Low-Voltage Motors N-compact Standardline Operation on supply system

Similar documents
Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

1LG0 Low-voltage Motors

New Generation 1LE1/1PC1

SINAMICS GM150 IGCT version

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Non-Standard Motors Overview. Low-Voltage. IEC Squirrel-Cage Motors Frame sizes 315 to 450 Power range 160 kw to 1250 kw

Active Interface Module Active Line Module chassis format, air-cooled

Non-standard motors frame size 315 and above

Synchronous motors. Main spindle motors for SINAMICS S120 1FE1 standard type built-in motors Water cooling. 6/86 Siemens NC /2008

SINGLE PHASE TEFC CAGE MOTORS

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry.

Preferred Series 215 kw to 1500 kw. Catalog DA /2000

DC motors. G-motion. CTi Automation - Phone: Fax: Web:

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

champion series motors

Asynchronous motors. 5 Asynchronous motors 5/2 Type overview and rated data 5/4 Technical definitions 5/4 Encoder systems

System configuration SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Asynchronous motors. 7/2 Main spindle motors for SIMODRIVE 611 7/2 Introduction

Aluminium Frame Motors Improved Efficiency EFF2

SINAMICS G110 Inverter chassis units 0.12 kw to 3 kw

3RG4 BERO Inductive Proximity Switches

AC motors. 3/2 Overview

Open continuous current (DC) motors MS 1 - MS 2. General information

Motors. IE changeover. IEC Squirrel-Cage Motors. Frame sizes 63 to 450 Power range 0.09 to 1250 kw Price List D 81.

SINAMICS DCM DC Converter, Control Module

SIMOTICS S-1FT7 Servomotors. The Compact Servomotors for High-Performance Motion Control Applications. Motors. Edition April 2017.

SIMOTICS GP Frame sizes 80 and 90

ASM. Asynchronous Spindle. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

3RW Soft Starters. General data. 6/4 Siemens LV

PLS Open Drip Proof three-phase asynchronous motors. General information

Standard motors up to frame size 315 L

Demag KB conical-rotor brake motors. Drives with unique principle

3RT14 Contactors with 3 Main Contacts

BETA Switching Switches and Light Indicators

Series E4F E5F

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

3 - Protection components Motor circuit-breakers

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

SINAMICS S120 drive system

Order No. of the options EMC filter Class A

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

ROBICON W120 enclosed drive

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Low-Voltage Motors. Catalog M

Permanent-magnet synchronous motors

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

water-cooled motor / generator with up to 13 kw continuous power

Standardmotoren Standard motors

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

LSES high efficiency three-phase asynchronous motors. General information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

SIRIUS Soft Starters Introduction

: B3; B5; B14; B34; B35; V1

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

For Operation in the Control Cabinet 3RW Soft Starters

Low Voltage Induction Motors

Protection Equipment

Compact, flexible, highest availability.

Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC.

SENTRON Switching and Protection Devices Switch Disconnectors

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Asynchronous generators

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME

SINAMICS S120 drive system

Datasheet. Pitch Motor PMSM SP260B8

LSES high efficiency three-phase asynchronous motors General information

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

Motors. IE changeover. IEC Squirrel-Cage Motors

Datasheet. Pitch Motor PMSM SP190C8

Flexible Couplings N-EUPEX Series

Industrial Performance Motors. New Aluminum and Cast Iron Motors. Flexibility

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

Datasheet. Pitch Motor PMSM SP190F8

Energy Saving Three Phase Motors

SIMOTICS Low-Voltage Motors

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

General Purpose Cast Iron Motors

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Explosion and flame-proof cast iron electric motors

M3000 Steel Motors. ABB LV Motors M3000 Range

H:\SC218\17_Ersatzteile\Spare Parts SC 218.doc

Variable speed asynchronous motors with FCPL brake LSMV FCPL. General information

SINAMICS S120 Cabinet Modules Application Shaft Generator Drive

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

More freedom - lower cost

Compact, dynamic and rugged

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Metric Efficient Line Cast-iron IEC Motors

POWERTRAIN SOLUTIONS FOR ELECTRIFIED TRUCKS AND BUSES

Flexible Couplings RUPEX Series

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Transcription:

Low-Voltage Motors N-compact Standardline Operation on supply system 2 2/2 Overview 2/2 Benefits 2/2 Technical specifications 2/2 Selection and Ordering Data 2/ Options 2/ Dimensional drawings 2/4 More information 2/4 Power cables Siemens D.1 2005

Operation on supply system 2 Overview The N-compact series sets the modern worldwide standard for large three-phase low-voltage motors. Many details of the motors design make them durable and so robust that they are always capable of withstanding extreme stresses. In terms of technical design, the N-compact Standardline series is identical to the familiar 1LA N-compact motors which are described in Catalog M 11 (Order No. E00-K111-A101-A- 00). Standardline is intentionally designed to focus the N-compact series on meeting the requirements of drives for pumps, fans and compressors: Power range 250 to 500 kw Supply voltages 400 V, 500 V and 0 V at a frequency of 50 Hz 4-pole Type of construction IM B Benefits Standardization has made it possible to further optimize order handling and production processes. Benefits to the customer: Significant reduction in delivery time to only 4 weeks Attractive price State-of-the-art technology and quality which is already in use worldwide Technical specifications Further information about general technical data and the design and construction of the N-compact motor series can be found in Catalog M 11 (Order No. E00-K111-A101-A-00) and in the electronic Catalog CA 01 on CD-ROM (Order No. E00- D4001-A110-C-00). Selection and Ordering Data Type IM B, degree of protection IP55, temperature class F, utilization in accordance with temperature class B Rated power Order No. + order codes for further options Operating values at rated output Rated speed Efficiency h with 4/4 load /4 load Ordering example: Low-voltage motor N-compact Standardline basic version 400 Vd, 50 Hz, 1500 rpm, 4-pole, 55 kw with option K45: Anti-condensation heating for 20 V 1LA5-4AB0-Z +B20+K45 Power factor cos j Rated current at 400 V Rated torque Starting torque Starting current Stalling torque with direct starting as multiple of rated torque current torque Torque class kw rpm % % A Nm CL kgm 2 AC 400 V, 50 Hz 1500 rpm, 4-pole 250 1LA15-4AB0-Z + B20 14.0.0 0. 425 100 1..5 2. 1. 15 1LA1-4AB0-Z + B20 14.. 0. 540 2020 2.0. 2. 1 4.4 55 1LA5-4AB0-Z + B20 14.. 0. 10 220 2.1.5 2. 1.1 400 1LA55-4AB0-Z + B20 14.4.4 0. 0 250 2.1.5 2. 1. 500 1LA5-4AB0-Z + B20 14.. 0. 50 210 2.1.5 2.4 1.5 Voltage distinctive number: 400 Vd/0 V* 500 Vd 5 Moment of inertia J 2/2 Siemens D.1 2005

Operation on supply system Options Option description Order code Comment Standardline design B20 Always state Motor temperature sensing by KTY 4-10 temperature sensor A2 Motor temperature sensing by PT100 resistance thermometers A1 2 screw-in PT100 resistance thermometers in basic circuit for rollingcontact A2 bearings Terminal box on RHS (view onto DE) K0 Standard Terminal box on LHS (view onto DE) K10 Anti-condensation heating for 20 V K45 Auxiliary terminal box 1XB 020 L Auxiliary terminal box 1XB 01 L Next larger terminal box 1XB1 21 M5 The next larger size of terminal box is recommended when cables with cross sections >15 mm 2 are installed for motors with shaft height 15. Standard paint finish in other colors Y5 Plain text required 2 Dimensional drawings Design: Type IM B, rolling-contact bearing, degree of protection IP55, cooling method IC 441 D L G_D0_XX_0000 AD H Ø HD E C B BB A AB Type Weight A AB AD B BB C H HD L D E approx. kg mm mm mm mm mm mm mm mm mm mm mm 4-pole 1LA15-4AB.0 100 50 0 50 0 0 10 15 25 1410 5 10 1LA1-4AB.0 1500 50 0 50 0 0 10 15 25 1410 5 10 1LA5-4AB.0 100 0 0 10 00 0 200 55 05 15 5 10 1LA55-4AB.0 2000 0 0 10 00 0 200 55 05 15 5 10 1LA5-4AB.0 2200 0 0 40 00 0 200 55 45 15 5 10 For further information see Catalog M 11 (Order No. E00-K111-A101-A-00). Siemens D.1 2005 2/

Operation on supply system 2 More information Power cables As specified in the table below, parallel feeders are required to connect the motors (see also Catalog M 11 Technical information, Connection, switching, and terminal boxes ): 1LA... Voltage 15 1 5 55 5 400 V k k k k k 500 V k k 2/4 Siemens D.1 2005

Low-Voltage Motors N-compact Standardline /2 Overview /2 Variable-speed drive systems for 400 V and 500 V /2 Benefits /2 Configuration /2 Technical specifications / Selection and Ordering Data / Options / N-compact Standardline motor / Relevant options with SINAMICS G150 /4 Further converter options /5 Dimensional drawings / More information / Power cables Siemens D.1 2005

Overview Variable-speed drive systems for 400 V and 500 V N-compact Standardline motors with SINAMICS G150 frequency converter Configuration With the motor - converter combination (selection and ordering data), the drive can be operated under both low overload and high overload on the basis of the motor drive power (for exceptions, see selection and ordering data, footnotes 4 to ). Note about Low/high overload : The rated output current of the converter equals the maximum permissible current for continuous operation (without overload). If the converter must be capable of handling overload conditions such as breakaway torques or shock loads, a base load current determined according to the duty cycle must be applied to calculate the converter rating. Converter current Short-time current 1.1 x L Rated current (permanent) Base load current L for low overload rated SINAMICS G150 converter cabinet units are designed for use in variable-speed drives in machine construction and plant engineering. They offer a low-cost drive solution which can be flexibly tailored from a wide spectrum of components and options to meet the requirements of individual customers. A detailed description of the SINAMICS G150 converter series can be found in Catalog D 11 (Order No. E00-K5511-A101- A2-00), Part. N-compact Standardline 1LA low-voltage motors and SINAMICS G150 frequency converters combine to make an ideally coordinated system for variable-speed drives specially tailored for operating pumps, fans and compressors (square-law characteristic): Power range 250 to 500 kw Supply voltages 400 V and 500 V, 50 Hz 4-pole motor Motor type IM B L 0 s G_D21_EN_0000 00 s Low overload Converter current 1.5 H rated H 0 s Short-time current Rated current (permanent) Base load current H for high overload 00 s Benefits Benefits to the customer: The complete system can be delivered within 4 weeks. Optimally coordinated drive system Economical drive solution Easy to customize G_D21_EN_0000a High overload The diagrams show the duty cycles for two different conditions, i.e. low overload and high overload, with the resulting base load currents I L and I H. Low overload is defined as a 00 s duty cycle in which the converter may operate at 110% of the base load current I L for 0 s, or at 150% for 10 s (not illustrated). High overload is defined as a 00 s duty cycle in which the converter may operate at 150% of the base load current I H for 0 s, or at 10% for 10 s (not illustrated). The converter may be operated under the appropriate overload conditions only if the base load current is not exceeded within the duty cycle either before or after the overload phase. t Technical specifications Further information about general technical data and the design of the SINAMICS G150 converter series can be found in Catalog D 11 (Order No. E00-K5511-A101-A2-00) and in the electronic Catalog CA 01 on CD-ROM (Order No. E00-D4001- A110-C-00). /2 Siemens D.1 2005

Selection and Ordering Data The following drive systems (motor + converter) are recommended for applications with square-law load torque. N-compact motor SINAMICS G150 converter variant A 2 ) Drive power 1 ) Order No. Rated current Order No. Rated output current kw + order codes for further A for converter options options Order No. with -Z + Order A codes AC 400 V, 50 Hz 1500 rpm, 4-pole 250 1LA15-4PB0-Z + B20 425 SL10-1GE5-0AA0 40 15 1LA1-4PB0-Z + B20 540 SL10-1GE-1AA0 05 55 1LA5-4PB0-Z + B20 10 SL10-1GE-5AA0 45 400 1LA55-4PB0-Z + B20 0 SL10-1GE-5AA0 ) 45 500 1LA5-4PB0-Z + B20 50 SL10-1GE41-0AA0 5 AC 500 V, 50 Hz 1500 rpm, 4-pole 250 1LA15-4PB50-Z + B20 40 SL10-1GF4-1AA0 410 15 1LA1-4PB50-Z + B20 42 SL10-1GF4-AA0 4 ) 45 55 1LA5-4PB50-Z + B20 4 SL10-1GF5-AA0 55 400 1LA55-4PB50-Z + B20 552 SL10-1GF5-4AA0 5 500 1LA5-4PB50-Z + B20 0 SL10-1GF-4AA0 5 ) 5 1) Temperature class F, utilization in accordance with F. The drive output must be reduced by 10% for motors utilized in accordance with temperature class B. 2) For information about SINAMICS G150 design variant A and overload capability, refer to Catalog D 11, Part and section Configuration. ) Converter model SL10-1GE-4AA0 (40 A) must be selected when this drive is operated under high overload conditions 4) Converter model SL10-1GF5-AA0 (55 A) must be selected when this drive is operated under high overload conditions 5) Converter model SL10-1GF-1AA0 (10 A) must be selected when this drive is operated under high overload conditions Ordering example: Low-voltage motor N-compact Standardline basic version AC 400 V, 50 Hz, 1500 rpm, 4-pole, 55 kw with motor option K45: Anti-condensation heating for 20 V Matching converter SINAMICS G150 variant A with converter option K50: Sensor Module Cabinet-Mounted for motor speed acquisition 1LA5-4PB0-Z +B20+K45 SL10-1GE-5AA0-Z +K50 Options N-compact Standardline motor Relevant option with SINAMICS G150 Option description Order code Option description Order code Motor temperature sensing using built-in temperature A2 Standard - sensor KTY 4-10 Motor temperature sensing by means of built-in PT100 G resistance thermometers A1 L Installation of 2 screw-in PT100 resistance thermometers in basic circuit for rolling-contact bearings A2 PT100 evaluation unit for sensors, divided into two groups with factory setting, e.g. with motors, PT100 for the stator windings and two for the motor bearings Built-on pulse encoder LL1 00 220 Built-on pulse encoder HOG 10 D 1024 I H0 H Sensor Module Cabinet-Mounted for motor speed acquisition Terminal box on RHS (view onto DE) K0 Terminal box on LHS (view onto DE) K10 Anti-condensation heating for 20 V K45 Auxiliary terminal box 1XB 020 L Auxiliary terminal box 1XB 01 L Next larger terminal box 1XB1 21 (the next larger size M5 of terminal box is recommended when cables with cross sections >15 mm 2 are installed for motors with shaft height 15) Standard paint finish in other colors (plain text required) Y5 K50 Siemens D.1 2005 /

Further converter options (see Catalog D 11 for detailed descriptions): Option description Order code Input side Line filter for use in the first environment to EN 1 00-, category C2 (TN/TT supplies) L00 Main contactor for currents < 00 A L1 Without line reactor in power range P < 500 kw L22 Line reactor 2% may be required for P > 500 kw L2 EMC shield bus 1 ) (cable connection from below) M0 PE bus 1 ) (cable connection from below) M5 Output side EMC shield bus 1 ) (cable connection from below) M0 PE bus 1 ) (cable connection from below) M5 Motor protection and safety functions EMERGENCY STOP button in the cabinet door L45 EMERGENCY STOP category 0, 20 V AC or 24 V DC, uncontrolled stop L5 EMERGENCY STOP category 1, 20 V AC, controlled stop 2 ) L5 EMERGENCY STOP category 1, 24 V DC, controlled stop 2 ) L0 Thermistor protection unit with PTB approval (alarm) L Thermistor protection unit with PTB approval (switch-off) L4 Insulation monitoring L Additional shock protection M0 Increase in degree of protection IP21 degree of protection M21 IP2 degree of protection M2 IP54 degree of protection M54 Mechanical options Plinth, 100 mm high, RAL 022 M0 Cable connection area, 200 mm high, RAL 05 M0 Power supply connection from above M1 Motor connection from above M Top-mounted crane transport assembly for cabinets M0 Miscellaneous options Customer terminal block extension G1 Cabinet illumination with service socket L50 Anti-condensation heating for cabinet L55 200 kw braking unit L2 Languages Documentation in English/French D5 Documentation in English/Spanish D0 Documentation in English/Italian D0 Rating plate and operator panel in English/French T5 Rating plate and operator panel in English/Spanish T0 Rating plate and operator panel in English/Italian T0 Options specific to chemical industry NAMUR terminal block B00 Protective separation for 24 V supply (PELV) B02 Separate output for external auxiliaries (uncontrolled) B0 1) These options are listed for the input and output options, but are only required once. 2) The drive stop requirements must be taken into account with this option. Additional braking units may be needed. /4 Siemens D.1 2005

Dimensional drawings SINAMICS G150 Converter Cabinet Units - Variant A SL10-1GE5-0AA0 Mains supply and motor terminals at bottom of cabinet (see Catalog D 11 for further connection options) Degrees of protection Minimum ceiling height for wall mounting % Ventilation grille Air outlet zone ( Air inlet zone ) Cables can enter from below within hatched area * Main switch, can be secured by padlock + Power connection, Degrees of protection option - Degrees of protection IP20 IP21 option <M21> IP2 option <M2> IP54 option <M54>. Transport unit Options are shaded grey % % 2 - % 2 - % /, N N % % % % /, N N Siemens D.1 2005 /5

Dimensional drawings SL10-1GE-1AA0, SL10-1GF4-1AA0, SL10-1GF4-AA0, SL10-1GF5-AA0 Degrees of protection Minimum ceiling height for wall mounting % Ventilation grille Air outlet zone ( Air inlet zone ) Cables can enter from below within hatched area * Main switch, can be secured by padlock + Power connection, Degrees of protection option - Degrees of protection IP20 IP21 option <M21> IP2 option <M2> IP54 option <M54>. Transport unit Options are shaded grey % % 2 - % 2-2 - % 2 - % /, N N = % % % % /, N N / Siemens D.1 2005

Dimensional drawings SL10-1GE-5AA0, SL10-1GE-4AA0 Degrees of protection Minimum ceiling height for wall mounting % Ventilation grille Air outlet zone ( Air inlet zone ) Cables can enter from below within hatched area * Main switch, can be secured by padlock + Power connection, Degrees of protection option - Degrees of protection IP20 IP21 option <M21> IP2 option <M2> IP54 option <M54>. Transport unit Options are shaded grey % % 2-2 - 2-2 - % /, N N > % % % % % /, N N Siemens D.1 2005 /

Dimensional drawings SL10-1GE41-0AA0, SL10-1GF-4AA0, SL10-1GF-1AA0 Degrees of protection % Minimum ceiling height for wall mounting % Ventilation grille Air outlet zone ( Air inlet zone ) Cables can enter from below within hatched area * Main switch, can be secured by padlock + Power connection, Degrees of protection option - Degrees of protection IP20 IP21 option <M21> IP2 option <M2> IP54 option <M54>. Transport unit Options are shaded grey % 2-2 - 2-2 - % /, N N > % % % % % /, N N / Siemens D.1 2005

More information Power cables The following table shows the recommended or maximum possible cable connections on the power supply and motor sides. Drive power 1) two-section plate. Power supply connection (converter input) Motor connection (converter output) Cable cross section (to DIN VDE) Cable cross section (to DIN VDE) Motor terminal box Recommended Max. cross section Fixing screw M (no. of holes) Recommended Max. cross section Fixing screw M (no. of holes) Number of terminals Contact screw thread 400 V 500 V 400 V 500 V Max. diameter (sealing area terminal box) kw mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 250 2 x 0 2x5 4 x 240 (2) 2x0 2x5 2x240 (2) M 40... 4 15 2 x 15 2 x 0 4 x 240 (2) 2x15 2x0 2x240 (2) M 40... 4 55 2 x 240 2 x 150 4 x 240 (2) 2x240 2x150 4x240 (2) M1 41... 5 400 2 x 240 2 x 15 4 x 240 (2) 2x240 2x15 4x240 (2) M1 41... 5 500 x 15 2 x 240 x 240 (4) x15 2x240 x240 () M1 40... 5 1 ) The cross section recommendations are based on the fuses specified in Part Accessories of Catalog D11, and on single routing of -core copper cables at 40 C ambient temperature. If these conditions do not apply (cable routing, number of cables and ambient temperature), the planning guide for cable installation in Part 4 Conductor cross sections and terminals in Catalog D11 must be observed. Siemens D.1 2005 /