CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

Similar documents
Cable Glands - American Series - NEC/IEC

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.

Certificate of Compliance

cable_glands_en.qxp :25 Uhr Seite 3 cable glands

ADE 6F ADE 6F. page 46

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

Global Cable Gland Solutions

Global Cable Gland Solutions

The safety you rely on.

Armoured / Un-armoured Cable Gland

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

ABG Cable Glands Installation Procedure

Capri ADE 6F - for Armoured Cable

Amphenol Cable Glands and Cord Grips Amphenol

Cable Connectors GET CONNECTED

New products Ex Equipment 2015

Self-Exciting Flameproof Alternator

Terminal Boxes Series 8252/1

Cable and Cord Fittings Hazardous and Non-Hazardous

sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands

Flameproof Alternators

As one of the leaders in cable management systems industry, MASEICO maintained the unique success by producing its developed range of cable glands.

HTSB system System overview

Terminal Boxes Series 8125

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Cable Glands for Hazardous Areas

Terminal Boxes Series 8125

IECEx Certificate of Conformity

Flameproof Alternator

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

E A E xe ENCLOSURES. For Harsh & Hazardous Environments.

Ex e, ia Junction boxes TNCN. Features

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

ADDIMAX CABLE GLANDS FOR INDUSTRIAL USE [ 2 ]

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

High voltage flameproof induction motors The simplest solution for hazardous environments

Operating Instructions

Zone 1 Linear Range - Installation Guide

Kopex-Ex cable glands offer superior protection in hazardous environments

It s time to get connected with

Floodlight Range Installation Guide

Glass Reinforced Polyester Enclosures

Enclosures. Section E

Flameproof Alternator

ADE5F. Inspectable Armour Cable Gland NEW! 2012 Eaton Corporation. All rights reserved.

BETA SWITCHES FOR HAZARDOUS AREA

Terminal Boxes in Stainless Steel SLS**.T

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

A good connection. International approvals.

INSTRUCTION MANUAL (ATEX / IECEx)

Compact temperature switch Model TCS

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Hazardous Locations CHAPTER13. Hazardous Location

YFC. Limit switch. Ex d. 24 operating head types

Certificate of Conformity

Section. Cable Glands. sa B-CABLES nv - T 09/ F 09/

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Protection When Safety Matters Most

Clarius EP PLUS LED FLOODLIGHT Installation Guide

CERTIFICATE OF COMPLIANCE

Flameproof Alternator

M-0. M-0... series control, monitoring and signalling devices. Ex e

The Earth-Rite MGV is designed to enable operators establish safe grounding of their vehicle in accordance with these recommended practices.

EX-REPAIR AND MAINTENANCE RECEPTACLES

INSTRUCTION MANUAL (ATEX / IECEx)

Earth-Rite MGV. IECEx SIL 2. Leading the way in hazardous area static control. Mobile Ground Verification System

Flameproof Enclosures

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

VALIADIS S.A. HELLENIC MOTORS

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Compact differential pressure switch Models DC, DCC

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Control Device System NEC Series ConSig 8040

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Terminal Boxes TNCN. Explosion protection Marking

Product Overview. Application

METRIC SELECTION TABLE. Entry Thread A B Catalog #

Thread conversion products, breather drains and accessories

Valve. Monitoring Systems. Limit Switch Box. VMS range For handwheel operated valves

Marine Fire and Gas Dampers

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

SafeSite LED Based Signaling for Hazardous Locations

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Certificate of Compliance

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

COMBUSTION AND ENERGY

Transcription:

IECEx & ATEX 95 CMP PRODUCTS S AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND Triple Certified Single Solution Three Forms of Protection Ex d / Ex e / Ex nr

N O O T H E R M A CONTENTS Leading the Way in Hazardous Areas CMP Products has an international reputation for Quality and Reliability in various sectors of Industry and is highly regarded as the Specialist in the field of Industrial and Hazardous Area Cable Gland and Cable Connector design and manufacture. CMP Products maintains its position as a leader in the business of terminating cables through its commitment to meeting customer needs, providing solutions, whether standard or special, that pay close attention to the heart of application and installer requirements, and in addition by responding to ongoing changes in standards & specification. S TRITON CDS - T3CDS,T3CDSPB, E1FW TRI-STAR, E2FW TRI-STAR, E1FX TRI-STAR, E2FX TRI-STAR S E1FU TRI-STAR, E2FU TRI-STAR PX2K, PX2KPB, PXSS2K, A2FRC TRI-STAR 1 2 CMP Products remains in constant touch with the changes in development of national and international standards, which products and equipment intended for use in flammable atmospheres must meet. Many cable gland products for use in Zones 1, 2, 21 & 22 Hazardous Areas have been available for several years with Dual Certification, referring to both Flameproof Type d (Ex d) and Increased safety Type e (Ex e) forms of protection, according to IEC 60079, parts 1 and 7. Whilst this has suited the requirements for the majority of equipment types installed in hazardous areas, there are other forms of protection, including Zone 2 Ex n apparatus, where Ex d and Ex e cable glands may not be adequate. With special regard to Category II 3 GD Restricted Breathing Type Ex nr equipment, it is particular important to consider the suitability of the cable glands to maintain the integrity of the installation, as some Ex d cable glands do not meet the test requirements of IEC 60079-15 for Ex nr equipment. CMP Products has therefore taken the principle of dual certification one step further and for the first time introduces Triple Certified Ex d, Ex e, & Ex nr approved cable glands that are indeed compatible with more types of equipment than ever before and brings to the market truly universal solutions. No doubt that after careful review this makes the possibility of standardisation on single cable gland solutions for the majority of the Zone 1 & Zone 2, or Zone 21 & Zone 22, hazardous area equipment, worthy of serious consideration. The adoption and integration of IEC standards into a selection of various national standards around the world, including the European Normatives, together with the introduction, and wide spread acceptance, of the IECEx approval scheme (IECEx 02) gives a new impetus to progressive manufacturers like CMP Products. It is now possible to supply cable connecting solutions that are certified under both the CENELEC / ATEX and IECEx approval systems thereby providing the opportunity for dual marking of products that can be installed in global situations. CMP Products - a Global Solutions Provider of Cable Glands, Cable Connectors, and Complementary Cable Related Products & Accessories S A2F TRI-STAR, SS2K TRI-STAR 3 SS2KPB TRI-STAR BREATHER / DRAIN PLUG 781 STOPPER PLUGS 747, 757, 767 ADAPTORS AND REDUCERS 737 S C2K, A2Pe, CWe, CXe S B2KX, C2KX S PX2KX, PXB2KX, PXSS2K, MCA, TMC, TMCX Cable Glands and Cable Connectors are available in a variety of materials including Brass, Nickel, Plated Brass, Aluminium, & Stainless Steel, and with a wide variety of thread forms. A full range of installation accessories is also available on request. 3 3 3 4 4 5

N U F A C T U R E R G I V E S Y O U M O R E TRITON CDS - T3CDS T3CDSPB ARMOURED CABLE TYPES : SINGLE WIRE ARMOUR, S.W.A., WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, S.T.A. SEALING AREA(S) : CABLE INNER BEDDING & OUTER SHEATH ATEX APPROVAL : SIRA 06ATEX1283X IECEx APPROVAL : IECEx SIR 07.0005X, IP67 & IP68 (10M DEPTH) CSA, UL, ARMOURED CABLE TYPES : LEAD COVERED & SINGLE WIRE ARMOUR, WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, e.g. L.C./S.W.A., L.S./S.W.A., OR L.C./S.T.A. ATEX APPROVAL : SIRA 06ATEX1283X IECEx APPROVAL : IECEx SIR 07.0005X, IP67 & IP68 (10M DEPTH) CSA, UL, ARMOURED CABLE TYPE : SINGLE WIRE ARMOUR, S.W.A. SEALING AREA(S) : CABLE INNER BEDDING & OUTER SHEATH E1FW TRI-STAR ARMOURED CABLE TYPE : LEAD COVERED SINGLE WIRE ARMOUR, L.C./S.W.A., OR L.S./S.W.A. E2FW TRI-STAR E1FX TRI-STAR E2FX TRI-STAR ARMOURED CABLE TYPE : WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, S.T.A. SEALING AREA(S) : CABLE INNER BEDDING & OUTER SHEATH ARMOURED CABLE TYPE : LEAD COVERED & WIRE BRAID, LEAD COVERED & STRIP ARMOUR OR LEAD COVERED & STEEL TAPE ARMOUR, e.g. L.C./S.T.A., L.S./S.T.A. OR L.C./G.S.W.B. GOST 1

T E R M I N A T I N G C A B L E S I S O U R B U S I N E S S E1FU TRI-STAR E2FU TRI-STAR ARMOURED CABLE TYPES : SINGLE WIRE ARMOUR, S.W.A., WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, S.T.A. SEALING AREA(S) : CABLE INNER BEDDING & OUTER SHEATH ARMOURED CABLE TYPES : LEAD COVERED & SINGLE WIRE ARMOUR, WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, e.g. L.C./S.W.A., L.S./S.W.A., OR L.C./S.T.A. TEMPERATURE RATING : -60 C TO +100 C ARMOURED CABLE TYPES : SINGLE WIRE ARMOUR, S.W.A., WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, S.T.A. SEALING AREA(S) : INNER CABLE CONDUCTORS (COMPOUND BARRIER) & OUTER SHEATH IECEx APPROVAL : IECEx SIR 06.0044X, IP67 & IP68 (10M DEPTH) CSA, UL, PX2K ARMOURED CABLE TYPES : LEAD COVERED & SINGLE WIRE ARMOUR, WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, e.g. L.C./S.W.A., L.S./S.W.A., OR L.C./S.T.A. BARRIER) & OUTER SHEATH, WITH EARTH BOND TO LEAD SHEATH. IECEx APPROVAL : IECEx SIR 06.0044X, IP67 & IP68 (10M DEPTH) CSA, UL, PX2KPB PXSS2K A2FRC TRI-STAR 2 TEMPERATURE RATING : -60 C TO +100 C CABLE TYPE : UNARMOURED BARRIER) & OUTER SHEATH IECEx APPROVAL : IECEx SIR 06.0044X, IP67 & IP68 (10M DEPTH) CSA, UL, CABLE TYPE : UNARMOURED HOUSED IN CONDUIT IECEx APPROVAL : IECEx SIR 06.0040X

T E R M I N A T I N G C A B L E S I S O U R B U S I N E S S A2F TRI-STAR SS2K TRI-STAR CABLE TYPES : UNARMOURED (OR BRAIDED CABLES ENTERING Ex e TERMINAL ENCLOSURES). IECEx APPROVAL : IECEx SIR 06.0039X, IP67 & IP68 (10M DEPTH) CSA, CABLE TYPES : UNARMOURED (OR BRAIDED CABLES ENTERING Ex e TERMINAL ENCLOSURES)., DOUBLE SEAL IECEx APPROVAL : IEC Ex SIR 06.0041X, IP67 & IP68 (10M DEPTH) CABLE TYPES : UNARMOURED, LEAD SHEATHED (OR LEAD COVERED) * IECEx APPROVAL : IECEx SIR 06.0041X, IP67 & IP68 (10M DEPTH) (Note * : An alternative Ex e only version is also available suitable for terminating Steel Tape Armour, S.T.A. cables.) SS2KPB TRI-STAR COMPONENT APPROVED BREATHER DRAIN PLUG FOR USE WITH INCREASED SAFETY Ex e APPARATUS THAT IS SUSCEPTIBLE TO CONDENSATION OR PRONE TO MOISTURE COLLECTION OR INGRESS DURING NORMAL OPERATION. VERSIONS AVAILABLE IN BRASS, ALUMINIUM, STAINLESS STEEL, OR NON-METALLIC. ATEX APPROVAL : SIRA 01ATEX1284U II 2 GD Ex e II, COMPONENT ZONE 1, ZONE 2, ZONE 21, & ZONE 22 - GAS GROUPS IIA, IIB, IIC CSA, 781 BREATHER / DRAIN PLUG 747, 757 & 767 737 STOPPER PLUGS ADAPTORS AND REDUCERS COMPONENT APPROVED STOPPER PLUGS DESIGNED TO CLOSE UNUSED CABLE ENTRY HOLES IN EXPLOSION PROTECTED EQUIPMENT. VERSIONS AVAILABLE WITH & WITHOUT INTEGRAL O RING SEAL, & IN VARIOUS MATERIALS. ALSO FOR INDUSTRIAL AND SAFE AREA USE. ATEX APPROVAL : SIRA 01ATEX1284U COMPLIANCE : EN / IEC 60079-0, EN / IEC 60079-1, EN / IEC 60079-7, EN 50281 / IEC 61241-0 & IEC 61241-1 II 2 GD Ex d IIC / Ex e II COMPONENT ZONE 1, ZONE 2, CSA, UL, COMPONENT APPROVED ADAPTORS & REDUCERS DESIGNED TO CONVERT THREAD FORMS AND SIZES BETWEEN EXPLOSION PROTECTED EQUIPMENT AND CABLE ENTRY DEVICES. VERSIONS AVAILABLE WITH & WITHOUT INTEGRAL O RING SEAL, AND ALSO FOR INDUSTRIAL AND SAFE AREA USE. ATEX APPROVAL : SIRA 01ATEX1284U COMPLIANCE : EN / IEC 60079-0, EN / IEC 60079-1, EN / IEC 60079-7, EN 50281 / IEC 61241-0 & IEC 61241-1 II 2 GD Ex d IIC / Ex e II COMPONENT ZONE 1, ZONE 2, CSA, UL, 3

S E A L I N G C A B L E S I N H A Z A R D O U S A R E A S C2K A2Pe ARMOURED CABLE TYPES : SINGLE WIRE ARMOUR, S.W.A., WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR, S.T.A. IECEx APPROVAL : IECEx SIR 06.0042X COMPLIANCE : EN / IEC 60079-0, EN / IEC 60079-7, EN 50281 / IEC 61241-0 & IEC 61241-1 II 2 GD Ex e II EQUIPMENT ZONE 1, ZONE 2, ZONE 21, & ZONE 22 - GAS GROUPS IIA, IIB, IIC, Ex td, IP67, IP68 (10M DEPTH) CSA, TEMPERATURE RATING : -20 C TO +70 C CABLE TYPE : UNARMOURED ATEX APPROVAL : PTB 99ATEX3112X, PTB 99ATEX3113X COMPLIANCE : EN / IEC 60079-0, EN / IEC 60079-7 II 2 G Ex d IIC / Ex e II COMPONENT ZONE 1, ZONE 2, ZONE 21, & ZONE 22 - GAS GROUPS IIA, IIB, IIC CABLE TYPES : SINGLE WIRE ARMOUR, S.W.A. IECEx APPROVAL : IECEx SIR 06.0042X COMPLIANCE : EN / IEC 60079-0, EN / IEC 60079-7, EN 50281 / IEC 61241-0 & IEC 61241-1 II 2 GD Ex e II EQUIPMENT ZONE 1, ZONE 2, ZONE 21, & ZONE 22 - GAS GROUPS IIA, IIB, IIC, Ex td CWe CABLE TYPES : WIRE BRAID, STRIP ARMOUR & STEEL TAPE ARMOUR IECEx APPROVAL : IECEx SIR 06.0042X COMPLIANCE : EN / IEC 60079-0, EN / IEC 60079-7, EN 50281 / IEC 61241-0 & IEC 61241-1 II 2 GD Ex e II EQUIPMENT ZONE 1, ZONE 2, ZONE 21, & ZONE 22 - GAS GROUPS IIA, IIB, IIC, Ex td CXe B2KX C2KX ARMORED CABLE TYPE : BRONZE WIRE ARMOR, ARMORED & JACKETED SEALING AREA(S) : NONE ORDINARY LOCATIONS CONNECTOR, FOR NON CLASSIFIED AREAS IN THE MARINE & OFFSHORE INDUSTRIES, INCLUDING MOBILE OFFSHORE DRILLING UNITS. : UL LISTING FILE : E200163 COMPLIANCE : UL514B ABS, & LLOYDS ARMORED CABLE TYPE : ARMORED & JACKETED OR WIRE BRAID ARMOUR, INCLUDING IEEE45 TYPE P COMPLIANT CABLES, e.g. GEXOL, EXANE & BOSTRIG / JACKET WET LOCATIONS CONNECTOR, WITH CLASS I, ZONE 1, AEx e APPROVAL. ALSO SUITABLE FOR DIVISION 2 AREAS WHEN INSTALLED IN ENCLOSURES NOT HAVING INTERNAL IGNITION SOURCE, & NON- CLASSIFIED AREAS. ALSO OFFERS DELUGE PROTECTION TO DTS01:91, FOR USE IN THE MARINE & OFFSHORE INDUSTRIES, INCLUDING MOBILE OFFSHORE DRILLING UNITS : UL LISTING FILE : E200163, E256366 COMPLIANCE : UL514B, ANSI/UL 60079-7, NEMA 4, OIL RESISTANT II ATEX, ABS, DNV & LLOYDS 4

S E A L I N G C A B L E S I N H A Z A R D O U S A R E A S PX2KX PXB2KX ARMORED CABLE TYPE : ARMORED & JACKETED OR WIRE BRAID ARMOUR, INCLUDING IEEE45 TYPE P COMPLIANT CABLES, e.g. GEXOL, EXANE & BOSTRIG BARRIER) & OUTER SHEATH / JACKET HAZARDOUS LOCATIONS CONNECTOR, CLASS I, DIVISION 1, ABCD CLASS II, DIVISION 1, EFG, CLASS III, DIVISION 1 & 2. WITH CLASS I, ZONE 1, AEx d IIC APPROVAL. ALSO OFFERS DELUGE PROTECTION TO DTS01:91, FOR USE IN THE MARINE & OFFSHORE INDUSTRIES, INCLUDING MOBILE OFFSHORE DRILLING UNITS : UL LISTING FILE : E201187, E256367 COMPLIANCE : UL2225, UL886, UL514B, ANSI/UL 60079-0, ANSI/UL 60079-1, NEMA 4X, OIL RESISTANT II CUL, ATEX, ABS, DNV & LLOYDS ARMORED CABLE TYPE : BRONZE WIRE ARMOR, ARMORED & JACKETED OR WIRE BRAID ARMOUR, INCLUDING IEEE45 TYPE P COMPLIANT CABLES, e.g. GEXOL, EXANE & BOSTRIG BARRIER) HAZARDOUS LOCATIONS CONNECTOR, CLASS I, DIVISION 2, ABCD CLASS II, DIVISION 1, FG, CLASS III, DIVISION 1 & 2, WITH CLASS I, ZONE 1, AEx d IIC APPROVAL. FOR USE IN THE MARINE & OFFSHORE INDUSTRIES, INCLUDING MOBILE OFFSHORE DRILLING UNITS : UL LISTING FILE : E201187, E256367 COMPLIANCE : UL2225, UL886, UL514B, ANSI/UL 60079-0, ANSI/UL 60079-1, NEMA 4X, OIL RESISTANT II CUL, ATEX, ABS, DNV & LLOYDS CABLE TYPE : NON-ARMORED MARINE & TRAY CABLES, INCLUDING IEEE45 TYPE P COMPLIANT CABLES, e.g. GEXOL, EXANE & BOSTRIG BARRIER) & OUTER SHEATH / JACKET HAZARDOUS LOCATIONS CONNECTOR, CLASS I, DIVISION 2, ABCD CLASS II, DIVISION 1, FG, CLASS III, DIVISION 1 & 2, WITH CLASS I, ZONE 2, AEx d IIC APPROVAL. FOR USE IN THE MARINE & OFFSHORE INDUSTRIES, INCLUDING MOBILE OFFSHORE DRILLING UNITS : UL LISTING FILE : E161256, E201187, E256367 COMPLIANCE : UL2225, UL886, UL514B, ANSI/UL 60079-0, ANSI/UL 60079-1, NEMA 4X, OIL RESISTANT II CUL, ATEX, PXSS2K ARMORED CABLE TYPE : CORRUGATED / INTERLOCKED STEEL / ALUMINIUM ARMOR & CONTNINUOUSLY WELDED ARMOR CABLES, UL TYPE MC/MCHL, INCLUDING TECK & CLX BRANDS. / JACKET HAZARDOUS LOCATIONS CONNECTOR, CLASS I, II, III, ENCLOSURE TYPE 3, 4 & 4X, CLASS II DIV 1 EFG, CLASS III DIV 1 & 2, CLASS I ZONE 1 Ex e II. : CSA LISTING FILE : 1129334 COMPLIANCE : CSA C22.2 No. 174-M1984, CAN/CSA-C22.2 No. 18-92, CSA C22.2 No. 25-1966, CAN/CSA-C22.2 No. 94-M91, CAN/CSA-E60079-0-2001, IEC 60079-0 1998 MCA TMC TMCX ARMORED CABLE TYPE : CORRUGATED / INTERLOCKED STEEL / ALUMINIUM ARMOR & CONTINUOUSLY WELDED ARMOR CABLES, UL TYPE MC / MCHL, INCLUDING TECK & CLX BRANDS / JACKET HAZARDOUS LOCATIONS CONNECTOR, CLASS I ZONE 1 Ex e II / AEx e II, CLASS II DIV 1 EFG, CLASS II DIV 2, EFG, CLASS III DIV 1 & 2, ENCLOSURE TYPES 3, 4 & 4X : UL LISTING FILE : E163112, CSA 1129339 COMPLIANCE : UL514B, UL886, CAN/CSA-22.2 No. 18-92, CSA C22.2 No. 25-1966, CAN/CSA-C22.2 No. 94-M91, CSA C22.2 No. 174-M1984, CAN/CSA E60079-0-2001, CAN/CSA-E79-7-95, IEC 60079-0:1998 ARMORED CABLE TYPE : CORRUGATED / INTERLOCKED STEEL / ALUMINIUM ARMOR & CONTINUOUSLY WELDED ARMOR CABLES, UL TYPE MC / MCHL, INCLUDING TECK & CLX BRANDS BARRIER) & OUTER SHEATH / JACKET HAZARDOUS LOCATIONS CONNECTOR, CLASS I DIV 1 & DIV 2 ABCD, CLASS II DIV 1 & 2 EFG, CLASS III DIV 1 & 2, CLASS I ZONE 1 Ex d IIC / Ex e II / AEx d IIC, ENCLOSURE TYPES 3, 4, 4X : UL LISTING FILE : E163112, CSA 1129339 COMPLIANCE : UL 2225, UL 2227, UL514B, UL886, CAN/CSA-22.2 No. 18-92, CSA C22.2 No. 25-1966, CAN/CSA-C22.2 No. 94-M91, CSA C22.2 No. 174-M1984, CAN/CSA E60079-0-2001, CAN/CSA-E79-7-95, IEC 60079-0:1998, IEC 60079-1:2004 5

.cn www.cmp-products.ru NEWCASTLE (Headquarters) DUBAI (British Engines (Middle East) FZE) HOUSTON (British Engines Texas Inc) PUSAN CMP Products Glasshouse Street, St Peters Newcastle Upon Tyne NE6 1BS, England Tel: +44 191 265 7411 Fax: +44 191 265 0581 E-Mail: cmp@cmp-products.com CMP Products Middle East Office P.O. Box 61363, Jebel Ali Free Zone Jebel Ali, Dubai, United Arab Emirates Tel: +971 4 887 1012 Fax: +971 4 887 1015 E-Mail: meoffice@cmp-products.com CMP Products 5829W Sam Houston Parkway N#205 Houston, Texas 77041, USA Tel: +1 713 462 2073 Fax: +1 713 462 2076 E-Mail: cmp@cmp-america.com CMP Products (Korea) Ltd Room 8-810, Digital Valley, 132-7, Gamjeon-dong, Sasang-gu Pusan, South Korea E-Mail: pusanoffice@cmp-products.com SINGAPORE SHANGHAI CMP Products (S.E.A) Pte Ltd. 21 Toh Guan Road East, #09-03, Toh Guan Centre Singapore 608609 Tel: +65 6466 6180 Fax: +65 6466 9891 E-Mail: seaoffice@cmp-products.com CMP Products (Representative Office) Room 2407, Building C, Thompson Centre No 188 Zhangyang Road, Pudong District Shanghai, 200120 P.R. China Tel: +86 21 5054 0096 Fax: +86 21 5054 0676 E-Mail: shanghaioffice@cmp-products.com Cable Glands approved for Group I mining applications are also available from CMP Products for a wide variety of cable types. Distributor : 2/F Le Mar Ben II Bldg., 747 San Bernardo St., Sta. Cruz, Manila T: +(632) 734-5344 / 734-5346 / 734-5348 / 736-1654 F: +(632) 733-6454 Email: mail@zenithwire.com www.zenithwire.com