 Wire Size AWG Maximum Run (each run has two wires) ft (m) 0 () 5 (76) 00 (60) All the applicable actuators have a barrier that separates the power wiring compartment from the low voltage wiring compartment. The power wiring for the Vac actuators may be per Class circuit requirements if the auxiliary switch (terminals one, five, and six) is Vac, or is not used. The power wiring must be per Class circuit requirements if the actuator is line voltage or if the auxiliary switch is powered by line voltage. The connections to the low voltage wiring compartment may be per Class circuit requirements. Input Wiring The drive s two input wires, which must be connected to the controller, are color-coded blue (COM) and yellow (OP). Refer to Figure-. Use 8 gage, three-conductor, twisted leads (part number W-0) for runs of up to 000 ft. (05 m) between the controller and the actuator. Use larger-sized leads for longer runs. Caution: Use 8 gage, shielded, twisted cable when it is necessary to install the signal leads in the same conduit with the power wiring, or when high RFI/EMI generating devices are near. Terminate the shielding on the signal leads at one end only, using the controller s COM (negative) terminal. Grounding the shielding at both ends could create a potential difference in the shielding, which may affect the signal voltage carried by the leads. F-90-8 Copyright 0 Schneider Electric All Rights Reserved. 5

Green / Yellow Yellow / Black Blue / Black Red / Black Brown Red Red (+0) Yellow Yellow (OP) Blue Blue (COM) 5 6 7 X 8 H G Brown / White Brown / Black Black CP-80-XXX Typical Controllers TP-80 CP-80 AC Supply CP-80-0 can be used with the following electric actuators: MP-6, 7, 8, 8, -500 and 97. CP-80-0 can be used with the following electric actuators: MP-65, 75, 8, 85, 86, 95, and 50-500. CP-80-0 can be used with 0 Vac electric actuators. (Available as a standard option.) rotates clockwise on increase in input signal. To rotate actuator counterclockwise on an increase in input signal, reverse blue/black and red/black leads and reverse brown/black and brown/white leads. Vac s Only. 6 5 Part Number Vac Color CP-80-0 Black/Blue CP-80-0 0 White CP-80-0 0 White/Black 5 6 7 These terminals are marked L & L on 0V and 0V actuators. 0V and 0V actuators must not have a built-in transformer, or if a built-in transformer is present, remove red and blue leads from terminals 7 and 8, and tape off. External green jumper from X to case ground (and G to case ground, for Vac) on MP-XXXX-XXX-X- models only. Connect green/yellow ground wire from CP actuator drive to case ground screw. Figure- Installation Wiring Diagram. ADJUSTMENTS Start Point Adjustment The start point of these actuators is factory-set to 6 Vdc and is field-adjustable from to Vdc. If a start point other than 6 Vdc is required, proceed as follows:. Peel back the Schneider Electric label from the drive, to expose the start point adjustment potentiometer. Refer to Figure-.. Disconnect the red, yellow, and blue leads of the drive from the controller.. Connect the leads of TOOL-0 to the like-colored leads of the drive.. Connect a DVM to the yellow (OP) and blue (COM) leads of the drive. 5. Adjust TOOL-0 until the DVM reading equals the required start point voltage ( to Vdc). 6. Adjust the actuator start point, using a small, single-slotted screwdriver, so that the actuator shaft just begins to rotate when the desired voltage is applied. 7. Press the label back onto the drive. CHECKOUT After the entire system has been installed and the actuator has been powered up, the following checks can be made for proper system operation. Positioning with Controller If the sensed media is within the controller s setpoint range, the actuator can be positioned by adjusting the controller setpoint up and down. Check for correct operation of the actuator (valve or damper) while it is being stroked. 6 Copyright 0 Schneider Electric All Rights Reserved. F-90-8

Go, No Go Test Manual Positioning. Disconnect the field wiring from the red, yellow, and blue leads of the drive.. Apply power to the actuator.. Short the yellow and red leads of the drive. The actuator should rotate CW to its limit, unless it is rewired to rotate CCW on an increase in input signal. Disconnect the short between the yellow and red leads.. Short the yellow and blue leads of the drive. The actuator should rotate CCW to its limit, unless it is rewired to rotate CW on an increase in input signal. Disconnect the short between the yellow and blue leads. 5. If the assembled actuator and drive passes steps and, they are functioning correctly. If the assembly does not pass these steps, proceed to the next step. 6. Unhook the drive leads from actuator terminals x,, and. 7. Short actuator terminals x and two. The actuator should rotate CW to its limit. Disconnect the short. The actuator should stop rotation. 8. Short actuator terminals x and three. The actuator should rotate CCW to its limit. Disconnect the short. The actuator should stop rotation. 9. If the actuator passes steps 7 and 8, it is functioning correctly. If the actuator does not pass these steps, the drive may still be functional but the actuator must be replaced.. Apply power to the actuator.. Disconnect the actuator s control leads from the controller.. Attach the leads from the manual positioner (TOOL-0) to the like-colored leads on the drive.. Manually position the actuator by turning the knob of the manual positioner. 5. Check for proper operation of the valve or damper as the actuator is operated. 6. Remove power from the actuator. 7. Reconnect the actuator wires to the controller. F-90-8 Copyright 0 Schneider Electric All Rights Reserved. 7

MAINTENANCE The drive requires no maintenance. Regular maintenance of the total system is recommended to assure sustained, optimum performance. FIELD REPAIR None. Replace an inoperative drive with a functional unit. DIMENSIONAL DATA " (0mm) -7/8" (8mm) -/" (8mm) -/" (6mm) " (5mm) /" Conduit Thread " (0mm) Figure-5 Mounting Dimensions of CP-80-xxx Series Electronic. Copyright 0, Schneider Electric All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. F-90-8 Schneider Electric 5 Clifford Avenue P.O. Box 90 Loves Park, IL 6-90 www.schneider-electric.com/buildings