Heavy Duty, Industrial General Specifications XCKJ. Electrical Ratings Non-plug-in: A300 (AC), Q300 (DC)

Similar documents
International, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in.

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Miniaturized limit switches

Pre wired limit switches

ED SERIES SAFETY LIMIT SWITCH Description

ED SERIES SAFETY LIMIT SWITCH

Limit switches 3. Page 92. Page 92

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

3SE03 North American Limit Switches

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Safety Limit Switch

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Limit switches Osiswitch Classic Metal, conforming to CENELEC EN 50041, type XCK J Fixed or plug-in body Variable composition: standard bodies

3SE03 North American Limit Switches

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

ZCK-Y39 ZCK-Y49 ZCK-Y33 ZCK-Y34 ZCK-Y31 ZCK-D109 ZCK-D41 ZCK-D06 ZCK-M2H29 ZCK-M2H29

IEC Limit Switches Selection Guide

Manual Reset Limit Switch

Limit Switches - Limit Type (PS31L) Plastic Body IP65

IEC Limit Switches Selection Guide

FL series position switches

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Non-illuminated Push Buttons

LK Position Switches TECHNICAL DATASHEET.

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Contents. Limit Switches. Quick Selection Guide... page 6 2. Technical Definitions and Terminology... page 6 6

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Current Ratings All Limit Switch Types

Hinged Safety Door Switch

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches with Positive Opening Mechanism

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Position switches FR series

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Limit Switch - Prewired Type Metal Body

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Compact plastic limit switches with positive opening mechanism

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Model Number Structure

Position switches FC series

800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.

Safety-door Switch. Ordering Information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Single foot switches PX and PA series

Selector Push Button Cat. No. 800T-K2AAXX. a b c d e f g Right Left Right Left. d, e, f, g. Contact Blocks. No contacts on operator

Small Limit Switch D4V

Safety switches for hinged doors

Compact plastic limit switches with positive opening mechanism

Robust General-Purpose Limit Switch WL

Position switches FD series

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

LJASeries. Limit Switches with Positive Opening Mechanism

Single foot switches PX and PA series

the Interactive Catalog

Limit switches. Metal. Limit Switches Metal casing, 30mm, 40mm & 60mm

XCS Safety Interlock Selection

Comepi Limit Switches

Environment-Sealed Basic Switches

O bloco de contato XESP2031 é utilizado no corpo ZCKJ4* / ZCKJ404 é tem o seu acionamento escalonado, ou seja:

UL/CSA Non-fused Disconnect Switches

Compact Limit Switches

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

the Interactive Catalog

UL 508 Non-Fusible Disconnect Switches

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Safety Limit Switch

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Limit Switches E47 Precision Switches

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Switches with manual reset

Limit switches 0 ZCK E67 ZCK E23 ZCK E62. with contact, cable. entry for Pg 13, fi xed, 1 step (2) (3) ZCK JD3p, ZCK J1, J5, J6, J7, J9

Micro Contactor MA Series

UL 508 Non-Fusible Disconnect Switches

Available as assembled switches or components. E50ANR1 with E50KL200 Lever. Conduit, cable and connector wiring options

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Gross Automation (877)

Microswitches MK series

Position switches FR series

Ktec Contactors and thermal overloads

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

GLS Series Global limit switch

Bulletin 190-M Compact Starters. Selection Guide

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

Single foot switches - PX and PA series

Floor and fine adjustment switches

Transcription:

Heavy Duty, Industrial General Specifications Rated Power Conforms to IEC 947-5-1, duty categories AC15 and DC13. emperature range -13 F to 158 F (-25 C to 7 ); optional -4 F (-4 C); +248 F (12 C). he minimum temperatures listed are based on the absence of freezing moisture or water. NEMA ype 1,2,3,4,12 Enclosure rating IEC ype IP66 Vibration resistance 25G (1-5Hz), conforming to IEC 68-2-6 Shock resistance 5G, conforming to IEC 68-2-27 Repeatability (max.).4" (.1mm) Cable entry 1/2" NP standard Characteristics Rated thermal current 1A, conforming to UL 58, CSA C22-2 No.14, IEC 337-1, NFC 63-14, VDE 66-2 Rated insulation voltage Non-plug-in: 3Vac (A3) and DC (Q3) Plug-in: 6Vac (A6) and DC (Q6) resistance (max) Non plug-in: 25m W Plug-in: 45m W Cable (max.) 2 x #16 AWG (1.5mm 2 ) per terminal - 1 x #16 AWG for 2SPD (2N.O.-2N.C.) Short circuit protection 1A fuse type SC; Form I Class J or equivalent. Outside US use type gl or N. Electrical Ratings Non-plug-in: A3 (AC), Q3 (DC) Maximum make or break Volt 3Vac or DC. (M=Make, B=Break) Rating Designation Maximum current (Amp) Maximum 12 V 125 V 24 V 25 V 48 V 6 V Volt Amps M B M B M B M B M B M B M B A3 (AC) 6 6. 3 3. 72 72 Q3 (DC).55.55.27.27 Electrical Ratings Plug-in: A6 (AC), Q6 (DC) Maximum make or break Volt 6Vac or DC. (M=Make, B=Break) Rating Designation Maximum current (Amp) Maximum 12 V 125 V 24 V 25 V 48 V 6 V Volt Amps M B M B M B M B M B M B M B A6 (AC) 6 6. 3 3. 15 1.5 12 1.2 72 72 Q6 (DC).55.55.27.27.1.1 Caution: Use of the recommended fuse is mandatory to ensure positive opening operation. Without a fuse to protect the circuit, the contacts may develop a weld significant enough that the positive opening contact mechanism may not be able to break through the weld. XCK J1511 Complete Switches Non Plug-in Housingsc Description Functional Diagram Lever operated 23 58 (P) 9 Operating orque ype Direct Openingq DELRIN roller lever adjustable in 5 or 45 increments (reversible mountings)j 33.3 in oz SPD (N.O.+N.C.) Y 1511 $81. 33.3 in oz 2SPD (2N.O.+2N.C.) N 2511 96. Adjustable length DELRIN roller lever adjustable in 5 or 9 increments 33.3 in oz SPD (N.O.+N.C.) Y 1541 81. 33.3 in oz 2SPD (2N.O.+2N.C.) N 2541 96. Adjustable length - 1 /8" diameter steel rod adjustable in 5 or 45 increments 33.3 in oz SPD (N.O.+N.C.) Y 1553 81. XCK J1541 Adjustable length 1 /4" plastic rod adjustable in 5 or 45 increments 33.3 in oz SPD (N.O.+N.C.) Y 1559 88. c 2 or 3 subassemblies in a single referenced package. Other complete switches are available. Assembled switches can also be provided. your Square D/elemecanique representative for details. j Reverse mounting: he higher increment (45 or 9 ) is a positive opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the direct opening (N.C.) contact even if the lever is loosely mounted on the head shaft. Note: Information on the Safety Interlock can be found in Machine Safeguarding Products, Section 23. For additional information, reference # 97C971R8/98 or D-FAX M # 1559. 3/ Schedule 2 Square D -11

Current Ratings All Limit Switch ypes Square D www.squared.com FOR CURREN INFORMAION Configurations

Square D www.squared.com FOR CURREN INFORMAION Application Data

Heavy Duty, Industrial Complete Switches Neutral Position c One SPD contact switch per direction: past 2 CW contact 1 (/) switches; past 2 CCW contact 2 (/) switches. Levers not included. 161 167 Plunger Operated c 2 or 3 subassemblies in a single referenced package. Other complete switches are available. Assembled switches can also be provided. your Square D/elemecanique representative for details. j Reverse mounting: he higher increment (45 or 9 ) is a positive opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the direct opening (N.C.) contact even if the lever is loosely mounted on the head shaft. Plug-in Housings c Description Functional Diagram Lever Operated 23-22 23 2 2 9 9" 11.8.185(P).35 9.24 26.6 in oz. 2SPD (2N.O.+2N.C.) N ZCKJ44 $13. Rod plunger Operating orque SPD (N.O.+N.C.) Y 161 74. SPD (N.O.+N.C.) Y 167 8. ype Direct Opening q DELRIN roller lever adjustable in 5 or 45 increments (reversible mountings) j 33.3 in oz SPD (N.O.+N.C.) N 11511 $81. Adjustable length DELRIN roller lever adjustable in 5 or 9 increments 33.3 in oz SPD (N.O.+N.C.) N 11541 81. 11511 Neutral Position c One SPD contact switch per direction: past 2 CW contact 1 (/) switches; past 2 CCW contact 2 (/) switches. Levers not included. 1167 23-22 Plunger Operated 2 2 9 9" 11.8" 35" 24" 26.6 in oz 2SPD (2N.O.+2N.C.) N ZCKJ414 $13. Rod plunger 48 oz 48 oz SPD (N.O.+N.C.) N 1161 74. SPD (N.O.+N.C.) N 1167 8. c 2 or 3 subassemblies in a single referenced package. Other complete switches are available. Assembled switches can also be provided. your Square D/elemecanique representative for details. j Reverse mounting: he higher increment (45 or 9 ) is a positive opening contact feature which ensures no loss of mechanical effort between the actuation point and the moving contact bridge of the direct opening (N.C.) contact even if the lever is loosely mounted on the head shaft. See the Product for details. File E39281 CCN NKCR File LR 4487 Class 3211-3 Acceptable Wire Sizes...................................................... 14-24 AWG Recommended erminal Clamp orque............................................................... 13 in. lbs. For additional information, reference # 97C971R8/98 or D-FAX M # 1559. -12 2 Square D Schedule 3/

Operating Heads Lever Operating Heads operation with switch bodies: 1 Step 2 Step 1 Step Operating ZCK J1, J11, J2, J21 ZCK J4, J41 ZCK J5 Force/orque Standard operation 1 Step CW and /or CCW 23 58 (P) 9 23 4 (P) 33 9 2 Step, first step 23 5 9 33 in oz.,.25 N ZCKE5 $28.5, second step 42 5 9 Maintained operation - See the Product for recommended cam geometry 65 9 65 9 33 in oz.,.25 N ZCKE9 $38. Neutral Position - Heads are not available separately. Order complete switches from page -12. Plunger Operated Heads Operation with Switch Bodies: 1 Step 2 Step 1 Step Operating ZCK J1,J11,J2,J21 ZCK J4, J41 ZCK J5 Force/orque op rod plunger.8.185(p).35.24.8".35".24".8.135(p).125.24" ZCKE61 $28.5 Ball bearing top plunger One-way DELRIN roller (A) One way steel roller (A).5".114.261(P).4".35".24".114.3(P).182 ZCKE66 34.8 ZCKE67 34.8 ZCKE21 ZCKE21 31.7 31.7 ZCKE23 31.7 Side rod plunger.6".22".35".6.114 (P).16.217 ZCKE63 34.8 Side steel roller plunger-horizontal (A) Side steel roller plunger-vertical (A).6.145(P).35.6.17(P).15 ZCKE64 41.1 ZCKE65 41.1 Omnidirectional Headsc Cat whisker-steelc 2 18.4 in oz.,.13n ZCKE6 $28.5 2 45 Wobble coil springsc 1 18.4 in oz.,.13n ZCKE8 28.5 c Flexible operators will not guarantee direct (positive) opening operation. (A) Actuation by 3 cam. For additional information, reference # 97C971R8/98 or D-FAX M # 1559. -14 2 Square D Schedule 3/