Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Similar documents
Pipetted Liquid Sampling. Automated sample preparation platform for online LC-MS/MS bioanalysis

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

SPE Manifolds and Accessories

Agilent Multimode Inlet for Gas Chromatography

Stability Axial Compression Technology Application Ordering Information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Quick Reference Guide. Supplies for Waters HPLC Systems

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Set Your Sights on Superior Performance

Set Your Sights on Superior Performance

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Determination of Sudan Dyes I IV in Curry Paste

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Technical Overview. Introduction

Application Note. Abstract. Authors. Environmental Analysis

Comparison of LC/MS/MS and GC/MSD Analyses of Pesticide Residues in Food Products when Using the QuEChERS Sample Preparation Technique

High-Performing Restek PAL SPME Fibers

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Universal Vacuum Manifold Assembly UCT. Patent No.: US 7,438,862 B2 INNOVATION THROUGH CHEMISTRY

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

High Recovery Method of HybridSPE - Phospholipid for Cleanup of Biological Samples Prior to LC-MS Analysis

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

n multi-residue analysis of pesticides olfgang Schwack, Claudia Oellig niversity of Hohenheim

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

a 3M company Zeta Plus Encapsulated System Innovative Filtration Convenient. Scalable. Disposable.

S 1125 HPLC Pump System

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

CAPS FOR SAMPLE STORAGE TUBES BROCHURE. Screw Caps & Push Caps 30 YEARS OF EXPERIENCE SERVING SCIENTISTS IN TRACEABLE SAMPLE SINCE 1984 STORAGE

Various filter sheet series and grades are available for coarse, polish, clarifying, sterile, and pre-membrane filtration applications.

5 µm Preparative HPLC Columns

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY

Setting up SilFlow for BackFlush in your GC

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent

Agilent 7693A Automated Liquid Sampler

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

IFPAC 2003 Dr. Berthold Andres

Ultra High Performance Fittings. Fittings Connectors Kits

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

VERITY Purification Systems Build the perfect system to fit your research

Using the PSD for Backflushing on the Agilent 8890 GC System

HIGH PRESSURE SWITCHING VALVES

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

The next level of True Blue Performance

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Agilent G5632 Valve Kit Instructions

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Practical Steps in GC Troubleshooting

NEW HPLC - SYSTEM LINE

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

QuickSplit TM Flow Splitters

Universal Pipette Tips Ultra-clear and certified RNase/DNase-free

Evaluation of Total Petroleum Hydrocarbon in Soil Using LC with Fraction Collector and GC/MS

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

MIXPAC TM DB 2K Cordless two-component dispenser

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

STABILITY AND RELIABILITY: NEW APPROACHES IN PREPARATIVE HPLC COLUMN DESIGN

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

APPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES

FITTINGS, LOOPS, AND VALVE ACCESSORIES

Cleaner Air Comes From Within

A LEADING MANUFACTURER OF ABSOLUTE RATED FILTERS

Pyrolytic Graphite Platforms

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

3M Purification Product Brochure. CUNO CTG System. Clean and Economical

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

Fixed Flow Splitter *

Agilent Biomass Solutions SUSTAIN YOUR PRODUCT QUALITY AND COMPETITIVE EDGE

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

SiliCycle MiniBlock XT

PORTAFOLIO DE CROMATOGRAFÍA LABINS

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

> Boosting the performance of LC/MS/MS analysis of mycotoxins and their transformation products by use of innovative separation techniques

THE CLEANEST FUEL. PERIOD.

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

AZ Chrom s.r.o.

Clarigard Filters High-performance filters for the clarification and prefiltration of process fluids

Competitive Comparison Maximize Performance and Minimize Maintenance with Agilent LC Spares

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

ACE. Intelligent Solutions for Method Development. Method Development Kits. ACE UHPLC and HPLC Columns

RINSEGARD HP AND HPX. Simultaneously removes trace levels of positively charged ions and fine particles in ultrapure DI water

The Only No Compromise

Transcription:

Accuracy Starts Here Agilent Captiva Filtration Selection Guide

TAbLe of CoNTeNTS Tips & Tools Learn the core concepts surrounding Solid Phase Extraction and best practices for Sample Prep. View the video at www.agilent.com/chem/spevideo Learn about the new generation of polymeric SPE products, Agilent Bond Elut Plexa. Request the brochure using publication number 5990-8589EN. 3 Captiva Filtration 4 Captiva ND 6 Captiva ND Lipids 8 Captiva 96-well Filter Kits 9 Captiva 96-well Filter Plates 10 Captiva 96-well Collection Plates and Cover 11 Captiva Filter Cartridges 11 CaptiVac Vacuum Collars

Captiva's unique dual-depth filtration media provides complete removal of precipitated proteins and outstanding resistance to sample clogging, with no loss of analytes. All Captiva components are ultra clean, and rigorously tested to ensure against non-specific binding. With Captiva, your plasma samples are processed quickly and reliably. Captiva is easily automated for enhanced productivity and excellent for sample storage. Time-consuming sample transfer steps required with conventional precipitation are now a thing of the past. With Captiva, clean, clear filtrates are ready for injection in minutes this user-friendly filtration device is simple and streamlined with an easy-to-follow 3-step process. And because Captiva samples are pellet-free, you can sample directly from the collection plate. The Captiva range includes: ü Captiva ND non-drip filtration plates for organic-based protein precipitation ü Captiva ND Lipids non-drip filtration plates for lipid and protein depletion ü Captiva 96-well filter plates for general sample filtration ü Captiva filter cartridges, all the usual Captiva benefits in a standard SPE cartridge format www. AGiLeNT. Com/ Chem/ SAmPLePreP 3

Captiva ND Filtration Plates Agilent now offers the Captiva ND family of non-drip filtration plates: Captiva ND A simple-to-use filtration device designed for high-throughput, automated, in-well protein precipitation. built with a unique non-drip (ND) membrane, Captiva ND plates allow for solvent-first protein precipitation using methanol or acetonitrile. Captiva's unique dual filter design offers fast uniform flow while avoiding sample loss and filter plugging. Captiva ND Lipids Specifically designed for LC/mS bioanalysis of plasma, Captiva ND Lipids combine the ease of use and superior flow properties of Captiva ND with a unique chemical filter. The plate efficiently removes ion-suppressing phospholipids, proteins, and surfactant interferences from precipitated plasma samples. Operating Instructions and Tips for Captiva ND and Captiva ND Lipids 96-well Plates Add Precipitate Filter Solvent first Then plasma Key Salts Proteins Lipids Analyte *Note: The diagram shows lipids being extracted on the Captiva ND Lipids product. Captiva ND does not remove lipids. 4 AGiLeNT CAPTiVA FiLTrATioN SeLeCTioN GuiDe

Captiva ND easy automation non-drip design resists organic solvent flow until vacuum is applied exceptional flow dual depth filter avoids plugged membranes and lost samples efficient protein removal ms-suitable samples in as little as 1/5th the time Captiva ND's unique non-drip design simplifies your workflow, ends the need to use messy tip or well seals, and reduces the number of liquid transfer steps needed to process samples. best of all, Captiva ND's dual-depth filter construction delivers a fast reproducible flow, so you get uniform sample treatment and reliable filtrate recovery in a fraction of the time of other protein precipitation plates. Captiva ND Description Unit Part No. Capitiva ND plate, 0.2 µm, polypropylene 5/pk A5969002 recommended for both methanol and acetonitrile Capitiva ND plate, 0.45 µm, polypropylene Suitable for acetonitrile only 5/pk A5969045 Get fast, reproducible flow with Agilent Captiva ND 300 250 Flow Rate Consistency (100 µl Plasma w/400 µl ACN) Captiva ND Competitor 1 Competitor 2 Filtration Time (sec) 200 150 100 50 Agilent Captiva ND plates process samples quickly and uniformly without the need for positive pressure manifolds. Plus, its uniform flow facilitates vacuum processing making it more automation friendly. 0 0 10 20 30 40 50 60 70 80 90 100 Well Address www. AGiLeNT. Com/ Chem/ SAmPLePreP 5

Captiva ND Lipids more precise and reproducible quantitation with removal of phospholipids and proteins increased productivity due to extended column lifetimes and cleaner ms ion sources Simple 3-step procedure Capitiva ND Lipids is as simple and easy-to-use as a standard protein precipitation plate. The non-drip 96-well filtration plate is specially designed to effectively remove phospholipids from biofluids. Captiva ND Lipids removes lipids, proteins, surfactants and other matrix interferences from plasma extracts. ion suppression is significantly reduced for enhanced sensitivity and precision during trace analysis. The depletion of lipid compounds also gives you better peak shapes and reproducible retention times so that standard operating procedures are easily validated. in addition, the fast, in-well precipitation technology of Captiva ND Lipids ensures high sample throughput and helps reduce instrument downtime, with virtually no need for method development on a wide range of analytes. Captiva ND Lipids Description Captiva ND Lipids 96-well filtration starter kit includes 1 CaptiVac vacuum collar, 2 Captiva ND Lipids filter plates, 2 Captiva 96 deep-well 1 ml collection plates and 2 Captiva collection plate pierceable covers Captiva ND Lipids 96-well filtration replacement kit includes 2 Captiva ND Lipids filter plates, 2 Captiva 96 deep-well 1 ml collection plates and 2 Captiva collection plate pierceable covers Captiva ND Lipids 96-well filter plate, 1 ml well Captiva ND Lipids 96-well filter plates, 1 ml well, 5/pk DuoSeal 96 96-well plate seals, 10/pk Part No. A59640002SK A59640002rK A59640002i A59640002V A8961008 Tips & Tools Using Captiva ND Lipids with methanol is an excellent replacement for acetonitrile as the precipitation solvent. Methods with methanol show better removal of lipids than with acetonitrile. Converting to methanol is advantageous when the supply or cost of acetonitrile is restrictive. Methanol can now be your solvent of choice for lipid removal. 6 AGiLeNT CAPTiVA FiLTrATioN SeLeCTioN GuiDe

Post-column infusion (PCI) of albuterol before treatment with Captiva ND Lipids Note that the ion-suppression features (top trace) correlate with the elution of phospholipids (bottom trace). PCi ms lipid trace Same experiment after protein and lipid depletion with Captiva ND Lipids PCi ms lipid trace ion suppression is dramatically reduced and the lipids are almost non-detectable. Longevity Study Illustrating Prolonged Column Lifetime When Using Captiva ND Lipids Pindolol Atenolol Propranolol 10th injection tr = 0.907 min 2721 psi 5010th injection tr = 0.908 min 2914 psi Atenolol Pindolol Propranolol 10th injection tr = 0.924 min 2721 psi 5010th injection tr = 0.924 min 2914 psi No significant changes in back pressure, retention time, and peak shape with Captiva ND Lipids after 10 and 5010 injections for LC/mS or LC/mS/mS bioanalysis (top = uv detection; bottom = ms detection). www. AGiLeNT. Com/ Chem/ SAmPLePreP 7

Captiva 96-well Filter Kits The industry standard for centrifugation-free sample filtration Fast and reliable processing improves productivity Starter kits contain everything you need Faster than centrifugation and easily automated, Captiva's unique dual-depth filtration media provides outstanding resistance to sample clogging. with Captiva, your samples are processed quickly and reliably, and you can avoid fibrinogen clogging forever. The plates are also excellent for sample storage. All Captiva components are ultra clean, and rigorously tested to ensure against non-specific binding. Starter kits contain everything you need to get up and running with minimum fuss. replacement kits include everything you need to replenish your Captiva system. Captiva 96-well filter kit Captiva 96-well Filter Kits Pore Size (µm) Filter Material Part No. Starter Kits 0.2 Polypropylene A5960002SK 0.45 Polypropylene A5960045SK includes 1 CaptiVac vacuum collar, 5 Captiva filter plates, 10 DuoSeal 96 96-well plate seals, 5 Captiva 96 deep-well 1 ml collection plates, 5 Captiva collection plate pierceable covers Replacement Kits 0.2 Polypropylene A5960002K 0.45 Polyvinyldifluoride and A5967045K polypropylene Polypropylene A5960045K includes 5 Captiva filter plates, 10 DuoSeal 96 96-well plate seals, 5 Captiva 96 deep-well 1 ml collection plates, 5 Captiva collection plate pierceable covers 8 AGiLeNT CAPTiVA FiLTrATioN SeLeCTioN GuiDe

Captiva 96-well Filter Plates Protect hplc columns from clogging to reduce instrument downtime Clean and clear filtrates offer improved sensitivity high analyte recovery with simple robust methods allows faster method development Filtration is simple, versatile, and necessary to prevent clogging of valuable hplc columns. Captiva 0.2 µm and 0.45 µm depth filter plates are ideal for filtering samples prior to LC/mS injection. Captiva 10 µm and 20 µm glass fiber filter plates are designed for clarifying highly particle-laden samples, such as freshly thawed plasma and hepatocyte filtration, preventing sample transfer problems from pipette tip clogging. They are perfect for automated systems and for use with DuoSeal 96 96-well seals. Captiva 96-well Filter Plates, 5 x 96 well Pore Size (µm) Filter Material Part No. 0.2 Polypropylene A5960002 0.45 Polyvinyldifluoride and A5967045 polypropylene Polypropylene A5960045 10 Glass fiber A596401000 20 Polypropylene A596002000 Polypropylene bulk Pack, 100 x 96 well A596002000b www. AGiLeNT. Com/ Chem/ SAmPLePreP 9

Captiva 96-well Collection Plates and Cover Designed for Captiva filtration, SPeC and bond elut 96 applications Standard 1 ml format offers compatibility with further automation or liquid handling Silicone cover preserves sample integrity Captiva 96-well collection plates are specially designed for use with Captiva filtration plates, SPeC SPe 96-well plates and bond elut 96-well plates. The 1 ml capacity provides the volume needed to collect all of your filtrate or eluate. Captiva pierceable 96-well silicone covers are easily applied to completely seal the plates, ensuring no sample loss due to spillage or evaporation and no sample contamination. The silicone is specially designed for 96-well auto injectors, providing easy piercing and removal. Captiva 96-well Collection Plates and Cover Description Unit Part No. Captiva 96-deep well collection plate, 1 ml 10/pk A696001000 Captiva pierceable 96-well collection plate cover 10/pk A8961007 DuoSeal 96 10/pk A8961008 Captiva 96-well collection plate, A696001000 10 AGiLeNT CAPTiVA FiLTrATioN SeLeCTioN GuiDe

Captiva Filter Cartridges Standard SPe format ideal for LC/mS samples Avoid sample transfer problems Captiva filter cartridges bring all of the benefits of Captiva filtration to the standard SPe cartridge format. The 0.2 µm and 0.45 µm filter cartridges are ideal for preparing precipitated protein samples for LC/mS analysis. The Captiva 10 µm glass fiber filter cartridge is designed for clarifying highly particle-laden samples, such as freshly thawed plasma, preventing sample transfer problems due to pipette tip clogging. Captiva Filter Cartridges Pore Size Filter Material (µm) 0.2 Polyvinyldifluoride and polypropylene 0.45 Polyvinyldifluoride and polypropylene Volume (ml) Unit Part No. 3 100/pk A5300002 3 100/pk A5307045 10 Glass fiber 10 100/pk A500401000 Captiva filter cartridges, glass fiber, A500401000 CaptiVac Vacuum Collars Pre-aligned for trouble-free operation Vacuum sealed for maximum efficiency Simple, cost effective solution For use with Captiva Filtration and SPeC 96-well Plates, this patented vacuum collar is a completely transparent device that joins Captiva or SPeC plates directly onto our collection plate. The unique design of the Captiva collar forms a pre-set, pre-aligned vacuum seal between the filtration and collection plate, which positions the outlet tips at a specified distance inside each well, so as to prevent cross contamination of samples. CaptiVac Vacuum Collars Description CaptiVac vacuum collar CaptiVac gasket kit, 5/pk Part No. A796 A796G CaptiVac vacuum collar, A796 www. AGiLeNT. Com/ Chem/ SAmPLePreP 11

Your tough applications demand Agilent instruments, columns and supplies As the world's chromatography leader, Agilent offers you the widest selection of instruments, columns and supplies. All are engineered or selected by our experienced design teams, manufactured to demanding specifications, and tested under strict conditions. Unsurpassed instrumentation for tough qualitative and quantitative analysis Agilent-engineered supplies for peak instrument performance: From best-in-class LC technologies to ms spectral accuracy and precision to ToF-mS systems that let you identify empirical formulas without a spectral library, Agilent LC/mS instruments help you perform discovery, quantitation, and target compound analysis with confidence. A wide portfolio for GC, LC, ms, and atomic and molecular spectroscopy Agilent CrossLab, a portfolio of GC supplies for all major brands of analytical instruments ms analyzed vial kits, ultra inert inlet liners, and other innovative supplies Columns and standards for maximum confidence in your results: ZorbAX, Poroshell, biocolumns for hplc and uhplc, Flash Purification, prep columns and media, too GPC/SeC columns and standards including PLgel, PL aquagel-oh, specialty columns and easivial standards Agilent J&w GC columns including ultra inert, high efficiency, Select and PoraboND PLoT Custom columns for unique applications information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, inc. 2011 Printed in the usa october 27, 2011 5990-8588eN How to contact Agilent For the latest information on the complete line of Agilent Technologies columns and supplies: Visit our web site at www.agilent.com/chem Contact your local Agilent sales office Contact your local Agilent Authorized Distributor