Operating Instructions Type MPT 53

Similar documents
Operating Instructions Pedestrian Turnstile Type MPT 33

(1032 mm) 30.5 (775 mm) 44 ( mm)

5600 Series Power Operator Installation and Instruction Manual

Solenoid Valves Type 3963

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

91 (2311 mm) (1581mm) (1375 mm)

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

RotaSec FOS. Manual Full-Height Turnstile for External Installation. Passage in both directions is electronically controlled.

RotaTech FH Manual Security Turnstile

RevoSec. Manual Full-Height Turnstile for Internal Installation. Passage in both directions is electronically controlled.

RevoSec. Manual Full-Height Turnstile for Internal Installation. Passage in both directions is electronically controlled.

2904 Power Supply Installation Instructions I-EA00041

SlimStile EV. Tripod Turnstile for Internal or External Installation (*)

MST. model. alvaradomfg.com

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

BMRX Series Rotary Level Indicator

RevoSec. Manual Full-Height-Turnstile for Internal Installation

EDC-E. Waist HIGH Turnstiles. alvaradomfg.com

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

MST. Full Height Turnstiles. alvaradomfg.com

SlimStile EV. Tripod Turnstile for Internal or External Installation*

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

BMRX Series ROTARY LEVEL CONTROL

Sliding Gate Operator User's Manual

RevoSec. Manual Full-Height Turnstile for Internal Installation

Sliding Gate Operator User's Manual

Combined Ventilation Controller RVWS-T-224HA

Continuous level measuring system NB 4000 Selection list

User Manual Rittal PMC UPS 6kVA

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Continuous level measuring system NB 3000 Selection list. Overview

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

GTK 80. Technical data

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

BR230 MOTORIZED VIP. OPERATION and MAINTENANCE MANUAL

Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

TURNSTILES GA2-TM-(DA) CATALOGUE GASTOP PREMIUM

AIS and 40 kva 400 V. Site Preparation and Installation Manual

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

/ S. Warhawk Road, Conifer, CO /

X-JET (Counter current system)

Continuous level measuring system NB 3000 Selection list

Instruction Manual for the. E-SL 450 Series

Powerware Vdc Extended Battery Cabinet User s Guide.

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

VERG 24V BARRIER. English

University of Houston Master Construction Specifications Insert Project Name

RP-4000 Reserve Power Control

Operating Instructions

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

Model Specifications Code Price FOTOSWITCH

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Note - Head mechanism fail state will be the same as power failure choice.

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Electric Vehicle Charging Station

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Operating manual UPS - System

Level limit switch Series RF 3000 Selection list

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Solenoid interlock AZM 200 The non-contact interlock.

PSM72H Push-Button Start Module

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

X JET (Counter current system) Instruction Manual

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

N/** поставка оборудования для подготовки воздуха

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Operating Instructions CYR52

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications

Series 3730 Electropneumatic Positioner Type

Enelion Vertica. Installation manual. 22 kw. for the specialists

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Product facts Geryon SRD Security Revolving Doors STS Security Turnstiles

Sentinel Field Satellite Controller

CVR-625. Compact Vibrating Rod Instruction Manual

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Emergency lighting units EM LED Light Engines

WELDING POSITIONER S OPERATION MANUAL CWP40

Sentry Battery Charger. Installation and Operations Manual Section 75

ACROBAT SWING STAND MODEL

HS6B Series Subminiature Interlock Switch

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Submersible Pumps Model ST4125D Model ST6125D

USER INSTRUCTIONS FOR SLIDING DOORS

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Transcription:

Operating Instructions www.turnstiles.us Type MPT 53 Contents 1. Delivery... 2 2. Safety...3-4 3 Description and operation... 5 4. Technical Data 6 5. oundation...6-9 6. Assembly and installation...10-13 7. Electrical connection...14-15 8. Access control devices... 16 9. Commissioning... 17 10. Technical support... 17 11. Spare parts and accessories...17-18 12. Warranty... 19 13. Controller MSC 10...... 20-22 581E,5813 06.06_MPT 53_0 1

1. Delivery The Security Turnstile consists of: In addition to the items shown in the drawing below, we also provide the following parts: 1 x Set of installation manuals 2 x Keys for Access door 581E,5813 06.06_MPT 53_0 2

2. Safety 2.1 General safety notes www.turnstiles.us pedestrian turnstile has been designed, built, and tested according to the latest available technology. The product has left the factory in a fully operational and safe condition. However, it is imperative that the installation is carried out in accordance to this operating manual. Therefore, it is vital to read this operating manual in full before starting the installation and that all the safety notes and remarks are being observed. Any liability and warranty is declined by the manufacturer in the case of incorrect use and use for purposes other than intended by the design. 2.2 Intended Use www.turnstiles.us pedestrian turnstile MPT* shall only be used to control pedestrians entering or exiting restricted areas. www.turnstiles.us Universal Controller MUC* shall only be used for controlling the pedestrian turnstile MPT*. Any other use is not permitted. Conversions and modifications to the turnstile or to the control modules are not permitted. Only original spare parts and accessories from www.turnstiles.us shall be used. 581E,5813 06.06_MPT 53_0 3

2.3 Identification of risks/saty Possible risks are identified with the following symbols in the operating instructions: Warning! This symbol is used in this manual to warn installers of potential harm. Please read and observe these instructions very carefully. Caution! This symbol is used in this manual to highlight those actions or states, which represent a potential hazard to pedestrian, personnel, property, and equipment. Please read and observe these instructions very carefully. Note! This symbol is used in this manual to highlight useful information for the operator and installer. Please read and observe these instructions very carefully. 2.4 Safety notes Disconnect all external opening or closing devices (remote control, control desk, etc.) during maintenance work Do not operate the equipment without effective anchoring to the oundation A main supply power circuit breaker must be installed This operating manual and any other additional information must be kept in a, for all authorized person, accessible location. Before commissioning make sure all electrical and functional features are tested. The electrical wiring must comply with this instructions. Only certified and trained electrical technicians shall perform any electrical work. Before any maintenance or troubleshooting work the main power supply must be disconnected. Electrical voltage components like transformers, solenoids, resistors, and stator housings of motors, lamps etc. may be hot during and after operation. Do not touch such components; it can cause skin burns 581E,5813 06.06_MPT 53_0 4

3. Product description The MPT series turnstiles are designed to control pedestrians entering or exiting restricted areas in high security applications. The turnstile consists of eight different components (see fig. 1). The unit can be set up for bidirectional access control by means of keys or card readers (access control devices in general). Entry and exit of the unit can either be operated in normally open or closed mode. The rotating centre column consists of 3 x 120 degree U-bars. The controller, the drive unit, and the locking device are installed inside the top powder coated sheet metal enclosure. The top enclosure provides efficient space for additional access control equipment. The locking and unlock feature of the turnstile is performed by the controller (MCU) and the electro-mechanical solenoid locking mechanism. ig.1 581E,5813 06.06_MPT 53_0 5

4. Technical Data Technical Data: Type MPT 53 Protection IP Voltage VAC requency Hz Current A Duty Cycle % Weight lbs Height Inch Width Inch 54 115 60 5,0 100 700 88 87 5. oundation The foundation shall be constructed with at least 2500 PSI grade concrete. The mounting surface must be leveled to insure a solid base for the turnstile. Once the concrete has set to an adequate hardness, the holes for the anchor bolts can be drilled using the dimensions shown in ig. 2. www.turnstiles.us recommends using 3/8 anchor bolts. Please refer to the anchor bolt manufacturers installation requirements. or the dimensions, please refer to figure 2. The cables should finish a minimum of 15 ft above the concrete surface. NOTE: This foundation is also required when installing the turnstile on pavers. See instruction for installation with pavers. Conduit pipes (with different diameters for low and high voltage cables as per Electrical code) must be installed to run the mains supply cable and the control cables. The conduits must reach at least 2 above ground. 581E,5813 06.06_MPT 53_0 6

2400 2124 1515 712 120 60 Passage direction Passage direction 1233 60 empty pipe bearing bearing 120 1238 1500 empty pipe ig. 2 Passage direction Passage direction Cut B-B oundation, smoothed finish to be positioned in water in a level and horizontal manner Lay seperate conduits for power supply and data cables, 50 mm approx. above foundation All power supply and data lines are to be 5 m at least above the empty conduit A A Concrete PC 250 with iron reinforcement empty conduit O 25 mm After mounting glue set screw with LOCTITE 241 or similar srew split washer washer socket bearing neck washer bearing 581E,5813 06.06_MPT 53_0 7

5.1 oundation frame The foundation frame is required for turnstiles to be mounted on sub ground, for example in case of pavers. A level concrete mounting surface is required for correct mounting of the foundation frame. It should be approx. 6 Inches below the finished surface. Mounting of the foundation frame: - Make sure to position the frame in the correct place - drill of holes for anchor bolts - install anchors, - level the foundation frame before tightening the bolts - tighten the foundation frame. Anchor () Express-Anchor M12x153/55 A4 Bore hole Ǿ12 Depth 145 mm incl. height of U-Profile ig.4 Cable routing from foundation into turnstile Jackscrews or positioning the foundation rame on the concrete, if necessary. 581E,5813 06.06_MPT 53_0 8

6. Assembly and installation 6.1 Installation (above ground foundation) Position the cage parts at its desired location based on the previously installed anchor bolts. Mount the components in correct order (part 1, 2..) onto the foundation; however, do not fully tighten the bolts until all components are in place. This is to compensate for tolerances from the steel manufacturing and anchor position. part 3 part 4a part 2 part 1 part 5 part 2 part 4a Part 1 ig.5 Place part 3 on top of part 1 and 2. Use screws 8 x M12 x 35 and counter nut. Mount lower bearing (see fig. 8). Using screws M10 x 70. Make sure to lubricate the bolts when installing. Slide part 4 onto lower bearing, see fig. 9. then attach the center column to the upper mechanism by making use of the 4 x M16 x 40 and washers. Make sure that the turnstile is in a locked position. Now tighten all existing bolts. 581E,5813 06.06_MPT 53_0 9

6.2 Installation using the oundation rame See section 5.1 oundation frame In this case the turnstile is mounted on the flanges of the foundation frame. 6.3 Opening of the top cover The top cover is locked in place via 4 hexagon socket head screws. Unscrew the fasteners with an Allen key. (fig. 6). ig.6 Tilt the top cover away from you. 581E,5813 06.06_MPT 53_0 10

6.4 Placing the components All cage components are installed to the foundation by using the 8x M8 bolts and washers that came with the shipment. After final positioning, tighten all bolts firmly. ig. 7 6.5 Installing the center column ig. 8 581E,5813 06.06_MPT 53_0 11

ig. 9 Mount the lower bearing on the foundation and slide the centre column over it. ig. 10 Attach the center column using the provided 4x M16 bolts and washers to the flange of the upper mechanism. Make sure the center is in correct position (center in locked position). 581E,5813 06.06_MPT 53_0 12

7. Electrical Wiring Any electrical wiring has to be done by a certified electrician in accordance with local electrical codes and the provided wiring diagram. ig.11 Main power connection ig. 11 ig.12 581E,5813 06.06_MPT 53_0 13

7.1 Wiring Diagram MSC - 10 counter passage left passage right alarm X17 X18 X19 X20 X21 X22 X23 X24 X25 X26 X27 X28 X29 X30 K1K K2K K3K K4K K5K not occupied 24V / 400mA +10%/ -20% 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 MSC Alarm RS232 ON O 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 n.c. 19VAC or 24VDC PE 24V 24V Sol. left Sol. right IN1 = opening left IN2 = opening right IN3 = emergency release IN4 = reserve IN5 = limit switch left IN6 = limit switch right IN7 = reserve IG.13 581E,5813 06.06_MPT 53_0 14

8. Housings / Access Control Panels ig.14 ig. 14 shows the provided access control panel. ig. 15 Rear view of the access control panel The control wiring from the access control device can be fed through the tubing by drilling a hole in the shown position. ig.15 581E,5813 06.06_MPT 53_0 15

9. Commissioning Once all electrical and mechanical installation have been completed and checked for errors, the turnstile can be set into service. Check before start-up that all assembly and installation instructions have been followed and the electrical connections have been performed correctly. Warning: Any electrical wiring shall only be performed by a certified electrician and must conform with existing local codes and in accordance with this operating manual. Operation of the Turnstile The Turnstile is generally operated by an access control system or control switches. 10. Technical Support Should problems occur please contact an authorized after sales service representative. Please refer to the nameplate on the turnstile housing for the data required in the case of queries. 11. Spare parts and accessories See igure 16 for the exploded drawing, which details the individual parts and their identification numbers. 581E,5813 06.06_MPT 53_0 16

Spare parts 1008,5000 (RAL7042) 1008,5009 (V2A) 1008,5010 (V4A) (--> 5547,5018) 2059,5051 (verzinkt) 2059,5061 (RAL7042) 2059,5052 (V2A) 2059,5053 (V4A) 1031,5289 (230V) 1031,5284 (115V) 1031,5285 (230V) (--> 5547,5015) 1031,5286 (115V) (--> 5547,5017) 1056,5062 3469,5022 (3x) 2032,5019 (8x) 5 2018,0332 1056,5062 2059,5057 (verzinkt) 2059,5060 (RAL7042) 2059,5058 (V2A) 2059,5059 (V4A) 2017,5025 (3x) 3576,5020 2058,5017 (verzinkt) 2058,5020 (RAL7042) 2058,5018 (V2A) 2058,5019 (V4A) 3576,5020 2043,5258 (verzinkt) 2043,5261 (V2A) 2043,5260 (V4A) 2046,5004 2017,5026 2043,5265 (verzinkt) 2043,5266 (V2A) 2043,5267 (V4A) 2059,5045 (verzinkt) 2059,5050 (RAL7042) 2059,5047 (V2A) 2059,5046 (V4A) 2046,5004 2017,5026 2059,5045 (verzinkt) 2059,5050 (RAL7042) 2059,5047 (V2A) 2059,5046 (V4A) 2059,5054 (verzinkt) 2059,5062 (RAL7042) 2059,5055 (V2A) 2059,5056 (V4A) ig.16 581E,5813 06.06_MPT 53_0 17

12. Warranty www.turnstiles.us provides a limited warranty on its turnstiles that covers all mechanical and electrical components, but excludes parts subject to wear and tear, for a period of two years from the date of first use or for a maximum of three years from the date on which the system was delivered provided that the operating instructions have been complied with, no unauthorized servicing of machine components has taken place, and that no mechanical damage to the machines is evident. Please refer to our standard Warranty Statement. 581E,5813 06.06_MPT 53_0 18

13. Control Unit MSC 10 unctions 13.1 unctions of digital inputs Input 1 terminals X21 / X22 = Opening of passage direction left Opening pulse passage left (entry). Input 2 terminals X24 / X 25 = Opening of passage direction right Opening pulse passage right (exit) Input 3 IN3, terminal 11 = input emergency situation In case of emergency passage free in both directions. 13.2 unction of semi conductor outputs Output 1 terminal X6 = solenoid left Output 2 terminal X7 = solenoid right Output 3 terminal X8 = reserve 13.3 unction of relay outputs Relay 1 = counter pulse left terminal X18 If the end position in passage direction left is reached a counter pulse of 300 ms is given. This applies to permanent release also. Relay 2 = counter pulse right terminal X19 If the end position in passage direction left is reached a counter pulse of 300 ms is given. This applies to permanent release also. Relay 3 = Display passage free left terminals X22 + X21 In case of free passage left a permanent signal is given. This output can also be used to lock a pulse transmitter for passage right if passage left is given free. Relay 4 = Display passage free right terminals X 24 + 25 In case of free passage right a permanent signal is given. This output can also be used to lock a pulse transmitter for passage left if passage right is given free. Relay 5 = Error-/Alarm output terminal X27 In case of certain errors, a permanent signal is given as long as the error is not eliminated. Relay 6 = Reserve 13.4 Safety functions In case of an error in the microcontroller the watchdog, function releases a hardware reset. 581E,5813 06.06_MPT 53_0 19

14. Adjustable parameters The following parameters can be adjusted using the controllers DIP switches and rotary switch: DIP unction O ON 1 Barrier type MPT MPP 2 Pulse storage Off On = 4 pulses per direction 3 Locking delay time Off On = 1 sec.approx. 4 Hardware tests *) *) 5 Hardware tests *) *) 6 Solenoid left Normal inverted 7 Solenoid right Normal inverted 8 Opening duration via LEDs No display display DIP 1 Selection of barrier type One of the following barrier types must be selected: - MPP - MPT Currently, this feature is set so that both position will work with the MPT. DIP 2 Pulse storage When this function is turned off the MPT allows only one opening pulse at a time. Meaning, after each opening pulse the patron has to walk through the turnstile or the opening time has to elapse in order for the unit to accept the next signal. If turned on the unit stores the opening signals (up to 4 per direction) and the MPT decrements the counts after each turn. Therefore, a faster throughput can be achieved. DIP 3 Locking delay time In order to avoid a rotation of more than 120 in case of permanent release or several stored pulses a locking delay time can be activated via a dipswitch. The turnstile is then locked for 1 sec. after each 120 rotation (one person goes through) and will then be released for the next transaction. DIP 6 Solenoids Via DIP 6 and DIP 7 the function of both solenoids can be inverted separately for both directions. This depends on whether the turnstile is set up as open or closed when power fails. DIP 6 change the left solenoid output and DIP 7 the right one. 581E,5813 06.06_MPT 53_0 20

15 Operating modes 14.1 Pulse operation in both directions without pulse storage 14.2 Pulse operation in both directions with pulse storage 14.3 Permanent release in both directions 14.4 Pulse operation in one direction, permanent release in the other direction Certification Recommendation 89/392/EWG of 14.06.89 incl. modifications up to 93/68/EWG of 22.07.03 Recommendation 73/23/EWG of 19.02.73 incl. modifications up to 93/68/EWG of 22.07.03 Recommendation 89/336/EWG of 03.05.89 incl. modifications up to 93/68/EWG of 22.07.03 DIN VDE 0113 T1 06.93 (EN 60204-1-1992, IEC 204-1-1992) DIN EN 292 T2 11.91 581E,5813 06.06_MPT 53_0 21