Bridgelux Gen 7 Vero 13 Array Series. Product Data Sheet DS91

Similar documents
Bridgelux Gen 7 Vero 13 Array. Product Data Sheet DS91

Bridgelux Gen 7 Vero 10 Array Series. Product Data Sheet DS90

Bridgelux Gen 7 Vero 13 Array. Product Data Sheet DS91

Bridgelux Vero. Product Data Sheet DS120. SE 10 Array

Bridgelux Gen 7 Vero 10 Array Series. Product Data Sheet DS90

Bridgelux Gen 7 Vero 13 Array. Product Data Sheet DS91

Bridgelux Gen 7 Vero 13 Array Series. Product Data Sheet DS91

Bridgelux Vero. Product Data Sheet DS120. SE 10 Array Series

Bridgelux Gen 7 Vero 10 Array. Product Data Sheet DS90

Bridgelux Gen 7 Vero 18 Array Series. Product Data Sheet DS92

Bridgelux Gen 7 Vero 18 Array. Product Data Sheet DS92

Product Data Sheet DS123 BXRC-27x10K0 30x10K0 35x10K0 40x10K0 50x10K1 57x10K1 65x10K1

Product Data Sheet DS93 BXRC-27x10K0 30x10K0 35x10K0 40x10K0 50x10K1 57x10K1 65x10K1

Bridgelux Gen 7 V8 Array. Product Data Sheet DS104

Bridgelux Gen. 7 Décor Series Class A LED Array

Bridgelux Vero. Product Data Sheet DS120. SE 10 Array

Bridgelux Gen 7 V10 Array Series. Product Data Sheet DS100

Bridgelux Gen 7 V13 Array Series. Product Data Sheet DS101

Bridgelux Gen 7 Vero 29 Array. Product Data Sheet DS93

Bridgelux Gen 7 Vero 18 Array. Product Data Sheet DS92

Bridgelux Vero 29 Array Series. Product Data Sheet DS93

Bridgelux Vero SE 18 Array Series. Product Data Sheet DS122

Bridgelux Vero SE 29 Array Series. Product Data Sheet DS123

Bridgelux Vero SE 29 Array. Product Data Sheet DS123

Bridgelux Vero SE 18 Array. Product Data Sheet DS122

Bridgelux Gen 7 Vero 29 Array. Product Data Sheet DS93

Bridgelux Vero SE 29 Array Series. Product Data Sheet DS123

Bridgelux Gen 7 V22 Array Series. Product Data Sheet DS103

Bridgelux Vero SE 29 Array. Product Data Sheet DS123

Bridgelux V6 Array. Product Data Sheet DS40. BXRE-27x x x x0400

Bridgelux SMD W 24V

Bridgelux SMD W 24V

Bridgelux RS Array Series

Bridgelux V8 Array Series

Bridgelux Micro SM4. Product Data Sheet DS27 PRELIMINARY, Expires 03/31/12. Introduction. Features. Benefits

Data Sheet. TitanTurbo TM Lamina Lighting Incorporated

LED Modules. Fortimo SLM Premium White 1208 L G6

Experience bright and vivid colors

Experience bright and vivid colors

Experience bright and vivid colors

Lamina Light Engine TYPICAL APPLICATIONS. ATLAS Daylight White

Experience bright and vivid colors

LED Modules. Fortimo SLM

Experience bright and vivid colors

LED Modules. Fortimo SLM

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS

TMU040010ELXXXA TMU040010ELXXXB TMU040010ELXXXC

Chip on Board Line Card. High performance solutions that optimize system designs

TMU040005ELXXXA TMU040005ELXXXB

High-density LED modules that sell

Experience bright and vivid colors

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

A new generation solution for downlight applications

TAT120015AC8XX TJT120015AC8XX

A new generation solution for downlight applications

TET120013RDXX-X1,TEMUNV013RDXX-X1 TKT120013RDXX-X1,TKMUNV013RDXX-X1

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

Fortimo LED Line Gen3

ASMT-QWBG / ASMT-QWBH / ASMT-QWBJ 0.5W Cool White Power PLCC4 Surface Mount LED Datasheet

Experience bright and vivid colors

Associated Rsets. Associated Drivers. XI013C030V048DNM1 0-10V dimming Rset2. XI025C100V045DNM1 0-10V dimming Rset2

LD10 Luminus Light Engine

Experience bright and vivid colors

Lamina Light Engine TYPICAL APPLICATIONS NT-43F0-0424

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

LED Modules. Fortimo SLM. Fortimo LED SLM Gen lm L13

Cree XLamp XP-G2 LEDs

Recommended Land Pattern: [mm]

SMD MID Power LED 67-21S/KK4C-HXXXXXXXX2835Z15/2T/EU

Experience bright and vivid colors

RoHS. Specification. Acrich2 Bulb 120V 8.7W SMJE-2V08W1P3. Drawn Approval Approval. Rev. 01 June

SMD MID Power LED 67-21S/KK4C-HXXXXXXXX2835Z15/2T

LED light engine / OLED LED compact. Umodule SLE G4 FASHION EXC

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

Z-POWER LED Series. Technical Datasheet for X92050 SEOUL SEMICONDUCTOR

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

Infusion Module Gen2 M1000, M1500, M2000 and M3000 Series

SST-10-SB. Sky Blue LED. SST-10-Sky Blue Product Datasheet. Features: Table of Contents. Applications

Thermal Management 5. Handling Guide

Experience bright and vivid colors

VR44-MU-xxx-8yy-xxxxA

Infusion Module M4500 Series High lumen LED lighting

120VAC / Universal Input Rectangular LED DC Engines and LED DC Engine Retrofit Kits

LED Modules. Fortimo SLM. Fortimo LED SLM Gen 4 Crisp White

Experience bright and vivid colors

Illumination. A comprehensive portfolio of application optimized LUXEON LEDs and the infinitely configurable Matrix Platform ILLUMINATION LINE CARD

TMU140055CL8xxA 44 LINEARHO DC MODULE, 1400mA MAX CURRENT

RoHS. Specification. Acrich2 Bulb 120V 4.3W SMJE-2V04W1P3. Drawn Approval Approval. Rev. 01 June

VR44-MU-xxx-8yy-xxxxA

LED Modules. Fortimo DLM Flex L2

TMU125050CL8xxA 22 LINEARHO DC MODULE, 1250mA MAX CURRENT

Experience bright and vivid colors

Fortimo LED Line High Flux

DATA SHEET. GLV92C50501 Series. Part of the simpleled Program v1 P-1

VMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT

VR22-MU-xxx-8yy-xxxxA

VMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT

Flexible system approach

VMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT

Transcription:

Bridgelux Gen 7 Vero 13 Array Series Product Data Sheet DS91 1

Introduction Vero Series Vero Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero SE Series, Vero Series, V Series and H Series. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is also designed as a replacement for halogen lamps. Décor Series Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features Efficacy of 155 lm/w typical Lumen output performance ranges from 522 to 7,073 lumens Broad range of CCT options from 2700K to 6500K CRI options include; minimum 70, 80, and 90 2 and 3 SDCM color control for 2700K-4000K CCT Reliable operation at up to 2X nominal drive current Radial die pattern and improved lumen density Thermally isolated solder pads Onboard connector port Top side part number markings V f bin code backside marking Benefits Broad application coverage for interior and exterior lighting Flexibility for application driven lighting design requirements High quality true color reproduction Uniform consistent white light Flexibility in design optimization Enhanced ease of use and assembly Solderless connectivity enables plug & play installation and field upgradability Improved inventory management and quality control

Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 8 Electrical Characteristics 15 Eye Safety 16 Absolute Maximum Ratings 17 Performance Curves 18 Radiation Pattern 21 Color Spectrum 22 Mechanical Dimensions 23 Color Binning Information 24 Packaging and Labeling 25 Design Resources 27 Precautions 27 Disclaimers 27 About Bridgelux 28 1

Product Feature Map Vero 13 is the second smallest form factor in the Vero family of the next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Optics location/mounting features Thermally isolated solder pads reduce manufacturing cycle time and complexity Measurement point Correlates to the true case temperature on the back surface of the LED array Mounting holes Zhaga Book 3 compatible mounting locations Radial die configuration improves lumen density and beam control Top side part number marking improves inventory management and outgoing quality control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: Product Family Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BXRC 30 E 200 0 C 7 3 CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Gen. 7 Array Configuration CCT Bin Options 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 200x = 2000 lm 2

Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (T j = = 25 C) Part Number Nominal CCT 1 (K) CRI 2 Nominal Drive Current 3 (ma) Pulsed Flux 4,5,6 Minimum Pulsed Flux 6,7 V f (V) Power (W) BXRC-27E2000-B-7X 2700 80 450 2323 2090 34.8 15.7 148 BXRC-27E2000-C-7X 2700 80 630 3251 2926 34.8 21.9 148 BXRC-27E2000-D-7X 2700 80 500 2365 2129 31.8 15.9 149 BXRC-27G2000-B-7X 2700 90 450 1936 1742 34.8 15.7 124 BXRC-27G2000-C-7X 2700 90 630 2709 2438 34.8 21.9 124 BXRC-27G2000-D-7X 2700 90 500 1971 1774 31.8 15.9 124 BXRC-27H2000-B-7x 2700 97 450 1698 1529 34.8 15.7 108 BXRC-27H2000-C-7x 2700 97 630 2377 2140 34.8 21.9 108 BXRC-27H2000-D-7x 2700 97 500 1730 1557 31.8 15.9 109 BXRC-30E2000-B-7X 3000 80 450 2441 2178 34.8 15.7 156 BXRC-30E2000-C-7X 3000 80 630 3418 3048 34.8 21.9 156 BXRC-30E2000-D-7X 3000 80 500 2480 2217 31.8 15.9 156 BXRC-30G2000-B-7X 3000 90 450 2008 1807 34.8 15.7 128 BXRC-30G2000-C-7X 3000 90 630 2811 2530 34.8 21.9 128 BXRC-30G2000-D-7X 3000 90 500 2045 1840 31.8 15.9 129 BXRC-30G200C-B-73 3000 90 450 1896 1706 35.0 15.8 120 BXRC-30G200C-D-73 3000 90 500 1908 1717 31.8 15.9 120 BXRC-30H2000-B-7x 3000 97 450 1814 1633 34.8 15.7 116 BXRC-30H2000-C-7x 3000 97 630 2540 2286 34.8 21.9 116 BXRC-30H2000-D-7x 3000 97 500 1848 1663 31.8 15.9 116 BXRC-30A2001-B-73 8,9 3000 93 450 1873 1686 34.8 15.7 120 BXRC-30A2001-C-73 8,9 3000 93 630 2622 2360 34.8 21.9 120 BXRC-30A2001-D-73 8,9 3000 93 500 1907 1717 31.8 15.9 120 BXRC-35E2000-B-7X 3500 80 450 2492 2243 34.8 15.7 159 BXRC-35E2000-C-7X 3500 80 630 3488 3140 34.8 21.9 159 BXRC-35E2000-D-7X 3500 80 500 2538 2284 31.8 15.9 160 BXRC-35G2000-B-7X 3500 90 450 2081 1873 34.8 15.7 133 BXRC-35G2000-C-7X 3500 90 630 2913 2621 34.8 21.9 133 BXRC-35G2000-D-7X 3500 90 500 2119 1907 31.8 15.9 133 BXRC-35A2001-B-73 8,9 3500 93 450 2014 1812 34.8 15.7 129 BXRC-35A2001-C-73 8,9 3500 93 630 2819 2537 34.8 21.9 129 BXRC-35A2001-D-73 8,9 3500 93 500 2050 1845 31.8 15.9 129 Efficacy (lm/w) Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to = 85 C. 2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where T j (junction temperature) = (case temperature) = 25 C. 5. performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70 C. GAI may vary depending on fixture design and performance. 3

Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (T j = = 25 C) (continued) Part Number Nominal CCT 1 (K) CRI 2 Nominal Drive Current 3 (ma) Pulsed Flux 4,5,6 Minimum Pulsed Flux 6,7 V f (V) Power (W) BXRC-40E2000-B-7X 4000 80 450 2516 2265 34.8 15.7 161 BXRC-40E2000-C-7X 4000 80 630 3522 3170 34.8 21.9 161 BXRC-40E2000-D-7X 4000 80 500 2562 2306 31.8 15.9 161 BXRC-40G2000-B-7X 4000 90 450 2153 1938 34.8 15.7 138 BXRC-40G2000-C-7X 4000 90 630 3014 2713 34.8 21.9 137 BXRC-40G2000-D-7X 4000 90 500 2193 1973 31.8 15.9 138 BXRC-40A2001-B-73 8,9 4000 93 450 2154 1939 34.8 15.7 138 BXRC-40A2001-C-73 8,9 4000 93 630 3015 2714 34.8 21.9 138 BXRC-40A2001-D-73 8,9 4000 93 500 2194 1975 31.8 15.9 138 BXRC-50C2001-B-7x 5000 70 450 2758 2482 34.8 15.7 176 BXRC-50C2001-C-7x 5000 70 630 3861 3475 34.8 21.9 176 BXRC-50C2001-D-7x 5000 70 500 2809 2528 31.8 15.9 177 BXRC-50E2001-B-7x 5000 80 450 2593 2334 34.8 15.7 166 BXRC-50E2001-C-7x 5000 80 630 3629 3266 34.8 21.9 166 BXRC-50E2001-D-7x 5000 80 500 2640 2376 31.8 15.9 166 BXRC-50G2001-B-7x 5000 90 450 2207 1986 34.8 15.7 141 BXRC-50G2001-C-7x 5000 90 630 3089 2780 34.8 21.9 141 BXRC-50G2001-D-7x 5000 90 500 2247 2022 31.8 15.9 141 BXRC-57C2001-B-7x 5700 70 450 2662 2395 34.8 15.7 170 BXRC-57C2001-C-7x 5700 70 630 3725 3353 34.8 21.9 170 BXRC-57C2001-D-7x 5700 70 500 2710 2439 31.8 15.9 170 BXRC-57E2001-B-7x 5700 80 450 2637 2374 34.8 15.7 168 BXRC-57E2001-C-7x 5700 80 630 3692 3322 34.8 21.9 168 BXRC-57E2001-D-7x 5700 80 500 2685 2417 31.8 15.9 169 BXRC-65C2001-B-7x 6500 70 450 2710 2439 34.8 15.7 173 BXRC-65C2001-C-7x 6500 70 630 3793 3414 34.8 21.9 173 BXRC-65C2001-D-7x 6500 70 500 2759 2483 31.8 15.9 174 BXRC-65E2001-B-7x 6500 80 450 2686 2417 34.8 15.7 172 BXRC-65E2001-C-7x 6500 80 630 3759 3383 34.8 21.9 171 BXRC-65E2001-D-7x 6500 80 500 2735 2461 31.8 15.9 172 Efficacy (lm/w) Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to = 85 C. 2. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where T j (junction temperature) = (case temperature) = 25 C. 5. performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70 C. GAI may vary depending on fixture design and performance. 4

Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance ( = 70 C) 7,8 Part Number Nominal CCT 1 (K) GAI 2 CRI 3 Nominal Drive Current 4 (ma) DC Flux 5,6 = 70ºC Minimum DC Flux 6,9 = 70ºC V f (V) Power (W) Efficacy (lm/w) BXRC-30A2001-B-73 3000 80 93 450 1742 1568 34.4 15.5 113 BXRC-30A2001-C-73 3000 80 93 630 2438 2195 34.4 21.6 113 BXRC-30A2001-D-73 3000 80 93 500 1774 1597 31.2 15.6 114 BXRC-35A2001-B-73 3500 80 93 450 1873 1685 34.4 15.5 121 BXRC-35A2001-C-73 3500 80 93 630 2622 2359 34.4 21.6 121 BXRC-35A2001-D-73 3500 80 93 500 1907 1716 31.2 15.6 122 BXRC-40A2001-B-73 4000 80 93 450 2003 1803 34.4 15.5 130 BXRC-40A2001-C-73 4000 80 93 630 2804 2524 34.4 21.6 130 BXRC-40A2001-D-73 4000 80 93 500 2040 1837 31.2 15.6 131 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70 C. GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 5

Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance ( = 85 C) 4,5 Part Number Nominal CCT 1 (K) CRI 2 Nominal Drive Current 3 (ma) DC Flux 4,5 = 85ºC Minimum DC Flux 6 = 85ºC V f (V) Power (W) BXRC-27E2000-B-7X 2700 80 450 2090 1881 33.9 15.3 137 BXRC-27E2000-C-7X 2700 80 630 2926 2633 33.9 21.4 137 BXRC-27E2000-D-7X 2700 80 500 2129 1916 30.9 15.5 138 BXRC-27G2000-B-7X 2700 90 450 1742 1568 33.9 15.3 114 BXRC-27G2000-C-7X 2700 90 630 2438 2194 33.9 21.4 114 BXRC-27G2000-D-7X 2700 90 500 1774 1597 30.9 15.5 115 BXRC-27H2000-B-7x 2700 97 450 1528 1376 33.9 15.3 100 BXRC-27H2000-C-7x 2700 97 630 2139 1926 33.9 21.4 100 BXRC-27H2000-D-7x 2700 97 500 1557 1401 30.9 15.5 101 BXRC-30E2000-B-7X 3000 80 450 2197 1960 33.9 15.3 144 BXRC-30E2000-C-7X 3000 80 630 3076 2743 33.9 21.4 144 BXRC-30E2000-D-7X 3000 80 500 2232 1995 30.9 15.5 144 BXRC-30G2000-B-7X 3000 90 450 1807 1626 33.9 15.3 118 BXRC-30G2000-C-7X 3000 90 630 2530 2277 33.9 21.4 118 BXRC-30G2000-D-7X 3000 90 500 1840 1656 30.9 15.5 119 BXRC-30G200C-B-73 3000 90 450 1706 1536 34.1 15.3 111 BXRC-30G200C-D-73 3000 90 500 1717 1545 30.9 15.5 111 BXRC-30H2000-B-7x 3000 97 450 1633 1470 33.9 15.3 107 BXRC-30H2000-C-7x 3000 97 630 2286 2057 33.9 21.4 107 BXRC-30H2000-D-7x 3000 97 500 1663 1497 30.9 15.5 108 BXRC-30A2001-B-73 7,8 3000 93 450 1686 1517 33.9 15.3 110 BXRC-30A2001-C-73 7,8 3000 93 630 2360 2124 33.9 21.4 110 BXRC-30A2001-D-73 7,8 3000 93 500 1716 1545 30.9 15.5 111 BXRC-35E2000-B-7X 3500 80 450 2243 2019 33.9 15.3 147 BXRC-35E2000-C-7X 3500 80 630 3140 2826 33.9 21.4 147 BXRC-35E2000-D-7X 3500 80 500 2284 2056 30.9 15.5 148 BXRC-35G2000-B-7X 3500 90 450 1873 1686 33.9 15.3 123 BXRC-35G2000-C-7X 3500 90 630 2621 2359 33.9 21.4 123 BXRC-35G2000-D-7X 3500 90 500 1907 1716 30.9 15.5 123 BXRC-35A2001-B-73 7,8 3500 93 450 1813 1631 33.9 15.3 119 BXRC-35A2001-C-73 7,8 3500 93 630 2537 2283 33.9 21.4 119 BXRC-35A2001-D-73 7,8 3500 93 500 1845 1661 30.9 15.5 119 Efficacy (lm/w) Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to = 85 C. 2. All CRI values are measured at T j = = 25 C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85 C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70 C. GAI may vary depending on fixture design and performance. 6

Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance ( = 85 C) 4,5 (continued) Part Number Nominal CCT 1 (K) CRI 2 Nominal Drive Current 3 (ma) DC Flux 4,5 = 85ºC Minimum DC Flux 6 = 85ºC V f (V) Power (W) Efficacy (lm/w) BXRC-40E2000-B-7X 4000 80 450 2265 2039 33.9 15.3 148 BXRC-40E2000-C-7X 4000 80 630 3170 2853 33.9 21.4 148 BXRC-40E2000-D-7X 4000 80 500 2306 2075 30.9 15.5 149 BXRC-40G2000-B-7X 4000 90 450 1938 1744 33.9 15.3 127 BXRC-40G2000-C-7X 4000 90 630 2713 2442 33.9 21.4 127 BXRC-40G2000-D-7X 4000 90 500 1973 1776 30.9 15.5 128 BXRC-40A2001-B-73 7,8 4000 93 450 1939 1745 33.9 15.3 127 BXRC-40A2001-C-73 7,8 4000 93 630 2714 2443 33.9 21.4 127 BXRC-40A2001-D-73 7,8 4000 93 500 1975 1778 30.9 15.5 128 BXRC-50C2001-B-7x 5000 70 450 2482 2234 33.9 15.3 163 BXRC-50C2001-C-7x 5000 70 630 3475 3128 33.9 21.4 163 BXRC-50C2001-D-7x 5000 70 500 2528 2275 30.9 15.5 163 BXRC-50E2001-B-7x 5000 80 450 2334 2101 33.9 15.3 153 BXRC-50E2001-C-7x 5000 80 630 3266 2939 33.9 21.4 153 BXRC-50E2001-D-7x 5000 80 500 2376 2138 30.9 15.5 154 BXRC-50G2001-B-7x 5000 90 450 1986 1787 33.9 15.3 130 BXRC-50G2001-C-7x 5000 90 630 2780 2502 33.9 21.4 130 BXRC-50G2001-D-7x 5000 90 500 2022 1820 30.9 15.5 131 BXRC-57C2001-B-7x 5700 70 450 2395 2156 33.9 15.3 157 BXRC-57C2001-C-7x 5700 70 630 3353 3018 33.9 21.4 157 BXRC-57C2001-D-7x 5700 70 500 2439 2195 30.9 15.5 158 BXRC-57E2001-B-7x 5700 80 450 2374 2137 33.9 15.3 156 BXRC-57E2001-C-7x 5700 80 630 3322 2990 33.9 21.4 156 BXRC-57E2001-D-7x 5700 80 500 2417 2175 30.9 15.5 156 BXRC-65C2001-B-7x 6500 70 450 2439 2195 33.9 15.3 160 BXRC-65C2001-C-7x 6500 70 630 3414 3073 33.9 21.4 160 BXRC-65C2001-D-7x 6500 70 500 2483 2235 30.9 15.5 161 BXRC-65E2001-B-7x 6500 80 450 2417 2175 33.9 15.3 158 BXRC-65E2001-C-7x 6500 80 630 3383 3045 33.9 21.4 158 BXRC-65E2001-D-7x 6500 80 500 2461 2215 30.9 15.5 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to = 85 C. 2. All CRI values are measured at T j = = 25 C. CRI values are typical for Decor Series Ultra and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85 C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70 C. GAI may vary depending on fixture design and performance. 7

Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-27E2000-B-7X 80 BXRC-27E2000-C-7X 80 BXRC-27E2000-D-7X 80 BXRC-27G2000-B-7X 90 BXRC-27G2000-C-7X 90 BXRC-27G2000-D-7X 90 BXRC-27H2000-B-7x 97 BXRC-27H2000-C-7x 97 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 113 33.2 3.7 633 580 169 225 34.0 7.7 1224 1110 160 450 34.8 15.7 2323 2090 148 675 35.6 24.1 3357 2940 140 900 36.1 32.5 4282 3678 132 158 33.2 5.2 878 831 168 315 34.0 10.7 1701 1601 159 630 34.8 21.9 3251 2926 148 945 35.6 33.7 4667 4363 139 1260 36.1 45.5 5956 5550 131 125 29.6 3.7 626 598 169 250 30.3 7.6 1214 1156 160 500 31.8 15.9 2365 2129 149 750 33.2 24.9 3342 3166 134 1000 34.4 34.4 4274 4039 124 113 33.2 3.7 527 483 141 225 34.0 7.7 1020 925 133 450 34.8 15.7 1936 1742 124 675 35.6 24.1 2797 2450 116 900 36.1 32.5 3568 3065 110 158 33.2 5.2 732 692 140 315 34.0 10.7 1417 1335 132 630 34.8 21.9 2709 2438 124 945 35.6 33.7 3889 3635 115 1260 36.1 45.5 4963 4625 109 125 29.6 3.7 522 498 141 250 30.3 7.6 1011 963 133 500 31.8 15.9 1971 1774 124 750 33.2 24.9 2785 2639 112 1000 34.4 34.4 3561 3365 103 113 33.2 3.7 462 424 124 225 34.0 7.7 895 812 117 450 34.8 15.7 1698 1528 108 675 35.6 24.1 2454 2149 102 900 36.1 32.5 3130 2689 96 158 33.2 5.2 642 607 123 315 34.0 10.7 1243 1171 116 630 34.8 21.9 2377 2139 108 945 35.6 33.7 3412 3190 101 1260 36.1 45.5 4355 4057 96 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27H2000-D-7x 97 BXRC-30E2000-B-7X 80 BXRC-30E2000-C-7X 80 BXRC-30E2000-D-7X 80 BXRC-30G2000-B-7X 90 BXRC-30G2000-C-7X 90 BXRC-30G2000-D-7X 90 BXRC-30G200C-B-73 90 BXRC-30G200C-D-73 90 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 125 29.6 3.7 458 437 124 250 30.3 7.6 888 845 117 500 31.8 15.9 1730 1557 109 750 33.2 24.9 2444 2316 98 1000 34.4 34.4 3126 2954 91 113 33.2 3.7 665 609 178 225 34.0 7.7 1287 1167 168 450 34.8 15.7 2441 2197 156 675 35.6 24.1 3528 3090 147 900 36.1 32.5 4500 3865 138 158 33.2 5.2 923 873 177 315 34.0 10.7 1788 1683 167 630 34.8 21.9 3418 3076 156 945 35.6 33.7 4905 4586 146 1260 36.1 45.5 6261 5834 137 125 29.6 3.7 656 627 178 250 30.3 7.6 1273 1212 168 500 31.8 15.9 2480 2232 156 750 33.2 24.9 3505 3320 141 1000 34.4 34.4 4481 4235 130 113 33.2 3.7 547 501 146 225 34.0 7.7 1059 960 138 450 34.8 15.7 2008 1807 128 675 35.6 24.1 2902 2542 121 900 36.1 32.5 3702 3180 114 158 33.2 5.2 760 718 145 315 34.0 10.7 1470 1385 137 630 34.8 21.9 2811 2530 128 945 35.6 33.7 4035 3772 120 1260 36.1 45.5 5149 4798 113 125 29.6 3.7 541 517 147 250 30.3 7.6 1049 999 138 500 31.8 15.9 2045 1840 129 750 33.2 24.9 2890 2738 116 1000 34.4 34.4 3695 3492 107 113 33.2 3.7 516 473 138 225 34.0 7.7 999 906 131 450 34.8 15.7 1896 1706 121 675 35.6 24.1 2740 2400 114 900 36.1 32.5 3495 3002 107 125 29.6 3.7 505 482 137 250 30.3 7.6 979 933 129 500 31.8 15.9 1908 1717 120 750 33.2 24.9 2696 2554 108 1000 34.4 34.4 3448 3258 100 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 9

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30H2000-B-7x 97 BXRC-30H2000-C-7x 97 BXRC-30H2000-D-7x 97 BXRC-30A2001-B-73 93 BXRC-30A2001-C-73 93 BXRC-30A2001-D-73 93 BXRC-35E2000-B-7X 80 BXRC-35E2000-C-7X 80 BXRC-35E2000-D-7X 80 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 113 33.2 3.7 494 453 132 225 34.0 7.7 956 867 125 450 34.8 15.7 1814 1633 116 675 35.6 24.1 2622 2296 109 900 36.1 32.5 3345 2873 103 158 33.2 5.2 686 649 131 315 34.0 10.7 1328 1251 124 630 34.8 21.9 2540 2286 116 945 35.6 33.7 3645 3408 108 1260 36.1 45.5 4653 4335 102 125 29.6 3.7 489 467 132 250 30.3 7.6 948 903 125 500 31.8 15.9 1848 1663 116 750 33.2 24.9 2611 2474 105 1000 34.4 34.4 3339 3155 97 113 33.2 3.7 510 467 137 225 34.0 7.7 987 895 129 450 34.8 15.7 1873 1686 120 675 35.6 24.1 2707 2370 113 900 36.1 32.5 3453 2966 106 158 33.2 5.2 708 670 135 315 34.0 10.7 1371 1291 128 630 34.8 21.9 2622 2360 120 945 35.6 33.7 3763 3518 112 1260 36.1 45.5 4803 4475 105 125 29.6 3.7 505 482 137 250 30.3 7.6 979 932 129 500 31.8 15.9 1907 1716 120 750 33.2 24.9 2695 2553 108 1000 34.4 34.4 3446 3256 100 113 33.2 3.7 679 622 182 225 34.0 7.7 1314 1191 172 450 34.8 15.7 2492 2243 159 675 35.6 24.1 3602 3154 150 900 36.1 32.5 4594 3946 141 158 33.2 5.2 943 891 180 315 34.0 10.7 1825 1718 170 630 34.8 21.9 3488 3140 159 945 35.6 33.7 5007 4681 149 1260 36.1 45.5 6390 5954 140 125 29.6 3.7 672 642 182 250 30.3 7.6 1302 1240 172 500 31.8 15.9 2538 2284 160 750 33.2 24.9 3586 3397 144 1000 34.4 34.4 4585 4333 133 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35G2000-B-7X 90 BXRC-35G2000-C-7X 90 BXRC-35G2000-D-7X 90 BXRC-35A2001-B-73 93 BXRC-35A2001-C-73 93 BXRC-35A2001-D-73 93 BXRC-40E2000-B-7X 80 BXRC-40E2000-C-7X 80 BXRC-40E2000-D-7X 80 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 113 33.2 3.7 567 519 152 225 34.0 7.7 1097 995 143 450 34.8 15.7 2081 1873 133 675 35.6 24.1 3007 2633 125 900 36.1 32.5 3836 3295 118 158 33.2 5.2 787 744 150 315 34.0 10.7 1523 1435 142 630 34.8 21.9 2913 2621 133 945 35.6 33.7 4180 3908 124 1260 36.1 45.5 5336 4971 117 125 29.6 3.7 561 536 152 250 30.3 7.6 1087 1036 143 500 31.8 15.9 2119 1907 133 750 33.2 24.9 2994 2837 120 1000 34.4 34.4 3828 3618 111 113 33.2 3.7 548 503 147 225 34.0 7.7 1062 963 139 450 34.8 15.7 2014 1813 129 675 35.6 24.1 2911 2549 121 900 36.1 32.5 3713 3189 114 158 33.2 5.2 762 720 146 315 34.0 10.7 1474 1389 138 630 34.8 21.9 2819 2537 129 945 35.6 33.7 4046 3783 120 1260 36.1 45.5 5164 4812 113 125 29.6 3.7 543 518 147 250 30.3 7.6 1052 1002 139 500 31.8 15.9 2050 1845 129 750 33.2 24.9 2897 2744 116 1000 34.4 34.4 3704 3500 108 113 33.2 3.7 685 628 183 225 34.0 7.7 1326 1203 173 450 34.8 15.7 2516 2265 161 675 35.6 24.1 3636 3185 151 900 36.1 32.5 4639 3984 143 158 33.2 5.2 952 900 182 315 34.0 10.7 1842 1735 172 630 34.8 21.9 3522 3170 161 945 35.6 33.7 5055 4726 150 1260 36.1 45.5 6452 6012 142 125 29.6 3.7 678 648 184 250 30.3 7.6 1315 1252 173 500 31.8 15.9 2562 2306 161 750 33.2 24.9 3621 3430 145 1000 34.4 34.4 4630 4375 134 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40G2000-B-7X 90 BXRC-40G2000-C-7X 90 BXRC-40G2000-D-7X 90 BXRC-40A2001-B-73 93 BXRC-40A2001-C-73 93 BXRC-40A2001-D-73 93 BXRC-50C2001-B-7x 70 BXRC-50C2001-C-7x 70 BXRC-50C2001-D-7x 70 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 113 33.2 3.7 586 537 157 225 34.0 7.7 1135 1030 148 450 34.8 15.7 2153 1938 138 675 35.6 24.1 3112 2725 129 900 36.1 32.5 3970 3410 122 158 33.2 5.2 814 770 156 315 34.0 10.7 1577 1485 147 630 34.8 21.9 3014 2713 137 945 35.6 33.7 4326 4044 128 1260 36.1 45.5 5522 5145 121 125 29.6 3.7 580 554 157 250 30.3 7.6 1125 1072 148 500 31.8 15.9 2193 1973 138 750 33.2 24.9 3099 2935 124 1000 34.4 34.4 3962 3744 115 113 33.2 3.7 587 538 157 225 34.0 7.7 1135 1030 148 450 34.8 15.7 2154 1939 138 675 35.6 24.1 3113 2726 129 900 36.1 32.5 3971 3411 122 158 33.2 5.2 815 770 156 315 34.0 10.7 1577 1485 147 630 34.8 21.9 3015 2714 138 945 35.6 33.7 4327 4046 129 1260 36.1 45.5 5523 5146 121 125 29.6 3.7 581 555 157 250 30.3 7.6 1126 1072 148 500 31.8 15.9 2194 1975 138 750 33.2 24.9 3100 2937 125 1000 34.4 34.4 3964 3746 115 113 33.2 3.7 751 688 201 225 34.0 7.7 1454 1319 190 450 34.8 15.7 2758 2482 176 675 35.6 24.1 3986 3491 166 900 36.1 32.5 5085 4367 156 158 33.2 5.2 1043 986 199 315 34.0 10.7 2019 1902 189 630 34.8 21.9 3861 3475 176 945 35.6 33.7 5542 5181 165 1260 36.1 45.5 7073 6590 155 125 29.6 3.7 743 710 201 250 30.3 7.6 1441 1373 190 500 31.8 15.9 2809 2528 177 750 33.2 24.9 3969 3760 159 1000 34.4 34.4 5075 4796 147 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50E2001-B-7x 80 BXRC-50E2001-C-7x 80 BXRC-50E2001-D-7x 80 BXRC-50G2001-B-7x 90 BXRC-50G2001-C-7x 90 BXRC-50G2001-D-7x 90 BXRC-57C2001-B-7x 70 BXRC-57C2001-C-7x 70 BXRC-57C2001-D-7x 70 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 113 33.2 3.7 706 647 189 225 34.0 7.7 1367 1240 179 450 34.8 15.7 2593 2334 166 675 35.6 24.1 3747 3281 156 900 36.1 32.5 4780 4105 147 158 33.2 5.2 981 927 187 315 34.0 10.7 1898 1788 177 630 34.8 21.9 3629 3266 166 945 35.6 33.7 5209 4870 155 1260 36.1 45.5 6648 6195 146 125 29.6 3.7 699 667 189 250 30.3 7.6 1355 1290 179 500 31.8 15.9 2640 2376 166 750 33.2 24.9 3731 3534 150 1000 34.4 34.4 4770 4508 139 113 33.2 3.7 601 551 161 225 34.0 7.7 1163 1055 152 450 34.8 15.7 2207 1986 141 675 35.6 24.1 3189 2793 133 900 36.1 32.5 4068 3494 125 158 33.2 5.2 835 789 160 315 34.0 10.7 1616 1521 151 630 34.8 21.9 3089 2780 141 945 35.6 33.7 4433 4144 132 1260 36.1 45.5 5658 5272 124 125 29.6 3.7 595 568 161 250 30.3 7.6 1153 1098 152 500 31.8 15.9 2247 2022 141 750 33.2 24.9 3175 3008 128 1000 34.4 34.4 4060 3837 118 113 33.2 3.7 725 664 194 225 34.0 7.7 1403 1272 183 450 34.8 15.7 2662 2395 170 675 35.6 24.1 3846 3368 160 900 36.1 32.5 4906 4214 151 158 33.2 5.2 1007 952 192 315 34.0 10.7 1949 1835 182 630 34.8 21.9 3725 3353 170 945 35.6 33.7 5347 4999 159 1260 36.1 45.5 6825 6359 150 125 29.6 3.7 717 685 194 250 30.3 7.6 1391 1325 183 500 31.8 15.9 2710 2439 170 750 33.2 24.9 3830 3628 154 1000 34.4 34.4 4897 4627 142 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13

Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57E2001-B-7x 80 BXRC-57E2001-C-7x 80 BXRC-57E2001-D-7x 80 BXRC-65C2001-B-7x 70 BXRC-65C2001-C-7x 70 BXRC-65C2001-D-7x 70 BXRC-65E2001-B-7x 80 BXRC-65E2001-C-7x 80 BXRC-65E2001-D-7x 80 Drive Current 1 (ma) V f (V) Power (W) Flux 2 DC Flux 3 = 85ºC Efficacy (lm/w) 113 33.2 3.7 718 658 192 225 34.0 7.7 1390 1261 182 450 34.8 15.7 2637 2374 168 675 35.6 24.1 3811 3338 158 900 36.1 32.5 4862 4176 149 158 33.2 5.2 997 943 191 315 34.0 10.7 1931 1818 180 630 34.8 21.9 3692 3322 168 945 35.6 33.7 5298 4953 157 1260 36.1 45.5 6762 6301 148 125 29.6 3.7 711 679 192 250 30.3 7.6 1378 1313 182 500 31.8 15.9 2685 2417 169 750 33.2 24.9 3795 3595 152 1000 34.4 34.4 4852 4585 141 113 33.2 3.7 738 676 198 225 34.0 7.7 1429 1296 187 450 34.8 15.7 2710 2439 173 675 35.6 24.1 3916 3430 163 900 36.1 32.5 4995 4291 154 158 33.2 5.2 1025 969 196 315 34.0 10.7 1984 1868 185 630 34.8 21.9 3793 3414 173 945 35.6 33.7 5444 5090 162 1260 36.1 45.5 6949 6474 153 125 29.6 3.7 730 698 198 250 30.3 7.6 1416 1349 187 500 31.8 15.9 2759 2483 174 750 33.2 24.9 3899 3694 157 1000 34.4 34.4 4986 4712 145 113 33.2 3.7 731 670 196 225 34.0 7.7 1416 1284 185 450 34.8 15.7 2686 2417 172 675 35.6 24.1 3881 3399 161 900 36.1 32.5 4951 4253 152 158 33.2 5.2 1016 960 194 315 34.0 10.7 1966 1852 184 630 34.8 21.9 3759 3383 171 945 35.6 33.7 5396 5044 160 1260 36.1 45.5 6887 6417 151 125 29.6 3.7 724 691 196 250 30.3 7.6 1403 1337 185 500 31.8 15.9 2735 2461 172 750 33.2 24.9 3865 3661 155 1000 34.4 34.4 4941 4670 144 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14

Electrical Characteristics Table 5: Electrical Characteristics Part Number Drive Current (ma) Forward Voltage 1, 2, 3, 8 Pulsed, (V) Minimum Maximum Coefficient of Forward Voltage 4 V f / (mv/ºc) Thermal Resistance Junction to Case 5,6 R j-c (ºC/W) Driver Selection Voltages 7 (V) V f Min. Hot = 105ºC (V) V f Max. Cold = -40ºC (V) BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x 450 32.2 34.8 37.4-14.3 0.28 31.0 38.3 900 33.4 36.1 38.8-14.3 0.35 32.2 39.7 630 32.2 34.8 37.4-14.3 0.20 31.0 38.3 1260 33.4 36.1 38.8-14.3 0.24 32.2 39.7 500 29.4 31.8 34.2-13.3 0.34 28.4 35.0 1000 31.8 34.4 37.0-13.3 0.41 30.8 37.9 Notes for Table 5: 1. Parts are tested in pulsed conditions, = 25 C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. V f min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 15

Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number Drive Current 5 (ma) CCT 1,5 2700K/3000K 4000K 2 5000K 3 6500K 4 BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x 450 RG1 RG1 RG1 RG1 675 RG1 RG1 RG1 RG2 900 RG1 RG1 RG2 RG2 630 RG1 RG1 RG1 RG1 945 RG1 RG1 RG2 RG2 1260 RG1 RG2 RG2 RG2 500 RG1 RG1 RG1 RG1 750 RG1 RG1 RG1 RG2 1000 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, E thr = 1847.5 lx. 3. For products classified as RG2 at 5000K E thr = 1315.8 lx. 4. For products classified as RG2 at 6500K, E thr = 1124.5 lx. 5. Please contact your Bridgelux sales representative for E thr values at specific drive currents and CCTs not listed. 16

Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (T j ) 125 C Storage Temperature -40 C to +105 C Operating Case Temperature 1 ( ) 105 C Soldering Temperature 2 300 C or lower for a maximum of 6 seconds BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x Maximum Drive Current 3 900mA 1260mA 1000mA Maximum Peak Pulsed Drive Current 4 1290mA 1800mA 1430mA Maximum Reverse Voltage 5-60V -60V -55V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 17

Performance Curves Figure 1: Vero 13B Drive Current vs. Voltage Figure 2: Vero 13C Drive Current vs. Voltage 1000 900 800 1400 1200 Forward Current (ma) 700 600 500 400 300 200 100 0 32 33 34 35 36 37 38 Forward Voltage (V) Forward Current (ma) 1000 800 600 400 200 0 32 33 34 35 36 37 38 Forward Voltage (V) Figure 3: Vero 13D Drive Current vs. Voltage Figure 4: Vero 13B Relative Flux vs. Current Forward Current (ma) 1100 1000 900 800 700 600 500 400 300 200 100 0 29 30 31 32 33 34 35 Forward Voltage (V) Relative Luminous Flux 200% 180% 160% 140% 120% 100% 80% 60% 40% 20% 0% 0 100 200 300 400 500 600 700 800 900 1000 Forward Current (ma) Figure 5: Vero 13C Relative Flux vs. Current Figure 6 Vero 13D Relative Flux vs. Current Relative Luminous Flux 200% 180% 160% 140% 120% 100% 80% 60% 40% 20% 0% 100 250 400 550 700 850 1000 1150 1300 Forward Current (ma) Relative Luminous Flux 200% 180% 160% 140% 120% 100% 80% 60% 40% 20% 0% 0 100 200 300 400 500 600 700 800 900 1000 1100 Forward Current (ma) Note for Figure 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where T j (junction temperature) = (case temperature) = 25 C. 18

Performance Curves Figure 7: DC Flux vs. Case Temperature Figure 8: DC ccy Shift vs. Case Temperature Relative Luminous Flux 103% Warm White 100% Neutral White Cool White 97% 25 C Pulsed 94% 91% 88% 85% 82% 0 25 50 75 100 125 Case Temperature ( C) ccy Shift 0 25 50 75 100 125 0.003 0.000-0.003-0.006-0.009 Warm White -0.012 Neutral White Cool White 25 C Pulsed -0.015 Case Temperature ( C) Figure 9: DC ccx Shift vs. Case Temperature 0 25 50 75 100 125 0.000-0.002-0.004 ccx Shift -0.006-0.008-0.010-0.012 Warm White Neutral White Cool White 25 C Pulsed Case Temperature ( C) Notes for Figures 7-9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 19

Performance Curves Figure 10: 2700K, 97 CRI Color Shift vs. Case Temperature 1 Figure 11: 3000K, 97 CRI Color Shift vs. Case Temperature 1 0.4110 0.4100 0.4090 15 C 25 C Pulsed Center Point = 25 C 0.4050 0.4030 15 C 25 C Pulsed Center Point = 25 C 0.4080 45 C 0.4010 45 C ccy 0.4070 0.4060 0.4050 85 C 65 C ccy 0.3990 0.3970 105 C 70 C 85 C 0.4040 105 C 0.4030 0.457 0.4572 0.4574 0.4576 0.4578 0.458 ccx 0.3950 0.4323 0.4328 0.4333 0.4338 0.4343 0.4348 0.4353 ccx Figure 12: 3000K, 90 CRI Color Shift vs. Case Temperature 3 Figure 13: 3000K Class A Color Shift vs. Case Temperature 1 0.403 0.402 0.401 15 C 25 C Pulsed Center Point =25 C 0.369 0.368 0.367 15 C 25 C Pulsed Center Point =25 C ccy 0.4 0.399 0.398 0.397 85 C 45 C 65 C ccy 0.366 0.365 0.364 0.363 0.362 85 C 70 C 45 C 0.396 105 C 0.395 0.444 0.4445 0.445 0.4455 0.446 0.4465 0.447 ccx 0.361 105 C 0.36 0.416 0.4165 0.417 0.4175 0.418 0.4185 ccx Figure 14: 3500K Class A Color Shift vs. Case Temperature 1 Figure 15: 4000K Class A Color Shift vs. Case Temperature 1 ccy 0.37 0.368 0.366 0.364 0.362 85 C 70 C 45 C 25 C 15 C Pulsed Center Point =25 C ccy 0.3760 0.3740 0.3720 0.3700 0.3680 0.3660 85 C 70 C 45 C 25 C 15 C Pulsed Center Point =25 C 0.36 105 C 0.358 0.392 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 10-15: 1. Measurements made under DC test conditions at the nominal drive current. 2. color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRC-30G200C-x-73 0.3640 105 C 0.3620 0.373 0.374 0.375 0.376 0.377 0.378 0.379 ccx 20

Radiation Pattern Figure 16: Spatial Radiation Pattern Note for Figure 16: 1. viewing angle is 120 ⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 17: Polar Radiation Pattern 21

Color Spectrum Figure 18: Color Spectrum Relative Spectral Power Distribution 110% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 3000K 4000K 5000K 6500K 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 18: 1. Color spectra measured at nominal current for T j = = 25 C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 19: Color Spectrum for Vero 13 with Décor Series 1 27H 0.9 0.8 30H 30G (Décor Series Showcase) Relative Spectral Power Distribution 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 19: 1. Color spectra measured at nominal current for T j = = 25 C. 22

Mechanical Dimensions Figure 20: Drawing for Vero 13 LED Array Notes for Figure 20: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled + and - to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 23

Color Binning Information Figure 21: Warm and Neutral White Test Bins in xy Color Space Figure 22: Cool White Test Bins in xy Color Space 0.44 0.42 3 SDCM 2 SDCM 3000K 2700K 0.39 0.38 0.37 4 SDCM 3 SDCM 5000K Y 0.4 4000K 3500K Y 0.36 0.35 5700K 0.38 0.34 0.33 6500K 0.36 0.32 0.31 0.34 0.36 0.39 0.42 0.45 0.48 X 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, = 25 C Note: Pulsed Test Conditions, = 25 C Table 8: Warm and Neutral White xy Bin Coordinates and Associated CCT Bin Code 2700K 3000K 1 3500K 1 4000K 1 ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024) 2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Table 9: Cool White xy Bin Coordinates and Associated CCT (product is hot targeted to = 85 C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 24

Packaging and Labeling Figure 23: Drawing for Vero 13 Packaging Tray Notes for Figure 23: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 25

Packaging and Labeling Figure 24: Vero Series Packaging and Labeling Notes for Figure 24: 1. Each tray holds 100 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 25: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E2000C 73 2F Customer Use- V f Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 26

Design Resources Application Notes Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Optical Source Models Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. Precautions 3D CAD Models Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. LM80 LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. STANDARD TEST CONDITIONS Unless otherwise stated, array testing is performed at the nominal drive current. 27

About Bridgelux: We Build Light That Transforms At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light s impact on human behavior, delivering products that create better environments, experiences and returns both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/bridgelux facebook.com/bridgelux youtube.com/user/bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 Tel (925) 583-8400 www.bridgelux.com 2016-2017 Bridgelux, Inc. All rights reserved 2016. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 Vero 13 Array Series Product Data Sheet DS91 Rev. J (6/2017) 28