Low Voltage Products. Breakers and Switches for the HVAC segment

Similar documents
Disconnect switches Non-fusible Fusible Enclosed

Low Voltage Products. Enclosed switches. Brochure OT_KSE 1 GB 05_02 1SCC340007C0201

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Switch-disconnectors OT , OETL 3150

AF40... AF96 3-pole contactors Technical data

Enclosed switches and safety switches Main Catalogue. 2CMC341002D0002 January 2009

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Enclosed DC rated switch-disconnectors OTDCP from 16 to 32 Amperes

Reliable in extreme conditions

PowerLine OS Switch Fuses A, 690V

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Breakers and Switches. Enclosed switches Safety switches A

Low Voltage Products. Switches Switch-disconnectors OT and OETL

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Softstarter Intelligent Controllers

Selection Guide Motor Control Device Solutions

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Motor Starting Solutions Open Type Version, in Kit Form

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Manufacturer Item Number Item Description QTY Available ABB 1SAM250000R1007 MS , THERMAL AND ELECTROMAGNETIC TRIP 5 ABB

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Item Code Description Quantity 1SAZ211201R1028 TA25-DU 2,4A THERMAL O/L ( ) 1 1SAZ211201R1043 TA25-DU-11A-THERMAL-OVERLOAD 0

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Motorized switch-disconnectors OTM 40 to 125 Amperes

AC Switches: ML & MN Series DC Switches: MDC1A Series

for Non-Fusible Disconnect Switches

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

UL 98 Fusible Disconnect Switches

D509E. Manual Motor - Starters

Selection Guide. Control Circuit and Load Protection

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Wall mounted switchgear

Short form catalogue. Motor protection & control

Enclosed Full-Voltage Starters

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

IEC Contactors & Starters XT IEC Power Control

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Enclosed Full-Voltage Starters

Low voltage switch gear

Manual motor starters Overview and benefits

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Preliminary - 1SDC210003B0201. New Tmax T4-T5. T Generation.

XT IEC Power Control Manual Motor Protectors

US Catalog. Motor protection and control AF Range contactors & overload relays

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR

Thermal overload relay TF140DU and TF140DU-V1000

Air-insulated switchgear UniGear type ZS1

Electronic overload relays EF205 and EF370

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

SD Series Non-Fused Load Switches

Brocure panorama. Switches for photovoltaic applications Disconnect switches OTDC and OTDCP

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Components for EEx e Panels

Enclosed Switches and Safety Switches

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Breakers and Switches. Switches Change-over and transfer switches

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Application Description

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

for Non-Fusible Disconnect Switches

SECTION MOTOR CONTROL

DPX earth leakage DPX 3 -I earth leakage

for Non-Fusible Disconnect Switches

ABB s new control and protection devices

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Micro Contactor MA Series

The complete offer Enclosed switch-disconnectors / Isolators

Motor protective circuit breakers

Motor Protection Circuit Breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

UL/CSA Non-fused Disconnect Switches

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

3 - Protection components Motor circuit-breakers

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Product Specification Sheet #3LD2.1

1SDC210015B0203. Tmax. T Generation.

DPX Magnetic only

Softstarters Type PSS. Softstarters. General information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

Section Contents. Disconnect Switches

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

ICG Switchgear Price List 2009

Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products

Low Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd.

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Transcription:

ow Voltage Products Breakers and witches for the VAC segment

ABB s extensive range of products for the VAC segment ABB s very extensive range of appliances and systems for low voltage power distribution includes a large selection of products for process control, protection and automation. In many countries, for example in the United tates, air conditioning accounts for over 40 percent of power consumption and, in general, motors use the most electrical power in starting, running and stopping fans, compressors and pumps. ABB s products for air conditioning applications include main switches, drives, components for motor starters and control panels and disconnect switches for isolation. Depending upon the application for which the equipment is to be used, ABB products are compliant with major international standards, in particular those in force in Europe (IEC) and orth America (U). ABB products are also used in industrial air filtration solutions world wide. Main switch applications witch-disconnectors and breakers are typically used in isolating individual sections of the plant or as the main switch for the whole VAC system, both AC and DC. ABB s breakers and switches are compact in size, have high ratings, unique safety features and global availability and acceptability. ABB switch-disconnectors range from 16 to 3150 amperes and the breakers from 20 to 2500 amperes in AC-23 switching categories. Motor starter applications Our switch-disconnectors and breakers are used in motor starter applications for switching and isolating. Together with contactors, thermal overload relays and fuselinks they also provide protection against overloads and short circuits. The circuit breakers are designed for starting, switching and protecting three-phase asynchronous motors. ABB proposes two different solutions for this type of application: a traditional system, with a circuit breaker for protection against short circuit, a thermal relay for protection against overload, missing or unbalanced phase and a contactor for motor switching a system of integrated protection with the PR222MP trip unit, which ensures both protection against short circuit and overload, as well as against missing or unbalanced phase and against rotor block Isolation applications ocal safety switches can be enclosed in plastic or metal enclosures for outdoor use up to protection class IP65. These products are typically used during maintenance to isolate individual sections or the whole system and mechanically secure the switch in open position by using padlocks. The ABB portfolio also includes cam switches The rotary cam switch range for control, instrumentation and motor starting applications provide you with a variety of functionalities for the most common mounting types with minimum footprint area. The range covers a variety of applications, from O-OFF, change-over, and multi-step to volt-ammeter, bypass, and UP. As the leading manufacturer of switch products, our vision, in cooperation with our customers and partners, is to further develop cost saving and environmentally safe solutions for the equipment used in the VAC segment in order to meet new needs and technical requirements. 2 ow Voltage Products Breakers and witches for the VAC segment

Enclosed switch-disconnectors provide the right solution in the power range 7.5 800 kw/690 V, AC-23A The enclosed switches are suitable for power distribution in factories and buildings, as local motor isolators or main switches. Each incoming supply shall be provided with a hand operated main switch-disconnector according to the machine directive E 60204 and isolate the electrical equipment reliably from the supply. To meet these requirements the enclosures have handles that can be locked with padlocks in the OFF-position. The wide range of switch-disconnectors are available in plastic, steel sheet, stainless steel sheet and aluminum alloy enclosures from 16 to 1600 amperes. The most compact disconnect switch solution from 16 to 3150 amperes The switch-disconnector is largely used as the main switch in low voltage switchgears for distribution of power, starting and stopping motors and isolating loads during maintenance. The range from 16 to 160 amperes is either base plate or door mounted by snap-on or screw fitting. Front operated 3-, 4-, 6-, 8-pole and change-over types are available as standard. From up to 3150 amperes the switch-disconnectors are designed as pole modules and they are available as 1- to 4-pole versions, front or side operated and change-over switches. For fusible short circuit protection switch fuses are available for DI, B, FC, U and CA types of fuse links from 16 to 1250 amperes. Circuit breakers designed for protecting motors from 0.37 kw up to 355 kw in very compact sizes Two different protection solutions: traditional or integrated Advanced electronic protection units are available Exellent coordination with A and AF series ABB contactors and with ABB thermal release Wide choice of terminals and accessories Breakers and witches for the VAC segment ow Voltage Products 3

afety switches from 16 to 90 A Ratings according to IEC60947-3 00696A OTP16T_ OTP25T_ 00692A OTP75T_ OTP36T_ OTP63T_ OTP90T_ Plastic enclosed front operated safety switches, IP65 The safety switch comes complete with a black selector type handle (I-O, O-OFF), PE and terminals and one O auxiliary contact. Knock-out openings with metric thread, also for control cables. Compression glands must be ordered separately. Max motor output Cable outlets/ Dimensions AC-23A side 230 V 400 V 690 V W D 3 pole 4 pole (mm) (mm) (mm) 5.5/23 7.5/16 7.5/10 2xM25+M16 130 150 60 OTP16T3M OTP16T4M 7.5/30 15/30 15/20 2xM32+M16 145 90 OTP25T3M OTP25T4M 11/38 22/38 15/20 2xM32+M16 145 90 OTP36T3M OTP36T4M 18.5/63 30/63 30/35 2xM32+M16 145 90 OTP63T3M 22/80 37/80 37/40 2xM50+M16 400 140 OTP75T3M OTP75T4M 22/90 45/90 45/50 2xM50+M16 400 140 OTP90T3M OTP90T4M 2CMC341011F0054 Plastic enclosed side operated safety switches, IP65 The safety switch comes complete with PE and terminals and one O auxiliary contact, cable entries with metric threaded knock-outs, IP 54 membrane glands/sealing plugs. For IP65 protection, compression glands must be used. BW316TP BW416TP 2CMC341011F0056 BW325TP BW425TP Max motor output Cable outlets/ Dimensions AC-23A side 230 V 400 V 690 V W D 3 pole 4 pole (mm) (mm) (mm) 7.5/16 7.5/10 2xM25/2xM25 111 130 60 BW316TP BW416TP 11/25 11/16 2xM32/2xM32+1xM16 138 168 68 BW325TP BW425TP teel sheet enclosed front operated safety switches, IP65 The safety switch comes complete with a black selector type (OT16 63) or pistol type (OT75 90) handle (I-O/O-OFF), one O auxiliary contact and PE terminal. Cable entries from bottom (OT16...63) or from top and bottom (OT75...90). Compression glands and flanges must be ordered separately. 01211A OT16...63T_ Max motor output AC-23A 230 V 5.5/23 7.5/30 11/38 18.5/63 22/80 22/90 400 V 7.5/16 15/30 22/38 30/63 37/80 45/90 690 V 7.5/10 15/20 15/20 30/35 37/40 45/50 Cable outlets Dimensions 1xB flange 1xB flange 1xB flange 1xB flange 2xB flange 2xB flange W (mm) 150 150 150 150 (mm) 300 300 D (mm) 135 135 3 pole OT16T3B OT25T3B OT36T3B OT63T3B OT75T3B OT90T3B 4 pole OT16T3B OT25T3B OT36T3B OT63T3B OT75T3B OT90T3B 01251A OT75...90T_ For more information regarding aluminum and stainless steel enclosures, EMC protected types and sizes up to 1 kw/1250 A and accessories see the technical catalogue OT2GB_ 4 ow Voltage Products Breakers and witches for the VAC segment

cuus approved safety switches from 16 to 80 A Ratings according to cuus 508 uitable as motor disconnect Plastic enclosed front operated disconnect switches The disconnect switch include a black rotary operated selector (EMA3R/12) or pistol type (EMA4/4X) handle (I-O,O-OFF) and one O auxiliary contact. EMA 3R/12 6/15.2 10/28 15/42 20/54 Max horsepower/amp rating Three phase ingle phase 480 V 10/14 20/27 30/40 40/52 600 V 10/11 25/27 30/32 40/41 120 V 1/6 2/13.2 5/30.8 7.5/40 10/57.5 U G. P. amp rating 16 40 60 80 W (mm/in) /3.94 /3.94 146/5.75 210/8.27 Dimensions (mm/in) 140/5.51 140/5.51 176/6.93 300/11.81 D (mm/in) 81/3.19 81/3.19 103.5/4.07 136/5.35 3 pole 4 pole EOT16U3P3-1 EOT16U4P3-1 EOT32U3P3-1 EOT32U4P3-1 EOT45U3P3-1 EOT45U4P3-1 EOT63U3P3-1 EOT63U4P3-1 EMA 4/4X 6/15.2 10/28 15/42 20/54 Max horsepower/amp rating Three phase ingle phase 480 V 10/14 20/27 30/40 40/52 600 V 10/11 25/27 30/32 40/41 120 V 1/6 2/13.2 5/30.8 7.5/40 10/57.5 U G. P. amp rating 16 40 60 80 W (mm/in) /3.94 /3.94 146/5.75 210/8.27 Dimensions (mm/in) 140/5.51 140/5.51 176/6.93 300/11.81 D (mm/in) 81/3.19 81/3.19 103.5/4.07 136/5.35 3 pole 4 pole EOT16U3P4-1 EOT16U4P4-1 EOT32U3P4-1 EOT32U4P4-1 EOT45U3P4-1 EOT45U4P4-1 EOT63U3P4-1 EOT63U4P4-1 Breakers and witches for the VAC segment ow Voltage Products 5

witch-disconnectors from 16 to 1600 A Ratings according to IEC60947-3 04049 OT16-40F3 Front operated switch-disconnectors s OT 16...160 for base and DI rail mounting, OT16 160 include protected terminal clamps. hafts and handles have to be ordered separately up to OT125. s OT160...1600 include a black O-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the O-position. 04051 00464B 02101A OT - 125F3 OT160E3 OT - 250E03P 220-3/16 4/20 5.5/23 11/45 22/75 22/80 22/90 45/135 60/ 75/250 /315 132/400 /630 250/800 250/800 310/0 310/1 Max motor output AC-23A 400-415 V 7.5/16 9/20 5.5/23 22/45 37/75 37/80 45/90 75/135 110/ 140/250 160/315 220/400 355/630 450/800 450/800 560/0 560/0 440 V 7.5/16 9/20 5.5/23 22/45 37/65 37/65 45/78 75/125 110/ 145/250 180/315 230/400 355/630 450/800 500/800 630/0 630/0 500 V 7.5/16 9/20 5.5/23 22/45 37/58 37/60 45/70 75/125 132/ 170/250 220/315 280/400 400/630 560/800 560/800 710/0 710/0 690 V 7.5/10 9/11 11/12 15/20 18.5/20 37/40 45/50 75/80 / 259/250 315/315 400/400 630/630 800/800 800/800 800/800 800/0 Rated thermal current (A) 25 32 40 63 80 115 125 250 315 400 630 800 0 1250 1600 3 pole 4 pole OT16F3 OT16F42 OT25F3 OT25F42 OT40F3 OT40F42 OT63F3 OT63F42 OT80F3 OT80F42 OTF3 OTF42 OT125F3 OT125F42 OT160E3 OT160E4 OTE03P OTE04P OT250E03P OT250E04P OT315E03P OT315E04P OT400E03P OT400E04P OT630E03P OT630E04P OT800E03P OT800E04P OT0E03P OT0E04P OT1250E03P OT1250E04P OT1600E03P OT1600E04P 02105A OT630-800E03P More information for door mounted versions, accessories and sizes up to 3150 A in the technical catalogue OT_OET1GB_ KE00046 OT1600E03P 6 ow Voltage Products Breakers and witches for the VAC segment

on-fusible disconnect switches from 16 to 1 A Ratings according to cuus 508 and cuus 98 04049 OT16-40F3 Front operated, non-fusible disconnect switches s OT 16...160 for base and DI rail mounting, OT16 160 include protected terminal clamps. hafts and handles have to be ordered separately up to OT. s OT160...1 include a black O-OFF plastic handle and shaft as standard. The handle is EMA 1, 3R/12 protected, padlockable in the OFF-position and with door interlock in the O-position. The shaft is adjustable for a range of installation depths. 01632A 04053 KE00046 02105A OT30, 60, F3 OTU03P OT600U03P Approved according to cuus 508 5/15.2 7.5/22 10/28 15/42 20/54 Max horsepower/amp rating 480 V 10/14 15/21 20/27 30/40 40/52 600 V 15/17 20/22 25/27 30/32 40/41 Approved according to cuus 98 10/28 20/54 30/80 40/104 75/192 125/312 /480 250/602 Three phase 120 V 1/16 1.5/20 Max horsepower/amp rating Three phase 480 V 20/27 40/52 50/65 75/96 150/180 250/302 450/515 500/590 600 V 30/32 40/41 50/52 /99 /192 350/336 500/472 500/472 ingle phase 2/13.2 3/18.7 5/30.8 7.5/40 10/57.5 ingle phase 120 V 3/34 5/56 7.5/80 5/28 7.5/40 15/68 20/88 General purpose amp rating A 20 30 40 60 80 General purpose amp rating A 30 60 125 400 600 800 1 3 pole OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 3 pole OT30F3 OT60F3 OTF3 OT160E3 OTU03P OT400U03P OT600U03P OT800U03P OT1U03P 4 pole OT16F42 OT25F42 OT40F42 OT63F42 OT80F42 4 pole OT30F42 OT60F42 OTF42 OT160E4 OTU04P OT400U04P OT600U04P OT800U04P OT1U04P More information for door mounted versions, accessories and sizes up to 3150 A in the technical catalogue OT_OET1GB_ OT800-1U03P Breakers and witches for the VAC segment ow Voltage Products 7

witch fuses from 16 to 1250 A Ratings according to IEC60947-3A 01382A Front operated switch fuses, DI 63620 types Including terminal bolt kit (O125...1250), a black O-OFF plastic handle and shaft as standard. The handle is IP65 protected, padlockable in the OFF-position and with door interlock in the O-position. The shaft is adjustable for a range of installation depths. 00799A 01129A O40FD10 O32-63D12 230 V 11/40 7.5/32 18.5/63 37/125 45/160 60/ 75/250 132/400 /630 250/800 315/0 315/0 Max motor output AC-23A 400 V 500 V 18.5/40 22/40 15/32 18.5/32 30/63 37/63 55/125 75/125 75/160 90/160 110/ 132/ 140/250 170/250 220/400 280/400 355/630 450/630 450/800 560/800 560/0 710/0* 560/0 710/0* 690 V 30/40 22/32 45/63* 110/125* 132/160* / 250/250 400/400 630/630 710/800 0/0* 0/0* Rated thermal current (A) 40 32 63 125 160 250 400 630 800 1250 1250 Fuse size 000 000, 00 000, 00 000, 00 000, 00 0 0, 1 0, 1, 2 3 3 4 4a 3 pole 4 pole O40FD10 O40FD201 O32D12 O32D221 O63D12 O63D221 O125D03 O125D042 O160D03 O160D042 OD03P OD042P O250D03P O250D042P O400D03P O400D042P O630D03P O630D042P O800D03P O800D042P O1250D03P O1250D042P O1250DA03P O1250DA042P * Utilization category B O125-160D03 02107A OD03 For more information and accessories see the technical catalogue O1GB_ KE00036 O630D03 8 ow Voltage Products Breakers and witches for the VAC segment

Fusible disconnect switches from 30 to 1 A Ratings according to cuus 98 01133A 00799A 01125A O30FA_12P O60J12P OJ03P Front operated fusible disconnect switches Including terminal bolt set from A and up, a black O-OFF plastic handle and shaft as standard. The handle is EMA 1, 3R&12 protected, padlockable in the OFF-position and with door interlock in the O-position. The shaft is adjustable for a range of installation depths. Approved according to cuus 98 Max horsepower/amp rating General Three phase ingle phase 7.5/22 7.5/22 15/42 30/80 60/154 125.0/312 /480 250/602 480 V 15/21 15/21 30/40 60/77 125/156 250/302 400/477 500/590 600 V 20/22 20/22 50/52 75/77 150/144 350/336 500/472 500/472 120 V 3/17 3/17 purpose amp rating A 30 30 60 400 600 800 1 Fuse type, size CC, 30 A J, 30 A J, 60 A J, A J, A J, 400 A J, 600 A, 800 A, 1 A 3 pole O30FACC12P O30FAJ12P O60J12P OJ03P OJ03P O400J03P O600J03P O80003P O103P 4 pole O30FACC22FP O30FAJ22FP O60J22FP OJ04FP 04121 01835A 02160A OJ03P For more information and accessories see the technical catalogue O1GB_ O400J03P O103P Breakers and witches for the VAC segment ow Voltage Products 9

Motor protection circuit-breakers Ordering codes IEC ratings T2 160 Fixed (F) 3 Poles - Front terminals (F) 1DC210303F0004 In I 3 Magnetic only trip unit - MF and MA * ) Icu (415 V) 1 13 1.6 21 2 26 2.5 33 3.2 42 4 52 5 65 6.5 84 8.5 110 11 145 12.5 163 20 120...240 32 192...384 52 312...624 80 480...960 600...1 36 ka 053110 053111 053112 053113 053114 053115 053116 053117 053118 053119 053120 051207 051208 051209 051210 051211 50 ka 70 ka 053121 053132 053122 053133 053123 053134 053124 053135 053125 053136 053126 053137 053127 053138 053128 053139 053129 053140 053130 053141 053131 053142 051216 051224 051217 051225 051218 051226 051219 051227 051220 051228 85 ka 053143 053144 053145 053146 053147 053148 053149 053150 053151 053152 053153 051232 051233 051234 051235 051236 In Electronic trip unit Icu (415 V) PR221D-I PR221D-I PR221D-I PR221D-I PR221D-I PR221MP PR221MP PR221MP 10 25 63 160 40 63 ote: The trip coil of the T2 circuit-breaker with PR221D electronic trip unit is housed in the right slot. For T2 with PR 221D the following groups of auxiliary contacts are available: - 1DA053704R1 Aux-C 151-1Q-1Y - 1DA055504R1 Aux-C 2Q-1Y 36 ka 051163 051164 051165 051166 051168 065340 065341 065342 50 ka 051174 051175 051176 051177 051178 065343 065344 065345 70 ka 051184 051185 051186 051187 051188 065346 065347 065348 85 ka 051194 051195 051196 051197 051198 065349 065350 065351 T3 250 Fixed (F) 3 Poles - Front terminals (F) In I 3 Magnetic only trip unit - MA Icu (415 V) 600...1 125 750...1500 160 960...1920 1...2400 36 ka 051315 051316 051317 051318 50 ka 051320 051321 051322 051323 ote: T2, T4, T5 and T6 in three poles version equipped with PR221D-I electronic trip unit can be used for motor protection. * ) MF = Magnetic only trip unit with fixed magnetic thresholds MA = Magnetic only trip unit with adjustable magnetic thresholds 10 ow Voltage Products Breakers and witches for the VAC segment

Motor protection circuit-breakers Ordering codes IEC ratings T4 250 Fixed (F) 3 Poles - Front terminals (F) 1DC210305F0004 In I 3 Magnetic only trip unit - MA Icu (415 V) 10 60...140 25 150...350 52 312...728 80 480...1120 600...1400 125 750...1750 160 960...2240 1...2800 36 ka 055068 055069 055070 054296 054297 054298 054299 054300 50 ka 120 ka 055071 055074 055072 055075 055073 055076 054302 054308 054303 054309 054304 054310 054305 054311 054306 054312 In Electronic trip unit for motor protection Icu (415 V) PR222MP PR222MP 160 PR222MP 36 ka 054522 054523 054524 50 ka 120 ka 054525 054528 054526 054529 054527 054530 In Electronic trip unit Icu (415 V) PR221D-I PR221D-I 160 PR221D-I 250 36 ka 054000 054001 054002 50 ka 70 ka 054024 054048 054025 054049 054026 054050 120 ka 54072 54073 54074 V ka 054096 054097 054098 T4 320 Fixed (F) 3 Poles - Front terminals (F) In I 3 V Electronic trip unit Icu (415 V) 36 ka 50 ka 70 ka 120 ka ka PR221D-I 320 054118 054126 054134 054142 054150 ote: T2, T4, T5 and T6 in the three-pole version equipped with PR221D-I electronic trip units and T7 in the three-pole version equipped with PR231/P-I electronic trip units, can be used for motor protection. For more information following documents are available at http://bol.it.abb.com Technical catalogue T max T Generation QT7 Technical application papers Breakers and witches for the VAC segment ow Voltage Products 11

Motor control protection circuit breakers Ordering codes U/CA ratings T2 Fixed (F) 3 Poles U isted Iu (40 C) = A - Front terminals (F) 1DC210A09F0001 I 3 Magnetic only trip unit - MA Icu (480 V) 20 120 240 50 300 600 600...1 35 ka 055167 055168 055169 65 ka 055170 055171 055172 Electronic trip unit for motor protection Icu (480 V) PR221 D-I 25 PR221 D-I 60 PR221 D-I 35 ka 055463 055464 055465 65 ka 055466 055467 055468 T3 225 Fixed (F) 3 Poles U isted Iu (40 C) = 225 A - Front terminals (F) 1DC210304F0004 U 1DC210304F0004 U I 3 Magnetic only trip unit - MA Icu (480 V) 600...1 125 750...1500 150 900...1800 1...2400 Ts3 150 Fixed (F) 3 Poles U isted Iu (40 C) = 150 A - Front terminals (F) I 3 Magnetic only trip unit - MA Icu (480 V) 3 12...36 5 20...60 10 40...120 25...300 50...600 400...1 125 500...1500 150 600...1800 35 ka 054163 054164 054165 054166 25 ka 065391 065513 065514 065515 85 ka 065516 065517 065518 065519 12 ow Voltage Products Breakers and witches for the VAC segment

Motor control protection circuit breakers Ordering codes U/CA ratings Ts3 225 Fixed (F) 3 Poles U isted Iu (40 C) = 225 A - Front terminals (F) I 3 Magnetic only trip unit - MA Icu (480 V) 175 700...2 800...2400 65 ka 065520 065521 T4 250 Fixed (F) 3 Poles U isted Iu (40 C) = 250 A - Front terminals (F) 1DC210305F0004 U Electronic trip unit for motor protection Icu (480 V) PR221 D-I PR221 D-I 150 PR221 D-I 250 25 ka 059448 059449 059450 35 ka 65 ka 059451 059454 059452 059455 059453 059456 ka 59457 59458 59459 T5 400 Fixed (F) 3 Poles U isted Iu (40 C) = 400 A - Front terminals (F) Electronic trip unit for motor protection Icu (480 V) PR221 D-I 300 PR221 D-I 400 25 ka 059460 059461 35 ka 65 ka 059462 059464 059463 059465 ka 059466 059467 T5 600 Fixed (F) 3 Poles U isted Iu (40 C) = 600 A - Front terminals (F) 1DC210306F0004 U Electronic trip unit for motor protection Icu (480 V) PR221 D-I 600 T6 800 Fixed (F) 3 Poles U isted Iu (40 C) = 800 A - Front terminals (F) Electronic trip unit for motor protection Icu (480 V) PR221 D-I 600 PR221 D-I 800 25 ka 061851 35 ka 061656 061706 35 ka 65 ka 061852 061853 50 ka 65 ka 061703 061704 061707 061708 ka 061854 ka 061705 061709 For more information following documents are available at http://bol.it.abb.com Technical catalogue T max T Generation QT7 Technical application papers Breakers and witches for the VAC segment ow Voltage Products 13

Drives applications ABB switch-disconnectors and breakers are commonly used as main switch in drives applications. Together with the protection functions embedded in ABB standard drives for VAC applications they provide protection against several fault situations such as motor short circuit, overvoltage and overcurrent. In VAC applications, most of which are pumps and fans, AC drives can cut energy bills by as much as 80 percent. Power savings of up to 50 percent can be reached by reducing the motor speed by 20 percent. ABB has delivered millions of AC drives worldwide, cutting electricity consumption by about 140 TWh per year. This corresponds to an average reduction in CO 2 emissions of over 70 million tonnes every year. One of the biggest benefits of using ABB standard drives for VAC applications is the superior energy saving opportunity it creates compared to fixed speed motors or conventional flow control methods. Rather than have an electric motor running continously at full speed, an AC drive allows the user to variably control the motor speed, depending on the demand. 14 ow Voltage Products Breakers and witches for the VAC segment

Ordering information BW316 TP BW325 TP BW416 TP BW425 TP EOT16U3P3-1 EOT16U3P4-1 EOT16U4P3-1 EOT16U4P4-1 EOT32U3P3-1 EOT32U3P4-1 EOT32U4P3-1 EOT32U4P4-1 EOT45U3P3-1 EOT45U3P4-1 EOT45U4P3-1 EOT45U4P4-1 EOT63U3P3-1 EOT63U3P4-1 EOT63U4P3-1 EOT63U4P4-1 OJ03P OJ04FP O103P O1250D03P O1250D042P O1250DA03P O1250DA042P O125D03 O125D042 O160D03 O160D042 OD03P OD042P OJ03P O250D03P O250D042P O30FACC12P O30FACC22FP O30FAJ12P O30FAJ22FP O32D12 O32D221 O400D03P O400D042P O400J03P O40FD10 O40FD201 Order code 2CMA142417R0 2CMA142420R0 2CMA142418R0 2CMA142421R0 1CA022809R1560 1CA114773R1 1CA022863R7890 1CA114774R1 1CA022809R1640 1CA114782R1 1CA022863R8510 1CA114776R1 1CA103985R1 1CA114777R1 1CA114778R1 1CA114783R1 1CA114784R1 1CA114780R1 1CA114781R1 1CA114786R1 1CA022456R8810 1CA022508R2700 1CA105468R1 1CA105475R1 1CA105248R1 1CA105238R1 1CA105243R1 1CA022469R8780 1CA022507R3030 1CA022456R8310 1CA022507R2650 1CA022709R9500 1CA022709R9680 1CA022709R9760 1CA022719R0090 1CA022719R2380 1CA108817R1 1CA108821R1 1CA108828R1 1CA108831R1 1CA022456R9710 1CA022456R9890 1CA022719R0250 1CA022719R2460 1CA022719R1140 1CA108914R1 1CA108938R1 O600J03P O60J12P O60J22FP O630D03P O630D042P O63D12 O63D221 O800D03P O800D042P O80003P OT0E03P OT0E04P OTF3 OTF42 OT1U03P OT1U04P OT1250E03P OT1250E04P OT125F3 OT125F42 OT1600E03P OT1600E04P OT160E3 OT160E4 OT16F3 OT16F42 OTE03P OTE04P OTU03P OTU04P OT250E03P OT250E04P OT25F3 OT25F42 OT30F3 OT30F42 OT315E03P OT315E04P OT400E03P OT400E04P OT400U03P OT400U04P OT40F3 OT40F42 Order code 1CA022825R8870 1CA022434R8290 1CA022472R0460 1CA022825R2830 1CA022825R4290 1CA022434R7810 1CA022457R0040 1CA022825R4880 1CA022825R5180 1CA022825R9920 1CA022860R5930 1CA022860R6150 1CA105004R1 1CA105018R1 1CA022860R6910 1CA022860R7120 1CA022860R6230 1CA022860R6310 1CA105033R1 1CA105056R1 1CA022860R6580 1CA022860R6740 1CA022257R5950 1CA022259R8060 1CA104811R1 1CA104829R1 1CA022712R0800 1CA022713R4930 1CA022709R9920 1CA022710R0610 1CA022710R0 1CA022710R0520 1CA104857R1 1CA104886R1 1CA105068R1 1CA108347R1 1CA022718R8510 1CA022719R1730 1CA022718R8780 1CA022719R1810 1CA022718R9670 1CA022719R1900 1CA104902R1 1CA104932R1 OT600U03P OT600U04P OT60F3 OT60F42 OT630E03P OT630E04P OT63F3 OT63F42 OT800E03P OT800E04P OT800U03P OT800U04P OT80F3 OT80F42 OT16T3B OT25T3B OT36T3B OT63T3B OT75T3B OT90T3B OTP16T3M OTP16T4M OTP25T3M OTP25T4M OTP36T3M OTP36T4M OTP63T3M OTP75T3M OTP75T4M OTP90T3M OTP90T4M Order code 1CA022718R9830 1CA022719R2 1CA105076R1 1CA108348R1 1CA022718R8940 1CA022719R2030 1CA105332R1 1CA105365R1 1CA022718R9410 1CA022719R2110 1CA105665R1 1CA105667R1 1CA105798R1 1CA105413R1 1CA022571R9150 1CA022571R9230 1CA022571R9310 1CA022571R9400 1CA022546R0820 1CA022546R1120 1CA022400R9910 1CA022401R0500 1CA022401R0090 1CA022401R0680 1CA022401R0170 1CA022401R0760 1CA022608R2910 1CA022812R2890 1CA022812R3010 1CA022812R2970 1CA022812R3190 For breaker ordering, see pages 10 to 13 Breakers and witches for the VAC segment ow Voltage Products 15

Contact us ABB Oy ow Voltage Products P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 www.abb.com ABB ACE.p.A. ow Voltage Breakers Via Baioni, 35 I-24123 Bergamo, Italy Phone: +39 035 395 111 Fax: +39 035 395 306-433 www.abb.com The data and illustrations are not binding. We reserve the right to make changes in the course of technical development of the product. Copyright 9 ABB. All rights reserved. VAC10GB 09-09 1CC014B0201 Printed in Finland, 10-9/0, Waasa Graphics