CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

Similar documents
THERMOSTATIC CONTROL HEADS:

CALEFFI. Differential pressure by-pass valve. 519 series 01007/14 NA. Replaces 01007/12 NA

CALEFFI. HydroMixer direct distribution unit for heating systems. 165 series 01237/13 NA. Function

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

R EGI S TERED. Function

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

CALEFFI. zone valves. Z series 01115/14 NA. Replaces 01115/11 NA. Function

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

Safety cap. Measuring probe. Seal. Operating principle. Advantages of balanced circuits. Balanced circuits have the following principal benefits:

Air Actuated Ball Valves 3-Way T-Port Stainless Steel, Full Bore 1/4 to 2 NPT

Air Actuated 3-Way Ball Valves L-Port Brass, Standard Port 1/4 to 3 NPT

THERMOSETTER Recirculation thermal balancing valve

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

599 Series Zone Valve Bodies:

Technical information Thermostatic radiator valves

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

Air Actuated Stainless Ball Valves 2-Piece Stainless Steel, Full Port 1/4 to 2 NPT

SELECTION. Easily Selectable Easily Serviceable. Interchangeability as easy as 1-2-3

966SRL 966SBL Nominal size A B C D Weight Red Lever Blue Lever in mm mm mm mm kg Product Code Product Code

Air Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 NPT

599 Series Zone Valve Bodies:

B1F. B Series Forged Brass Ball Valves 5.1

CALEFFI. QuickSetter Balancing Valve with flow meter. Installation Tip

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

132 Series. QuickSetter Balancing Valve with flow meter NA Function

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents

VG6000. Globe Valves Series for Terminal Units. Product Bulletin

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

548 hydraulic separator

COMPONENTS FOR SOLAR THERMAL SYSTEMS

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

Maximum Working Pressure. Code Description Brass

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

Characterized Port -CP Three-Way Ball Valves

S, M, L, and 31 Series. Straight-pattern flow coefficients (C v ) from to Low- and high-pressure service

CNC DISTRIBUTION. ITEM NO Description Quantity

NAME OF PAGE. Opening paragraph. header. header. header. header PAGE 1

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

Series 870 Sleeve coupling for repairs Sizes Ø 25, Ø 32, Ø 40, Ø 50

MANUAL VALVES AND LOCKSHIELD VALVES FOR RADIATORS

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

SOLUTIONS GUIDE. For total efficiency

Pre-assembled distribution manifolds for radiant panel systems

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

PIPING PACKAGES TABLE OF CONTENTS

T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)

Product Instructions. Mixing Station. Features. Specifications. Materials

Pneumatic Fittings & Tubing

Hydronic Specialties AFLB Series Specifications Automatic Pressure Independent Flow Limiter w/ Ball Valve

SOLAR HEATING SYSTEM

Powers Controls Powertop Two-Way Valves Normally Open

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

3-Way Brass Ball Valves L or T Port Design, 400 PSI WOG 1/4 to 3 NPT

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection

turia 3000 valve WATER SERIES SCOPE SERVICE CONDITIONS TECNICAL SHEET 08/2011 IP06010 PAG. 1/6

AV 23 Balancing valves SETTER Inline

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability

Solar collector racking system CALEFFI NAS100 series ACCREDITED Function Product range NAS100 NAS100 NAS100 NAS100

SELECTION GUIDE. A broad selection of inlet and outlet configurations and choice of sizes. Easily Selectable Easily Serviceable

Components for central heating

Behringer Ball Valve Ordering Code

MALE X FEMALE LARGE-PORT BALL VALVE T-900 M x F and T-900 M x F-T

SELECTION GUIDE. A broad selection of inlet and outlet configurations and choice of sizes. Easily Selectable Easily Serviceable

Instrument Ball Valves

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline EC & EK Series Characterized Control Valves Sizes 1/2 6

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

SPEAKMAN CPT SentinelPro Thermostatic/Pressure Balance Valve Trim FEATURES: AVAILABLE FINISHES: ADD SUFFIX TO MODEL # WARRANTY: SPECIFICATION

Accessories. UP timer. Timer control. Approvals. UP Series

505F Multi-Port Ball Valve

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

Installation Instructions

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

MrPEX 1 ¼ Stainless Steel Manifold Installation Guide

Mikrotherm F. Manual Radiator Valves With presetting

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

VMP43... Two-port and three-port seat valves PN16. Siemens Building Technologies Landis & Staefa Division

SINGLE-PIPE AND TWIN-PIPE VALVES. Technical documentation 0185EN

ATT Series Adjustable PIC Valves 2 Way 1/2-1-1/2 ATT - AutoTouch Terminal

three-way mixing valve

SECTION METERS AND GAUGES FOR HVAC PIPING

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

Self-Acting Temperature Control Valve

Modulating Water Valves and Bulb Wells

Please refer to our catalogue for details of the full product range

DESCRIPTION 9.4 G 3/4"M

Max. Operating Pressure. Group 1

Transcription:

iverter and isolation valves for panel radiators 00, 0, 02, 0 series RIT LI 006/2 N ISO 900 M 2654 ISO 900 No. 000 unction aleffi 0 series valves are installed on panel style radiators. They are connected to the bottom supply and return ports, providing fluid flow to the upper thermostatic valve built into the radiator. The center-to-center dimension is 50 mm, which is the common standard for all brands of panel radiators. Two versions are available: iverter style for one-pipe systems; Isolation style for two-pipe systems. oth have two ball shut-off valves and come as either a through flow pattern for floor connections or angled flow pattern for wall connections. The diverter style offers an adjustable by-pass to send 0% to 50% of flow toward the radiator, factory-set for 5%. In addition, the diverter style contains a unique thermal break device in the return side (right leg) to prevent undesirable flow to the radiator due to thermo-syphoning when the thermostatic valve is closed, no call for heat. Product range 00 series Isolation (two-pipe) panel radiator valve... / M radiator x /4" M pipe 0 series Isolation (two-pipe) angled panel radiator valve... / M radiator x /4" M pipe 02 series iverter (one-pipe) panel radiator valve with adjustable by-pass... / M radiator x /4" M pipe 0 series iverter (one-pipe) angled panel radiator valve with adjustable by-pass... / M radiator x /4" M pipe Technical specifications Materials - body: brass chrome-plated - valve control stems: brass chrome-plated - seals: PM - thermal break non-return device: PPO Performance Suitable fluids: water, glycol solutions Max. percentage of glycol: 0% Max. working pressure: 50 psi (0 bar) Max. working temperature: 22 (00 ) Max. differential pressure: 5 psi ( bar) djustable by-pass factory setting for one-pipe version: 5% of flow rate djustable by-pass setting range: 0-50% of flow rate

imensions 040 040 ode 0040 0040 0040 " 2 5 8" ode 040 040 " 2 7 8" 0040 ode 024 024 " 2 5 8" 024 04 ode 04 04 04 " 2 7 8" 024

ittings 68 Universal PX fittings 68 series fittings are compatible with any STM 876 single layer PX. Max. working pressure: 50 psi. Working temperature for STM 876 PX piping: -4 80º. hrome-plated. Radiator adapter fitting, code 94045, / irect connection ode escription 68524 nominal PX, thread female nut Radiator connection fitting, / iverter Valve (02, 0) Isolation Valve (00, 0) Radiator connection fitting, / Isolation ball valve (requires screwdriver) Isolation ball valve (requires screwdriver) Side access port with sealed threaded cap (6 mm allen wrench). /4" (metric) pipe thread /4" (metric) pipe thread djustable by-pass valve (requires 6 mm allen wrench under threaded cap) ode 682 Universal PX-L-PX fittings 682 series fittings are compatible with any STM 28 multilayer PX-L-PX pipe. Max. working pressure: 50 psi. Working temperature for STM 28 multilayer PX-L-PX piping: -4 67º with tubing rated 200º. escription 682540 nominal PX-L-PX, thread female nut ode 47 ompression fitting, for ½" hard copper. With o-ring seal. Max. working pressure: 50 psi (0 bar). Temperature range: - 250º (-25 20º). hrome-plated. escription 4756 compression, thread female nut N02 Sweat connection fitting. ode N0262 escription sweat, thread female nut

ccessories 4497 Wall-covering plate. or dual panel radiator valves 0. With wall connections. In white S. Outlet center distance: 40 50 mm 940 Radiator adapter for directly connecting a panel radiator to a manifold with PX, PX-L-PX, sweat or compression fittings. ode escription 449740 Plate ode escription 94045 M radiator x M pipe pplication diagrams One-pipe plumbing Two-pipe plumbing Manifold piping aleffi panel radiator valves are designed to be installed on panel radiators featuring connections both on the bottom and an externally invisible inner pipe, which feeds the flowing medium to the upper valve. They come in two versions: for two-pipe and one-pipe systems. oth are available (pipes exiting the floor) and angled (pipes exiting the wall). The two-pipe version is equipped with two ball shut-off valves; the one-pipe, in addition to the shut-off valves, is equipped with an adjustable by-pass from 0% to 50% of the flow rate towards the radiator, and a thermal break device () that prevents thermo-syphoning upward into radiator from by-passing flow. Since the radiators are in series in one-pipe systems, the downstream radiator receives water at a lower temperature than the upstream radiator. In most applications, it is recommended the number of radiators should be limited to to ensure sufficient heat delivery. Isolation valves and diverter valves are not necessary when directly connecting a panel radiator to manifold. Radiator adapter, code 94045, is used for direct pipe connection, PX, PX-L-PX, sweat or compression, to the radiator. () iverter valve (02, 0) () Isolation valve (00, 0) () Radiator adapter, code 94045 ow to adjust the by-pass on single one-pipe valves. Range: 0 50% 6mm 6mm The valve is supplied preset with 5% flow rate to the radiator. To change the flow rate, shut the by-pass valve and then unscrew the same by a number of turns equivalent to the required flow rate indicated in the graph. low rate % 55 50 45 40 5 0 low rate % 55 50 45 40 5 0 25 2 2.5.5 4 4.5 5 5.5 6 Number of turns 25 2 2.5.5 4 4.5 5 5 Number of turns

specification summaries 00 series Isolation panel radiator valve for one-pipe heating system. Straight-through flow pattern for floor pipe connections, copper and single and multilayer PX pipes. Radiator connections ½" male threads. Pipe connection ¾". rass body. hrome-plated. hrome-plated brass valve control stems, PM seals. Suitable fluids water, 0% max. glycol solutions. Maximum working temperature 22 (00 ). Maximum working pressure 50 psi (0 bar). 0 series Isolation panel radiator valve for one-pipe heating system. ngled flow pattern for wall pipe connections, copper and single and multilayer PX pipes. Radiator connections ½" male threads. Pipe connection ¾". rass body. hrome-plated. hrome-plated brass valve control stems, PM seals. Suitable fluids water, 0% max. glycol solutions. Maximum working temperature 22 (00 ). Maximum working pressure 50 psi (0 bar). 02 series iverter panel radiator valve for two-pipe heating system. Straight-through flow pattern for floor pipe connections, copper and single and multilayer PX pipes. djustable by-pass 0% to 50% of flow to radiator, factory-set 5%. PPO thermal break (non-return) device in return leg. Radiator connections ½" male threads. Pipe connection ¾". rass body. hrome-plated. hrome-plated brass valve control stems, PM seals. Suitable fluids water, 0% max. glycol solutions. Maximum working temperature 22 (00 ). Maximum working pressure 50 psi (0 bar). 0 series iverter panel radiator valve for two-pipe heating system. ngled flow pattern for wall pipe connections, copper and single and multilayer PX pipes. djustable by-pass 0% to 50% of flow to radiator, factory-set 5%. PPO thermal break (non-return) device in return leg. Radiator connections ½" male threads. Pipe connection ¾". rass body. hrome-plated. hrome-plated brass valve control stems, PM seals. Suitable fluids water, 0% max. glycol solutions. Maximum working temperature 22 (00 ). Maximum working pressure 50 psi (0 bar). We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice. aleffi North merica, Inc. 88 W. Milwaukee Road Milwaukee, WI 5208 Tel: 44-28-260 ax: 44-28-266 sales@caleffi.com www.caleffi.us opyright 202 aleffi North merica, Inc.