DX ISOMAX Series Directional Control Valves &

Similar documents
ISOM Features Features eramic Technology ll ISOM products use high-tech ceramic switching technology providing: xcellent Reliability Long life in exce

503 Series Solenoid Pilot Actuated Valves

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic

Isys Micro Series. Valve Products. Operating information. Material specifications. Pilot configuration

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

PVL Series. Solenoid & Remote Pilot Operated 1/8" & 1/4" Valves. Section C. C59

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

ADEX Series Air Control Valves A00.01 Cv M3 Port A05.18 Cv M5 Port A12.47 Cv 1/8" Port zpv02 A B C D E F G H. Section H

Isys Micro Series. Air Control Valves. Section E

N Series. High Speed Inline Poppet Valves 2 & 3-Way. Section D

ADEX Series. Air Control Valves. Section D

Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products.

Single Solenoid External Pilot Normally Closed

Pneumatic Division North America Richland, MI 49083

Solenoid Pilot Actuated Valves

Viking Lite Series Valves Air Control Valves

Valve Products. B Series Valve

Valve Products. Viking Lite Series Valves. Operating information. Minimum operating pressure, PSIG (bar) Materials. Recommended air quality for valves

PVL Series Solenoid & Remote Pilot Operated 1/8" & 1/4" Valves zpv06

3/2 ^ % Features. Construction. Electrical

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

Valve Products Viking Lite Valves

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio

Pneumatic. Prep-Air II 05 Series Air Preparation Units Filter, Regulator, Lubricator, and Modular Accessories Catalog 0708/USA

Installation & Service Instructions

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Assembly kits (501 Series/502 Series/503 Series) 25 Pin Sub-D Connector Kit

Fittings and Tubing. Low Pressure. Fittings and Tubing - Low Pressure. Low Pressure Fittings and Tubing Features: Pressures to 15,000 psi (1034 bar)

F20 & F21 QIX Particulate & Coalescing Filters

Models P, P, P, , DANGER

Mechanical Style Pressure Switch. Specifications

^ % 3/2 5/2 SERIES 362/562. Features. Construction. Nominal Ambient Temp. Ranges. Electrical

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

Couplings - Quick Disconnect

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

Needle Valves. Needle Valves - High Pressure. 30SC, 43SC, 30VM, 40VM, 60VM, 100VM & 150V Series. High Pressure. Pressures to 150,000 psi (10342 bar)

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in.

Valve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

LIGHTWEIGHT + COMPACT. Rotary Union Solutions SPS. Series NPT CONNECTION SIZE OPTIONS

B Series Air Control Valves B3.75 Cv 1/8", 1/4" Port B Cv 1/4", 3/8" Port B Cv 3/8" Port B Cv 1/2" Port B8 7.

Your Global Source for Today s Most Popular Solenoid Valves

Pneumatics Pneumatic Quick ouplings Single Shut-Off ouplings Single Shut-Off couplings are primarily used for pneumatic applications, connecting air t

Catalog. Product Catalog. Setting a new standard for: Quality Reliability Value Global Compatibility

Needle Valves. SM Series. Needle Valves - SM Series. Medium Pressure Valve Features: Medium Pressure. Pressures to 20,000 psi (1379 bar)

Model Model 815

Flow Controls & Accessories

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2

Sliding Seal & Brass Poppet Valves

FRL/AirCare Air Controls & Accessories

Piston Accumulators Series Catalog HY /US Page

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, NAMUR style, 1/4 to 1/2

Valvair II. Solenoid Operated Directional Spool Valves. Section E.

Series VC Direct Operated 2 Port Solenoid Valve for Oil. Series VCL VX VN VQ VDW VC LV PA

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494

Watertight Wiring Devices

Quick Coupling Products

Quick Couplings. Section F

VALVES. V44/V45 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 26 mm

PS1 Modular Interface Valve

atalog /US Index Vacuum ups Product Selection Technical Lifting orces, up iameters, Material Specifications 6-9 P lat Precision molded single li

Application Focused Products. Truck Hydraulics Center Section F. Application Focused Products. Catalog 0650-E

4 Port Solenoid Valve

XM Valve. Air Control Valves Direct Acting, 1/8" Port 3-Way & 4-Way:.15 Cv. Catalog 0661/USA

Catalog 080-/USA Notes Vacuum Control Valves

Pneumatic Valves Viking Lite Series. G1/8 - G3/8 body ported

Piston Accumulators Series Catalog /USA Page

3/2 SRIS Important These solenoid valves are intended for use on clean dry air, inert gas, or sweet dry natural gas filtered to 40 micron or bet

Product Information. W66 Series ROSS CONTROLS

Air Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description

4 Port Solenoid Valve

Husky 1050e Pumps Electric Double Diaphragm

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

Selection Information Molded Case Circuit Breakers

atalog /US asic eatures llen ey Sensor Locking lip ircuit ressure /12 5/32" Tube Instant onnections Driving ressure U xhaust ack ressure Thresho

Gas Springs AGS 15 - AGS 28

Air-Oil Systems, Inc. Gas Springs AGS 15 - AGS 28

High Performance Butterfly Valves 2 Way Way 2-20 Bray MK Series High Performance Butterfly Valves ANSI Class 150 and 300

Vacuum Technology. Catalogue PDE2507TCUK-ab. Convum

ISO & Valves

MK Series High Performance Butterfly Submittal/Technical Data

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

Cable & Wire Management

Heating Cable. Ordering Information SRL-C SRL-CR, CT SRP-C, SRP-CT CWM-C CWM-CT SRL-MC SRL-MCR, MCT SRM/E-C SRM/E-CT SRL-C SRL-CR, CT SRP-C, SRP-CT

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

SUB-BASES and MANIFOLDS for ISO 5599/I VALVES

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe

Table of Contents. Numatics 2009 Rev. 1/09

ROSS CONTROLS. ISO & Valves W66 Series.

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories.

SUPERSPOOL II VALVE PNEUMATIC DIRECTIONAL CONTROL VALVE SERVICE INFORMATION

Transcription:

irectional ontrol Valves 07- & 99-0 0. v. v. v Section www.parker.com/pneu/isomax 0 0.7 v.0 v ISOM 07- eramic, 0 & 0 Valve Range & Features... Features... Specifications... ommon Part Numbers... Model Number Index... 6 dd--fold Ordering Information... 7 Subbases & Manifolds... 8- ccessories... - Selector asket onversion Instructions... -6 0 Manifold ssembly & onversion Instructions...7-0 0 Manifold ssembly... - Subbase ssembly... imensions... -6 ISOM 99- eramic, /", /8", /" Specifications... 7 ommon Part Numbers... 8 Model Number Index... 9 dd--fold ssemblies... 0 ccessories... - lectrical onnectors... 6 Internal / xternal Pilot onversion Instructions... 7 imensions... 8- OL ITMS R MOST POPULR.

atalog 0600P-0/US ISOM Valve Range & Features s 0 to Valve Range 0 /8", ISO 07-, 0 0 /", ISO 07-, 0 /", ISO 99-, /8", ISO 99-, /", ISO 99-, ISO 07- ISO 99- The ISOM range of directional control valves complies with ISO 07- and VM 6 for sizes 0 and 0 and ISO 99- for sizes, and. ISOM provides flows from 0. v to. v. The ISOM range includes valves for pneumatic and electrical actuation with a wide choice of subbases and manifolds to suit different application needs. 99-0 07-0.6 ( mm).0 (6 mm).7 (8 mm) orrosion Free and Modern esign With the valve body in Polyamide reinforced fiberglass and the casing in anodized aluminium, the complete ISOM range presents a coherent modern design to suit most industrial environments. ual Pressure In order to supply different pressures to the same actuator, it is possible to connect main pressure supplies to the exhaust ports and use the pressure port as exhaust port. Vacuum Operation ll ISOM valves may be used for either vacuum or pressure applications.

atalog 0600P-0/US ISOM Features s 0 to Features eramic Technology ll ISOM products use high-tech ceramic switching technology providing: xcellent Reliability Long life in excess of 00 million operations*. Operates with lubricated or non-lubricated air. Low sensitivity to air quality changes. ir Pressure Slider High Performance Slide valve concept allows high flow / size ratio and short response time due to short slide stroke and low friction. Stable Long Lasting Performances Low friction switching: minimum wear of the valve member / seal assembly. Valves Fitted with Switchable Selector to ive Internal or xternal Pilot Supply eramic Plate 0 & 0 Selector askets, & Selector asket Remote Pilot pplicable Markets Industries where ISO standardization is accepted. utomotive Food Processing Medical hemical Tire Manufacturing Steel Processing lass Processing Where OM S xport lobally nd nd * Refer to our warranty conditions. Pressure xhaust

atalog 0600P-0/US Specifications 07- eramic, 0 & 0 ISOM 07- Specifications Standard Subbase: ISO 07- and VM 6 Permissible Fluid ir or Inert as, filtered 0µ (lass per ISO 87-), Lubricated or Non-lubricated Pressure Supply: Possible to supply xhaust s or or ylinder s or, with Internal Pilot Supply. (Not possible with P). Flow: 0 =.7v, 0 =.v Working Temperatures: -0 to 60 ( F to 0 F) Storage Temperatures: -0 to 70 (- F to 8 F) Mechanical Life: > 00 million operations (ry air filtered 0µ, Hz, 6 bar, 0 ) ctuation Type: lectric / Pneumatic with mm Solenoid Valve Interface NOMO 06.60N Flow Rating (v) 0 /8" 0 /" v tested per NSI / (NFP) T.. Solenoid Information ode 60Hz Voltage ata tested with L and Surge Suppression. Mounting Style -Position -Position Manifold 0. 0. Subbase 0. 0.0 Manifold 0.70 0. Subbase 0.7 0.0 0Hz Power (W / V) M.W 0 0.6V Response Time** Single Solenoid -Position - ir Return / Spring ssist Valve 0 u. In. hamber ## u. In. hamber Fill xhaust Fill xhaust 0 /8" 0.0 0.00 0. 0.0 0 /" 0.0 0.00 0. 0.00 ## 0 (), 0 (.) ** With 00 PSI supply, time required to fill from 0 to 90 PSI and xhaust from 00 PSI to 0 PSI measured from the instant of energizing or de-energizing V solenoid. Tested per NSI / (NFP) T..8 Operating Pressure Vacuum to PSI (0 bar) Function Material Specifications M.O.P (PSI) 0,,, -Position, Spring Return 6 0,,, -Position, ir Return 0 0, 0, 06, 08 -Position 09,,, 7 -Position, 6, 8, 9, -Position, P, -Position, P Valve Member...Self Lubricating cetal Seat...eramic ody...polyamide Reinforced Fiberglass asing...nodized luminum nd Plates...Painted Zinc Plated Steel Valve Plate... Zinc Seals...Nitrile Springs... Stainless Steel Screws...Zinc Plated Steel Function Selector...Polyamide Reinforced Fiberglass Top over Seal... Polyester

atalog 0600P-0/US ommon Part Numbers Single Solenoid -Position 07- eramic, 0 & 0 ouble Solenoid -Position Sol. Sol. Sol. 0 0-6-9 0-6-9M 0V V. v 0 0-606-9 0V 0-606-9M V. v 0 0-6-9 0-6-9M 0V V.7 v 0 0-606-9 0-606-9M 0V V.7 v ouble Solenoid -Position P -Position P P # # # # # # P P 0 0 0-66-9 0V 0-6-9 0V 0-6-9 0V.0 v.0 v.0 v 0-66-9M V 0-6-9M V 0-6-9M V 0-66-9 0V 0-6-9 0V 0-6-9 0V.0 v.0 v.0 v 0-66-9M V 0-6-9M V 0-6-9M V Torque Specifications 0: to in-lbs (.69 to.8 Nm) 0: 0 to 0 in-lbs (.6 to.9 Nm) For Subbases and Manifolds, see page 8 thru 0.

atalog 0600P-0/US Model Number Index 07- eramic, 0 & 0 OL OPTIONS R MOST POPULR 0 6 06 9 M asic Series ISO 07- (8mm) 0 ISO 07- (6mm) 0 Pilot ir Operated Remote Pilot Solenoid Operated 6 Function Internal Pilot Supply / aptured xhaust -Position, Spring Return -Position, ir Return -Position 06 -Position, -Position, P 6 -Position, P xternal Pilot Supply / aptured xhaust * -Position, Spring Return -Position, ir Return -Position 0 -Position, 09 -Position, P 9 -Position, P Internal Pilot Supply / Vented xhaust -Position, Spring Return 0 -Position, ir Return 0 -Position 0 -Position, 7 -Position, P xternal Pilot Supply / Vented xhaust* -Position, Spring Return -Position, ir Return -Position 08 -Position, -Position, P 8 * Must be specified when using Sandwich Regulators. Voltage & Frequency 60Hz 0Hz 0 0 M lank Remote Pilot Override lank Remote Pilot Non-Locking, Flush Locking, Flush Operator 60 None, Remote Pilot Valve 9 mm, -Pin, IN 60 Note: 0 8mm Valve Remote Pilot Option only available with PL0 Individual Subbase Kits 6

atalog 0600P-0/US dd--fold Ordering Information # nd 07- eramic, 0 & 0 How To Order dd--fold ssemblies. List dd--fold ssembly call out. This automatically includes the end plate kit assembly.. List complete valve/base model number. List left to right, looking at the cylinder ports on the # end of the manifold. The left most station is station. (If a blank station is needed, list the blanking plate part number and the individual manifold number in the station specified.) # nd Station Station Station Station * * * ach Manifold has two () Stations (ven number of Stations Required) } } Model Number 0 U 0 0 Valve Series Right & Left nd Plate 07-, 0 0 Right & Left nd Plate 07-, 0 0 Right & Left nd Plate 07, 0 & 0 H* * ommonnd Plates for 0 & 0. Must be used with nd Plate Type U. nd Plate Type H Non-ollective Wiring S Number of Stations* 0 Stations 0 Stations Stations Stations * Must be ordered in multiples of. Maximum Number. 0 & 0 Non-ollective Wiring U* * Must be used with Valve Series 0 & 0. Type 0 NPT SPP xample: pplication requires a -Valve manifold. Qty. Part No. 0U00 0-6-9M... Valve Station 0-06-60... Valve Station PLP0-0-80... ase Station & 0LK... Valve Station 0-6-9M... Valve Station PLP0-0-80... ase Station & Note: 0 Manifolds cannot be used for remote pilot. 7

atalog 0600P-0/US 0 ases 07- eramic, 0 Individual Subbase Kit with Side s NPT Kit Number SPP 8mm 0 /8" PL0-0-80 PL0-0-70 # # # Note: an be used for external, single, or double remote pilot. # # # # Two Station Manifold ase with Side s NPT Kit Number SPP # alley 8mm 0 /8" PLP0-0-80 PLP0-0-70 Note: an be used for external pilot, not remote pilot. askets and assembly hardware included. # # alley IN Rail Mount # alley PLP0 H (#) alley # # nd Plate Kit for Side ed Two Station Manifold ase NPT Kit Number SPP 8mm 0 /8" P0-0-80* P0-0-70 Notes: Put a vent or muffler in H port when capturing pilot exhaust pressure with a solenoid valve. (See page 8 for gasket selector details. askets and assembly hardware included. Torque Specifications: to in-lbs (.8 to.9 Nm) # # # IN Rail Mount H (#) # P0 (Type P ) 8

atalog 0600P-0/US 0 ases 07- eramic, 0 Individual Subbase Kit with Side s # # # NPT Kit Number SPP # 6mm 0 /" PL0-0-80 PL0-0-70 Note: an be used for external, single, or double remote pilot. # # # Two Station Manifold ase with Side s NPT Kit Number SPP 6mm 0 /" PLP0-0-80 PLP0-0-70 # alley # # alley # Notes: an be used for single remote pilot using the # and external pilot. askets and assembly hardware included. IN Rail Mount ommon xhaust # alley PLP0 # ommon # NPT Kit Number SPP 6mm 0 /" PL0-0-80 PL0-0-70 # alley # alley Notes: # ports work independently when plunger is not depressedby a plug. When a plug is inserted in # along with the captured pilot exhaust gasket selector option, pilot exhaust is sent to ther ommon xhaust. o Not plug exhaust, insert a vent of muffler. # askets and assembly hardware included. an be used for external, single or double remote pilot. # # IN Rail Mount ommon xhaust # alley # PL0 (See Page 8-0 for details) nd Plate Kit for Side ed Two Station Manifold ase NPT Kit Number SPP 6mm 0 /" P0-0-80* P0-0-70 * Use with PLP0 or PL0 Notes: Put a vent or muffler in H port when capturing pilot exhaust pressure with a solenoid valve. (See page 8 for gasket selector details. askets and assembly hardware included. Torque Specifications: to in-lbs (.8 to.9 Nm) IN Rail Mount H # # # P0 9

atalog 0600P-0/US Ordering Information 07-0 & 0 Manifolds & Subbases 07-, 0 & 0 Manifold / Subbase Kits PS 0 P asic Series ISO 07-0 ISO 07-0 PS6 PS nclosures / Lead Length 0 None, No lectrical - 07- Mounting Style / 0 Manifold with /8 NPT nd s Manifold with /8 SPP nd Manifold with /8 NPT ottom / nd 6 Manifold with /8 SPP ottom / nd 6 0 Subbase with / NPT Side s Subbase with / SPP Side s Subbase with / NPT ottom / Side Subbase with / SPP ottom / Side Manifold with / NPT nd Manifold with / SPP nd Manifold with / NPT ottom / nd 6 Manifold with / SPP ottom / nd 6 Subbase Kits Manifold Kits 0 Series Subbase 0 Series -Station Manifold 0 Series -Station Manifold 0

atalog 0600P-0/US Ordering Information 07-0 & 0 nd Plate Kits 07-, 0 & 0 nd Plate Kits PS6 0 0 P asic Series ISO 07, 0, 0 PS6 Thread Type 0 NPT SPP nd Plate Kit Type nd Plate, Non-ollective Wiring Options 0 Non-ollective Wiring 0-0 Non-ollective Wiring nd Plates

atalog 0600P-0/US ccessories 07- Sandwich Regulators Sandwich Regulators Features Remote ir Pilot Operated for hard-to-reach pressure control. Unregulated Pilot Pressure to valve for consistent valve shifting regardless of pressure adjustment. 0 (Independent ual Regulator Shown) 0 (ommon Regulator Shown) OL OPTIONS R MOST POPULR PS67 6 6 P asic Series 0 07-, 8mm PS67 0 07-, 6mm PS7 Regulator Function ommon Pressure Regulator Independent Pressure Regulator # Regulator / auge* -60 PSI w/o auge - PSI w/o auge -60 PSI w/auge 6 - PSI w/auge * For ommon Pressure Regulator Option, Regulator auge callout must be the same number for both # and #. (xample: 66) # Regulator / auge* -60 PSI w/o auge - PSI w/o auge -60 PSI w/auge 6 - PSI w/auge * For ommon Pressure Regulator Option, Regulator auge callout must be the same number for both # and #. (xample: 66)

atalog 0600P-0/US ccessories 07- eramic, 0 & 0 Intermediate ir Supply ase Kit Number NPT 8mm 0 /8" NPT 0P-0-80 6mm 0 /" NPT 0P-0-80 Notes: asket & Mounting olts included. Torque Specifications 0: to in-lbs (.69 to.8 Nm) 0: 0 to 0 in-lbs (.6 to.9 Nm) Manifold Isolation isc 8mm 0 6mm 0 Note: iscs per Kit. ommon Pressure 00 00 lanking Plate 8mm 0 6mm 0 ommon Pressure 0LK 0LK Notes: asket & Mounting olts included. Torque Specifications 0: to in-lbs (.69 to.8 Nm) 0: 0 to 0 in-lbs (.6 to.9 Nm) Sandwich Flow ontrol Features oth adjustment screws are located on the end of the unit. Sandwich Flow ontrol mounts with its own studs, which means the valve uses standard bolts for mounting. Sandwich Flow ontrol is not to be used as a shut off device and is not bubble tight when needles are fully turned down. 8mm 0 6mm 0 Kit Number PS6P PSP 0 8mm Shown

0 atalog 0600P-0/US ccessories & lectrical onnectors 07- eramic, lectrical ccessories Manifold to Manifold asket Kits 0 * 0 * Standard locked # locked #,, s locked #, s PS6P PS6P PS6P PS6P PS6P PS6P 0 0 0MMSKT (PLP0) 0MMSKT (PLP0) PS6P PS6P * askets used with PS6 & PS Manifolds. 0MMSKT (PLP0) 0MMSKT (PLP0) mm -Pin IN 60 onnectors.mm Top of light onnector onnector with 6' (m) ord escription PS9P PS9P No ircuit oard PS9679P PS9679P* Light W Wire mm mm PS968P PS968P* Light 0/0V * L with surge suppression. Note: Max. ø6.mm cable size required for connector without 6' (m) cord. IP6 rated when properly installed. Molded 6' ord Shown ngineering ata: onductors: Poles Plus round able Range (onnector Only): to 6mm (0.6 to 0. Inch) ontact Spacing: 8mm mm -Pin IN 60 Replacement Solenoid Kits Machine Screw (old olored) Torque:. -. N m (.6 -. In. Lbs.) Voltage Non-Locking Locking V PS989P PS989P 0/0, 0/60 PS98P PS98P 0 Solenoid ssembly (Pins Up Shown) lternate Self Tapping Screw Used With Other Products Torque:.7 -.9 N m (6-8 In. Lbs.) Seal lternate Seal - Used With Other Products Manifold olt Kit Part Number 0MM** Items olt, Washer & Nut* * Includes 0 olts, 0 Washers, 0 Nuts ** Use this number for both sizes, 0 & 0. Torque Specifications: to in-lbs (.8 to.9 Nm) Screws for:... H M x 0... H M6 x 0... H M8 x 60 (Screws also available in stainless steel)

atalog 0600P-0/US Selector asket onversion Instructions 07- hanging Top asket / Pilot Supply hanging from Internal to xternal Pilot Supply Install This over fter Rotating asket Remove over as Shown Remove over as Shown Remove Solenoid ssembly, Spacer and asket Remove Pilot Supply Selector and Rotate to Show "" in Position as Shown and Reinstall asket and overs. ( Side is Now xternal Pilot) Position of Pilot Supply Selector for Internal Pilot when Using with Solenoid Operator Remove Pilot Supply Selector and Rotate to Show "" in Position as Shown and Reinstall asket and overs. ( Side is Now xternal Pilot) Position of Pilot Supply Selector for Internal Pilot when Using with Solenoid Operator View hanging from xternal Pilot Supply, Vented Pilot xhaust to Internal Pilot Supply, aptured Pilot xhaust Flip Pilot xhaust Selector to change functionality; desired Function Indicator should be oriented to top. ( Side is now aptured Pilot xhaust) aptured Pilot xhaust Rotate Pilot Supply Selector to change functionality; desired Function Indicator should be oriented to top. ( Side is now Internal Pilot) Internal Pilot Rotate Pilot Supply Selector to change functionality; desired Function Indicator should be oriented to top. ( Side is now Internal Pilot) Internal Pilot xternal Pilot Flip Pilot xhaust Selector to change functionality; desired Function Indicator should be oriented to top. ( Side is now aptured Pilot xhaust) aptured Pilot xhaust Vented Pilot xhaust xternal Pilot Same Pilot Pressure pplied to and (Option vailable on Side Pilot Supply Selector Only) Pilot Supply Selector Pilot xhaust Selector Vented Pilot xhaust Function Indicators xternal Pilot Internal Pilot Same Pilot Pressure (On Side Only) aptured Pilot xhaust Vented Pilot xhaust

atalog 0600P-0/US Selector asket onversion Instructions 07- eramic, asket Selection hart Internal Pilot Supply; aptured Pilot xhaust through xternal Pilot Supply on ; Internal Pilot Supply on ; Vented Pilot xhaust xternal or Single Remote Pilot Supply on ; Internal Pilot Supply on ; aptured Pilot xhaust through xternal Pilot Supply ommon to ; aptured Pilot xhaust through xternal, ouble Remote Pilot Supply on & ; aptured Pilot xhaust Internal Pilot Supply; Vented Pilot xhaust Internal Pilot Supply on ; xternal Pilot Supply on ; Vented Pilot xhaust ase Pilot Used Pilot ir Supply None and None Internal Pilot Supply xternal Pilot Internal Pilot xternal, ouble Remote Pilot for and Internal Pilot Supply xternal Pilot Internal Pilot One ommon xternal Pilot Pressure for and Internal Pilot xternal Pilot Pilot xhaust aptured aptured aptured Vented Vented aptured Vented / ouble Solenoid 606 06 60 F / Single Solenoid, 6 60 F Spring Return / Single Solenoid, ifferential Return / Pressure enter xhaust / Pressure ll s locked 6 6 66 6 Part Numbers vailable From Factory Insert a muffler or vent in the H of the P0 & P0 Manifold nd Plates or # of PL0 & PL0 Subbases when using solenoids with a aptured xhaust. 6 67 6 F F F F See asket onfigurations bove for These Special daptations plug may be inserted in the H of the P0 & P0 Manifold nd Plates # or # of PL0 & PL0 Subbases when using a Vented xhaust. 6

atalog 0600P-0/US 0 Manifold ssembly 07- eramic, 0 xploded rawing Manifold ssembly s...pressure...# ylinder, to Flow Path...ylinder xhaust, to Flow Path...# ylinder, to Flow Path...ylinder xhaust, to Flow Path...# Pilot... # Pilot Torque Specifications: to in-lbs (.8 to.9 Nm) -Station Manifold ase # # Pilot s # # s # s # Pilot s Pilot xhaust 0 Shown # 7

atalog 0600P-0/US Manifold onversion Instructions 0 Series 07- eramic aptured Pilot xhaust, uilt-in Selector aptured Pilot xhaust PL0, 0 uilt-in -Position Selector converts the xternal Pilot hannel () into a ommon Solenoid Pilot xhaust hannel. Pilot hannel Pilot hannel Pipe Required # # ommon Manifold Pilot xhaust (Muffler in nd Plate) Pilot (asket - asket or - Fitting) Manifold Pilot Pilot xhaust aptured & Physically Relocated (Muffler Required) uilt-in Selector # Pilot xhaust (Muffler Required) nd Plate When using, or aptured Selector asket Positions, the Pilot is plugged. The Pilot has a plug when using asket or a fitting when using asket or. When in place, the in the Pilot depresses the Selector to connect the Valve Solenoid Pilot xhaust to a ommon Manifold xhaust. The must make contact with the Pin of the Internal heck Valve. Insert a Muffler in the H of the nd Plate. OR aptured Selector asket Positions When using, or Selector asket Positions as shown in the schematic at right. 0 Manifold ssembly Schematic for aptured Selector asket Positions, and Internal Pilot Supply; aptured Pilot xhaust xternal or Single Remote Pilot Supply on ; Internal Pilot Supply on ; aptured Pilot xhaust To ctuator 0 Valve xternal Pilot Supply ommon; aptured Pilot xhaust Insert a muffler or vent in the H of the P0 & P0 Manifold nd Plates or # of PL0 & PL0 Subbases when using solenoids with aptured Pilot xhaust. asket - asket & Fitting ir In a H b Valve Manifold nd Plate Muffler / Silencer Muffler / Silencer Muffler / Silencer (Required) 8

atalog 0600P-0/US Manifold onversion Instructions 0 Series 07- eramic Vented Pilot xhaust, uilt-in Selector Vented Pilot xhaust Pilot hannel Pilot hannel (Optional Pipe Shown) # # # Pilot (asket - Fitting asket - ) ommon Manifold Pilot xhaust ( in nd Plate) Pilot (asket F - Fitting asket - ) Pilot xhaust () Manifold uilt-in Selector nd Plate When using or Vented Selector asket Positions, the Pilot may be plugged (Optional). The Pilot has a plug when using asket or a fitting when using asket or F. The valve solenoid pilot exhaust vents out the pilot adapter on the asket Selection. Vented Selector asket Positions When using, F or Selector asket Positions, pilot exhaust air is vented out the valve. 0 Manifold ssembly Schematic for Vented Selector asket Positions or xternal Pilot Supply on ; Internal Pilot Supply on ; Vented Pilot xhaust Internal Pilot Supply on ; xternal Pilot Supply on ; Vented Pilot xhaust To ctuator 0 Valve Internal Pilot Supply; Vented Pilot xhaust F plug may be inserted in the H of the P0 & P0 Manifold nd Plates, # of PL0 & PL0 Subbases. asket - Fitting asket ir In a H b Valve Manifold nd Plate Muffler / Silencer Muffler / Silencer asket F - Fitting 9

atalog 0600P-0/US Manifold onversion Instructions 0 Series 07- eramic xternal ouble Remote Pilot, uilt-in Selector xternal ouble Remote Pilot Pilot hannel Pilot hannel Fitting # # Pilot (asket - Fitting) ommon Manifold Pilot xhaust ( in nd Plate) Pilot (asket - Fitting) # Pilot xhaust () uilt-in Selector When using xternal ouble Remote Pilot Selector asket Position, a fitting is used in Pilot &. Free flow between & and the valve allows Remote Pilot Pressure and an exhaust path for the captured pilot exhaust. xternal ouble Remote Pilot Selector asket Position When using Selector asket Position. xternal, ouble Remote Pilot Supply on & ; aptured Pilot xhaust out valve 0 Manifold ssembly Schematic for xternal ouble Remote Pilot Selector asket Position To ctuator 0 Valve a b Valve Fitting ir In Manifold nd Plate Muffler / Silencer Muffler / Silencer Fitting H 0

atalog 0600P-0/US 0 Manifold ssembly 07- eramic, 0 xploded rawing Manifold ssembly s...pressure...# ylinder, to Flow Path...ylinder xhaust, to Flow Path...# ylinder, to Flow Path...ylinder xhaust, to Flow Path...# Pilot...# Pilot Torque Specifications: to in-lbs (.8 to.9 Nm) -Station Manifold ase # Pilot # s # s # # # # (xh) Pilot 0 Shown

atalog 0600P-0/US Manifold onversion Instructions aptured Pilot xhaust 0 Series 07- eramic aptured, xhaust Unplugged PLP0, 0* s shown in the illustrations below, the H () & Pilot s are exhausted internally in the valve body into a single chamber labeled H on the end plate. When using,, or Selector asket Positions, the H () Pilot is vented with a muffler or micron screen. The Pilot is plugged. Pilot hannel H () Pilot # Pilot () Pilot xhaust aptured & Physically Relocated (Muffler Required) OR H (#) Pilot (Muffler - Required) aptured Selector asket Positions When using,, or, Selector asket Positions, the ports must be either plugged or vented with a muffler or micron screen as shown in the schematic at right. Internal Pilot Supply; aptured Pilot xhaust through xternal or Single Remote Pilot Supply on ; Internal Pilot Supply on ; aptured Pilot xhaust through 0 Manifold ssembly Schematic for aptured Selector asket Positions,, and To ctuator a b 0 Valve xternal Pilot Supply on ; Internal Pilot Supply on ; Vented Pilot xhaust * PLP0 Manifolds can be used for xternal Pilot, NOT Remote Pilot xternal Pilot Supply ommon to ; aptured Pilot xhaust through asket - asket, or - Fitting ir In () H Muffler (Required)

atalog 0600P-0/US Manifold onversion Instructions 0 Series 07- eramic Vented, xhaust ged Vented Pilot xhaust PLP0, 0 When using F or Selector asket Positions, the H () Pilot and the Pilot are plugged and the Pilot xhaust is vented through the Pilot dapter. Pilot hannel H () Pilot # Pilot () H H (#) Pilot () Vented Selector asket Positions When using F or, Selector asket Positions, the ports must be either plugged or vented with a muffler or micron screen as shown in the schematic at right. 0 Manifold ssembly Schematic for Vented Selector asket Positions F and Internal Pilot Supply on ; xternal Pilot Supply on ; Vented Pilot xhaust Internal Pilot Supply; Vented Pilot xhaust To ctuator 0 Valve a b F plug may be inserted in the H of the P0 & P0 Manifold nd Plates or # of PL0 & PL0 Subbases. ir In () H asket F - Fitting asket -

atalog 0600P-0/US 0 & 0 Subbase ssembly 07- eramic, asket Selection harts Subbase ssembly s...pressure...# ylinder. to Flow Path....ylinder xhaust. to Flow Path....# ylinder. to Flow Path....ylinder xhaust. to Flow Path.... # Pilot... # Pilot aptured Selector asket Positions When using,,, or, Selector asket Positions, the ports must be either plugged or vented with a muffler or micron screen as shown in the schematic at right. Internal Pilot Supply; aptured Pilot xhaust through xternal or Single Remote Pilot Supply on ; Internal Pilot Supply on ; aptured Pilot xhaust through 0 & 0 Subbase ssembly Schematic for aptured Selector asket Positions,,, and To ctuator 0-0 Subbase * xternal, ouble Remote Pilot Supply on & ; aptured Pilot xhaust out valve xternal Pilot Supply ommon to ; aptured Pilot xhaust through xternal Pilot Supply on ; Internal Pilot Supply on ; Vented Pilot xhaust ir In a b () H asket - asket,, or - Fitting # (asket - ; # asket,, or - Fitting) # # (Muffler Required) OR Pilot xhaust aptured & Physically Relocated (Muffler Required) Vented Selector asket Positions When using F or, Selector asket Positions, the ports must be either plugged or vented with a muffler or micron screen as shown in the schematic at right. Internal Pilot Supply on ; xternal Pilot Supply on ; Vented Pilot xhaust Internal Pilot Supply; Vented Pilot xhaust 0 & 0 Subbase ssembly Schematic for Vented Selector asket Positions F and To ctuator 0-0 Subbase a b F ir In () H asket F - Fitting asket - () (asket F - Fitting; asket - )

0 0 atalog 0600P-0/US imensions 07- eramic, 0 & 0 Valves F 0 0 F Series F 0 0.06 (0).06 (0).6 ().6 (). (6). (6).06 (7).06 (7). (8). (8).7 (8).0 (6). (80).9 (00) Inches (mm) 0 0 Individual Subbase F H Series Part Number F H 0 0 PL0 PL0. (80).9 (00).87 ().0 (8).06 (7).6 (). (8).9 (0).76 (70). (90).6 ia. (Ø.).6 ia. (Ø.) /8 M / /8 Inches (mm) 0 -Station Manifold ases 0 H H F F H Series 0 0 Part Number PLP0 / P0 PL0 / PLP0 / P0 F H. (8.).7 (). (80).9 (00).7 ().9 ().6 ia. (Ø.).6 ia. (Ø.).0 (8). (). ().67 (7).7 (8).87 ().8 (7). (90) Inches (mm)

atalog 0600P-0/US imensions Subbases, Manifolds, Sandwich Regulators 0 0 07-, PS Subbases /8 Inch s & For xternal Pilot / Inch s &.88 ().8 (.).00 (0.8).9 (7) c of ase L / Inch s, &. (6.) Inches (mm) F.6 (80.).9 (7.9) Side ed Subbase F ottom ed Subbase F () ottom s.8 (7,) Mtg. Holes () 0 0 0 & 0 07-, PS6 & PS Manifolds.98 ().9 (7).6 (0.8). (6.8) L N / / () /8 Inch Pilot s / Inch s & /8 Inch.6 (6) H. (09.8) M. (8.) Inches (mm).0 (7.). () N.8 (6) F. (.) K.68 (.7). (0.6) L.7 (06) M K 8mm ( x n + x n) + F ( x n + x n) + 6mm n = Number of H ases n = Number of H ases = H Series = H Series 0 psi psi 0 Series Part Number 0 0 PS67 PS7 0.8 (6) 0.0 () 6. (6) 6. (6).0 (6). (6). (0).0 (7).60 (66).00 ().8 (0).8 (0) Inches (mm) 6

atalog 0600P-0/US Specifications ISOM 99- eramic Technology / Valve Specifications Subbase Mounted Valves onforming to ISO Standard 99/ High Flow: (. v), (.0 v), (. v) ir or Solenoid Operation Using NOMO Solenoids an e Vacuum Operated ir ondition: Filtered to 0µ ual Pressure Supply from xhaust s: Yes - Without additional pressure at and ust and Water Protection: IP 6 (ccording to N 609) Mechanical Life: > 00 million operations (ry air filtered 0 µ, Hz, 6 bar, 0 ) Media: ir or inert gas, filtered 0 µ (lass according to ISO 87-), lubricated or non-lubricated Operating Temperature Range: -0 to 60 ( F to 0 F) Flow Rating (v) Mounting Style -Position -Position /" s Subbase. 0.7 /" s Manifold 0.80 0.60 /8" s Subbase.0.0 /8" s Manifold.0.9 /" s Subbase..00 /" s Manifold.0.6 v tested per NSI / (NFP) T.. Flow Rating (v) with Sandwich Regulator ommon Pressure ual Pressure - - - - - - - - 0. 0.9.06.0 0. 0. 0. 0.8.06.0..7 0.9 0.66 0.77. Note: ll v s calculated with regulator adjusted full open. 99- eramic,, & Response Time** Single Solenoid -Position - ir Return / Spring ssist Valve /".0.00.60. /8".00.0.70. /".060.06..0 ## (0), (00), (00) ** With 00 PSI supply, time required to fill from 0 to 90 PSI and xhaust from 00 PSI to 0 PSI measured from the instant of energizing or de-energizing V solenoid. Tested per NSI / (NFP) T..8 Solenoid Information ata tested with L and Surge Suppression. 0 u. In. hamber ## u. In. hamber Fill xhaust Fill xhaust Voltage Power ode (W / V) 60Hz 0Hz 9.8W 9.7W 0.7V Operating Pressure Vacuum to PSI (0 bar) Function M.O.P. (PSI) Internal Pilot -Position, Spring Return 6 0 0 -Poswition, ir Return 0 0 0 06 -Position -Position, 6 6 6 -Position, P 6 6 -Position, P 6 6 xternal Pilot -Position, Spring Return 6 0 0 -Position, ir Return 0 0 0 08 -Position -Position, 6 6 8 -Position, P 6 6 -Position, P 6 6 Material Specification ody...polyamide Reinforced Fiberglass asing - nd Plates...nodized luminium Seals...Nitrile Screws...Zinc Plated Steel Valve Member / Seat... Self Lubricating / eramic Valve Plate... Zinc 7

atalog 0600P-0/US ommon Part Numbers Single Solenoid -Position 99- eramic,, & ouble Solenoid -Position Shown Sol. Sol. Sol. -6-L 0V -6-L9 V -6-L 0V -6-L9 V -6-L 0V -6-L9 V. v.0 v. v 0mm -Pin Solenoid, NLMOR, Unlighted, Internal Pilot, Valve Less ase -606-L 0V -606-L9 V -606-L 0V -606-L9 V -606-L 0V -606-L9 V. v.0 v. v 0mm -Pin Solenoid, NLMOR, Unlighted, Internal Pilot, Valve Less ase ouble Solenoid -Position P -Position # P # # # # P # P P -66-L 0V -6-L 0V -6-L 0V.7 v.7 v -66-L9 V -6-L9 V -6-L9 V.7 v -66-L 0V.0 v -6-L 0V.0 v -6-L 0V.0 v -66-L9 V -6-L9 V -6-L9 V -66-L 0V -6-L 0V.00 v -66-L9 V -6-L9 V.00 v 0mm -Pin Solenoid, NLMOR, Unlighted, Internal Pilot, Valve Less ase. Torque Specifications : to in-lbs (.8 to.9 Nm) : to 0 in-lbs (.99 to.69 Nm) : 0 to 0 in-lbs (.6 to.8 Nm) For ompact and VM Subbase and Manifold, see page. For Hi-Flow Subbases and Manifolds, see page. 8

atalog 0600P-0/US Model Number Index 99- eramic,, & OL OPTIONS R MOST POPULR 6 06 L asic Series ISO 99- - ISO 99- - ISO 99- - Pilot ir Operated Remote Pilot Solenoid Operated 6 Function Internal Pilot Supply -Position, Spring Return ** -Position, iff Return -Position 06 -Position, -Position, P 6 -Position, P * xternal Pilot Supply -Position, Spring Return -Position, iff Return -Position 08 -Position, -Position, P 8 -Position, P * * Not offered with Valves. ** Spring Return versions are air assisted. Must be specified when using Sandwich Regulators. 60Hz Voltage & Frequency 0Hz 9* 9 0 0 lank Remote Pilot or Valve Less oil * L & Surge Suppression. Only vailable with nclosure 6. 99- nclosure / Lead Length 0** None, Remote Pilot Valve 6* -Pin, M URO onnector with NOMO Operator L -Pin, 0mm IN 60 with NOMO onnector P -Pin, mm Industrial with NOMO onnector N None, Valve Less oil * Only available with Overrides / Lights Option & H with nclosure / Lead Length Option 6. **Must use Overrides / Lights Option 6 or 7. Must use Overrides / Lights Option or. 99- Overrides / Lights 6 Remote Pilot / Without Solenoid 7* Remote Pilot / Without Solenoid Non-Locking, Flush, Push - w/o Light Locking, Flush, Push / Turn - w/o Light ** Non-Locking, Flush, Push - w/ Light H** Locking, Flush, Push / Turn - w/ Light * irect Manual Override ** pply to Voltage ode 9 & nclosure / Lead Length 6 9

atalog 0600P-0/US dd--fold Ordering Information # nd 99- eramic,, & How To Order dd--fold ssemblies. List dd--fold ssembly call out. This automatically includes the end plate kit assembly.. List complete valve/base model number. List left to right, looking at the cylinder ports on the # end of the manifold. The left most station is station. (If a blank station is needed, list the blanking plate part number and the individual manifold number in the station specified.) # nd Station Station Model Number H S 0 0 Valve Series, ISO H, ISO H, ISO H nd Plate Type Standard Non-ollective Wiring S VM, 99- V Type NPT 0 SPP Transition Plate lank No Transition Plate * to * to ** to * Use Valve Series. ** Use Valve Series. Number of Stations 0 Station Stations xample: pplication requires a -Station manifold. Qty. Part No. HS00-6-L9... Valve Station PS70P...ase Station -606-L9... Valve Station PS70P...ase Station 0

atalog 0600P-0/US ccessories 99- eramic,, & 99- ompact Manifolds, Subbases & ccessories Manifold VM Form ottom Kit Number SPP /" PN-VMM /8" PN-WMM /" PN-YMM VM nd Plates Form Kit Number SPP /8" PN-VMS /" PN-WMS " PN-YM8S Subbase Side s (99- & VM) 99- Kit Number VM Kit NPT SPP SPP /" PL-/-80 PL-/-70 PN-VSS /8" PL-/8-80 PL-/8-70 PN-WSS /" PL-/-80 PL-/-70 PN-YSS Subbase ottom s 99- Kit Number NPT SPP /" P-/-80 P-/-70 /8" P-/8-80 P-/8-70 VM Transition Plate Kit Number PN-VM00K Kit includes: Transition Plate Only. Order PN-VMS and PN-YM8S Separately to ssemble dd--fold H Transition Plate H

atalog 0600P-0/US ccessories 99- Hi-Flow Manifold / Subbase Kits 99-,, & Hi-Flow Manifold / Subbase Kits PS0 0 P asic Series PS0 PS PS nclosures / Lead Length 0 None, No lectrical - 99- Mounting ase Style / Series Subbase: /8 NPT Side s Subbase: /8 SPP Side s 6* Manifold: / NPT nd s Manifold: / SPP nd s * Manifold: /8 NPT nd s Manifold: /8 SPP nd s 6* Manifold: /8 NPT ottom / nd 6 Manifold: /8 SPP ottom / nd 66* * SPP ISO 79 Specifications. # ottom - /". Series Subbase: / NPT Side s 7 Subbase: / SPP Side s 8* Subbase: / NPT ottom / nd 7 Subbase: / SPP ottom / nd 8* Manifold: /8 NPT nd s Manifold: /8 SPP nd s 6* Manifold: / NPT nd 7 Manifold: / SPP nd s 8* Manifold: / NPT ottom / nd 67 Manifold: / SPP ottom / nd 68* Series Subbase: / NPT Side s 9 Subbase: / SPP Side 0* Subbase: / NPT ottom / nd 9 Subbase: / SPP ottom / nd 0* Manifold: / NPT nd 7 Manifold: / SPP nd s 8* Manifold: / NPT nd 9 Manifold: / SPP nd 0 Manifold: / NPT ottom / nd 69 Manifold: / NPT ottom / nd 60* Subbase Kits Manifold Kits

atalog 0600P-0/US ccessories 99- Hi-Flow Manifold ccessories 99-,, & nd Plate Kits PS0 0 0 P asic Series PS0 PS PS nd Plate Kit Type nd Plate, Non-ollective Wiring ngineering Level urrent Thread Type 0 NPT SPP Options 0 Non-ollective Wiring Non-ollective Wiring nd Plates 99-,, & Transition Plate Kits PS0 7 0 0 P asic Series ngineering Level PS0 urrent Transition Plate Type Thread Type to to 0 NPT to 6 SPP to 7 to 8 Options 0 Non-ollective Wiring Interface Plate Transition Plate to Shown Right Hand nd Plate

atalog 0600P-0/US ccessories 99- eramic,, & lanking Plate Kits Kit Number 99- VM PS0P PN- PSP PN- PSP PN- Kit includes: lanking Plate, asket, and Mounting olts. Manifold Isolation Kits Main alley (,, ) Kit Number 99- VM PS0P PN-VK0P PSP PSP PN-WK0P PN-YK0P Kit includes: s with O-rings. Pilot alley H, H, H Main alley Kit Number PS0P H, H, H Pilot alley Kit includes: s with O-rings. Sandwich Flow ontrols Features oth adjustment screws are located on the end of the unit. Sandwich Flow ontrol mounts with its own studs, which means the valve uses standard bolts for mounting. Sandwich Flow ontrol is not to be used as a shut off device and is not bubble tight when needles are fully turned down. -In 99- PS0P PSP PSP Shown

atalog 0600P-0/US ccessories 99- Sandwich Regulators Sandwich Regulators Features Remote ir Pilot Operated for hard-to-reach pressure control. Unregulated Pilot Pressure to valve for consistent valve shifting regardless of pressure adjustment. - (Independent ual Regulator Shown) - (Independent ual Regulator Shown) OL OPTIONS R MOST POPULR PS07 6 6 P asic Series 99- PS07 99- PS7 99- PS7 Regulator Function ommon Pressure Regulator Independent Pressure Regulator Selector Regulator # Regulator / auge* 0** Line y-pass Plate -0 PSI w/o auge -60 PSI w/o auge - PSI w/o auge -0 PSI w/auge -60 PSI w/auge 6 - PSI w/auge ir Pilot w/60 PSI auge ir Pilot w/60 PSI auge * For ommon Pressure Regulator Option, Regulator auge callout must be the same number for both # and #. (xample: 66) ** Pressure Line y-pass Option can only be used with Independent and Selector Regulators (Option & in Sandwich lock Function). Ordering omponents Manifold or Subbase Kit required. Sandwich Regulator Kit configured for Internal Pilot as standard. Order valve as xternal Pilot. How to onfigure Sandwich Regulator / Valve ombinations # Regulator / auge* 0** Line y-pass Plate -0 PSI w/o auge -60 PSI w/o auge - PSI w/o auge -0 PSI w/auge -60 PSI w/auge 6 - PSI w/auge ir Pilot w/60 PSI auge ir Pilot w/60 PSI auge * For ommon Pressure Regulator Option, Regulator auge callout must be the same number for both # and #. (xample: 66) ** Pressure Line y-pass Option can only be used with Independent and Selector Regulators (Option & in Sandwich lock Function). Internal Pilot onfiguration - Pressure in ase feeds regulator configured for Internal Pilot which feeds valve configured for xternal Pilot. xternal Pilot onfiguration -,, n xternal Pilot pressure in or of the base feeds thru the Sandwich Regulator or galley directly to the / pilot of the valve. This configuration takes an xternal Pilot from the port of the base and passes it thru the regulator to feed the galley of the valve.

atalog 0600P-0/US lectrical onnectors (Revised 0-8-08) Female lectrical onnectors / ccessories 0mm Square -Pin ISO 00, IN 60 (Use with nclosure ) 99- eramic,, & onnector onnector escription with 6' (m) ord mm PS08P PS08P Unlighted PS079P PS079P* Light 6-8V, 0/60Hz, 6-8V PS08P PS08P* Light 0V/60Hz PS08P N/ Light 0V/60Hz * L with surge suppression. Note: Max ø6.mm cable size required for connector w/o 6' (m) cord. IP6 rated when properly installed. ngineering ata: onductors: Poles Plus round; able Range (onnector Only): 8 to 0mm (0. to 0.9 Inch); ontact Spacing: 8mm 7mm 8mm 0mm 0mm mm Rectangular -Pin Type Industrial (Use with nclosure ) onnector onnector escription with 6' (m) ord PS9P PS9P Unlighted PS079P PS079P* Light V60Hz, V PS08P PS08P* Light 0V/60Hz PS087P N/ Light 0V/60Hz 0mm 0.mm * L with surge suppression. Note: Max ø6.mm cable size required for connector w/o 6' (m) cord. IP6 rated when properly installed. ngineering ata: onductors: Poles Plus round; able Range (onnector Only): 6 to 8mm (0. to 0. Inch); ontact Spacing: mm mm mm 0mm NOMO Operator dapter escription Operator dapter Kit Number PS8P 99- NOMO Solenoid Kits Voltage ode Quantity -Pin 0mm L oil Kit -Pin M uro 6 oil Kit 9 PS8869P PF PF 9 PF9 PF 7 PF7 6

atalog 0600P-0/US Pilot onversion Instructions 99- eramic,, & / / Internal / xternal Pilot onversion Instructions NOT: For Single Solenoid & ouble Solenoid oth & end askets must be converted and both & ports in the Manifold & Subbase must have external pilot supplied. Remove Solenoid ssembly, NOMO Operator dapter asket Position of asket for Internal Pilot When Using With Solenoid Operator Remove asket and Rotate to Show I in Position as Shown and Reinstall asket and overs. (Valve is Now xternal Pilot) 7

atalog 0600P-0/US imensions 99- eramic,,, ir Operated Valves Series Inches (mm).7 (0). (0) 6.69 (70).6 (). ().68 (68).8 (7).0 (8.).80 (7).0 ().0 ().0 () Solenoid Operated Valves Series Inches (mm) 7.97 (0.) 8.8 (8) 9.7 (.). (.).86 (.). (6).69 (9). (0).6 (.). ().98 (6.).7 (9) 8

atalog 0600P-0/US imensions 99- & VM Subbases VM & 99- Side ed Subbase /8 Inch s & For xternal Pilot ia. H VM 99- ia. Places F K Series Part Number F H K PN-VSS SPP /. (0).89 (8).9 (9).9 (9).7 ().6 (). (.6).9 (9.9) VM PN-WSS SPP /8.88 (). (6). (6). (6). (6).7 (0) 0.6 (6.6). () PN-YSS SPP /.87 (9).80 (7).68 (68).68 (68).9 (7.).0 () 0.6 (6.6) 0.7 (8) PL-/-70 SPP /..8.9.9.7. 0. (0) (6) (9) (9) () (9) (.) 0. PL-/-80 NPT / (6) PL-/8-70 SPP /8 99-.88..7.7..6 0. () (6) () () (6) (7) (.) 0. PL-/8-80 NPT /8 (6) PL-/-70 SPP /.87.80.68.68.9.6 0.6 (9) (7) (68) (68) (7.) (60) (6.6) 0.7 PL-/-80 NPT / (8) Inches (mm) 99- ottom ed Subbase F H () ottom s ottom ed Subbase Series Part Number H F P-/-70 SPP /. P-/-80 NPT/ (0).8 (6).9 (9).9 (9). (9). (6) 0. (.) P-/8-70 SPP /8.88 P-/8-80 NPT/8 ().0 (6).7 ().7 ().6 (7). (6).0. (.) Inches (mm) 9

atalog 0600P-0/US imensions 99- Hi-Flow Subbase Side ed Subbase / Inch onduit, (.) Mtg. Holes () F c of ase L /8 Inch s & For xternal Pilot () Side s ottom ed Subbase F () ottom s PS0 Subbase.8 (8).9 (8) Inches (mm).8 (8) F.7 (0).0 (6).00 ().86 (98) / Inch onduit c of ase L /8 Inch s & For xternal Pilot () Side s PS Subbase 6.69 (70). (9). (80). (08) Side ed Subbase F ottom ed Subbase F () ottom s. (07) Inches (mm) F.07 ().6 (6) 7, (.8) Mtg. Holes () PS Subbase / Inch onduit c of ase L () Side s /8 Inch s & For xternal Pilot 7.90 (0). () Inches (mm).96 (7) F.0 (6).90 (990). (8).9 () Side ed Subbase F ottom ed Subbase F 9,0 (.) Mtg. Holes () () ottom s 0

atalog 0600P-0/US imensions 99- Hi-Flow Manifolds c Lof ase () /8 Inch Pilot PS0 Manifold Inch onduit onnection / Inch s, & F + ( x n) + ( x n) n = Number of Stations Manifold with Optional ollective Wiring System 6.0 (6). (8).0 (6). (08).9 (9) F.87 (). () F.6 (6) 7. (8) F.90 () ottom ed Manifold () ottom s 7 (.8) Mtg. Holes () F + ( x n) F + ( x n) + ( x n) + ( x n) n = Number of Stations F, = lank nd Plate F, = Top nd Plate.80 (6) *.6 (6) *.6 (8) Inches (mm) * For 9-Pin Round onnector Module, add.08" (7.mm) to the & dimensions. c L of ase /8 Inch Pilot s PS Manifold 8.6 (). (8).0 (6).9 () 9. (9) -/ Inch onduit onnection ottom ed Manifold () / Inch s (.7) Mtg. Holes () F + ( x n) + ( x n) n = Number of Stations Manifold with Optional ollective Wiring System F + ( x n) F + ( x n) + ( x n) + ( x n).7 ().6 (60).8 () *. (87) F.8 (0) *.88 (99) F.06 (7) Inches (mm) * For 9-Pin Round onnector Module, add.08" (7.mm) to the & dimensions. F.0 () n = Number of Stations F, = lank nd Plate F, = Top nd Plate c L of ase /8 Inch Pilot s PS Manifold -/ Inch onduit onnection () Inch s F + ( x n) + ( x n) n = Number of Stations Manifold with Optional ollective Wiring System 0. (6).9 ().60 (6). (0) 6.6 (9) *. (90).80 (7) F.0 () *.9 ().6 (7) F. (9).6 (9) F.9 () ottom ed Manifold (.7) Mtg. Holes () F + ( x n) F + ( x n) + ( x n) + ( x n) Inches (mm) * For 9-Pin Round onnector Module, add.08" (7.mm) to the & dimensions. n = Number of Stations F, = lank nd Plate F, = Top nd Plate

atalog 0600P-0/US imensions 99- VM Manifolds 99- VM Form Manifold & 99- VM - Form nd Plates c of ase L H L ia. Mtg. Holes () /8 Inch s & For xternal Pilot ia. s, & F + ( x n) + ( x n) n = Number of Stations ottom ed Manifold K ia. s & VM Form Manifold Series Part Number F K PN-VMM PN-WMM PN-YMM. (0). () 7.8 (90).8 (6).8 (7).0 (6) 0.9 () 0.9 (). ().69 ().0 (6).80 (7) 0. () 0. () 0.9 () 0.87 ().0 (6).8 (0).7 ().0 ().6 (60) SPP /8 SPP / SPP / SPP /8 SPP SPP / VM Form nd Plate Series Part Number H L Inches (mm) PN-VMS PN-WMS PN-YM8S. (0). () 7.8 (90).8 (6).8 (7).0 (6) 0.9 () 0.9 (). ().0 (8).8 ().0 () 0. () 0.69 (8).0 (6) 0.87 ().0 (6).8 (0) 0.8 (7) 0. (9) 0.7 ()

atalog 0600P-0/US lobal Pneumatics, Warning, Offer of Sale Pneumatic Products lobal Pneumatics This icon can be found next to products that are widely supported by Parker Pneumatics worldwide manufacturing and sales network. When you see this icon, you can be confident that this product is manufactured and / or stocked* worldwide for rapid delivery. In addition to local manufacturing or inventory, our sales network has been specifically trained on these products to provide our customers with the best possible service. Products not showing this icon are still sold and distributed worldwide. However, The lobal Pneumatics icon represents products that customers can expect the best level of support. If you are a multi-national company, seek global sourcing or ship globally, depend on Parker Pneumatic for PRMIR USTOMR SRVI. * Stocking levels vary by country! WRNIN FILUR OR IMPROPR SLTION OR IMPROPR US OF TH PROUTS N/OR SYSTMS SRI HRIN OR RLT ITMS N US TH, PRSONL INURY N PROPRTY M. This document and other information from, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application including consequences of any failure, and review the information concerning the product or system in the current product catalog. ue to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by and its subsidiaries at any time without notice. Offer of Sale The items described in this document are hereby offered for sale by, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled Offer of Sale. opyright 007-997,. ll Rights Reserved.

atalog 0600P-0/US Safety uide Pneumatic Products Warnings Safety uide For Selecting nd Using Products nd Related ccessories! WRNIN: FILUR OR IMPROPR SLTION OR IMPROPR US OF PNUMTI IVISION PROUTS, SSMLIS OR RLT ITMS ( PROUTS ) N US TH, PRSONL INURY, N PROPRTY M. POSSIL ONSQUNS OF FILUR OR IMPROPR SLTION OR IMPROPR US OF THS PROUTS INLU UT R NOT LIMIT TO: Unintended or mistimed cycling or motion of machine members or failure to cycle Work pieces or component parts being thrown off at high speeds. Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device. xplosion Suddenly moving or falling objects. Release of toxic or otherwise injurious liquids or gasses. efore selecting or using any of these Products, it is important that you read and follow the instructions below. Y. NRL INSTRUTIONS.. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Valves, FRLs (Filters, Pressure Regulators, and Lubricators), Vacuum products and related accessory components... Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. esign all systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons or property.. Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see: ISO :998, Pneumatic Fluid Power eneral Rules Relating to Systems. See www.iso.org for ordering information... istribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. o not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Parker publications for the products considered or selected... User Responsibility: ue to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Parker and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through its own analysis and testing, is solely responsible for: Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory. ssuring that all user s performance, endurance, maintenance, safety, and warning requirements are met and that the application presents no health or safety hazards. omplying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which the valves, FRLs or Vacuum products are used; and, ssuring compliance with all applicable government and industry standards..6. Safety evices: Safety devices should not be removed, or defeated..7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured..8. dditional Questions: all the appropriate Parker technical service department if you have any questions or require any additional information. See the Parker publication for the product being considered or used, or call -800-PRKR, or go to www.parker.com, for telephone numbers of the appropriate technical service department.. PROUT SLTION INSTRUTIONS.. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system. System components need to be able to provide adequate flow and pressure for the desired application... Pressure Rating: Never exceed the rated pressure of a product. onsult product labeling, catalogs or the instruction sheets supplied for maximum pressure ratings... Temperature Rating: Never exceed the temperature rating of a product. xcessive heat can shorten the life expectancy of a product and result in complete product failure... nvironment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic ivision products are designed for use in general purpose industrial applications. If these products are to be used in unusual circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to premature failure of a product... Lubrication and ompressor arryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. onsult the factory or product literature for materials of construction..6. Polycarbonate owls and Sight lasses: To avoid potential polycarbonate bowl failures: o not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or temperatures outside of the rated range. o not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols. o not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as phosphate ester and di-ester lubricants. Y0

atalog 0600P-0/US Safety uide Pneumatic Products Warnings.7. hemical ompatibility: For more information on plastic component chemical compatibility see technical bulletins Tec-, Tec-, and Tec-.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage. o not connect pressure regulators or other products to bottled gas cylinders. o not exceed the maximum primary pressure rating of any pressure regulator or any system component. onsult product labeling or product literature for pressure rating limitations.. PROUT SSMLY N INSTLLTION INSTRUTIONS.. omponent Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be performed. ll components must be checked for correct style, size, and catalog number. O NOT use any component that displays any signs of nonconformance... Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling -800-PRKR, or at www.parker.com... ir Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient temperature can drop below freezing. VLV N FRL MINTNN N RPLMNT INSTRUTIONS.. Maintenance: ven with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or replacement of products so that products are replaced before any failure occurs. maintenance program must be established and followed by the user and, at minimum, must include instructions. through.0... Installation and Service Instructions: efore attempting to service or replace any worn or damaged parts consult the appropriate Service ulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling -800-PRKR, or by accessing the Parker web site at www.parker.com... Lockout / Tagout Procedures: e sure to follow all required lockout and tagout procedures when servicing equipment. For more information see: OSH Standard 9 FR, Part 90.7, ppendix, The ontrol of Hazardous nergy (Lockout / Tagout).. Visual Inspection: ny of the following conditions requires immediate system shut down and replacement of worn or damaged components: ir leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an indication of worn or damaged components. amaged or degraded components: Look to see if there are any visible signs of wear or component degradation. Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior. ny observed improper system or component function: Immediately shut down the system and correct malfunction. xcessive dirt build-up: irt and clutter can mask potentially hazardous situations. aution: Leak detection solutions should be rinsed off after use... Routine Maintenance Issues: Remove excessive dirt, grime and clutter from work areas. Make sure all required guards and shields are in place..6. Functional Test: efore initiating automatic operation, operate the system manually to make sure all required functions operate properly and safely..7. Service or Replacement Intervals: It is the user s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum products contain components that age, harden, wear, and otherwise deteriorate over time. nvironmental conditions can significantly accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals need to be established based on: Previous performance experiences. overnment and / or industrial standards. When failures could result in unacceptable down time, equipment damage or personal injury risk..8. Servicing or Replacing of any Worn or amaged Parts: To avoid unpredictable system behavior that can cause death, personal injury and property damage: Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSH Lockout Tagout procedures (OSH Standard 9 FR, Part 90.7, ppendix, The ontrol of Hazardous nergy Lockout / Tagout). isconnect electrical supply (when necessary) before installation, servicing, or conversion. isconnect air supply and depressurize all air lines connected to system and products before installation, service, or conversion. Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how pneumatic products are to be applied. fter installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or system into use. Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local representative for replacement labels..9. Putting Serviced System ack into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions supplied with the valve FRL or vacuum component to insure proper function of the system. Y Y