Operating Instructions Pedestrian Turnstile Type MPT 33

Similar documents
Operating Instructions Type MPT 53

BR230 MOTORIZED VIP. OPERATION and MAINTENANCE MANUAL

(1032 mm) 30.5 (775 mm) 44 ( mm)

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

RotaTech FH Manual Security Turnstile

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Sentry Battery Charger. Installation and Operations Manual Section 75

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

91 (2311 mm) (1581mm) (1375 mm)

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Safety door-handle system STS

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Operating Instructions. Angle Seat Control Valve. Type 7020

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

RevoSec. Manual Full-Height Turnstile for Internal Installation. Passage in both directions is electronically controlled.

Instruction Manual. Sewage lifting station compli 300

RevoSec. Manual Full-Height Turnstile for Internal Installation. Passage in both directions is electronically controlled.

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Combined Ventilation Controller RVWS-T-224HA

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Operating manual UPS - System

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

K25000 & KD25000 Series

Guardian Battery Charger Series. Installation and Operations Manual Section 75

RotaSec FOS. Manual Full-Height Turnstile for External Installation. Passage in both directions is electronically controlled.

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

RevoSec. Manual Full-Height-Turnstile for Internal Installation

MST. Full Height Turnstiles. alvaradomfg.com

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

HIGH SPEED SLIDING GATE OPENER

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

PSM72H Push-Button Start Module

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

Clamping and drive module

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Technical Manual Electrical Power Supply System T4002

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Operating Instructions CYR52

VERG 24V BARRIER. English

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

Emergency lighting units EM converterled

SlimStile EV. Tripod Turnstile for Internal or External Installation (*)

Instruction Manual for the. E-SL 450 Series

Oil-free piston compressors KK and piston vacuum pumps KV

MWF+ Application. Types Available. Average temperature sensor. Datasheet

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

2904 Power Supply Installation Instructions I-EA00041

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

ECONOMISER SERIES E2T USER MANUAL

Stack Parking Surface Mounted Stackers

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Uninterruptible Power System

Effective discrimination of protective devices

Assembly and Operating Instructions

Monocellular centrifugal electro-pumps

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

Electronic Ballast EVG 2000-T

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Patient Care Facility

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Enelion Vertica. Installation manual. 22 kw. for the specialists

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

JANDS DD-8. Technical Manual. Version 1.0

Emergency lighting units EM powerled

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

X-JET (Counter current system)

Emergency lighting units EM converterled

Solenoid interlock AZM 200 The non-contact interlock.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

X JET (Counter current system) Instruction Manual

Installation, Operation and Maintenance Manual

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

BETA Switching Switches and Light Indicators

RELAY BOX PRODUCT MANUAL IMPORTANT

Emergency lighting units EM converterled

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

2.7. IT system floor-standing distribution cabinet Series -IPS-F

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

Series A Electric Linear Actuators

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Transcription:

Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11 7. Access control devices...12 8. Options...13 9. Commissioning...14 10. Technical support...14 11. Spare parts and accessories...14-15 12. Warranty...16 13. Controler MSC 10...... 20-22 581E,5811 10.03_MPT 33 1

1. Delivery The Security Turnstile consists of: 1 x Semi cage made of stainless steel or mild steel 1 x Center column 3 x 120, stainless steel or mild steel 1 x Top housing with locking unit 1 x U-bar locking unit 1 x Electronic controller MSC10 1 x Set of documents inside the lockable top cover 1 x Fixing achors (in Europe only) 2 x Keys for the top cover Technical Data: Typ MPT 33 Protection IP Voltage VAC Frequency Hz Current A Duty Cycle % Weight Kg Height mm Diameter mm 54 230 50 2,5 100 320 2230 1300 2. Safety 2.1 General safety notes The Magnetic pedestrian turnstile has been designed, built and tested according to the latest technology. Although it has left the factory in a fully operational and safe condition, it is important that the installation is carried out correctly therefore the operating instructions must be read carefully and the safety notes must be observed. Any liability and warranty is declined by the manufacturer in the case of incorrect use and use for purposes other than intended. 2.2 Use for the intended purpose The Magnetic pedestrian turnstile may be used only to control pedestrians entering or exiting restricted areas, usually under surveillance. The Magnetic Universal Controller may be used only for controlling the Magnetic pedestrian turnstile. Any other use is not permitted. Conversions and modifications to the turnstile or to the control modules are not permitted. Only original spare parts and accessories from Magnetic may be used. 581E,5811 10.03_MPT 33 2

2.3 Identification of risks Possible risks and notes are identified with the following symbols in the operating instructions: Warning! This symbol in the operating instructions identifies actions and conditions which can give rise to danger for life and limb of persons. Observe the instructions carefully. Caution! All actions and conditions which can possibly give rise to damage to objects are identified with this symbol in the operating instructions. Observe the instructions carefully. Note! Relevant and useful notes for the user are identified with this symbol. 2.4 Safety notes Disconnect all external opening or closing devices (remote control, control desk, etc.) during maintenance work It is prohibited to install the barrier without proper mounting to the foundation A main power switch or residual current operated device is compulsory Risk of bodily harm while cover is open Pedestrian barriers are maintenance free Documentation should be easily accessible. Before commissioning make sure all electrical and functional features are tested. Permissible environmental conditions The electrical wiring of the barrier must comply with the included drawings. Only certified and trained electrical technicians may perform the electrical connections Only certified and trained electrical technicians may remove covers for mains plug,mains receivers or wirings Before repairing electrical failures disconnect fuse Risk of bodily harm if while closing the cover During maintenance work the fixing bolt must be checked and tighten, if necessary. Current carrying components like transformers, solenoids, resistors, stator housings of motors, lamps etc. shall not be touched while in operatingtemperature condition; this can cause skin burns 581E,5811 10.03_MPT 33 3

3. Product description The MPT series of turnstiles are designed to control pedestrians entering or exiting restricted areas outside in high security situations. The turnstile consists of four different component parts (see fig. 1) It can be used for bidirectional access control by means of keys or card readers (access control devices in general). Entry and exit of the barrier can either be operated in open, controlled or closed modus. The rotating centre column consists of 3 x 120 degreeu bars. The controller, the drive units and the locking device are mounted on top of the centre unit in a powder coated sheet metal enclosure, where there is also space for additional access control equipment.locking and release of the centre is realized by an electro-mechanical locking device with solenoids. Fig.1 581E,5811 10.03_MPT 33 4

4. Foundation A level concrete mounting surface is required to secure the turnstile housing. For the dimensions please refer to figure 2. The cables should finish a minimum of 5 meters above the finished concrete surface. NOTE: This foundation is also required in connection with a foundation frame. Conduits for mains supply and data lines should finish 50 mm approx. above foundation Passage direction Empty conduit Empty conduit bearing Passage direction Fig. 2 Foundation anchor pin with inside thread M10 Drilling hole Ǿ 16 Drilling depth 90 mm 581E,5811 10.03_MPT 33 5

Foundation, smoothed finish to be positioned in water in a level and horizontal manner Lay seperate conduits for power supply and data cables, 50 mm approx. above foundation All power supply and data lines are to be 5 m at least above the empty conduit Concrete PC 250 with iron reinforcement After mounting glue set screw with LOCTITE 241 or similar empty conduit O 25 mm srew split washer washer socket bearing neck washer bearing Fig.3 581E,5811 10.03_MPT 33 6

4.1 Foundation frame The foundation frame is required for turnstiles to be mounted on a subground, for example in case of pavers. A level concrete mounting surface is required for correct mounting of the foundation frame. It should be 150 mm approx. below the finished surface. Mounting of the foundation frame: correct positioning of foundation frame, drilling of fixing holes, install fixing bolts, lay the foundation frame into water by means of jackscrews and tighten the foundation frame. Fundamentdübel(F) Express-Anker M12x153/55 A4 Bohrloch Ǿ12 Bohrtiefe 145 mm incl. U-Profilhöhe Fig.4 Cable routing from foundation into turnstile Jackscrews For positioning the foundation Frame on the concrete, if necessary. 581E,5811 10.03_MPT 33 7

5. Assembly and installation 5.1 To fit the turnstile (above ground foundation) The turnstile should be positioned in its desired location taking care on which side (right or left) you want part 2 to place for access the system. This is important in case you want to mount housings for access control units at part 2. Foundation drillings 7 x M16 as per drilling plan figure 2 Mount threaded rod (see enclosed separate description) Wait till bolts are cured (see separate description) Mount the components in correct order (part 1, 2..) onto the foundation, however, do not tighten entirely the bolts in order to compensate any drilling offset which may occur afterwards. Use screws 6 x M 10 x35. Grease the screws before. part 3 part 1 part 2 part 4 Fig.5 Place part 3 upon part 1 and 2. Use screws 8 x M12 x 35 and counternut. Mount lower bearing (see fig. 8). Using screws M10 x 70. Grease them before. Put part 4 on the lower bearing, see fig. 9 and screw it up by means of 4 x M16 x 40 with U-discs and flange. Be sure that the turnstile is in locked position. Now tighten all fixing bolts. 581E,5811 10.03_MPT 33 8

5.2 Fixing on foundation frame See section 5.1 fixing the foundation. However in this case the turnstile is mounted on the flanges of the foundation frame. Fixing of foundation frame, see section 4.1 5.3 Opening of the top cover Fig.6 Opening by key. The cover is secured by means of a chain. Two keys are included in the delivery. 581E,5811 10.03_MPT 33 9

5.4 To fit the turnstile (above ground foundation) Fixing of the turnstile is done by means of the 8 fixing bolts M8 and plain washer. After final positioning tighten all bolts firmly. Note: 1.Mark the dimensions onto foundation acc. to fig.4 2. Drill 3. Install turnstile 4. screw together (see fig. 5.1 Fig. 7 5.5 To fit the centre column Fig. 8 581E,5811 10.03_MPT 33 10

Fig. 9 Mount the lower bearing on the foundation and stick the centre column on it. Fig. 10 Fix the centre column by means of the delivered screws M16 at the top flange. Make sure the centre is in correct position (centre in locked position). 581E,5811 10.03_MPT 33 11

5.6 Assembly of roof with drain Please see fig. 11. Fig.11 581E,5811 10.03_MPT 33 12

6. Electrical connections Connection of mains supply should only be performed b y a certified electrian and According to the connecting diagram or after discussion with the supplier. Fig. 12 Fig.12 Connection unit with control unit MSC10 Fig.13 581E,5811 10.03_MPT 33 13

6.1 Connecting diagram MSC - 10 counter passage left passage right alarm X17 X18 X19 X20 X21 X22 X23 X24 X25 X26 X27 X28 X29 X30 not occupied K1K K2K K3K K4K K5K 24V / 400mA +10%/ -20% 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 MSC Alarm RS232 ON OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 n.c. 19VAC or 24VDC PE 24V 24V Sol. left Sol. right IN1 = opening left IN2 = opening right IN3 = emergency release IN4 = reserve IN5 = limit switch left IN6 = limit switch right IN7 = reserve FIG.14 581E,5811 10.03_MPT 33 14

7. Housings / access control units Fig.15 Possible adaption of surface control devices Rear side of the mounting Lead the cable from the rear side of the mounting plate to the steel tube and drill the hole. Here, for example Fig.16 581E,5811 10.03_MPT 33 15

8. Option Power fail locking mechanism This mechanism will lock the centre column in one or both directions in the event of a power failure. This requires changing of the solenoid, see fig. 17, the components are available on request ( additional kit for MPT 33, ref. no. 1031,5303). The centre column can be turned freely in both directions in its standard configuration. Fig.17 581E,5811 10.03_MPT 33 16

9. Commissioning Once the mechanical and electrical installation of the turnstile has been completed, it can be put into service. Check before startup that all assembly and installation instructions have been followed and the electrical connections have been performed correctly. Warning: Incoming mains supply and connections should only be performed by a certified electrician. When power is first applied and the isolating circuit breaker is turned on, the torque drive turns the centre column several times to find the home position and then locks. The turnstile is then ready for operation. Operation of the Turnstile The Turnstile is generally operated by an access control system or control switches. Special control panels are also available for operation. 10. Technical Support Should faults occur that cannot be rectified by a technician, please contact our authorised aftersales service representative. In special cases our Technical Support is available to you: Telephone: Please refer to the name plate on the turnstile housing for the data required in the case of queries. This is found under the mechansim cover. 11. Spare parts and accessories See Figure 14 for the exploded drawing which details the individual parts and their identification numbers. 581E,5811 10.03_MPT 33 17

Spare parts 581E,5811 10.03_MPT 33 Abb.18 18

12. Warranty The manufacturer reserves the right to adapt technological progress without special announcement. Magnetic will be pleased to provide up to date information and possible changes or additions to the operating instructions. Under the precondition that the operating conditions are complied with and no inadmissible interventions have been made to the interior of the equipment and the equipment has no mechanical damage, a warranty of 2 year after delivery of the equipment applies on all mechanical and electrical components. 581E,5811 10.03_MPT 33 19

13. Control Unit MSC 10 Functions 13.1 Functions of digital inputs Input 1 terminals X21 / X22 = Opening of passage direction left Opening pulse passage left (entry). Input 2 terminals X24 / X 25 = Opening of passage direction right Opening pulse passage right (exit) Input 3 IN3, terminal 11 = input emergency situation In case of emergency passage free in both directions. 13.2 Function of semi conductor outputs Output 1 terminal X6 = solenoid left Output 2 terminal X7 = solenoid right Output 3 terminal X8 = reserve 13.3 Function of relay outputs Relay 1 = counter pulse left terminal X18 If the end position in passage direction left is reached a counter pulse of 300 ms is given. This applies to permanent release also. Relay 2 = counter pulse right terminal X19 If the end position in passage direction left is reached a counter pulse of 300 ms is given. This applies to permanent release also. Relay 3 = Display passage free left terminals X22 + X21 In case of free passage left a permanent signal is given. This output can also be used to lock a pulse transmitter for passage right if passage left is given free. Relay 4 = Display passage free right terminals X 24 + 25 In case of free passage right a permanent signal is given. This output can also be used to lock a pulse transmitter for passage left if passage right is given free. Relay 5 = Error-/Alarm output terminal X27 In case of certain errors a permanent signal is given as long as the error is not eliminated. Relay 6 = Reserve 13.4 Safety functions In case of an error in the microcontroller the watchdog function releases a hardware reset. 581E,5811 10.03_MPT 33 20

14. Adjustable parameters The following parameters can be adjusted by means of DIP switches and the trimming potentiometer: DIP Function OFF ON 1 Barrier type MPT MPP 2 Pulse storage Off On = 4 pulses per direction 3 Locking delay time Off On = 1 sec.approx. 4 Hardware tests *) *) 5 Hardware tests *) *) 6 Solenoid left Normal inverted 7 Solenoid right Normal inverted 8 Opening duration via LEDs No display display DIP 1 Selection of barrier type One of the following barrier types must be selected: - MPP - MPT At present this demand is locked; in every case barrier type MPT is selected. DIP 2 Pulse storage In case the function is switched-off the demand pulses from one direction only can be processed. Demand pulses from the other side are then ignored. In case the function is switched-on max. 4 demand pulses per passage direction can be stored. DIP 3 Locking delay time In order to avoid a rotation of more than 120 in case of permanent release or several stored pulses a locking delay time can be activated via a dip switch. The turnstile is then locked for 1 sec. approx after rotation of 120 and will then be released for passing. DIP 6 Solenoids Via DIP 6 and DIP 7 the function of both solenoids can be inverted separately for both directions. This depends on whether the solenoids are integrated currentless open or closed. DIP 6 affect the left solenoid output and DIP 7 the right one. 581E,5811 10.03_MPT 33 21

DIP 5 Opening duration To be adjusted via trimming potentiomenter between 1 32 sec.. 15. Operating modes 15.1 Pulse operation in both directions without pulse storage 15.2 Pulse operation in both directions with pulse storage 15.3 Permanent release in both directions 15.4 Pulse operation in one direction, permanent release in the other direction Recommendations Recommendation 89/392/EWG of 14.06.89 incl. modifications up to 93/68/EWG of 22.07.03 Recommendation 73/23/EWG of 19.02.73 incl. modifications up to 93/68/EWG of 22.07.03 Recommendation 89/336/EWG of 03.05.89 incl. modifications up to 93/68/EWG of 22.07.03 DIN VDE 0113 T1 06.93 (EN 60204-1-1992, IEC 204-1-1992) DIN EN 292 T2 11.91 581E,5811 10.03_MPT 33 22