INDEPENDENT TEST LABORATORY REPORT No A

Similar documents
INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

Lighting Sciences

Photometric Indoor Test Report

Integrating Sphere Test Report

Integrating Sphere Test Report

Integrating Sphere Test Report

NVLAP LAB CODE:

T8 4ft 5000K EazyLux EZ8450D7R07

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

NVLAP LAB CODE:

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Test Sample Description Catalog Number: Description:

Calibration Due Date Chroma Programmable AC Source 61604

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Test Sample Description Catalog Number: Description:

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

Report of Test LLIA A-R02*

Report of Test LLIA A

Report of Test LLIA A-R01*

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

Report of Test LLIA A

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Calibration Due Date Chroma Programmable AC Source 61604

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79-08

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

Test Sample Description Catalog Number: Description:

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LLIA A-R02*

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ, 07006

Report of Test LLIA A

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report of Test LLIA A

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Report of Test LLIA A

IESNA LM79: 2008 Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

LIGHT EFFICIENT DESIGN

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO81227W/V2

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LIGHT EFFICIENT DESIGN, LLC

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Test Sample Description Catalog Number: Description:

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Report of Test LLIA A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

Report of Test LLIA

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

Report of Test LLIA

Report of Test LLIA

Photometric Outdoor Test Report

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Transcription:

Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were) tested in accordance with the following applied standards/regulations: IES LM-41-98: Approved Method for Photometric Testing of Indoor Fluorescent Luminaire (withdrawn) IES LM-79-08: Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Prepared for: MAXLITE Approved by: JIM DOMIGAN WEST CALDWELL, NJ LABORATORY TEAM LEADER REVISED NOV 20, 2013 This report shall not be reproduced except in full without the written approval of the laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. Page 1 of 8

INTENSITY(CANDLEPOWER) SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1200 1200 1200 1200 1200 5 1184 1183 1199 1203 1201 115 10 1165 1164 1181 1187 1186 15 1133 1133 1151 1160 1160 323 20 1090 1092 1111 1121 1123 25 1038 1040 1061 1073 1075 486 30 975 979 1000 1014 1017 35 904 908 928 946 950 579 40 828 831 852 869 874 45 747 751 771 787 792 592 50 662 665 683 698 702 55 573 575 590 603 605 526 60 481 481 494 505 507 65 387 387 396 404 406 391 70 292 290 297 303 303 75 198 196 199 203 203 211 80 108 107 108 110 109 85 35 35 35 37 36 47 90 0 0 0 0 0 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LUMINAIRE 0-30 925 28.27 0-40 1503 45.98 0-60 2621 80.16 0-90 3270 100.00 40-90 1767 54.02 60-90 649 19.84 90-180 0 0.00 0-180 3270 100.00 EFFICACY (LUMENS PER WATT): 94.2 *** THIS IS AN ABSOLUTE TEST *** 8 7 8 " LUMINOUS LENGTH: 44.750 INS WIDTH: 8.880 INS LUMINANCE SUMMARY CD./SQ.M. S/MH: 1.3 SC(ALONG): 1.2, SC(ACROSS): 1.3 ANGLE ALONG 45 ACROSS 45 4122 4267 4386 55 3896 4025 4132 65 3574 3667 3760 75 2983 3009 3074 85 1546 1590 1610 TESTED IN ACCORDANCE WITH IES PROCEDURES. Page 2 of 8

INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE PLANE OUTPUT ALONG 22.5 45 67.5 ACROSS AVERAGE LUMENS 0.0 1200 1200 1200 1200 1200 1200 2.5 1189 1188 1203 1208 1206 1199 5.0 1184 1183 1199 1203 1201 1194 115 7.5 1176 1175 1191 1196 1195 1187 10.0 1165 1164 1181 1187 1186 1177 12.5 1151 1150 1168 1174 1174 1164 15.0 1133 1133 1151 1160 1160 1148 323 17.5 1113 1114 1132 1142 1143 1129 20.0 1090 1092 1111 1121 1123 1108 22.5 1065 1067 1087 1099 1100 1084 25.0 1038 1040 1061 1073 1075 1058 486 27.5 1008 1011 1032 1045 1048 1029 30.0 975 979 1000 1014 1017 997 32.5 941 944 965 981 985 963 35.0 904 908 928 946 950 927 579 37.5 867 870 890 908 913 890 40.0 828 831 852 869 874 851 42.5 788 792 812 829 834 811 45.0 747 751 771 787 792 770 592 47.5 706 709 728 743 748 727 50.0 662 665 683 698 702 682 52.5 618 620 637 651 654 636 55.0 573 575 590 603 605 589 526 57.5 528 528 542 554 557 542 60.0 481 481 494 505 507 494 62.5 435 434 446 455 457 445 65.0 387 387 396 404 406 396 391 67.5 339 339 346 353 354 346 70.0 292 290 297 303 303 297 72.5 245 243 248 253 253 248 75.0 198 196 199 203 203 200 211 77.5 152 150 153 155 155 153 80.0 108 107 108 110 109 108 82.5 68 68 68 70 69 68 85.0 35 35 35 37 36 36 47 87.5 12 13 14 14 14 13 90.0 0 0 0 0 0 0 Page 3 of 8

AVERAGE LUMINANCE DATA CD./SQ.M (FOOTLAMBERTS) ANGLE ALONG 22.5 45 67.5 ACROSS 0 4681( 1366) 4681( 1366) 4681( 1366) 4681( 1366) 4681( 1366) 30 4392( 1282) 4421( 1290) 4513( 1317) 4578( 1336) 4582( 1337) 40 4216( 1230) 4243( 1238) 4340( 1266) 4438( 1295) 4448( 1298) 45 4122( 1203) 4149( 1211) 4267( 1245) 4356( 1271) 4386( 1280) 50 4019( 1173) 4051( 1182) 4144( 1209) 4246( 1239) 4257( 1242) 55 3896( 1137) 3914( 1142) 4025( 1174) 4113( 1200) 4132( 1206) 60 3753( 1095) 3768( 1099) 3860( 1126) 3948( 1152) 3957( 1155) 65 3574( 1043) 3575( 1043) 3667( 1070) 3740( 1091) 3760( 1097) 70 3328( 971) 3322( 969) 3391( 989) 3462( 1010) 3456( 1008) 75 2983( 870) 2960( 864) 3009( 878) 3068( 895) 3074( 897) 80 2422( 707) 2417( 705) 2433( 710) 2467( 720) 2452( 715) 85 1546( 451) 1583( 462) 1590( 464) 1646( 480) 1610( 470) Page 4 of 8

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE =.20 CC 90 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00 1 1.121.071.031.00 1.101.051.020.98 1.071.031.000.96 0.990.960.93 0.950.930.91 0.920.900.88 0.86 2 1.030.950.890.83 1.010.930.870.82 0.990.920.860.81 0.880.830.79 0.850.810.77 0.820.790.76 0.74 3 0.950.840.760.70 0.920.830.750.69 0.900.810.740.69 0.780.720.67 0.760.710.66 0.730.690.65 0.63 4 0.870.750.670.60 0.850.740.660.60 0.830.730.660.59 0.700.640.59 0.680.620.58 0.660.610.57 0.55 5 0.810.680.590.52 0.790.670.580.52 0.760.650.570.51 0.630.560.51 0.610.550.50 0.590.540.50 0.48 6 0.740.610.520.45 0.720.600.510.45 0.700.590.500.45 0.570.500.44 0.550.490.44 0.540.480.43 0.42 7 0.680.540.450.40 0.660.530.450.39 0.650.530.450.39 0.510.440.39 0.500.430.38 0.480.420.38 0.36 8 0.630.490.410.35 0.620.480.400.35 0.600.480.400.34 0.460.390.34 0.450.390.34 0.440.380.34 0.32 9 0.590.450.360.30 0.570.440.360.30 0.560.430.360.30 0.420.350.30 0.410.350.30 0.400.340.30 0.28 10 0.540.410.320.27 0.530.400.320.27 0.520.400.320.27 0.390.320.27 0.380.310.27 0.370.310.26 0.25 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LUMINAIRE INPUT WATTS 34.7 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE. Page 5 of 8

ELECTRICAL MEASUREMENTS INPUT VOLTAGE: 120.0 VOLTS AC INPUT CURRENT: 0.291 AMPS INPUT POWER: 34.7 WATTS POWER FACTOR: 99.4 PERCENT TOTAL HARMONIC DISTORTION: 5.99 PERCENT OFF STATE POWER: 0.00 WATTS INPUT VOLTAGE: 277.0 VOLTS AC INPUT CURRENT: 0.138 AMPS INPUT POWER: 34.9 WATTS POWER FACTOR: 91.5 PERCENT TOTAL HARMONIC DISTORTION: 21.33 PERCENT LIGHT OUTPUT LUMENS: 3270 lm EFFICACY: 94.2 lm/w SPECTRAL MEASUREMENTS X: 0.3728 y: 0.3794 u/u': 0.2191 v: 0.3344 v': 0.5016 Duv: 0.0033 CRI(R a ): 84.5 CRI(R 9 ): 24.8 CCT: 4228 K RADIANT FLUX: 10296 mw Page 6 of 8

Tabulated Spectral Power Distribution Wavelength [nm] Wavelength [nm] [mw/nm] [mw/nm] 380 0.18263 590 51.80890 390 0.38033 600 51.15882 400 0.38183 610 49.46888 410 0.65885 620 46.37567 420 2.87896 630 42.58962 430 10.36111 640 38.14492 440 28.11838 650 33.00048 450 61.64113 660 27.52100 460 36.14543 670 22.32810 470 24.32003 680 17.79060 480 19.33973 690 13.89328 490 22.78406 700 10.57650 500 29.13581 710 7.88381 510 34.57099 720 5.72718 520 38.48591 730 4.05518 530 41.88258 740 3.05666 540 45.36787 750 2.40906 550 48.17113 760 1.87204 560 50.21185 770 1.40798 570 51.35628 780 0.52161 580 51.77394 Page 7 of 8

LUMINOUS OPENING SIDE VIEW All testing was conducted in accordance with LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published by the Illuminating Engineering Society of North America (IESNA). The condition of the item tested was new. Stabilization time before testing meets the stabilization requirements of LM-79-08. The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series 6000 Type C Moving Mirror Goniophotometer The photometric reference standard used is a set of three incandescent luminous intensity standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The test results (colorimetric and luminous flux) were obtained by using a Labsphere Model LMS-760 Integrating Sphere. 4 geometry was used. Correction factors were applied for self-absorption. The colorimetric & photometric reference standard used is an incandescent spectral flux standard lamp calibrated and traceable to the U.S. National Institute of Standards and Technology. Power measurements were obtained with a Yokogawa WT210 power analyzer. Ambient temperature during testing was 25 C 1 C, measured using an Omega model DP460. Calibration certificates are on file at the laboratories of Lighting Sciences Inc. The results in this report apply to the test sample(s) mentioned in this report at the time of the testing period only and are not to be used to indicate applicability to other similar products. Page 8 of 8