LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Similar documents
AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS

Automatic capacitor banks

INSTRUCTION MANUAL (M A)

MODVAR Low voltage reactive power compensation modules Installation manual

LV CAPACITOR BANKS WITH STATIC SWITCHING EMK SERIES

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

LV Capacitor CLMD03 Power Module Instruction manual

High Reliable Components for Power Factor Correction and Power Quality

Operation of a CDP in SPLIT-PHASE installations

R.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :

EMPAC Metal enclosed capacitor bank for wind applications

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Three Phase Capacitors KNK

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Power System Solutions (PSS)

High Reliable Components for Power Factor Correction and Power Quality

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

C1000 Series Automatic Cap Bank

CP Automatic capacitor bank

Power Factor Correction Capacitors in sheet steel cases

ORION PLUS three-phase kVA

New range of reclosing systems

HARMONIC FILTER REACTOR

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Electric Switchboards

Solutions for Power factor Correction at Medium Voltage

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Power capacitors Low Voltage

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Power factor correction and harmonic filtering. Power capacitors Low Voltage

Power factor solutions for electric switchboards

DYNACOMP. The top-class reactive power compensator

FINHRM FINHRM5 FINHRMA FINHRMAC

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Transforming Energy.. For Advanced Technology

Automatic COSYS PFC. Automatic power factor correction system NEW

PhiCap Capacitors for Power Factor Correction

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

LV Capacitor CLMD Reliability for Power Factor Correction

Power Factor Correction Capacitors Type LKT

Power Factor Correction

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Thermal-magnetic Miniature Circuit Breaker 4230-T...

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

MATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Power Factor Correction Equipment

Horizontal Circuit Switchers

Impact of Plug-in Electric Vehicles on the Supply Grid

Horizontal Circuit Switchers

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Power Factor Correction

High Frequency SineWave Guardian TM

Technical Data Sheets

Medium Voltage Capacitors

Industrial PFC UPS System

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Technical Data Sheets

CLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation

Unified requirements for systems with voltages above 1 kv up to 15 kv

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

ahead of time Voltage Stabilisers

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

LV Capacitor Bank APC

LV Capacitor Bank APC

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Installation Manual for DC Injection Brake Units

POWER CAPACITORS. Cylindrical capacitor standard duty

Motor-drive mechanism, type BUL. Technical guide

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Trifazni kondenzatorji KNK

Qingdao Zener Electric Co., Ltd

MV capacitors banks and accessories

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Smart earth leakage protection

AIR CORE REACTORS. Phoenix Electric Corporation

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

Multi-purpose percentage restraint differential protection

Electronic Ballast EVG 2000-T

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Low Voltage Power Factor Corrections

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

LINE CONDITIONERS USER'S GUIDE

Film Capacitors Power Factor Correction

TECHNICAL DATA SHEET KVA UPS Systemss

UPS Multi Sentry 10-20kVA

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Application manual Dry type power factor correction capacitors

Solutions for Electrical energy efficiency

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

Capacitor Switching Contactors Type K3...-A, K3...-K

Experience and History

Transcription:

LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A.

------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2 INTRODUCTION. 3 3 OPERATING PRINCIPLE. 3 3.1 HOW TO SELECT A LCL FILTER? 3 4 TECHNICAL CHARACTERISTICS 4 4.1 GENERAL. 4 4.2 REACTORS 4 4.3 CAPACITORS 4 4.4 STANDARD TYPES ( THREE PHASE 50HZ ) 5 4.5 OVERCOMPENSATION RELAY OPTION 5 4.6 DIMENSIONS AND WEIGHT 6 4.7 SCHEMATICS 8 5 INSTALLATION AND START-UP. 9 5.1 LOCATION. 9 5.2 INITIAL CHECKS (PRE-INSTALLATION, SWITCH THE POWER OFF). 9 5.3 CONNECTING THE POWER CIRCUIT. (SEE SCHEMATICS IN FIG 3) 9 5.4 CONNECTING THE OPERATING CIRCUIT (ONLY IN CASE OF OVERCOMPENSATION PROTECTION) 9 5.5 START UP. 9 6 CHECK POINTS. 9 7 PERIODICAL SERVICING. 10 8 SAFETY. 10 9 TECHNICAL SERVICE AND GUARANTEE. 10 2

------ LCL filters: Instructions Manual ----- Page 3 1 CHECKS ON RECEIPT OF THE EQUIPMENT. Before installing and handling the equipment check that: 1) The equipment has not been damaged during delivery. 2) The equipment supplied is suitable for your requirements and is the type you ordered. 3) The operating voltage of the equipment supplied is suitable for your requirements. 4) Manuals for the equipment and for the regulator are supplied with the capacitor bank. 5) If any problem is noticed, please contact the commercial service department of CIRCUTOR S.A. 2 INTRODUCTION. LCL filters are specially designed to reduce harmonics of current absorbed by power converters, with a rectifier input stage. (Frequency converters for motors, UPS, etc.). Mainly, they are made of a parallel-series combination of reactors and capacitors adapted to reduce the THD(I) of rectifiers. They are specially designed to reduce the THD(I) to values of approximately 8%, in order to comply with IEC-61000-3.4 and IEEE-519 standards. 3 OPERATING PRINCIPLE. The structure of LCL filters is as shown in the schematics below. The basic filter is designed with L1,L2, L3 and C. In some cases reactor L4, is already placed in front of the converter. In such case L2 may be unnecessary MAINS IMPEDANCE L1 LCL FILTER L2 L4 CONVERTER L3 M 3 C Fig. 1.- LCL filters Structure 3.1 How to select a LCL filter? LCL filters must be selected according to the current absorbed by the converter. In case of converters with very low power rating, a unique LCL filter may be used to supply several converters, but only in case the all start and stop at the same time. If several converters starting and stopping separately are supplied by the same LCL filter, the system is not effective on filtering the harmonics. In such case an individual LCL should be used for each converter. ATTENTION: LCL filters may produce cos overcompensation in case that the converter is absorbing a current much lower than the rated current of the filter itself. This can be avoided by disconnecting the parallel LC circuit when the current falls below a certain adjustable limit. An optional protection circuit, consisting of a CMM-96-MD and a contactor, may be added to perform this function, if requested in the order. 3

------ LCL filters: Instructions Manual ----- Page 4 WARNING!!!: Due to the LCL filter performance mode, it is quite likely to find elevate harmonic distortion levels of voltage at the input of the speed drive (downstream to the filter output reactor (L2)). This voltage distortion should cause no malfunction of the speed drive to be filtered, but it is very much recommendable, in case that this power drive is taken the auxiliary voltage supply of the control system from the input of the drive, to take this auxiliary supply from the LCL input, that is, upstream to the filter input reactor (L1). Fig. 2.a. Mains supply without LCL filter Fig. 2.b. Mains supply without LCL filter 4 TECHNICAL CHARACTERISTICS 4.1 General. Standard voltage (phase to phase) 400V (Others on request) Frequency 50Hz for types LCL-35-xx or 60 Hz for types LCL-36-xx Rated load current See table of types Rated filtering current See table of types Parallel filter protection Fuses NH or NZ type depending on size Residual THD Aprox. 8% Voltage drop at rated current < 2% Standards EN 60439, EN 60831 ; EN-50081-1, EN-50081-2, class A Ambient temperature Ambient : 40ºC Relative Humidity 80% 4.2 Reactors Core / Coil High permeability metal sheet / Aluminium Isolation voltage 2kV Tolerance in L value <3% Saturation L=5% 1,6 of rated current Maximum ambient temperature 60ºC Internal temperature at I rated <110ºC Protection thermostat trip 90 ºC Total maximum overload (n.in) 2 25% Permanent 20% Transient (1 min) 2 I rated 4.3 Capacitors Dielectric Polypropylene Self-healing 4

------ LCL filters: Instructions Manual ----- Page 5 Working voltage < 1,15 of rated U Transient overload (10s) 1000 V Isolation voltage against earth 3 kv Operating temperature -25 / +50 ºC Losses 0,5W/kvar 4.4 Standard Types ( Three phase 50Hz ) TYPE (1) (3) RATED VOLTAGE RATED LOAD CURRENT (A RMS ) RATED FILTERING CURRENT (A RMS ) (2) CABINET MODEL LOSSES W (V ) LC L35-9A-400 400/415 9 3,6 A 55 LC L35-12A-400 400/415 12 4,8 A 73 LC L35-16A-400 400/415 16 6,4 A 97 LC L35-22A-400 400/415 22 8,8 A 134 LC L35-32A-400 400/415 32 12,8 A 194 LC L35-40A-400 400/415 40 16 A 243 LC L35-47A-400 400/415 47 18,8 B 286 LC L35-54A-400 400/415 54 21,6 B 328 LC L35-64A-400 400/415 64 25,6 B 389 LC L35-76A-400 400/415 76 30,4 B 462 LC L35-90A-400 400/415 90 36 B 547 LC L35-110A-400 400/415 110 44 C 668 LC L35-150A-400 400/415 150 60 C 911 LC L35-180A-400 400/415 180 72 C 1094 LC L35-220A-400 400/415 220 88 D 1337 LC L35-260A-400 400/415 260 104 D 1580 LC L35-320A-400 400/415 320 128 D 1944 LC L35-400A-400 400/415 400 160 D 2430 REMARKS 1) If protection against power factor overcompensation is desired, specify in the order 2) Load is supposed to be a three phase 6 pulse rectifier, with dominant harmonics of order 5 and 7 3) For 60 Hz types, specify LCL36 instead of LCL35 4.5 Overcompensation relay option Measuring instrument Contactor Current transformer CMM-96-MD suitable for the filter power TP type 5

------ LCL filters: Instructions Manual ----- Page 6 4.6 Dimensions A - Sizes from 9 to 40 A IP21 B - Sizes from 47 to 90 A IP21 C Sizes from 110 to 180 A IP21 6

------ LCL filters: Instructions Manual ----- Page 7 D Sizes from 220 to 400 A IP21 7

------ LCL filters: Instructions Manual ----- Page 8 4.7 SCHEMATICS L1 Mains Switch must be placed upstream CT U1 L1 L2 U2 L2 V1 V2 L3 W1 W2 N MAINS SIDE N S1 A2 S1 A1 CMM 96-MD S2 18 15 A1 A2 F1 LOAD SIDE S2 L3 C Fig. 3.- Schematic drawing 8

------ LCL filters: Instructions Manual ----- Page 9 5 INSTALLATION AND START-UP. 5.1 Location. The equipment must be located indoors, away from heat sources and adequately ventilated. 5.2 Initial checks (pre-installation, switch the power OFF). A main switch must be provided upstream to cut the supply of the filter. Check that the nominal voltage of the equipment, shown on the technical information label is the same as the nominal voltage between phases for the system to which it will be connected. Connect the protective conductor: the cabinet must be earthed through the earthing terminal. Check and tighten terminals that may have come loose during delivery. 5.3 Connecting the power circuit. (see schematics in Fig 3) Connect the power terminals (U1, V1, W1) to input cables coming from the mains side and (U2, V2, W2) to the cables going to the converter side. WARNING! If holes need to be drilled in the casing to feed cables through, take care to avoid shavings falling onto the contactors. 5.4 Connecting the operating circuit (Only in case of overcompensation protection) The current transformer is installed at a point upstream of the filter. Usually in L1 incoming line. Connect the CMM-96-MD and set the device to the desired limit of reactive current. (See CMM- 96-MD manual) 5.5 Start up. Check again the control and power circuit connections. Switch the main switch ON 6 Check points. For optimum operation of the filter, the following points must be considered: Voltage: The operating voltage must not exceed the nominal voltage; Operating in overload conditions considerably reduces the life of the capacitors. Current: The absorbed current for each capacitor, must not exceed 1.3 times its nominal current. Whenever the current absorbed by the capacitors is higher than the nominal current may be due to excess of harmonics or a voltage higher than the nominal voltage. Both situations are harmful for the capacitors. In this event, the bank must be disconnected and CIRCUTOR s technical department must be contacted to ascertain the best way to solve the problem. 9

------ LCL filters: Instructions Manual ----- Page 10 7 PERIODICAL SERVICING. Maintenance should be carried out in accordance to the safety procedures detailed in section 8. LCL filters require minimal maintenance, but it is recommended that the following procedures be undertaken: During the first month of operation. Visually inspect the capacitors. Examine the protective fuses. Control the temperature. Control the service voltage (especially under low load conditions). Retighten terminals and connections. Annually. Check the capacitor's nominal current. Clean the terminals and isolators on the capacitors. Check that the terminal connections are tightened. Check the condition of the contacts on the contactor if there is overcompensation protection. 8 SAFETY. Before handling any device in the filter disconnect the supply upstream. The filter does not have any main switch. Switch must be placed at the line head. Even when the bank is disconnected, there still may be voltage in the capacitors. Therefore, after having removed the supply voltage, wait for 3 minutes and then short circuit them and earth the terminals or output cables on each capacitor. 9 TECHNICAL SERVICE AND GUARANTEE. CIRCUTOR guarantees its products against manufacturing faults for one year from the date of delivery. The guarantee does not cover protective devices (fuses) nor operating devices subject to natural wear and tear. This guarantee becomes void in the event of improper handling or disregard of the handling conditions. CIRCUTOR has its CONSULTANCY AND TECHNICAL ASSISTANCE service at your disposal. CIRCUTOR, S.A. Vial Sant Jordi, s/n - 08232 Viladecavalls - (08007 Barcelona) Spain Tel.: +34 93 745 29 00 Fax: +34 93 745 29 14 E-mail: central@circutor.es http:// www.circutor.com 10