NDJ Series New DAIPACK

Similar documents
Internet For latest information, PDF catalogs and operation manuals

NDR Series Rotor Pack

N UNIT EQUIPMENT N UNIT EQUIPMENT N-1

Internet For latest information, PDF catalogs and operation manuals

Pressure Control Valves

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

Type C2 Seat Type Solenoid Pilot Valve

INDEX INVERTER HYDRAULIC UNIT. 7 MPa. 10 MPa. 16 MPa. 21 MPa. List of Hybrid Hydraulic Unit Models. P.3 to 4. List of Super Unit Models Nomenclature

HYDRAULIC POWER UNITS ENERGY-SAVING HYDRAULIC POWER UNIT-TOYOPAC ECO K 2. Features. Description of the model designation.

ECORICH. Debut of NEW ECORICH. New Products. New Launch with Full Model Change!

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

MOTOR-PUMPS PAL PUMPS. M Series Electric Motors. M Series Electric Motors 212. PAL PUMPS & M Series Electric Motors. Maximum Operating Pressure MPa

Solenoid Pilot Operated Directional Control Valve

A fusion of hydraulic and motor/inverter technologies Drastically improved functions on top of the energy saving features of the IPM motor

Reducing Valve/Reducing Valve with Check Valve

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

UNLOADING RELIEF VALVES

Solenoid Pilot Operated Proportional Directional Control Valve

Pilot Operated Check Valves

PZH Series High-Pressure Variable Volume Piston Pump

Hybrid Hydraulic System ECORICH EHU /EHU EHU /EHU SETUP MANUAL

A Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.

AR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74%

Compact Variable Pump Unit. NSP Series. Energy saving type friendly to the earth. Powerful & Compact

HYDRAULIC UNIT. NSPi-SERIES CELEBRATE THE POLE POSITION TOP ECO LEADER. Energy-efficient with 69 % energy savings

High Pressure, High Flow Rate Modular Valves

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01

" " Series Variable Displacement Piston Pumps

Direct Operated Type Solenoid Operated Proportional Throttle Valve

PISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps.

"A" Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps

OUTLINE DIMENSIONS HIGH PRESSURE PUMP HDF 40/40-8 1/6. High pressure pump HDF 40/40-8. HYDRAULIC FLOW l/min, max. 10. HYDRAULIC PRESSURE bar, max.

VDS Series Small Variable Volume Vane Pump

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

VDS Series Small Variable Volume Vane Pump

Direct Operated Type Solenoid Operated Proportional Throttle Valve

Standard Hydraulic Power Units Power Packages

TM Series Positioning Motors

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3

MC-104CER MC-285CRM-E MC-305CRM-E

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

PUMP SCPD 56/26 DIN BY-PASS

FLOW CONTROL VALVES F CONTROL VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.] Maximum flow rate L/min. Page

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

VDR22 Design Series Variable Volume Vane Pump

A Series Variable Displacement Piston Pumps

PRESSURE REDUCING AND RELIEVING VALVES

Series Variable Displacement Piston Pump

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

"A" Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type

10 SERIES MODULAR VALVES. Pub. EC-1405

" " Series Variable Displacement Piston Pumps

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

VDR13 Design Series Variable Volume Vane Pump

Instruction for RBP250-3 and RBP300-3

PRESSURE REDUCING AND RELIEVING VALVES

ISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090

Electric Hoist. LE 250 (kg) D 230 V 60 m. 6 m. 60 m. 6 m

AKZ8 Series. DAIKIN Oil Cooling Unit ( OILCON ) Instruction Manual. Circulating type. Models. Proper use results in power saving PIM00116C CONTENTS

A resiliant clamping solution for modern machine tool applcations.

ARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev

Mechanical Booster Pump PRC-A Series, PMB-B, C (M) Series

VARIABLE DISPLACEMENT PISTON PUMPS

Gas Pressure Governors

Internal Gear Pumps Installation Manual

3.6 to 125.9cm 3 /rev 30MPa

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Specifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator

IPH Series Double IP Pump

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART COMPACT A 204 PERFORMANCE CHART COMPACT B 205

100 to 400 MPa Series

Pub.EC Series

HORIZONTAL MULTI STAGE PUMPS

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Principle of operation

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4

INSTRUCTION MANUAL OIL SEALED ROTARY VACUUM PUMP MODEL PKS-016 PKS-030 PKS-070

PUMPS AND MOTORS VARIABLE-DISPLACEMENT VANE PUMP HVP VB1 A 10. Features. Cautions on use. Description of the model designation

GMP-Type. Key Features: Integrated Motor-Pump Units

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Manifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications

LPCD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

OPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

DAIKIN INDUSTRIES, LTD.

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

06 SERIES MODULAR VALVES. Pub. EC-1404

Operating Instructions

Transcription:

DJ Series ew DIPK omenclature DJ - - 0-4 6 7 Model o. DJ: ew DIPK Pump capacity 8: V 8 used ( 8 cm /rev) : V used (4.8 cm /rev) Pressure adjustment range 9: 0.8 to. MPa {8 to kgf/cm } : 0.8 to 7 MPa {8 to 70 kgf/cm } 6 7 Design o. (The design o. is subject to change.) Option code o designation: Standard (floor mounted type) L: Wall mounted type Specifications Pump capacity cm /rev Output kw (umber of poles: 4) Tank capacity L Maximum operating pressure MPa {kgf/cm } Tank capacity 0: 0 L : L : 0.7 kw, 4-pole :. kw, 4-pole Pressure adjustment range MPa {kgf/cm } Discharge rate L/min * Pressure at shipment MPa {kgf/cm } Mass (Fluid excluded) kg Model code 0 Hz 60 Hz DJ 89-0-0 (-L) 0.7 0. {} 0.8 to. {8 to }. {} 8 6 to 7 to 4 DJ 8--0 (-L) 7 {70} 0.8 to 7 {8 to 70} 7 {70} 4. DJ9--0 (-L) 4.8. {} 0.8 to. {8 to } to 0 6 to. {} 0 Pressure - Flow rate characteristics 8 series DJ89-0-0 (-L) DJ8--0 (-L) Features Refer to Page -8 for details of V series piston pumps incorporated into these units. ote: *. The discharge rate is set to the maximum value before shipment Low noise The tank contains the pump and motor inside and functions itself as noise insulation panels to trap noise internally. Low oil temperature rise hollow tank with a large heat exchange area and forced cooling of the tank's internal panels and the pump surfaces with a motor cooling fan suppresses fluid temperature rise. ompact design Reduced installation space with compact design series DJ9--0 (-L) 4 Pump discharge rate (L/min) 0 0.4 kw 0. kw. kw.0 kw 0.7 kw Pump discharge rate (L/min) 0 0. kw.0 kw 0 0 4 6 7 Pressure (MPa) { 0 kgf/cm } 0 0. Pressure (MPa) { 0 kgf/cm } -7

Paint color Tank: Ivory white (Munsell code Y7./) Pump: lack Handling Hydraulic fluid, ambient environment Use a petroleum-based hydraulic fluid equivalent to ISO VG to 46. Use of hydraulic fluids other than the petroleum-based type (e.g. hydrous/synthetic) is prohibited. Operate the unit in an environment where both the following conditions are satisfied: viscosity range from to 400 mm /s {cst} and oil temperature from 0 to 60. e sure to maintain the water content in the hydraulic fluid at 0.% maximum by volume. ontamination of the hydraulic fluid causes device trouble and reduces the service life, so pay due attention to controlling contamination and ensure that it goes no higher than S contamination class 0. Use the unit indoors under the following conditions. mbient temperature: 0 to, mbient humidity: 0 to 90%RH (with no condensation) t start Fill the pump case with hydraulic fluid through the filler port before starting trial operation, after replacing the pump, or after stopping the unit for months or longer. Use the same hydraulic fluid as for the hydraulic circuit. DJ8 DJ9 Pump case fi lling volume cm 00 00 fter checking that all hydraulic circuits and electrical circuits are ready for operation, set the hydraulic circuit at the load side in the no-load status or connect an unloading circuit before starting the pump. When the pump is driven for the first time, turn the power switch to the motor on and off a few times to let the air out of the piping and then run it continuously at full speed. oise may be observed until the air has been completely removed but this is not abnormal. Electric wiring onnect the power cable matching the phases at the pump motor and power supply sides as shown below. Motor side U V W R S T Power supply side heck that the pressure at the delivery side rises at the pressure gauge. If wires are connected with the wrong phase order, the motor and pump rotate in the reverse direction and no fluid is discharged. If fluid is not discharged within minutes after turning the power on, the phase order may be incorrect. In this case, switch the wires for two phases among the three. e sure to connect the ground terminal. Install a no-fuse breaker and an earth leakage breaker on the main power supply. The electrical ratings are as shown in the table below. Model code Output kw (umber of poles: 4) Rated current () 00 V (0 Hz) 00 V (60 Hz) 0 V (60 Hz) DJ 89-0-0 (-L) 0.7.7.4. DJ 8--0 (-L) DJ9--0 (-L). 6.8 6. 6. ir intake/exhaust Do not place any obstacles to motor cooling fan air intake and exhaust within a distance of 00 mm from intake and exhaust vent of the motor cooling fan. Install the unit at a location with good air flow so that heated air can be vented. Transportation Use eye bolts for hoisting to transport the unit. Installation The unit is a stationary type. Fix it with bolts on a level location that is free of vibration. -8

External dimension diagram DJ- - -0 φ wiring port (for user) P Rc⅜ (Plugged) Terminal cover P Rc⅜ (Plugged) K 0. 4 attery charge mark nameplate. D J E rimp-style terminal (M4 round) U, V, W G Earth terminal (M) F T Rp "L" (Plugged) T Rp "M" (Plugged) Hoisting prohibited nameplate Oil filler port on the case Fill with hydraulic fluid before starting trial operation Hydraulic circuit diagram T T P P 4 Rp "L" Rp "M" Rc⅜ Rc⅜ 6 M Rc⅜ 4 6 H H (Height of port P) Yellow line Red line Pressure adjusting screw (Socket for hex key: 6.) (lockwise: pressure rise) Hexagonal flat lock nut: 7 Discharge rate adjusting screw (Socket for hex key: ) (lockwise: flow rate decrease) Hexagonal flat lock nut: 0 Wiring nameplate Unit nameplate Eyebolt for hoisting (M8) (opposite side) aution nameplate Oil level H4 H Part o. ame Oil tank Suction strainer Oil level gauge 4 Motor pump Oil filler port-cum-air breather 6 Pressure gauge Tank drain port Rc⅜ (Plugged) Suction air -M8 (t four sides) Suction air () D E F G H H H H4 J K L M Optional wall mounted type (-L) installation dimension diagram Tank fluid volume Yellow line Red line Mass (Fluid excluded) DJ 89-0-0 90 7 00 0 99 0 4 407 4 09 ⅜ ½ 0 L 7. L kg DJ 8--0 0 00 0 7 478 4 406 09 ⅜ ½ 4 kg L L DJ9--0 0 00 0 7 70 496 469 406 ½ ¾ 0 kg D D D E DJ89-0-0-L 70 40 40 00 80 DJ --0-L 400 70 80 0 40 0 80 6-φ (E) -9

Options (separately available parts) Option table Part o. ame -series block set Piping set locking block set Detail of accessories Order code Model Quantity For DJ89-0 For DJ8- For DJ9- -series block O-ring (P0, class ) : M8 70 P-TJSET-0 Hoisting bolt M8 High-pressure plug Rc⅜ Installation guide Piping (rubber hose with braid) Plastic joint/rubber band pcs. each P-DJ89PIPE-0 P-DJ8PIPE-0 P-DJ9PIPE-0 Piping guide locking block O-ring (P9, class ) 4 P-S0SET-0 (M ) 4 Each option can be installed using just hex keys, an adjustable wrench, and screw drivers. For guidance on installation, refer to the installation (piping) guide provided with the option or the instruction manual for the DJ series. Hydraulic circuit Option installation guide 0 series modular stack valve (M, 4 pcs.) locking block (M8 70, pcs.) O-ring, 4 pcs. (P9, class ) -series block set High-pressure plug (Rc⅜) Piping set O-ring, pc. (P0, class ) -0

-series block (P-TJSET-0) External dimension diagrams 9 0 64 0. 80 49 6 -φ9 8. 0 4 -φ4 44 4-Rc⅜ 8 6 φ4 0 4 08 O-ring ( P0) (ccessories) T P -Rc⅜ M8, depth 6 (for hoisting bolt) 4 8 -Rc⅜ (High-pressure plug fitted) ccessories: Mounting bolts: M8 70 hexagon socket head cap bolt, pcs. O-ring: JIS 40 class P0, pc. Hoisting bolt: M8 eye bolt, pcs. -