mm mm mm (Height at the top of terminals) 14.4 kg

Similar documents
AgriCUltUre ConstrUCtion equipment generators emergency vehicles CleAning

USER, s. k SULFURIC ACID CAN CAUSE BLINDNESS OR A DANGER/POISON SHIELD EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPARKS, FLAMES, SMOKING

6 & 12 Volt Monobloc GEL Range

Automotive/LTV. A guide to the industry s best starting and deep cycle battery

/ Hydrometer Flame Arrestor Polypropylene Case Heat-Sealed Covers Low-Resistance Envelope Separators:

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. Gelled Electrolyte Range. Monobloc

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

TOTALFLOW Technical Bulletin 59 Lead Acid Battery Inspection and Maintenance Procedures

Haze Battery Company Ltd

EverExceed Spiral AGM Batteries

Chapter 3. Direct Current Power. MElec-Ch3-1

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

EXTREME POWER AND ENDURANCE

6 & 12 Volt Monobloc. Haze Battery Company Ltd

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

12 VOLT AUTOMOTIVE AND LIGHT COMMERCIAL - FULL LINE

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Battery Selection Guide

BATTERIES. Contents PRODUCT INFORMATION

OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES

EXTREME POWER AND ENDURANCE

Haze Battery Company Ltd

12/24V 30A AUTOMATIC/MANUAL WORKSHOP BATTERY CHARGER

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

EXTREME POWER AND ENDURANCE

Battery Performance Specifications

EXTREME POWER AND ENDURANCE

EV Power - Battery Control Unit Instructions. 8 Cell 24V

Guidelines for Battery Electric Vehicles in the Underground

Sealed Lead-Acid Batteries

12V 160A/24V 185A MANUAL WORKSHOP BATTERY CHARGER

Sealed Lead-Acid Batteries

THE U.S. ARMY BATTERY MAINTENANCE MANAGEMENT PROGRAM BATTERY MAINTENANCE MANAGEMENT PROGRAM

Batteries, Alternators, and Chargers

COMPONENT MAINTENANCE MANUAL. LT-Valve-Regulated Lead-Acid Batteries. Part Numbers Applicable to this CMM LT P

TELEDYNE BATTERY PRODUCTS

Twice the overall power and three times the life of conventional marine batteries. Up to 400 cycles at 80% depth of discharge!

Engineered to take you to the red line and the finish line

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

Twice the overall power and three times the life of conventional marine batteries. Up to 400 cycles at 80% depth of discharge!


COMPONENT MAINTENANCE MANUAL. LT-Valve-Regulated Lead-Acid Batteries. Part Numbers Applicable to this CMM LT P

Stays stronger. 2X the overall power and 3X the life. of conventional marine batteries.

APPLICATION MANUAL STARTING, LIGHTING & IGNITION (SLI) DRYCELL BATTERY GUIDE SIXTH EDITION

OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES

MAINTENANCE-FREE BATTERY CONSTRUCTION

Haze Battery Company Ltd

Applications. EMC tested

Power to keep you on the move

2006 MINI Cooper S GENINFO Battery - Overview - MINI

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA RG-131

PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 27106

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA RG-380E/44 Series

AGM / GEL BATTERY RANGE

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

Known Worldwide as the Highest Quality AGM Batteries for Marine, RV and Industrial Applications

Deep Cycle AGM Range VRLA

Battery Range Summary

THE BATTERY THAT GOES TO EXTREMES

Tubular Gel Technology For Solar Applications

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

EXTREME POWER AND ENDURANCE

OBE, OBEXU, ON BOARD Battery Chargers

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

FEATURES & BENEFITS. 10 year design 25 C

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)

POWER TO GET THE JOB DONE

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Battery. Charger Model: Save Important Safety Instructions

BS20 BATTERY CHARGER For lead-acid batteries

The Traveler Series: Wanderer

INSTRUCTION MANUAL CAUTION

/ Hydrometer Flame Arrestor Polypropylene Case Heat-Sealed Covers Low-Resistance Envelope Separators:

SPECIFICATIONS LOW COST 2404R CHARGER

Digital Intelligent Battery Charger OPERARATOR S MANUAL

Ampere Hour 77 F (25 C) Weight Weight Model #Cells/Voltage

ELECTRICAL. CDTA Technical Training Center

Gary Mackey National Sales Manager Associated Equipment Corporation

PS-Series General Purpose Batteries

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries

Product Guide. An Invensys company

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

TELEDYNE BATTERY PRODUCTS

LAWN & GARDEN PRODUCT ELECTRICAL SYSTEM INFORMATION FOR S 1612

Charge Voltage(V/cell) Set point (V) (V)

The Traveler Series: Wanderer

CELLS AND BATTERIES Understand the general features of cells and batteries Describe the relationship between cells and batteries. Describe the basic

Significant Changes and Amendments of the Edition of the ICAO Technical Instructions for the Safe Transport of Dangerous Goods by Air ( TI )

Pallet Pro On-Board Power System and 6 Volt Group 27 Deep Cycle Bloc Batteries GB A Division of Exide Technologies

EV Traction Dry Cell Battery Technology

Transcription:

Battery Model: 25 Part Number: 8025-160 Nominal Voltage: 12 volts NSN: Number applied for, product currently available Battery Model: 35 Part Number: 8020-164 Nominal Voltage: 12 volts NSN: Number applied for, product currently available Physical Characteristics: Plate Design: High purity lead-tin alloy. Wound cell configuration utilizing proprietary SPIRALCELL technology. Electrolyte: Sulfuric acid, H 2 SO 4 Case: Polypropylene Color: Case: Dark Gray Cover: OPTIMA Red Group Size: BCI: 25 & 35 Standard Metric Length: Width: Height: Weight: 9.340 6.700 7.685 31.7 lb 237.24 mm 170.18 mm 195.20 mm (Height at the top of terminals) 14.4 kg Terminal Configuration: SAE / BCI automotive. Performance Data: Open Circuit Voltage (Fully charged): Internal Resistance (Fully charged): Capacity: Reserve Capacity: 12.8 volts.0030 ohms 44 Ah (C/20) BCI: 90 minutes (25 amp discharge, 80 F (26.7 C), to 10.5 volts cut-off) Power: CCA (BCI 0 F): MCA (BCI 32 F): 720 amps 910 amps

Recommended Charging: The following charging methods are recommended to ensure a long battery life: (Always use a voltage regulated charger with voltage limits set as described below.) Model: 25 and 35 These batteries are designed for engine starting applications. They are not recommended or warranted for use in deep cycle applications. Recommended Charging Information: Alternator: Battery Charger (Constant Voltage): Float Charge: Rapid Recharge: (Constant voltage charger) 13.3 to 15.0 volts 13.8 to 15.0 volts; 10 amps maximum; 6-12 hours approximate 13.2 to 13.8 volts; 1 amp maximum; (indefinite time at lower voltages) Maximum voltage 15.6 volts. No current limit as long as battery temperature remains below 125 F (51.7 C). Charge until current drops below 1 amp. All limits must be strictly adhered to. Recharge Time: (example assuming 100% discharge 10.5 volts) Current Approximate time to 90% charge 100 amps 35 minutes 50 amps 75 minutes 25 amps 140 minutes Recharge time will vary according to temperature and charger characteristics. When using Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge. (All charge recommendations assume an average room temperature of 77 F (25 C). Always wear safety glasses when working with batteries. Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life. These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately. Not fully charging a battery can result in poor performance and a reduction in capacity.

Shipping and Transportation Information: OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800. Terminals must be protected from short circuit. Manufacturing Location: Enertec Exports S. de R.L. de C.V. RFC: EEX020516KU2 Avenida. del Parque No. 2155 Monterrey Technology Park Cienega de Flores, N.L. 65550 MEXICO Phone: 52 (81) 81542300 Fax: 52 (81) 81542301 BCI = Battery Council International OPTIMA Batteries Product Specifications: Model 25 and 35 December 2008

Battery Model: 75/25 Part Number: 8022-091 Nominal Voltage: 12 volts NSN: 6140 01 475 9361 Physical Characteristics: Plate Design: High purity lead-tin alloy. Wound cell configuration utilizing proprietary SPIRALCELL technology. Electrolyte: Sulfuric acid, H 2 SO 4 Case: Polypropylene Color: Case: Dark Gray Cover: OPTIMA Red Group Size: BCI: 75/25 Standard Metric Length: Width: Height: Weight: 9.340 6.772 7.697 33.1 lb 237.24 mm 172.01 mm 195.50 mm (Height at the top of terminals) 15.0 kg Terminal Configuration: SAE / BCI automotive and GM style side terminal (3/8-16UNC-2B threaded nut). Performance Data: Open Circuit Voltage (Fully charged): Internal Resistance (Fully charged): Capacity: Reserve Capacity: 12.8 volts.0030 ohms 44 Ah (C/20) BCI: 90 minutes (25 amp discharge, 80 F (26.7 C), to 10.5 volts cut-off) Power: CCA (BCI 0 F): MCA (BCI 32 F): 720 amps 910 amps Recommended Charging: The following charging methods are recommended to ensure a long battery life: (Always use a voltage regulated charger with voltage limits set as described below.) Model: 75/25 These batteries are designed for engine starting applications. They are not recommended or warranted for use in deep cycle applications.

Recommended Charging Information: Alternator: Battery Charger (Constant Voltage): Float Charge: Rapid Recharge: (Constant voltage charger) 13.3 to 15.0 volts 13.8 to 15.0 volts; 10 amps maximum; 6-12 hours approximate 13.2 to 13.8 volts; 1 amp maximum; (indefinite time at lower voltages) Maximum voltage 15.6 volts. No current limit as long as battery temperature remains below 125 F (51.7 C). Charge until current drops below 1 amp. All limits must be strictly adhered to. Recharge Time: (example assuming 100% discharge 10.5 volts) Current Approximate time to 90% charge 100 amps 35 minutes 50 amps 75 minutes 25 amps 140 minutes Recharge time will vary according to temperature and charger characteristics. When using Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge. (All charge recommendations assume an average room temperature of 77 F (25 C). Always wear safety glasses when working with batteries. Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life. These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately. Not fully charging a battery can result in poor performance and a reduction in capacity. Shipping and Transportation Information: OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800. Terminals must be protected from short circuit. Manufacturing Location: Enertec Exports S. de R.L. de C.V. RFC: EEX020516KU2 Avenida. del Parque No. 2155 Monterrey Technology Park Cienega de Flores, N.L. 65550 MEXICO Phone: 52 (81) 81542300 Fax: 52 (81) 81542301 BCI = Battery Council International OPTIMA Batteries Product Specifications: Model 75/25 December 2008

Battery Model: 34 Part Number: 8002-002 Nominal Voltage: 12 volts NSN: 6140 01 457 5296 Battery Model: 34R Part Number: 8003-151 Nominal Voltage: 12 volts NSN: 6140 01 475 9357 Physical Characteristics: Plate Design: High purity lead-tin alloy. Wound cell configuration utilizing proprietary SPIRALCELL technology. Electrolyte: Sulfuric acid, H 2 SO 4 Case: Polypropylene Color: Case: Dark Gray Cover: OPTIMA Red Group Size: BCI: 34 Standard Metric Length: Width: Height: Weight: 10.018 6.829 7.843 37.9 lb 254.46 mm 173.46 mm 199.21 mm (Height at the top of terminals) 17.2 kg Terminal Configuration: SAE / BCI automotive. Performance Data: Open Circuit Voltage (Fully charged): Internal Resistance (Fully charged): Capacity: Reserve Capacity: 12.8 volts.0030 ohms 50 Ah (C/20) BCI: 100 minutes (25 amp discharge, 80 F (26.7 C), to 10.5 volts cut-off) Power: CCA (BCI 0 F): MCA (BCI 32 F): 800 amps 1000 amps

Recommended Charging: The following charging methods are recommended to ensure a long battery life: (Always use a voltage regulated charger with voltage limits set as described below.) Model: 34 and 34R These batteries are designed for engine starting applications. They are not recommended or warranted for use in deep cycle applications. Recommended Charging Information: Alternator: Battery Charger (Constant Voltage): Float Charge: Rapid Recharge: (Constant voltage charger) 13.3 to 15.0 volts 13.8 to 15.0 volts; 10 amps maximum; 6-12 hours approximate 13.2 to 13.8 volts; 1 amp maximum; (indefinite time at lower voltages) Maximum voltage 15.6 volts. No current limit as long as battery temperature remains below 125 F (51.7 C). Charge until current drops below 1 amp. All limits must be strictly adhered to. Recharge Time: (example assuming 100% discharge 10.5 volts) Current Approximate time to 90% charge 100 amps 35 minutes 50 amps 75 minutes 25 amps 140 minutes Recharge time will vary according to temperature and charger characteristics. When using Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge. (All charge recommendations assume an average room temperature of 77 F (25 C). Always wear safety glasses when working with batteries. Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life. These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately. Not fully charging a battery can result in poor performance and a reduction in capacity.

Shipping and Transportation Information: OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800. Terminals must be protected from short circuit. Manufacturing Location: Enertec Exports S. de R.L. de C.V. RFC: EEX020516KU2 Avenida. del Parque No. 2155 Monterrey Technology Park Cienega de Flores, N.L. 65550 MEXICO Phone: 52 (81) 81542300 Fax: 52 (81) 81542301 BCI = Battery Council International OPTIMA Batteries Product Specifications: Model 34 and 34R December 2008

Battery Model: 34/78 Part Number: 8004-003 Nominal Voltage: 12 volts NSN: 6140 01 457 4339 Physical Characteristics: Plate Design: High purity lead-tin alloy. Wound cell configuration utilizing proprietary SPIRALCELL technology. Electrolyte: Sulfuric acid, H 2 SO 4 Case: Polypropylene Color: Case: Dark Gray Cover: OPTIMA Red Group Size: BCI: 34/78 Standard Metric Length: Width: Height: Weight: 10.018 6.886 7.841 38.8 lb 254.46 mm 174.90 mm 199.16 mm (Height at the top of terminals) 17.6 kg Terminal Configuration: SAE / BCI automotive and GM style side terminal (3/8-16UNC-2B threaded nut). Performance Data: Open Circuit Voltage (Fully charged): Internal Resistance (Fully charged): Capacity: Reserve Capacity: 12.8 volts.0030 ohms 50 Ah (C/20) BCI: 100 minutes (25 amp discharge, 80 F (26.7 C), to 10.5 volts cut-off) Power: CCA (BCI 0 F): MCA (BCI 32 F): 800 amps 1000 amps Recommended Charging: The following charging methods are recommended to ensure a long battery life: (Always use a voltage regulated charger with voltage limits set as described below.) Model: 34/78 These batteries are designed for engine starting applications. They are not recommended or warranted for use in deep cycle applications.

Recommended Charging Information: Alternator: Battery Charger (Constant Voltage): Float Charge: Rapid Recharge: (Constant voltage charger) 13.3 to 15.0 volts 13.8 to 15.0 volts; 10 amps maximum; 6-12 hours approximate 13.2 to 13.8 volts; 1 amp maximum; (indefinite time at lower voltages) Maximum voltage 15.6 volts. No current limit as long as battery temperature remains below 125 F (51.7 C). Charge until current drops below 1 amp. All limits must be strictly adhered to. Recharge Time: (example assuming 100% discharge 10.5 volts) Current Approximate time to 90% charge 100 amps 35 minutes 50 amps 75 minutes 25 amps 140 minutes Recharge time will vary according to temperature and charger characteristics. When using Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge. (All charge recommendations assume an average room temperature of 77 F (25 C). Always wear safety glasses when working with batteries. Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life. These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately. Not fully charging a battery can result in poor performance and a reduction in capacity. Shipping and Transportation Information: OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800. Terminals must be protected from short circuit. Manufacturing Location: Enertec Exports S. de R.L. de C.V. RFC: EEX020516KU2 Avenida. del Parque No. 2155 Monterrey Technology Park Cienega de Flores, N.L. 65550 MEXICO Phone: 52 (81) 81542300 Fax: 52 (81) 81542301 BCI = Battery Council International OPTIMA Batteries Product Specifications: Model 34/78 December 2008

Battery Model: 6V Part Number: 8010-044 Nominal Voltage: 6 volts NSN: 6140 01 475 9414 Physical Characteristics: Plate Design: High purity lead-tin alloy. Wound cell configuration utilizing proprietary SPIRALCELL technology. Electrolyte: Sulfuric acid, H 2 SO 4 Case: Polypropylene Color: Case: Dark Gray Cover: OPTIMA Red Group Size: BCI: N/A Standard Metric Length: Width: Height: Weight: 10.030 3.578 8.081 18.5 lb 254.76 mm 90.88 mm 205.26 mm (Height at the top of terminals) 8.4 kg Terminal Configuration: SAE / BCI automotive. Performance Data: Open Circuit Voltage (Fully charged): Internal Resistance (Fully charged): Capacity: Reserve Capacity: 6.4 volts.0019 ohms 50 Ah (C/20) BCI: 100 minutes Power: CCA (BCI 0 F): MCA (BCI 32 F): 800 amps 1000 amps Recommended Charging: The following charging methods are recommended to ensure a long battery life: (Always use a voltage regulated charger with voltage limits set as described below.) Model: 6V These batteries are designed for engine starting applications. They are not recommended or warranted for use in deep cycle applications.

Recommended Charging Information: Alternator: Battery Charger (Constant Voltage): Float Charge: Rapid Recharge: (Constant voltage charger) 6.65 to 7.5 volts 6.9 to 7.5 volts; 10 amps maximum; 6-12 hours approximate 6.6 to 6.9 volts; 1 amp maximum; (indefinite time at lower voltages) Maximum voltage 7.8 volts. No current limit as long as battery temperature remains below 125 F (51.7 C). Charge until current drops below 1 amp. All limits must be strictly adhered to. Recharge Time: (example assuming 100% discharge 5.5 volts) Current Approximate time to 90% charge 100 amps 35 minutes 50 amps 75 minutes 25 amps 140 minutes Recharge time will vary according to temperature and charger characteristics. When using Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge. (All charge recommendations assume an average room temperature of 77 F (25 C). Always wear safety glasses when working with batteries. Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life. These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately. Not fully charging a battery can result in poor performance and a reduction in capacity. Shipping and Transportation Information: OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800. Terminals must be protected from short circuit. Manufacturing Location: Enertec Exports S. de R.L. de C.V. RFC: EEX020516KU2 Avenida. del Parque No. 2155 Monterrey Technology Park Cienega de Flores, N.L. 65550 MEXICO Phone: 52 (81) 81542300 Fax: 52 (81) 81542301 BCI = Battery Council International OPTIMA Batteries Product Specifications: Model 6V January 2010