Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Similar documents
Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

Accurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

Central Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

ICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

A.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Discipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

Caliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra

Cal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra

Certificate of Accreditation

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Discipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

CERTIFICATE OF ACCREDITATION

Certificate of Accreditation

VISCOSITY CALIBRATION STANDARDS

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

TEST AND CALIBRATION SERVICES Ensuring quality and reliability.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES

UGANDA NATIONAL BUREAU OF STANDARDS NATIONAL METROLOGY LABORATORY

Welcome to Garber C O R P O R AT E O V E R V I E W

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

Date and Time of Pre Bid Meeting November 22, 2016 at a.m

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

A Guide to Dry Block Calibration

CERTIFICATE OF ACCREDITATION

Mass Comparators Advanced Radwag solutions for traceability of measurement

TESIGNG OF FUELS: VISCOSITY OF LIQUID FUELS

Transferpette. Testing Instructions (SOP) 1. Introduction. October 2013

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Ref:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

Certificate of Accreditation

Laboratory Equipment. Tel: +44 (0) u Fax: +44 (0) u

ISOCAL - 6 Range Europa Venus Calisto

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Rototherm Certificates of Calibration Traceability and Quality System

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

Selecting Weights and Certificates

VITLAB Dispenser. Standard Operating Procedure (SOP)

SCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC

Certificate of Accreditation

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

Flow Research and Test Center. Creating resource technology for today and tomorrow.

USV Ultra Shear Viscometer

Titrette and Digital Burette

Accreditation No: LAB 026. Attock Refinery Limited, Rawalpindi, Pakistan


ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Multi-Parameter Certified Reference Material

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER

IEC SYSTEM FOR CONFORMITY TESTING AND COMMITTEE OF TESTING LABORATORIES CERTIFICATION OF ELECTRICAL EQUIPMENT

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

Foaming of Lubricating Oils (manual)

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

Hydraulic Deadweight Tester Model CPB5800

ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

Accreditation No: LAB 026. Attock Refinery Limited, Rawalpindi, Pakistan.

Metrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005

Flow Research and Test Center

Procedure for Koehler Digital Constant Temperature Viscosity Bath

Optidew Vision Optical Dew-Point Meter

CHAPTER-3 EXPERIMENTAL SETUP. The experimental set up is made with necessary. instrumentations to evaluate the performance, emission and

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P.

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

Dead-weight tester in compact design Model CPB3800

Discipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on


Laboratory Accreditation Programmes

Single-Input Thermocouple. Thermometers Type J, K, T

U tube viscometer. Kinematic viscosity bath RASAYAN

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Tex-614-J, Testing Epoxy Materials

Transcription:

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 1 of 7 ELECTRO-TECHNICAL CALIBRATION I. MEASURE 1. Time $ 5 sec to 9900 sec 0.12 sec to 5.8 sec Using Digital Time Totalizer (Digital Timer/Analog by Comparison Method & Digital Stop Watch)

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 2 of 7 MECHANICAL CALIBRATION I. WEIGHTS 1. Mass $ (F1 & Coarser) 1 mg 0.02 mg Using Weights of Accuracy 2 mg 0.02 mg Class E1 & F1 and Precision 5 mg 0.02 mg Balances Analytical Balance 10 mg 0.02 mg by Substitution Method of 20 mg 0.03 mg Weighing and ABBA 50 mg 0.03 mg Weighing Cycle as 100 mg 0.03 mg per OIML R -111 2004 200 mg 0.03 mg 500 mg 0.04 mg 1g 0.04 mg 2g 0.05 mg 5g 0.06 mg 10g 0.09 mg 20g 0.15 mg 50g 0.27 mg 100g 0.51 mg 200g 1.0 mg 500g 1.0 mg 1 kg 1.3 mg II. WEIGHING SCALE AND BALANCE 1. Weighing Machine d= 0.001 mg 0 to 200 g 0.005 mg Using Weights of Accuracy d= 0.01 mg 0.05 mg Class E1 based on d= 0.1 mg 0.4 mg d= 1 mg 0 to 1 kg 5.3 mg Using Weights of Accuracy Class E1 & E 2 based on

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 3 of 7 III. d= 10 mg 0 to 5 kg 90 mg Using Weights of Accuracy d= 100 mg 500 mg Class E2, F1 & M1based on d= 1 g 0 to 20 kg 1.1 g Using Weights of Accuracy Class E2, F1 & M1based on d= 10 g 0 to 150 kg 15 kg Using Weights of Accuracy Class F1 & M1based on VOLUME 1. Piston Pipette $ >100 µl to 1000 µl >1000 µl to 5000 µl 0.28 µl 0.28 µl Using Micropipette as per IS 8655-6 & ISO/TR 20461 and Digital Balance upto 200 g readability 0.01 mg and Distilled Water of known Density 2. Glass Pipettes $ (Graduated/ Non Graduated) 0.1 ml to 10 ml >10 ml to 50 ml 0.8 µl 3.8 µl Using Digital Precision Balance and Distilled Water of known density as per ISO 4787 & ISO/TR 20461 3. Glass Burette $ 0.1 ml to 10 ml >10 ml to 50 ml 0.8 µl 3.8 µl Using Digital Precision Balance and Distilled Water of known density as per ISO 4787 & ISO/TR 20461 4. Measuring Cylinder/Volumetric Flask/Conical Flask / Beaker $ 5 ml to 100 ml >100 ml to 500 ml >500 ml to 1000 ml 12.0 µl 60.0 µl 150.0 µl Using Digital Precision Balance and Distilled Water of known density as per ISO 4787 & ISO/TR 20461

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 4 of 7 IV. VISCOSITY 1. Rotational Viscometer $ 10 to 100 cp 100 to 1000 cp 1000 to 15000 cp 1.2 % 1.2 % 1.5 % Using Dynamic/ Absolute viscosity of the standard oil is compared with the digital output of the viscometers as per standards ISO-2555, ISO 1652 15000 to 72000 cp 1.7 % 2. Ford Cup/ Flow cup $ 10 cst to 220 cst 220 cst to 1200 cst 2.5 % 4.2 % Using Standard Viscometer and oil as per IS 3944-1982 and ASTM D1200 V PRESSURE INDICATING DEVICES 1. Pressure (Pneumatic) Analog/Digital Pressure Gauge/ Transducer/ Transmitters # 0.05 bar to 20 bar 0.16 % of reading Using Pneumatic calibrator Budenberg E400 by Comparison Method as per DKD R 6.1 2. Pressure (Hydraulic) Analog/Digital Pressure Gauge/ Transducer/ Transmitters $ 1 bar to 60 bar 60 barto 700 bar 0.1 % of reading 0.16 % of reading Using Dead weight tester Budenberg HX 480 By Comparison Method as per DKD R 6.1

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 5 of 7 3. Negative Pressure Analog/Digital Vacuum Gauge/ Transducer/ Transmitters # (-) 0.85 bar to 0 bar 1.15 % of reading Using Pneumatic calibrator Budenberg E400 by Comparison Method as per ISO 3567 VI. ACCELERATION AND SPEED 1. Speed/Non Contact Centrifuges 100 rpm to 25000 rpm 5.8 rpm to 58 rpm Digital TachometerTACH 4A by comparison as per Sanas TR 45-01

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 6 of 7 THERMAL CALIBRATION I. TEMPERATURE 1. Glass Thermometers, PRT/RTD s Thermocouples With Indicator/Without Indicator, Oven $ (-)80 ⁰ C to 50 ⁰ C 50 ⁰ C to 300 ⁰ C 0.11 ⁰ C 0.12 ⁰ C Using PRT, DTI, Low Temperature Bath &Ice Point by Comparison Method Using PRT, High Precision Bath, DTI by Comparison Method 300 ⁰ C to 600 ⁰ C 0.5 ⁰ C Using PRT, DTI, High Temperature Furnace by Comparison Method 600 ⁰ C to 1200 ⁰ C 1.8 ⁰ C Using S Type Thermocouple, High Temperature Furnace, DTI by Comparison Method 2. Oven, Thermal Chambers, Deep Freezers, Refrigerator,Spatial Mapping (-)80 ⁰ C to 300 ⁰ C 0.5 ⁰ C Using PRT, DTI, T Type with DTI by Comparison Method Furnace (Single Point) 200 ⁰ C to 1200 ⁰ C 1.7 ⁰ C Using S Type Thermocouple, DTI, by Comparison Method Thermocouples 100 ⁰ C to 300 ⁰ C 200 ⁰ C to 800 ⁰ C 800 ⁰ C to 1200 ⁰ C 0.5 ⁰ C 1.2 ⁰ C 2.2 ⁰ C Using R Type Thermocouple, DTI by Comparison Method

Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 7 of 7 II. SPECIFIC HEAT AND HUMIDITY 1. Temperature & 30 % to 95 % Humidity Indicators $ Rh @ 25 ⁰ C 5 ⁰ C to 50 ⁰ C @ 60 % RH 2. Humidity Chambers 30 % to 95 % Rh @ 25 ⁰ C 1.8 % 0.3 ⁰ C Using Temperature & Humidity Indicator with Probe PT 100 with Digital Indicator by Comparison Method 1.8 % RH Using Temperature & Humidity Indicator with Probe by Comparison Method & Single Position * Measurement Capability is expressed as an uncertainty ( ) at a confidence probability of 95% $ Only in Permanent Laboratory Φ Laboratory can also calibrate instruments/devices of coarser resolution / least count within the accredited range using same reference standard/ master equipment under the scope of accreditation. # The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual environmental conditions and master equipment used.