technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

Similar documents
technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems MXS-B Multi Application Split Sky Air

Outdoor Units R-410A ARX-GV1B

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

Split-Sky Air RMX-JZ Super Multi Plus

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

Split-Sky Air FAYP-B Wall Mounted Unit

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

Air Conditioning Technical Data RZQG-L(8)Y1

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

Air Conditioning. Technical Data EEDEN RXZ-N

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Air Conditioners Technical Data

Air Conditioning. Technical Data EEDEN RXJ-L

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning Technical Data RZQSG-L3/9V1

WCA4**4. Product Specifications

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

N4A6. Product Specifications

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Technical Service Manual

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

N4A4 C. Product Specifications

CSA6. Product Specifications. SoftSound SXC 2600

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

Compact Four-way Cassette Type

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Service manual MIV V4+ Indoor units

High Wall Type ( 2 Series )

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

FFQN-C, FCRN-E, FFRN-C

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Fan Coil Units. Technical Data

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

S/T Ratio. Input BTU/h

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

Engineering Data Book

Low Static Pressure Duct(V shape evaporator)

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Tons BTU/h S.E.E.R* E.E.R** HSPF

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Engineering Data Book

SERVICE MANUAL OUTDOOR UNIT. No. OB386

R4H4. Product Specifications

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

Low Static Pressure Duct (V shape evaporator)

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

FMU4X, FMC4X FMU4Z, FMC4Z

Outdoor Units, 50Hz, R410A

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

BAC / BHC Product Specifications

HCH6. Product Specifications

Oil Cooler AKZ328-D142 PL

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

FTXS50EV1B, FTXS60EV1B (RoHS application) FTXS50EV1B, FTXS60EV1B Wiring Diagram

TSA6. Product Specifications. SmartComfort TXC 5600

Bosch BOVA Split System Heat Pump

DESCRIPTION FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

PHR5. Product Specifications

SINGLE. Technical Data Book. Big Duct for Europe (R410A, 50Hz, H/P) Model : AC180JNHPKH/EU AC180JXAPNH/EU AC200JNHPKH/EU AC200JXAPNH/EU

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Transcription:

technical data RKS-C RKS-B Pair Application, Inverter Controlled Unit air conditioning systems Split Sky Air

Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Specifications are subject to change without prior notice. Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE04-/2 02/2004 Prepared in Belgium by Goekint Graphics

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB TABLE OF CONTENTS RKS-C / RKS-B Features... 2 2 Specifications... 3 Technical specifications Electrical specifications 3 Capacity tables... 8 4 Dimensional drawings... 5 5 Operation range... 6 6 Piping diagrams... 7 7 Wiring diagrams... 9 8 Sound level... 20 Sound level data Sound pressure spectrum 9 Accessories... 22 Standard accessories Optional accessories 0 Center of gravity... 23 Installation... 25 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB Features s for pair application + Daikin outdoor units can be mounted easily on a roof or terrace or simply placed against an outside wall. They are fitted with a swing compressor, renowned for its low noise and high energy efficiency. 2 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 2 Specifications TECHNICAL SPECIFICATIONS OUTDOOR UNITS RKS20CVMB RKS25CVMB RKS35B/CVMB DIMENSIONS Unit H mm 550 W mm 765 D mm 285 WEIGHT kg 3 COLOUR Unit Ivory white SOUND LEVEL Sound pressure () (Cooling) high/low db(a) 46/43 46/43 47/44 Sound power (2) (Cooling) high db(a) 6 6 62 FAN Air flow rate (Cooling) high/low m 3 /min 36.2/27.4 36.2/27.4 33.4/24.9 Speed (Cooling) high rpm 860 860 860 low rpm 660 660 660 Model Propeller fan Motor output W 3 HEAT EXCHANGER Type WH fin, J7Hi-XA tube Rows x stages x fin pitch mm 2 x 2 x.4 2 x 24 x.4 REFRIGERANT CIRCUIT Refrigerant type R-40A Refrigerant charge kg 0.80 0.80.00 Maximum allowable distance between indoor m and outdoor 20 20 20 Maximum allowable level difference m 5 5 5 Refrigerant control Motor operated expansion valve COMPRESSOR Type Hermetically sealed swing type Model YC23NXD#A Motor output 600 Oil type FVC50K Oil charge volume! 0.375 PIPING CONNECTIONS liquid mm φ6.4 gas mm φ9.5 drain mm φ8.0 INSULATION MATERIAL Heat insulation Both liquid and gas pipes 2 ELECTRICAL SPECIFICATIONS OUTDOOR UNITS RKS20CVMB RKS25CVMB RKS35B/CVMB CURRENT Nominal running current cooling A 2.62 3.72 4.72 Max. running current cooling A Please refer to electrical data Starting current cooling A 3.5 4.4 5.4 OUTDOOR UNITS RKS20CVMB RKS25CVMB RKS35B/CVMB POWER SUPPLY VM NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 Voltage V 230 3D044242B 3D044243B 3D044244B NOTES The sound pressure level is measured in an anechoic room at m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 8 of this chapter. 2 The sound power level is an absolute value indicating the power which a sound source generates. Split - Sky Air Outdoor Units 3

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 2 Specifications 2 TECHNICAL SPECIFICATIONS OUTDOOR UNITS RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 DIMENSIONS Unit H mm 735 W mm 825 D mm 300 WEIGHT kg 49 53 55 COLOUR Unit Ivory white SOUND LEVEL Sound pressure () (Cooling) high/low db(a) 47/* 49/* 52/* Sound power (2) (Cooling) high db(a) 63 64 66 FAN Air flow rate (Cooling) high/low m3/min 47.7/44. 47.6/44. 5.5/4.5 Speed (Cooling) high rpm 700 730 790 low rpm 650 680 650 Model Propeller fan Motor output W 53 HEAT EXCHANGER Type Waffle fin, J 8 Hi-XA tube Rows x stages x fin pitch mm x 32 x.6 2 x 32 x.8 REFRIGERANT CIRCUIT Refrigerant type R-40A Refrigerant charge kg.20.70.70 Maximum allowable distance between indoor m and outdoor 30 Maximum allowable level difference m 20 Refrigerant control - COMPRESSOR Type Hermetically sealed swing type Model 2YC32HXD 2YC45BXD Motor output,500,500,900 Oil type FVC50K Oil charge volume! 0.65 0.65 0.75 PIPING CONNECTIONS liquid mm φ6.4 gas mm φ2.7 φ5.9 drain mm φ8.0 INSULATION MATERIAL Heat insulation Both liquid and gas pipes * This information was not available at the time of publication. ELECTRICAL SPECIFICATIONS OUTDOOR UNITS RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 CURRENT Nominal running current cooling A 6.82 9.2 0.90 Max. running current cooling A Please refer to electrical data Starting current cooling A 7.3 9.3. OUTDOOR UNITS RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 POWER SUPPLY VM VM VM NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 50 50 Voltage V 230 230 230 3D04078A 3D040782A 3D040783A NOTES The sound pressure level is measured in an anechoic room at m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 8 of this chapter. 2 The sound power level is an absolute value indicating the power which a sound source generates. 4 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 2 Specifications ELECTRICAL DATA 2 RKS+FTKS20C unit FTKS20CVMB RKS20CVMB 50-230 2 5 38 2.8 3 0.20 8 0.20 RKS+FTKS25C unit FTKS25CVMB RKS25CVMB 50-230 2 5 5 3.9 3 0.20 8 0.20 RKS+FTKS35C unit FTKS35CVMB RKS35CVMB 50-230 2 5 77 4.9 35 0.22 8 0.20 RKS+FTKS50B unit FTKS50BVMB RKS50BVMB9 50-230 8 20 72 6.92 53 0.8 40 0.6 RKS+FTKS60B RKS+FTKS7B unit FTKS60BVMB RKS60BVMB9 50-230 8 20 72 8.86 53 0.24 43 0.6 FTKS7BVMB RKS7BVMB9 50-230 RKS+FVKS25B 3D0444 3D0445 3D0446 3D040876 6.8 20 80 0.58 53 0.26 43 0.8 unit FVKS25BVMB RKS25BVMB 50-230 5 5 49 3.25 9 0.35 28 0.6 RKS+FVKS35B unit FVKS35BVMB RKS35BVMB 50-230 5 5 82 5.05 9 0.35 28 0.6 3D040877 3D040399 3D040400 MCA MFA RHz RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency(hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps : Rated motor output (W) NOTES. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. Split - Sky Air Outdoor Units 5

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 2 Specifications 2 ELECTRICAL DATA RKS+FVKS50B unit FVKS50BVMB RKS50BVMB9 50-230 8 20 76 7.04 53 0.8 4+4 0.3 RKS+FLKS25B unit FLKS25BVMB RKS25BVMB 50-230 5 5 48 3.7 9 0.35 34 0.34 RKS+FLKS35B unit FLKS35BVMB RKS35BVMB 50-230 5 5 8 5.03 9 0.35 34 0.38 RKS+FLKS50B unit FLKS50BVMB RKS50BVMB9 50-230 8 20 75 7.00 53 0.8 34 0.54 RKS+FFQ25B RKS+FFQ35B unit FFQ25BVB RKS25BVMB 50-230 5 5 54 3.55 9 0.35 55 0.6 3D040876 3D040395 3D040396 3D040876 FFQ35BVB RKS35BVMB 50-230 5 5 8 5.08 9 0.35 55 0.6 RKS+FFQ50B RKS+FFQ60B unit FFQ50BVB RKS50BVMB9 50-230 8 20 72 7.43 53 0.8 55 0.7 3D040596 FFQ60BVB RKS60BVMB9 50-230 8 20 85 8.45 53 0.24 55 0.7 3D04020 MCA MFA RHz RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency(hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps : Rated motor output (W) NOTES. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 6 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 2 Specifications ELECTRICAL DATA 2 RKS+FCQ35B RKS+FCQ50B RKS+FCQ60B unit FCQ35B7V RKS35BVMB 50-230 5 6 75 4.70 9 0.35 45 0.6 FCQ50B7V RKS50BVMB9 50-230 FCQ60B7V RKS60BVMB9 50-230 8 20 78 7.38 53 0.8 45 0.6 8 20 89 8.72 53 0.24 45 0.6 3TW2508-2 RKS+FHQ35B unit FHQ35BUVB RKS35BVMB 50-230 5 5 78 4.9 9 0.35 62 0.6 RKS+FHQ50B RKS+FHQ60B unit FHQ50BUVB RKS50BVMB9 50-230 8 20 79 7.5 53 0.8 62 0.6 3D040596 FHQ60BUVB RKS60BVMB9 50-230 8 20 90 8.84 53 0.24 62 0.6 3D040597 RKS+FBQ35B RKS+FBQ50B RKS+FBQ60B unit FBQ35B7V RKS35BVMB 50-230 5 6 70 4.42 9 0.35 65 0.5 FBQ50B7V RKS50BVMB9 50-230 FBQ60B7V RKS60BVMB9 50-230 8 20 75 7.00 53 0.8 85 0.7 8 20 9 8.96 53 0.24 25 0.9 3TW2508-2 MCA MFA RHz RLA OFM IFM FLA W SYMBOLS : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency(hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps : Rated motor output (W) NOTES. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. Split - Sky Air Outdoor Units 7

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables 3 RKS+FTKS20C AFR 7.5 BF 0.2 4.0 20 2.05.6 0.38.96.56 0.42.86.52 0.46.83.50 0.47.77.47 0.49.68.43 0.53 6.0 22 2.4.58 0.39 2.05.54 0.42.95.49 0.46.92.48 0.47.86.45 0.50.77.4 0.53 8.0 25 2.23.67 0.39 2.4.63 0.42 2.05.59 0.46 2.0.57 0.48.95.55 0.50.86.5 0.54 9.0 27 2.28.77 0.39 2.9.73 0.43 2.09.69 0.46 2.06.68 0.48 2.00.66 0.50.9.62 0.54 22.0 30 2.42.7 0.39 2.32.68 0.43 2.23.64 0.47 2.9.63 0.48 2.4.6 0.50 2.05.58 0.54 24.0 32 2.5.67 0.39 2.42.64 0.43 2.32.6 0.47 2.29.60 0.48 2.23.58 0.5 2.4.55 0.54 3D044 RKS+FTKS25C AFR 7.5 BF 0.2 4.0 20 2.44.80 0.50 2.44.80 0.58 2.33.74 0.64 2.28.72 0.66 2.2.69 0.69 2.0.63 0.74 6.0 22 2.68.83 0.54 2.56.77 0.59 2.44.72 0.64 2.40.70 0.66 2.33.66 0.69 2.2.6 0.74 8.0 25 2.79.9 0.54 2.68.86 0.59 2.56.8 0.64 2.5.79 0.66 2.44.76 0.69 2.33.7 0.74 9.0 27 2.85 2.0 0.54 2.73.96 0.59 2.62.9 0.64 2.57.89 0.66 2.50.86 0.70 2.38.8 0.75 22.0 30 3.02.94 0.55 2.9.89 0.60 2.79.85 0.65 2.74.83 0.67 2.67.80 0.70 2.56.76 0.75 24.0 32 3.4.88 0.55 3.02.84 0.60 2.90.80 0.65 2.86.79 0.67 2.79.76 0.70 2.67.72 0.75 3D0442 RKS+FTKS35C AFR 7.5 BF 0.7 4.0 20 2.54.88 0.55 2.54.88 0.63 2.54.88 0.72 2.54.88 0.76 2.54.88 0.83 2.54.88 0.96 6.0 22 3.23 2.2 0.70 3.23 2.2 0.8 3.23 2.2 0.94 3.23 2.2 0.99 3.7 2.09.05 3.0 2.0.3 8.0 25 3.80 2.4 0.82 3.64 2.33 0.90 3.48 2.26 0.98 3.42 2.23.0 3.32 2.8.06 3.6 2..4 9.0 27 3.87 2.5 0.82 3.72 2.43 0.90 3.56 2.36 0.98 3.49 2.33.0 3.40 2.29.06 3.42 2.2.4 22.0 30 4. 2.4 0.83 3.95 2.34 0.9 3.79 2.27 0.99 3.73 2.25.02 3.63 2.2.07 3.48 2.5.5 24.0 32 4.27 2.33 0.84 4. 2.27 0.9 3.95 2.2 0.99 3.89 2.9.02 3.79 2.5.07 3.63 2.09.5 3D0443 RKS+FTKS50B AFR.4 BF 0.22 4.0 20 5.06 3.28.3 4.9 3.2.4 4.76 3.4.50 4.70 3..54 4.6 3.07.60 4.46 3.00.69 6.0 22 5.22 3.3.34 5.07 3.24.43 4.92 3.7.53 4.86 3.4.56 4.77 3.0.62 4.62 3.03.72 8.0 25 5.37 3.34.36 5.22 3.27.46 5.07 3.20.55 5.0 3.8.59 4.92 3.3.65 4.77 3.06.74 9.0 27 5.45 3.36.38 5.30 3.29.47 5.5 3.22.57 5.09 3.9.60 5.00 3.5.66 4.85 3.08.76 22.0 30 5.68 3.4.4 5.53 3.34.5 5.38 3.27.60 5.32 3.24.64 5.23 3.20.70 5.08 3.3.79 24.0 32 5.84 3.45.44 5.69 3.38.54 5.54 3.3.63 5.48 3.28.67 5.39 3.24.73 5.24 3.7.82 3D040892 SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 8 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables RKS+FTKS60B AFR 6.2 BF 0.29 4.0 20 6.06 3.97.77 5.9 3.90.87 5.76 3.83.96 5.70 3.80 2.00 5.6 3.76 2.06 5.46 3.69 2.5 6.0 22 6.22 4.00.80 6.07 3.93.89 5.92 3.86.99 5.86 3.83 2.02 5.77 3.79 2.08 5.62 3.72 2.8 8.0 25 6.37 4.03.82 6.22 3.96.92 6.07 3.89 2.0 6.0 3.87 2.05 5.92 3.82 2. 5.77 3.75 2.20 9.0 27 6.45 4.05.84 6.30 3.98.93 6.5 3.9 2.03 6.09 3.88 2.06 6.00 3.84 2.2 5.85 3.77 2.22 22.0 30 6.68 4.0.87 6.53 4.03.97 6.38 3.96 2.06 6.32 3.93 2.0 6.23 3.89 2.6 6.08 3.82 2.25 24.0 32 6.84 4.4.90 6.69 4.07 2.00 6.54 4.00 2.09 6.48 3.97 2.3 6.39 3.93 2.9 6.24 3.86 2.28 3D04089 RKS+FTKS7B AFR 6.7 BF 0.27 4.0 20 7.6 4.60 2.8 7.0 4.53 2.28 6.86 4.46 2.37 6.80 4.43 2.4 6.7 4.39 2.47 6.56 4.32 2.56 6.0 22 7.32 4.63 2.2 7.7 4.56 2.30 7.02 4.49 2.40 6.96 4.46 2.43 6.87 4.42 2.49 6.72 4.35 2.59 8.0 25 7.47 4.67 2.23 7.32 4.60 2.33 7.7 4.53 2.42 7. 4.50 2.46 7.02 4.46 2.52 6.87 4.39 2.6 9.0 27 7.55 4.68 2.25 7.40 4.6 2.34 7.25 4.54 2.44 7.9 4.52 2.47 7.0 4.47 2.53 6.95 4.40 2.63 22.0 30 7.78 4.73 2.28 7.63 4.66 2.38 7.48 4.59 2.47 7.42 4.57 2.5 7.33 4.52 2.57 7.8 4.45 2.66 24.0 32 7.94 4.77 2.3 7.79 4.70 2.4 7.64 4.63 2.50 7.58 4.60 2.54 7.49 4.56 2.60 7.34 4.49 2.69 3D040896 RKS+FVKS25B AFR 8. BF 0.29 4.0 20 2.33.58 0.52 2.25.52 0.58 2.7.47 0.65 2.4.45 0.66 2.08.4 0.67 2.00.35 0.72 6.0 22 2.5.70 0.53 2.43.65 0.59 2.35.59 0.66 2.3.56 0.67 2.25.52 0.68 2.6.46 0.74 8.0 25 2.70.83 0.54 2.6.77 0.6 2.52.7 0.67 2.48.68 0.68 2.42.64 0.69 2.32.57 0.75 9.0 27 2.80.89 0.55 2.70.83 0.6 2.6.77 0.67 2.57.74 0.68 2.50.60 0.70 2.40.62 0.76 22.0 30 3.09 2.09 0.56 2.99 2.02 0.63 2.88.95 0.69 2.84.92 0.70 2.76.87 0.72 2.65.79 0.78 24.0 32 3.28 2.22 0.57 3.8 2.5 0.64 3.07 2.08 0.7 3.02 2.04 0.72 2.94.99 0.73 2.8.9 0.79 3D040390 RKS+FVKS35B AFR 8.3 BF 0.3 4.0 20 3.26 2.2 0.87 3.5 2.05 0.97 3.04.98.07 2.99.95.09 2.92.90. 2.79.82.20 6.0 22 3.52 2.29 0.88 3.40 2.2 0.99 3.29 2.4.09 3.23 2.0.0 3.5 2.05.3 3.02.96.22 8.0 25 3.78 2.46 0.90 3.66 2.38.00 3.53 2.30. 3.47 2.26.2 3.38 2.20.5 3.24 2..24 9.0 27 3.9 2.54 0.9 3.78 2.46.0 3.65 2.38.2 3.59 2.34.3 3.50 2.28.6 3.35 2.8.26 22.0 30 4.32 2.8 0.93 4.8 2.72.04 4.04 2.62.5 3.97 2.58.7 3.87 2.5.9 3.7 2.4.29 24.0 32 4.60 2.99 0.95 4.45 2.89.06 4.29 2.79.7 4.22 2.74.9 4. 2.67.22 3.94 2.56.32 3D04039 SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 3 Split - Sky Air Outdoor Units 9

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables 3 RKS+FVKS50B AFR 0.8 BF 0.23 4.0 20 4.86 3.5.35 4.7 3.08.45 4.56 3.0.54 4.50 2.98.58 4.4 2.94.64 4.26 2.87.73 6.0 22 5.02 3.8.38 4.87 3..47 4.72 3.04.57 4.66 3.02.60 4.57 2.97.66 4.42 2.90.76 8.0 25 5.7 3.22.40 5.02 3.5.50 4.87 3.08.59 4.8 3.05.63 4.72 3.0.69 4.57 2.94.78 9.0 27 5.25 3.23.42 5.0 3.6.5 4.95 3.09.6 4.89 3.07.64 4.80 3.02.70 4.65 2.95.80 22.0 30 5.48 3.29.45 5.33 3.22.55 5.8 3.5.64 5.2 3.2.68 5.03 3.08.74 4.88 3.0.83 24.0 32 5.64 3.32.48 5.49 3.25.58 5.34 3.8.67 5.28 3.5.7 5.9 3..77 5.04 3.04.86 3D040894 RKS+FLKS25B AFR 7.6 BF 0.32 4.0 20 2.33.52 0.54 2.25.47 0.60 2.7.42 0.66 2.4.40 0.67 2.08.36 0.68 2.00.30 0.74 6.0 22 2.5.64 0.54 2.43.59 0.6 2.35.53 0.67 2.3.5 0.68 2.25.47 0.70 2.6.4 0.75 8.0 25 2.70.76 0.55 2.6.7 0.62 2.52.65 0.68 2.48.62 0.69 2.42.58 0.7 2.32.5 0.77 9.0 27 2.80.82 0.56 2.70.76 0.62 2.6.70 0.69 2.57.67 0.70 2.50.83 0.72 2.40.56 0.77 22.0 30 3.09 2.02 0.58 2.99.95 0.64 2.88.88 0.7 2.84.85 0.72 2.76.80 0.74 2.65.73 0.80 24.0 32 3.28 2.4 0.59 3.8 2.07 0.65 3.07 2.00 0.72 3.02.97 0.73 2.94.92 0.75 2.8.84 0.8 3D040382 RKS+FLKS35B AFR 8.6 BF 0.35 4.0 20 3.26 2.02 0.9 3.5.95.02 3.04.89.2 2.99.86.4 2.92.8.7 2.79.73.26 6.0 22 3.52 2.8 0.93 3.40 2..04 3.29 2.04.4 3.23 2.00.6 3.5.95.9 3.02.87.29 8.0 25 3.78 2.35 0.95 3.66 2.27.06 3.53 2.9.6 3.47 2.5.8 3.38 2.0.2 3.24 2.0.3 9.0 27 3.9 2.43 0.95 3.78 2.35.06 3.65 2.27.7 3.59 2.23.9 3.50 2.7.22 3.35 2.08.32 22.0 30 4.32 2.68 0.98 4.8 2.59.0 4.04 2.50.2 3.97 2.46.23 3.87 2.40.26 3.7 2.30.36 24.0 32 4.60 2.85.00 4.45 2.76.2 4.29 2.66.23 4.22 2.62.25 4. 2.55.28 3.94 2.44.38 3D040383 RKS+FLKS50B AFR.4 BF 0.8 4.0 20 4.96 3.26.37 4.8 3.9.47 4.66 3.2.56 4.60 3.09.60 4.5 3.05.66 4.36 2.98.75 6.0 22 5.2 3.30.40 4.97 3.23.49 4.82 3.6.59 4.76 3.3.62 4.67 3.09.68 4.52 3.02.78 8.0 25 5.27 3.33.42 5.2 3.26.52 4.97 3.9.6 4.9 3.6.65 4.82 3.2.7 4.67 3.05.80 9.0 27 5.35 3.35.44 5.20 3.28.53 5.05 3.2.63 4.99 3.8.66 4.90 3.4.72 4.75 3.07.82 22.0 30 5.58 3.40.47 5.43 3.33.57 5.28 3.26.66 5.22 3.23.70 5.3 3.9.76 4.98 3.2.85 24.0 32 5.74 3.43.50 5.59 3.36.60 5.44 3.29.69 5.38 3.26.73 5.29 3.22.79 5.4 3.5.88 3D040893 SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 0 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables RKS+FFQ25B AFR 9.0 BF 0.24 4.0 20 2.33.82 0.62 2.25.76 0.69 2.7.70 0.76 2.4.67 0.78 2.08.62 0.79 2.00.56 0.86 6.0 22 2.5.96 0.63 2.43.90 0.7 2.35.83 0.78 2.3.80 0.79 2.25.75 0.8 2.6.68 0.87 8.0 25 2.70 2. 0.64 2.6 2.04 0.72 2.52.97 0.79 2.48.93 0.80 2.42.88 0.82 2.32.8 0.89 9.0 27 2.80 2.8 0.65 2.70 2. 0.72 2.6 2.04 0.80 2.57 2.00 0.8 2.50.95 0.83 2.40.87 0.90 22.0 30 3.09 2.4 0.67 2.99 2.33 0.75 2.88 2.25 0.82 2.84 2.2 0.84 2.76 2.5 0.85 2.65 2.06 0.92 24.0 32 3.28 2.56 0.68 3.8 2.48 0.76 3.07 2.39 0.84 3.02 2.35 0.85 2.94 2.29 0.87 2.8 2.20 0.94 3D040764 RKS+FFQ35B AFR 0.0 BF 0.25 4.0 20 3.7 2.25 0.97 3.06 2.8.09 2.96 2.0.20 2.9 2.07.22 2.83 2.02.24 2.7.93.35 6.0 22 3.42 2.43 0.99 3.3 2.35.0 3.9 2.27.22 3.4 2.24.24 3.06 2.8.27 2.93 2.09.37 8.0 25 3.67 2.62.0 3.55 2.53.2 3.43 2.44.24 3.37 2.40.26 3.29 2.34.29 3.5 2.24.39 9.0 27 3.80 2.7.02 3.68 2.62.3 3.55 2.53.25 3.49 2.48.27 3.40 2.42.30 3.26 2.32.4 22.0 30 4.20 2.99.05 4.06 2.89.7 3.92 2.79.29 3.86 2.74.3 3.76 2.67.34 3.60 2.56.45 24.0 32 4.47 3.8.07 4.32 3.07.9 4.7 2.97.3 4.0 2.92.33 4.00 2.84.36 3.83 2.72.48 3D040766 RKS+FFQ50B AFR 2.0 BF 0.6 4.0 20 4.76 3.5.45 4.6 3.44.55 4.46 3.37.64 4.40 3.34.68 4.3 3.30.74 4.6 3.23.83 6.0 22 4.92 3.54.48 4.77 3.47.57 4.62 3.40.67 4.56 3.38.70 4.47 3.33.76 4.32 3.26.86 8.0 25 5.07 3.58.50 4.92 3.5.60 4.77 3.44.69 4.7 3.4.73 4.62 3.37.79 4.47 3.30.88 9.0 27 5.5 3.59.52 5.00 3.52.6 4.85 3.45.7 4.79 3.43.74 4.70 3.38.80 4.55 3.3.90 22.0 30 5.38 3.65.55 5.23 3.58.65 5.08 3.5.74 5.02 3.48.78 4.93 3.44.84 4.78 3.37.93 24.0 32 5.54 3.68.58 5.39 3.6.68 5.24 3.54.77 5.8 3.5.8 5.09 3.47.87 4.94 3.40.96 3D04022 RKS+FFQ60B AFR 5.0 BF 0. 4.0 20 5.86 4.30.72 5.7 4.23.82 5.56 4.6.9 5.50 4.3.95 5.4 4.09 2.0 5.26 4.02 2.0 6.0 22 6.02 4.34.75 5.87 4.27.84 5.72 4.20.94 5.66 4.7.97 5.57 4.3 2.03 5.42 4.06 2.3 8.0 25 6.7 4.37.77 6.02 4.30.87 5.87 4.23.96 5.8 4.20 2.00 5.72 4.6 2.06 5.57 4.09 2.5 9.0 27 6.25 4.39.79 6.0 4.32.88 5.95 4.25.98 5.89 4.22 2.0 5.80 4.8 2.07 5.65 4. 2.7 22.0 30 6.48 4.44.82 6.33 4.37.92 6.8 4.30 2.0 6.2 4.27 2.05 6.03 4.23 2. 5.88 4.6 2.20 24.0 32 6.64 4.47.85 6.49 4.40.95 6.34 4.33 2.04 6.28 4.30 2.08 6.9 4.26 2.4 6.04 4.9 2.23 3D04027 SYMBOLS NOTES AFR: Air flow rate (m 3 /min). Ratings shown are net capacities which include a deduction for indoor fan BF: Bypass factor motor heat EWB: Entering wet bulb temp. ( CWB) 2. Shows nominal cooling capacities and power input EDB: Entering dry bulb temp. ( CDB) 3. TC, PI and SHC must be calculated by interpolation using the figures in the TC: Total capacity (kw) above tables. (Figures out of the tables should not be used for calculation.) SHC: Sensible heating capacity (kw) 4. SHC is based on each EWB and EDB PI: Power input (kw) SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. 3 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables 3 RKS+FCQ35-60B Outdoor 35 50 60 4.0 20.0 3.2 2.7 0.9 3. 2.6.0 3.0 2.5.2 2.9 2.4.3 2.8 2.4.6 2.7 2.3.25 6.0 22.0 3.4 2.9 0.92 3.3 2.8.03 3.2 2.7.4 3. 2.6.5 3. 2.6.8 2.9 2.5.28 8.0 25.0 3.7 3. 0.94 3.6 3.0.05 3.4 2.9.6 3.4 2.8.7 3.3 2.8.20 3.2 2.6.30 9.0 27.0 3.8 3.2 0.95 3.7 3..06 3.6 3.0.7 3.5 2.9.8 3.4 2.9.2 3.3 2.7.3 22.0 30.0 4.2 3.5 0.97 4. 3.4.09 3.9 3.3.20 3.9 3.2.22 3.8 3.2.25 3.6 3.0.35 24.0 32.0 4.5 3.8 0.99 4.3 3.6. 4.2 3.5.22 4. 3.4.24 4.0 3.4.27 3.8 3.2.37 4.0 20.0 5. 3.7.57 4.9 3.6.67 4.8 3.5.76 4.7 3.5.80 4.6 3.5.86 4.5 3.4.95 6.0 22.0 5.2 3.7.60 5. 3.6.69 4.9 3.6.79 4.9 3.5.83 4.8 3.5.88 4.6 3.4.98 8.0 25.0 5.4 3.7.62 5.2 3.7.72 5. 3.6.8 5.0 3.6.85 4.9 3.5.9 4.8 3.5 2.00 9.0 27.0 5.5 3.8.64 5.3 3.7.73 5.2 3.6.83 5. 3.6.87 5.0 3.6.92 4.9 3.5 2.02 22.0 30.0 5.7 3.8.68 5.5 3.7.77 5.4 3.7.87 5.3 3.6.90 5.2 3.6.96 5. 3.5 2.06 24.0 32.0 5.8 3.8.70 5.7 3.8.80 5.5 3.7.89 5.5 3.7.93 5.4 3.6.99 5.2 3.6 2.08 4.0 20.0 5.8 4.5.84 5.6 4.4.94 5.5 4.3 2.03 5.4 4.3 2.07 5.3 4.3 2.3 5.2 4.2 2.22 6.0 22.0 5.9 4.5.87 5.8 4.4.96 5.6 4.4 2.06 5.6 4.4 2.0 5.5 4.3 2.5 5.3 4.2 2.25 8.0 25.0 6. 4.6.89 5.9 4.5.99 5.8 4.4 2.08 5.7 4.4 2.2 5.6 4.3 2.8 5.5 4.3 2.27 9.0 27.0 6.2 4.6.9 6.0 4.5 2.00 5.9 4.4 2.0 5.8 4.4 2.3 5.7 4.4 2.9 5.6 4.3 2.29 22.0 30.0 6.4 4.6.95 6.2 4.6 2.04 6. 4.5 2.4 6.0 4.5 2.7 5.9 4.4 2.23 5.8 4.3 2.33 24.0 32.0 6.5 4.7.97 6.4 4.6 2.07 6.2 4.5 2.6 6.2 4.5 2.20 6. 4.4 2.26 5.9 4.4 2.35 3TW25082- SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) NOTES. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal cooling capacities and power input 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m 3 /min) x (-BF) x (DB-EDB)/860 AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate and BF are tabulated below. Model 35 50 60 FCQ AFR 4 BF 0.6 AFR 5 BF 0.6 AFR 8 BF 0.0 2 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables RKS+FHQ35B AFR 3 BF 0.20 4.0 20 3.7 2.47 0.9 3.06 2.39.0 2.96 2.30.2 2.9 2.27.3 2.83 2.2.6 2.7 2..25 6.0 22 3.42 2.67 0.92 3.3 2.58.03 3.9 2.49.4 3.4 2.45.5 3.06 2.38.8 2.93 2.28.28 8.0 25 3.67 2.86 0.94 3.55 2.77.05 3.43 2.67.6 3.37 2.63.7 3.29 2.56.20 3.5 2.45.30 9.0 27 3.80 2.96 0.95 3.68 2.86.06 3.55 2.77.7 3.49 2.72.8 3.40 2.65.2 3.26 2.54.3 22.0 30 4.20 3.27 0.97 4.06 3.7.09 3.92 3.06.20 3.86 3.0.22 3.76 2.93.25 3.60 2.8.35 24.0 32 4.47 3.48 0.99 4.32 3.37. 4.7 3.25.22 4.0 3.20.24 4.00 3..27 3.83 2.98.37 3 3D040599 RKS+FHQ50B AFR 3 BF 0. 4.0 20 5.06 3.63.48 4.9 3.56.58 4.76 3.49.67 4.70 3.46.7 4.6 3.42.77 4.46 3.35.86 6.0 22 5.22 3.66.5 5.07 3.59.60 4.92 3.52.70 4.86 3.49.73 4.77 3.45.79 4.62 3.38.89 8.0 25 5.37 3.69.53 5.22 3.62.63 5.07 3.55.72 5.0 3.53.76 4.92 3.48.82 4.77 3.4.9 9.0 27 5.45 3.7.55 5.30 3.64.64 5.5 3.57.74 5.09 3.54.77 5.00 3.50.83 4.85 3.43.93 22.0 30 5.68 3.76.58 5.53 3.69.68 5.38 3.62.77 5.32 3.59.8 5.23 3.55.87 5.08 3.48.96 24.0 32 5.84 3.80.6 5.69 3.73.7 5.54 3.66.80 5.48 3.63.84 5.39 3.59.90 5.24 3.52.99 3D04060 RKS+FHQ60B AFR 7 BF 0.2 4.0 20 5.76 4.7.80 5.6 4.0.90 5.46 4.03.99 5.40 4.00 2.03 5.3 3.96 2.09 5.6 3.89 2.8 6.0 22 5.92 4.2.83 5.77 4.4.92 5.62 4.07 2.02 5.56 4.04 2.05 5.47 4.00 2. 5.32 3.93 2.2 8.0 25 6.07 4.24.85 5.92 4.7.95 5.77 4.0 2.04 5.7 4.07 2.08 5.62 4.03 2.4 5.47 3.96 2.23 9.0 27 6.5 4.26.87 6.00 4.9.96 5.85 4.2 2.06 5.79 4.09 2.09 5.70 4.05 2.5 5.55 3.98 2.25 22.0 30 6.38 4.3.90 6.23 4.24 2.00 6.08 4.7 2.09 6.02 4.4 2.3 5.93 4.0 2.9 5.78 4.03 2.28 24.0 32 6.54 4.34.93 6.39 4.27 2.03 6.24 4.20 2.2 6.8 4.7 2.6 6.09 4.3 2.22 5.94 4.06 2.3 3D040604 SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) NOTES. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal cooling capacities and power input 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.02 x AFR (m 3 /min) x (-BF) x (DB-EDB) AddSHC*toSHC. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are taburated above. Split - Sky Air Outdoor Units 3

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 3 Capacity tables 3 RKS+FBQ35-60B Outdoor 35 50 60 4.0 20.0 3.2 2.4 0.9 3. 2.3.0 3.0 2.2.2 2.9 2.2.3 2.8 2..6 2.7 2.0.25 6.0 22.0 3.4 2.6 0.92 3.3 2.5.03 3.2 2.4.4 3. 2.4.5 3. 2.3.8 2.9 2.2.28 8.0 25.0 3.7 2.8 0.94 3.6 2.7.05 3.4 2.6.6 3.4 2.5.7 3.3 2.5.20 3.2 2.4.30 9.0 27.0 3.8 2.9 0.95 3.7 2.8.06 3.6 2.7.7 3.5 2.6.8 3.4 2.6.2 3.3 2.4.3 22.0 30.0 4.2 3.2 0.97 4. 3.0.09 3.9 2.9.20 3.9 2.9.22 3.8 2.8.25 3.6 2.7.35 24.0 32.0 4.5 3.3 0.99 4.3 3.2. 4.2 3..22 4. 3..24 4.0 3.0.27 3.8 2.9.37 4.0 20.0 5. 3.6.57 4.9 3.5.67 4.8 3.4.76 4.7 3.4.80 4.6 3.4.86 4.5 3.3.95 6.0 22.0 5.2 3.6.60 5. 3.5.69 4.9 3.5.79 4.9 3.4.83 4.8 3.4.88 4.6 3.3.98 8.0 25.0 5.4 3.6.62 5.2 3.6.72 5. 3.5.8 5.0 3.5.85 4.9 3.4.9 4.8 3.4 2.00 9.0 27.0 5.5 3.7.64 5.3 3.6.73 5.2 3.5.83 5. 3.5.87 5.0 3.5.92 4.9 3.4 2.02 22.0 30.0 5.7 3.7.68 5.5 3.6.77 5.4 3.6.87 5.3 3.5.90 5.2 3.5.96 5. 3.4 2.06 24.0 32.0 5.8 3.7.70 5.7 3.7.80 5.5 3.6.89 5.5 3.6.93 5.4 3.5.99 5.2 3.5 2.08 4.0 20.0 5.8 4.6.84 5.6 4.6.94 5.5 4.5 2.03 5.4 4.5 2.07 5.3 4.4 2.3 5.2 4.3 2.22 6.0 22.0 5.9 4.7.87 5.8 4.6.96 5.6 4.5 2.06 5.6 4.5 2.0 5.5 4.5 2.5 5.3 4.4 2.25 8.0 25.0 6. 4.7.89 5.9 4.6.99 5.8 4.6 2.08 5.7 4.5 2.2 5.6 4.5 2.8 5.5 4.4 2.27 9.0 27.0 6.2 4.7.9 6.0 4.6 2.00 5.9 4.6 2.0 5.8 4.5 2.3 5.7 4.5 2.9 5.6 4.4 2.29 22.0 30.0 6.4 4.8.95 6.2 4.7 2.04 6. 4.6 2.4 6.0 4;6 2.7 5.9 4.6 2.23 5.8 4.5 2.33 24.0 32.0 6.5 4.8.97 6.4 4.7 2.07 6.2 4.7 2.6 6.2 4.6 2.20 6. 4.6 2.26 5.9 4.5 2.35 3TW252- SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) NOTES. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal cooling capacities and power input 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m 3 /min) x (-BF) x (DB-EDB)/860 AddSHC*toSHC. 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate and BF are tabulated below. Model 35 50 60 FCQ AFR.5 BF 0.5 AFR 4 BF 0.5 AFR 9 BF 0. 4 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 4 Dimensional drawings RKS20,25,35C unit (mm) 4 Drain outlet (I.D. J 5.9 hose for connection) 4 x holes for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than 200 Handle Brand name label Terminal strip with earth terminal Outdoor air thermistor Name plate Wiring inlet Liquid stop valve (J A CuT) Service port In case of removing stop valve cover Gas stop valve (J B CuT) 3D04800 RKS50,60,7B unit (mm) Drain outlet (I.D. J 5.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than 200 In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M0) Brand name label Name plate Wiring inlet Terminal strip with earth terminal Outdoor air thermistor Model A B RKS50, RKS60 6.4 2.7 RKS7 6.4 5.9 Indication label (refrigerant) Liquid stop valve (J A CuT) Service port Gas stop valve (J B CuT) 3D034257B Split - Sky Air Outdoor Units 5

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 5 Operation range 5 RKS20,25,35C RKS50,60,7B Outdoor temp. ( CDB) Pull-down period Notes: The graph is based on the following conditions:. Equivalent piping length 7.5 m 2. Level difference 0 m 3. Air flow rate high temp. ( CWB) 4D029297C * Possibility to extend the operation range down to -5 C by turning on the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20 C or lower and will recover when temperature rises again. 6 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 6 Piping diagrams RKS20,25C 6 Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Muffler with filter Propeller fan Muffler Four way valve normally: OFF Liquid stop valve Field piping Discharge pipe thermistor Compressor Field piping Accumulator Muffler Gas stop valve Refrigerant flow Cooling 3D043690 RKS35C Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Muffler with filter Propeller fan Four way valve normally: OFF Field piping Liquid stop valve Muffler Discharge pipe thermistor Compressor Accumulator Muffler Gas stop valve Field piping Refrigerant flow Cooling 3D04369 Split - Sky Air Outdoor Units 7

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 6 Piping diagrams 6 RKS50B Heat exchanger Outdoor temperature thermistor Capillary tube Heat exchanger thermistor Capillary tube 2 Muffler with filter Refrigerant flow Cooling Capillary tube 3 Propeller fan Filter Motor operated valve Muffler with filter Field piping Discharge pipe thermistor Liquid stop valve Field piping Compressor Accumulator Gas stop valve with service port 3D037835A RKS60,7B Heat exchanger Outdoor temperature thermistor Capillary tube Capillary tube 2 Capillary tube 3 Muffler with filter Refrigerant flow Cooling Heat exchanger thermistor Capillary tube 4 Propeller fan Filter Motor operated valve Muffler with filter Field piping Discharge pipe thermistor Liquid stop valve Field piping Compressor Accumulator Gas stop valve with service port 3D037836A 8 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 7 Wiring diagrams RKS20,25,35C 7 g Field wiring Outdoor NOTE. Refer to the name plate for the power requirements. R : Protective earth C74, C75 C94, C95, C00 : Capacitor DB, DB2 : Diode bridge FU, F2U, F3U : Fuse IC : Solid state relay IPM : Intelligent power module L : Live L : Coil LR : Reactor MC : Compressor motor MF : Fan motor PCB : Printed circuit board MRCW, MRM0, MRM20 : Magnetic relay In case of cooling only type N : Neutral PCB, PCB2 : Printed circuit board QL : Overload protector RT, R2T, R3T, : Thermistor S0, S, S20, S30, S40, S70 S80, S90, S9 HC3, HC4, HL3, HN3 : Connector In case of heat pump type (outdoor) (discharge) (Condenser) SA : Surge arrester ZC, Z2C : Ferrite core V, V2, V3 : Varistor YE : Electronic expansion valve coil YR : Reversing solenoide valve coil XM : Terminal strip 3D042576B RKS50,60,7B To indoor unit Power supply 50Hz 220-240V 60Hz 220-230V g Field wiring R : Protective earth ZC, Z2C : Ferrite core XM : Terminal strip Y2E : Electronic expansion valve coil V2 V5 : Varistor FU, F2U, FU20 : Fuse HE, HE2, HAC, E, AC, AC2 H, H2, HL L, L2, XA : Connector MRM0, MRM20, MRC/W : Magnetic relay RT R3T S2 S02 LEDA PCB, PCB2 L N SW S4W SA : Thermistor : Connector : Pilot lamp : Printed circuit board : Live : Neutral : Forced operation on/off switch (SW) : Local setting : Surge arrester Outdoor DB MC MF LR QL CT MID SPM (outdoor) (discharge) (Condenser) : Diode bridge : Compressor motor : Fan motor : Reactor : Overload protector : Current transformer : Molded interconnect device : System power module 3D037866D Split - Sky Air Outdoor Units 9

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 8 Sound level 8 8-8- Sound level data Cooling only Model 230V, 50Hz Cooling Sound pressure level Measuring location Sound power level (cooling) H L RKS20C 46 43 6 RKS25C 46 43 6 RKS35C 47 44 62 RKS50B 47 * 63 RKS60B 49 * 64 RKS7B 52 * 66 * This information was not available at the time of publication. 8-2 Sound pressure spectrum RKS20-25C (Cooling) RKS35C (Cooling) Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D04405 4D04406 Octave band center frequency (Hz) Octave band center frequency (Hz) Legend NOTES Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Reference acoustic pressure 0dB = 20µPa 50/60Hz, 220-240/220-230V 20 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 8 Sound level 8-2 Sound pressure spectrum Cooling only RKS50B RKS60B 8 8-2 Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D027648B Octave band center frequency (Hz) 4D040949 Octave band center frequency (Hz) RKS7B Octave band sound pressure level Legend 50/60Hz, 220-240/220-230V approximate threshold hearing for continuous noise 3D027650B Octave band center frequency (Hz) NOTES Operation sound is measured in an anechoic chamber. 2 Operation sound level differs with operation and ambient conditions. 3 Reference acoustic pressure 0dB = 20µPa Split - Sky Air Outdoor Units 2

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 9 Accessories 9 9-9- Standard accessories RKS-C/B Accessories supplied with the outdoor unit: Installation manual 9-2 Optional accessories RKS-C/B RKS20CVMB RKS25CVMB RKS35CVMB RKS50BVMB9 RKS60BVMB9 RKS7BVMB9 Air direction adjustment grille KPW937A4 KPW945A4 22 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 0 Center of gravity RKS20,25,35C 0 4D04407 RKS50,60B The position of foundation bolt 4D042259 Split - Sky Air Outdoor Units 23

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB 0 Center of gravity 0 RKS7B The position of foundation bolt 4D042258A 24 Split - Sky Air Outdoor Units

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB Installation RKS20,25,35C installation drawings Model 20 / 25 / 35 class Max. allowable length 20 m Max. allowable height 5m Additional refrigerant required for refrigerant pipe exceeding 20 g/m 0 m in length. Gas pipe O.D. 9.5 mm Liquid pipe O.D. 6.4 mm * Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Wrap the installation pipe with the finishing tape from bottom to top 250 mm from wall Service lid How to remove the service lid. + This service lid is an open/close type. + Slide the lid downward to remove it. How to attach the service lid. + Insert the upper part of the service lid into the outdoor unit to install. + Tighten the screws. In sites with poor drainage, use block bases for outdoor unit. Adjust foot height until the unit is leveled. Otherwise, water leakage or pooling of water may occur. Foot bolt-hole centres 574 05.5 From unit s side 3 Foot bolt-hole centres Where there is a danger of the unit falling, use foot bolts, or wires. Allow space for piping and electrical servicing. unit (mm) Split - Sky Air Outdoor Units 25

Pair Application, Inverter Controlled Unit R-40A RKS20-25-35CVMB RKS50-60-7BVMB Installation RKS50,60,7B installation drawings Model 50 class 60 class 7 class Max. allowable length 30m Max. allowable height 20m Additional refrigerant required for refrigerant pipe exceeding 0 m in length. 20 g/m Gas pipe O.D. 2.7 mm O.D. 9.5 mm Liquid pipe O.D. 6.4 mm * Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Wrap the installation pipe with the finishing tape from bottom to top Service lid 250 mm from wall In sites with poor drainage, use block bases for outdoor unit. Adjust foot height until the unit is leveled. Otherwise, water leakage or pooling of water may occur. 580 mm 20 mm 330 mm Foot bolt-hole centres Allow space for piping and electrical servicing. Foot bolt-hole centres From unit s side Where there is a danger of the unit falling, use foot bolts, or wires. 26 Split - Sky Air Outdoor Units