FCX TECHNICAL BOOKLET

Similar documents
CENTRIFUGAL FAN COIL UNIT VCE

WE MAKE INDOOR AIR BETTER

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

VHIA High-Static Ducted Indoor Units - 60HZ

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

WATER SOURCE HEAT PUMPS

CHP

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

High Static Pressure Duct Fan Coil Unit

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

BAC / BHC Product Specifications

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Fluid Cooling Mobile AOHM / AOVHM Series

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

Vertical Floor Fan Coil Unit (Model FW)

Carisma The Ultra Quiet Fan Coil

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

CHILLED WATER FAN-COIL UNITS

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Package Air Conditioners

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

Vertical Hi-Rise Fan Coil Unit (Model FS)

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

#7 Stock Cabinet Fan/Coils

DESCRIPTION FEATURES

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

PCB COMMERCIAL SERIES

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

BAC / BHC SERIES 6 to 20 Ton Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Low Static Pressure Duct(V shape evaporator)

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

D M S 760 C01 A A 1 1

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

HCH6. Product Specifications

Transcription:

FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply. The reader is encouraged to refer to the original manual if addi onal informa on is desired. Page 1 of 20

All the information in this manual has been taken from the full FCX US, USP & USPO Technical and Installation Booklet published by AERMEC and the reader is encouraged to refer to this original document to find additional information. Available here > https://www.phoenixenergysupply.com/wp-content/uploads/2017/05/fcx- USUSPUSPO-Technical-and-Installation-Booklet-84p.pdf Contact Phoenix Energy Supply (315) 253-3720 if need additional information. The equipment should be installed so that maintenance and/or repair services are possible and convenient. AERMEC S.p.A. and Phoenix Energy Supply declines all responsibility for any damage whatsoever caused by improper use of the machine, and a partial or superficial acquaintance with the product. This manual has 20 pages. FCX US - 1~ 120 V 60 Hz 2 versions US & USPO,7 sizes with 3-row coil FCX 22, 32, 42, 50, 62, 82, 102* FCX USPO MAIN COMPONENTS 1 Control panel (optional) 2 Heat exchanger 3 Air filter 4 Cabinet (RAL9002) 5 Fan motor 6 Fan 7 Bearing structure 8 Condensate discharge 9 Water connections 10 Head with adjustable louvers Page 2 of 20

DESCRIPTION OF COMPONENTS HEAT EXCHANGE COIL Coil is aluminum finned copper tube core secured by mechanical tube expansion. Manifolds are fitted with female connectors and air vents in the upper section of the coil. FILTER SECTION Made from recyclable materials, removable for easy cleaning. USP and USPO versions: Filter fire resistance is Class 2 (UL900). The easy to remove air filter is delivered in sealed packaging together with the fan coil. The packaging should only be opened at the time of installation. The electrostatically pre-charged air filter combines normal, mechanical filtration of the air passing through it with an electrostatic filtration that attracts dust and significantly improves performance. The filter is in fact 5 times more effective than normal filters in retaining dust particles below one micron in diameter. The filter's electrostatic charge lasts for 2 years after the protective packaging is opened. After this, the filter acts only as a normal filter. For this reason, it is important to replace the filter with a new one at these intervals. Clean the filter frequently. Use a vacuum cleaner to remove built up dust. Avoid water or detergents if possible since they greatly accelerate loss of the filter's electrostatic charge. CABINET HOUSING (RAL9002) Only in FCX US version. Made from specially treated sheet metal, for high resistance to rust and corrosion. VERSIONS US: the upper section features a heat-molded plastic louver for air diffusion. The housing front also features a heat-molded plastic air intake grille. FAN ASSEMBLY Twin-suction centrifugal fans (6) with longer blade for high capacity yield at low rpm. The electric motor (5) has an overload cut-out device and runs at three speeds (7 in USPO version); the permanently engaged running capacitor is directly coupled to the fans, and is positioned on vibration-damping elastic supports. MAIN FRAME Made from adequately sized galvanized sheet steel. The rear section features holes for wall-mounting. Hanging models also feature a front cover panel over the fan assembly. All units come with condensate tray. Brackets (AMP) can also be supplied for ceiling installation of the unit. CONDENSATE DRAIN Connection for drainage of condensate produced by the cooling unit. WATER CONNECTIONS The unit features female connectors on the left side. The coil can be rotated as necessary. SELECTION CRITERIA Vertical cabinet versions (US) feature frontal air intake, and are suited for vertical wall installation. Hanging versions (USPO) come without housing and feature rear section air intake; these versions are suited for horizontal installation. The USPO version (with multiple-speed extra-strength motor) guarantees adequate available static pressure values for correct air delivery in ducting applications in which pressure drop is significant. The US & USPO versions are available with 3-row coils. Tables 1 and 2 give technical data for FCX 3-row coils. Operating limits of fan coil are shown on page 5. Tables from 6a to 6g give the sensible and total cooling capacity values at maximum speed, at various inlet water temperatures, dry bulb and wet bulb temperatures. Performance at medium and low speeds for 3-row models can be obtained by applying the corrective coefficients shown on page 6 in Table 4. The graphs on page 7 & 8 illustrate the heating capacity at maximum speed, according to entering water temperature and various water flow rates. For lower speeds, refer to the corrective coefficients given in Table 5 on page 6. For ducted hanging versions (USPO), performance data collected as above refer to air flow values equal to those of corresponding models of other versions (US) at maximum speed (nominal flow values). USPO series fan coils have been designed to adjust available static pressure provided by the fan to pressure drop in the ducting system by selecting the appropriate operating speed. Table 6 on page 6 give the available air flow (cfm) at various external static pressures (pressure drop of ductwork and filters) of machines fitted with multiple-speed extra-strength motors, according to air flow and fan speed (1 High to 7 Low). The data in Table 8 on page 16 and associated graph show the pressure drop values (water side) for 3-row coils. Tables 9 and 10 give sound power and sound pressure level of fan coils operating at different speeds. In the case of ducted hanging versions, the sound power level is expressed in accordance with air flow and available static pressure (graphs on page 17). To size ducted hanging fan coils, proceed as follows: choose a unit size which, in nominal capacity conditions, has a capacity rating immediately above that required; using expected duct pressure drop use Table 6 on page 6 determine expected cfm and appropriate fan speed, then identify machine performance at different operating speeds. Based on the air flow values obtained, use the correction factors to calculate capacity in real air flow conditions. This procedure will indicate the correct unit speed setting on multiple-speed fan coil versions. Page 3 of 20

TABLE 1 FCX US DATA FCX Mod. FCX US (3 row) 22 32 42 50 62 82 102 Hea ng Capacity max. BTU/Hr 11,612 16,991 25,272 29,439 44,124 51,706 58,126 med. BTU/Hr 9,221 13,951 21,908 25,716 37,362 45,593 52,047 min. BTU/Hr 6,540 11,543 17,469 18,510 28,448 36,781 42,895 Hea ng capacity (water in 122 F) BTU/Hr 7,172 10,792 14,480 17,691 24,214 27,287 35,108 Water Flow gpm 1.29 1.88 2.80 3.26 4.89 5.72 6.45 Water Pressure Drop FOH 2.11 4.76 4.72 4.76 4.96 6.64 5.56 Total Cooling Capacity Sensible Cooling Capacity max. BTU/Hr 5,123 8,196 11,612 14,310 16,598 23,599 26,024 med. BTU/Hr 4,542 7,018 9,563 12,431 15,915 18,783 24,384 min. BTU/Hr 3,603 5,362 7,889 9,699 13,490 16,085 21,413 max. BTU/Hr 4,235 6,489 9,426 10,246 14,480 17,076 18,886 med. BTU/Hr 3,603 5,259 7,223 9,392 11,987 14,515 17,021 min. BTU/Hr 2,578 3,757 5,584 6,967 9,648 11,782 14,559 Water flow gpm 1.14 1.82 2.58 3.17 3.68 5.24 5.77 Water Pressure Drop FOH 1.94 5.56 4.79 6.47 3.89 4.52 6.43 Air flow max. cfm 171 265 353 424 541 671 765 med. cfm 129 206 271 353 424 547 659 min. cfm 82 153 194 235 306 412 530 Fan Number 1 2 2 2 3 3 3 Sound Pressure Level Sound Power Level max. db (A) 39.5 38.5 42.5 47.5 47.0 52.5 56.5 med. db (A) 33.0 32.5 35.5 42.5 40.5 47.5 52.5 min. db (A) 23.0 25.5 28.5 33.5 31.5 42.5 46.5 max. db (A) 48.0 48.0 51.0 56.0 55.5 61.0 65.0 med. db (A) 41.5 41.0 44.0 51.0 49.0 56.0 61.0 min. db (A) 31.5 34.0 37.0 42.0 40.0 51.0 55.0 Water Volume gal 0.21 0.29 0.39 0.39 0.67 0.67 0.67 Coil Connec ons FPT 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Net Weight (FCX US) lbm 33.0 44.0 52.8 48.4 74.8 74.8 74.8 ELECTRICAL DATA Power supply = 1~ 120 V 60 Hz Max. Motor Power Wa s 25 44 57 67 82 106 131 Max. Input Current Amps 0.12 0.21 0.28 0.35 0.40 0.49 0.58 Performances per the following condi ons: Hea ng: Water In = 158 F ; Air In = 68 F ; Delta T Water = 50 F maximum fan speed; for medium and minimum fan speed water flow as per maximum speed; Hea ng: Air In = 68 F ; Water In = 122 F; Maximum Fan Speed; Water Flow as in Cooling Opera on; cooling: Air In = 81 F d.b. ; 66 F w.b. ; Water In = 45 F ; Delta T Water = 41 o F Maximum Fan Speed for medium and minimum fan speed water flow as per maximum speed; Sound Pressure Level (weighted A) measured in room with 3,002 3 volume and reverbera on me of 0.5 seconds. Page 4 of 20

TABLE 2 FCX USPO DATA FCX Mod. FCX US (3 row) 22 32 42 50 62 82 Hea ng Capacity max. BTU/Hr 11,612 16,991 25,272 29,439 44,124 51,706 Hea ng capacity (water in 122 F) BTU/Hr 7,172 10,792 14,480 17,691 24,214 27,287 Water Flow gpm 1.29 1.88 2.80 3.26 4.89 5.72 Water Pressure Drop FOH 2.11 4.76 4.72 4.76 4.96 6.64 Total Cooling Capacity max. BTU/Hr 5,123 8,196 11,612 14,310 16,598 23,599 Sensible Cooling Capacity max. BTU/Hr 4,235 6,489 9,426 10,246 14,480 17,076 Water flow gpm 1.14 1.82 2.58 3.17 3.68 5.24 Water Pressure Drop FOH 1.94 5.56 4.79 6.47 3.89 4.52 Air flow max. cfm 171 265 353 424 541 671 Fan Number 1 2 2 2 3 3 Sound Pressure Level max. db (A) 49.5 44.0 50.0 50.5 53.5 55.5 Sound Power Level max. db (A) 58.0 52.5 58.5 59.0 62.0 64.0 Water Volume gal 0.21 0.29 0.39 0.39 0.67 0.67 Coil Connec ons FPT 1/2 1/2 3/4 3/4 3/4 3/4 Net Weight (FCX USPO) lbm 30.9 41.9 50.7 50.7 75.0 75.0 ELECTRICAL DATA Power supply = 1~ 120 V 60 Hz Max. Motor Power Wa s 54 97 111 82 97 135 Max. Input Current Amps 0.25 0.45 0.51 0.36 0.48 0.62 Performances per the following condi ons: Hea ng: Water In = 158 F ; Air In = 68 F ; Delta T Water = 50 F maximum fan speed; for medium and minimum fan speed water flow as per maximum speed; Hea ng: cooling: Air In = 68 F ; Water In = 122 F; Maximum Fan Speed; Water Flow as in Cooling Opera on; Air In = 81 F d.b. ; 66 F w.b. ; Water In = 45 F ; Delta T Water = 41 o F Maximum Fan Speed for medium and minimum fan speed water flow as per maximum speed; Sound Pressure Level (weighted A) measured in room with 3,002 3 volume and reverbera on me of 0.5 seconds. OPERATING LIMITS Maximum water inlet temperature...176 F Maximum working pressure...115 psi Ambient Room Temperature.32-113 F Average minimum water temperature To prevent the formation of condensation on the exterior of the unit while the fan is operating, the average water temperature should not drop beneath the limits shown in the table below, determined by the ambient conditions. These limits refer to unit operation with fan at minimum speed. Note that condensation may form on the exterior of the unit if cold water circulates through the coil while the fan is off for prolonged periods of time, so it is advisable to fit the additional three-way valve. Page 5 of 20

TABLE 3 FCX US/USPO WATER FLOW LIMITS Mod. FCX US/USPO (3 row) 22 32 42 50 62 82 102 min. gpm 0.44 0.44 0.66 0.66 1.32 1.32 1.32 Water Flow Limits max. gpm 3.30 3.30 4.84 4.84 9.68 9.68 9.68 The cooling capacities in tables 6a-6g are with fan in maximum speed. For the other speeds, the values must be multiplied by the following factors: TABLE 4 FCX US/USPO COOLING CAPACITY CORRECTION FACTORS FOR MED/MIN FAN SPEED Mod. FCX US/USPO (3 row) 22 32 42 50 62 82 102 Medium Speed Total Capacity 0.89 0.86 0.82 0.87 0.96 0.80 0.94 Sensible Capacity 0.85 0.81 0.77 0.92 0.83 0.85 0.90 Minimum Speed Total Capacity 0.70 0.65 0.68 0.68 0.81 0.68 0.82 Sensible Capacity 0.61 0.58 0.59 0.68 0.67 0.69 0.77 The heating capacities are also with fan in maximum speed. For the other speeds, the values must be multiplied by the following factors: TABLE 5 FCX US/USPO HEATING CAPACITY CORRECTION FACTORS FOR MED/MIN FAN SPEED Mod. FCX US/USPO (3 row) 22 32 42 50 62 82 102 Medium Speed Total Capacity 0.79 0.82 0.87 0.87 0.85 0.88 0.90 Minimum Speed Total Capacity 0.56 0.68 0.69 0.63 0.64 0.71 0.74 TABLE 6 FCX USPO AIR FLOW CFM vs EXT STATIC vs SPEED TAP External Sta c Pressure (in. wg) External Sta c Pressure (in. wg) TAP 0.05 0.1 0.15 0.2 0.25 0.3 TAP 0.05 0.1 0.15 0.2 0.25 0.3 1 279 1 2 267 2 670 3 275 227 3 675 595 FCX 22 4 274 223 178 FCX 50 4 660 600 527 438 5 241 194 148 5 500 400 6 190 142 6 7 142 7 1 1 902 2 452 2 930 865 3 457 386 3 875 804 718 FCX 32 4 427 350 278 FCX 62 4 920 853 775 682 544 5 375 300 5 904 838 760 658 510 6 290 6 788 720 640 540 7 7 643 583 510 1 548 1 1100 2 598 532 2 1140 1054 3 604 545 482 3 1145 1068 976 FCX 42 4 568 506 450 394 FCX 82 4 1118 1036 948 844 5 552 491 431 329 330 5 1059 972 875 764 6 444 386 6 905 835 757 7 347 7 752 Page 6 of 20

Hea ng Capacity Charts - Capacity (Btu/Hr) is displayed on the ver cal axis as a func on of Entering Water Temperature ( o F) for various water flow rates (gpm). Page 7 of 20

Hea ng Capacity Charts - Capacity (Btu/Hr) is displayed on the ver cal axis as a func on of Entering Water Temperature ( o F) for various water flow rates (gpm). Page 8 of 20

TABLE 6a FCX US/USPO 22 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) Page 9 of 20 SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 4,224 5,906 7,691 3,634 4,275 4,893 5,425 5,947 6,452 7.2 3,787 5,388 7,131 8,916 10,792 3,320 3,965 4,606 5,159 5,695 6,220 9.0 3,235 4,681 6,459 8,325 10,246 2,948 3,576 4,217 4,879 5,439 5,974 10.8 2,955 3,982 5,722 7,677 9,642 2,777 3,258 3,835 4,511 5,156 5,708 12.6 3,579 4,900 6,920 8,977 2,620 3,095 3,525 4,118 4,801 5,428 5.4 3,702 5,306 7,117 8,916 3,344 3,972 4,613 5,156 5,688 6,189 7.2 3,286 4,732 6,541 8,325 10,216 2,986 3,644 4,272 4,886 5,428 5,954 9.0 2,856 4,088 5,804 7,704 9,642 2,682 3,258 3,900 4,552 5,166 5,705 10.8 2,658 3,463 5,043 7,039 9,008 2,532 3,009 3,542 4,193 4,852 5,439 12.6 3,228 4,255 6,179 8,312 2,382 2,866 3,306 3,818 4,483 5,152 5.4 3,235 4,681 6,459 8,325 3,020 3,637 4,306 4,886 5,422 5,923 7.2 2,869 4,118 5,865 7,704 9,612 2,672 3,334 3,975 4,606 5,162 5,684 9.0 2,559 3,525 5,118 7,070 9,008 2,453 2,965 3,603 4,231 4,886 5,442 10.8 2,412 3,098 4,367 6,281 8,342 2,296 2,777 3,252 3,886 4,524 5,162 12.6 2,890 3,777 5,449 7,616 2,139 2,614 3,088 3,535 4,173 4,842 5.4 2,856 4,088 5,804 7,704 2,709 3,354 3,972 4,603 5,145 5,671 7.2 2,552 3,569 5,159 7,070 8,977 2,392 3,040 3,661 4,299 4,879 5,425 9.0 2,330 3,074 4,473 6,353 8,356 2,214 2,682 3,313 3,920 4,572 5,166 10.8 2,788 3,818 5,545 7,660 2,057 2,532 3,009 3,579 4,214 4,879 12.6 3,392 4,743 6,814 1,904 2,375 2,863 3,299 3,852 4,528 5.4 2,559 3,525 5,210 7,070 2,436 3,037 3,682 4,303 4,876 5,398 7.2 2,289 3,095 4,483 6,408 8,325 2,133 2,706 3,357 3,978 4,606 5,156 9.0 2,102 2,672 3,879 5,596 7,677 1,979 2,446 2,996 3,620 4,265 4,893 10.8 2,518 3,296 4,845 6,889 1,822 2,296 2,774 3,296 3,914 4,562 12.6 3,033 4,088 6,012 1,662 2,139 2,614 3,084 3,572 4,197 5.4 2,330 3,074 4,473 6,353 8,356 2,160 2,726 3,364 3,968 4,596 5,135 7.2 2,023 2,716 3,869 5,637 7,646 1,890 2,426 3,061 3,661 4,299 4,883 9.0 2,433 3,334 4,889 6,950 1,740 2,211 2,695 3,340 3,955 4,589 10.8 2,927 4,169 6,073 1,583 2,057 2,528 3,016 3,624 4,248 12.6 3,589 5,261 1,416 1,904 2,375 2,866 3,303 3,900 5.4 2,668 3,879 5,596 7,677 1,880 2,453 3,047 3,678 4,289 4,859 7.2 2,443 3,337 4,889 6,933 1,658 2,146 2,733 3,364 3,982 4,603 9.0 2,204 2,914 4,224 6,125 1,505 1,976 2,446 3,030 3,641 4,272 10.8 2,617 3,620 5,306 1,341 1,822 2,296 2,771 3,327 3,927 12.6 3,183 4,535 1,167 1,662 2,139 2,607 3,084 3,610 5.4 2,433 3,334 4,889 6,950 1,593 2,177 2,743 3,371 3,965 4,582 7.2 2,173 2,914 4,255 6,145 1,419 1,890 2,457 3,074 3,668 4,296 9.0 2,569 3,661 5,336 1,262 1,740 2,211 2,726 3,361 3,961 10.8 2,392 3,132 4,606 1,099 1,583 2,057 2,528 3,033 3,651 12.6 2,866 3,900 908 1,416 1,904 2,375 2,852 3,323 5.4 2,204 2,914 4,224 6,125 1,338 1,897 2,467 3,057 3,678 4,275 7.2 2,600 3,610 5,326 1,181 1,655 2,177 2,760 3,374 3,975 9.0 2,313 3,142 4,606 1,020 1,501 1,972 2,457 3,057 3,651 10.8 2,750 3,941 839 1,341 1,822 2,289 2,771 3,354 12.6 3,371 618 1,167 1,662 2,139 2,607 3,078

TABLE 6b FCX US/USPO 32 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) Page 10 of 20 SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 6,790 5,415 6,404 7,169 7,885 8,585 7.2 5,995 8,452 10,823 5,005 5,940 6,858 7,612 8,346 9,032 9.0 5,244 7,506 10,110 12,669 4,558 5,500 6,483 7,309 8,059 8,782 10.8 4,562 6,643 9,270 11,959 14,702 4,030 5,040 6,012 6,967 7,742 8,489 12.6 3,944 5,766 8,322 11,154 13,969 3,692 4,528 5,531 6,493 7,411 8,185 5.4 5,879 8,305 4,988 5,903 6,783 7,517 8,223 8,922 7.2 5,214 7,459 9,980 4,555 5,473 6,421 7,240 7,977 8,670 9.0 4,579 6,595 9,229 11,816 14,539 4,084 5,060 6,012 6,916 7,691 8,417 10.8 3,914 5,749 8,223 11,058 13,829 3,610 4,579 5,534 6,500 7,370 8,124 12.6 3,555 4,937 7,278 10,222 13,071 3,357 4,091 5,067 6,039 7,018 7,803 5.4 5,050 7,370 4,517 5,480 6,394 7,141 7,854 8,568 7.2 4,466 6,514 9,100 11,628 4,057 5,019 5,940 6,851 7,609 8,322 9.0 3,961 5,749 8,189 10,918 13,638 3,658 4,593 5,514 6,483 7,309 8,052 10.8 3,480 4,968 7,247 10,127 12,928 3,252 4,125 5,101 6,039 6,978 7,742 12.6 3,228 4,268 6,319 9,100 12,123 3,026 3,692 4,623 5,562 6,517 7,425 5.4 4,350 6,384 8,905 4,016 4,999 5,899 6,769 7,489 8,196 7.2 3,914 5,643 8,124 10,727 3,668 4,569 5,469 6,459 7,223 7,960 9.0 3,490 4,954 7,182 9,980 12,740 3,252 4,129 5,084 6,019 6,920 7,677 10.8 3,115 4,303 6,336 9,069 11,959 2,907 3,668 4,651 5,562 6,500 7,367 12.6 3,750 5,521 8,042 11,106 2,692 3,357 4,149 5,118 6,060 7,025 5.4 3,862 5,466 8,011 3,634 4,524 5,473 6,380 7,117 7,834 7.2 3,528 4,889 7,083 9,816 3,265 4,125 5,026 5,988 6,844 7,578 9.0 3,122 4,268 6,254 8,939 11,792 2,832 3,709 4,623 5,527 6,490 7,298 10.8 3,740 5,456 7,994 10,963 2,576 3,265 4,180 5,135 6,046 6,971 12.6 3,374 4,726 6,971 9,980 2,351 3,026 3,716 4,678 4,671 6,561 5.4 3,490 4,685 6,937 3,241 4,033 4,995 5,893 6,739 7,459 7.2 3,139 4,190 6,125 8,840 11,533 2,866 3,692 4,593 5,524 6,456 7,216 9.0 3,757 5,360 7,831 10,799 2,457 3,299 4,200 5,098 6,015 6,906 10.8 3,334 4,709 6,906 9,929 2,303 2,907 3,733 4,692 5,606 6,500 12.6 4,091 6,012 8,810 2,006 2,692 3,357 4,241 5,145 6,067 5.4 3,108 4,057 5,930 8,598 2,849 3,641 4,535 5,459 6,357 7,090 7.2 3,733 5,261 7,701 10,564 2,450 3,299 4,108 5,036 5,981 6,831 9.0 3,368 4,661 6,790 9,769 2,126 2,883 3,743 4,644 5,568 6,479 10.8 4,084 5,995 8,728 1,897 2,576 3,316 4,251 5,156 6,053 12.6 3,569 5,179 7,701 1,658 2,351 3,026 3,760 4,719 5,647 5.4 3,675 5,050 7,541 2,450 3,258 4,043 4,999 5,879 6,715 7.2 3,351 4,490 6,643 9,557 2,023 2,900 3,716 4,599 5,524 6,435 9.0 4,026 5,865 8,581 1,788 2,470 3,340 4,227 5,108 6,009 10.8 3,596 5,149 7,523 1,552 2,242 2,921 3,784 4,719 5,620 12.6 4,480 6,630 1,286 2,006 2,692 3,374 4,292 5,203 5.4 3,303 4,343 6,442 2,044 2,866 3,658 4,483 5,452 6,333 7.2 3,937 5,684 8,400 1,675 2,491 3,327 4,125 5,036 5,964 9.0 3,596 5,009 7,394 1,447 2,126 2,934 3,774 4,668 5,568 10.8 4,439 6,500 1,191 1,897 2,576 3,374 4,289 5,166 12.6 3,862 5,684 880 1,658 2,351 3,026 3,825 4,784

TABLE 6c FCX US/USPO 42 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) Page 11 of 20 SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 9,796 7,970 9,315 10,536 11,604 12,676 7.2 7,356 10,611 14,470 18,183 6,551 7,957 9,390 10,693 11,833 12,935 9.0 6,169 9,270 13,051 17,094 21,124 5,623 7,210 8,632 10,082 11,328 12,464 10.8 5,466 7,773 11,492 15,815 19,974 5,268 6,312 7,841 9,339 10,765 11,966 12.6 8,499 11,932 7,271 8,673 9,956 11,055 12,119 5.4 7,390 10,587 14,310 6,616 8,015 9,400 10,618 11,727 12,792 7.2 6,411 9,315 13,075 16,934 20,902 5,821 7,312 8,714 10,106 11,270 12,379 9.0 5,333 7,994 11,690 15,784 19,844 5,104 6,510 7,974 9,397 10,748 11,904 10.8 4,971 6,565 10,106 14,344 18,630 4,784 5,749 7,145 8,626 10,069 11,393 12.6 7,322 10,478 6,582 7,970 9,315 10,495 11,577 12,631 5.4 6,421 9,356 13,051 16,712 5,937 7,370 8,711 10,035 11,174 12,256 7.2 5,531 8,104 11,601 15,624 19,622 5,196 6,633 7,994 9,417 10,690 11,823 9.0 4,828 6,872 10,192 14,409 18,503 4,623 5,729 7,295 8,728 10,100 11,335 10.8 4,507 5,763 8,721 11,843 17,224 4,299 5,268 6,408 7,977 9,397 10,792 12.6 6,312 9,226 12,833 5,937 7,288 8,663 9,926 11,014 12,078 5.4 5,620 8,127 11,536 15,432 5,336 6,647 8,042 9,397 10,604 11,700 7.2 5,057 6,960 10,280 14,279 18,278 4,552 5,974 7,370 8,738 10,093 11,253 9.0 4,364 5,927 8,875 12,788 17,094 4,149 5,142 6,619 8,028 9,421 10,751 10.8 5,179 7,489 11,249 15,750 3,815 4,784 5,783 7,302 8,731 10,151 12.6 5,609 7,929 11,403 5,360 6,599 7,964 9,345 10,454 11,529 5.4 5,057 6,937 10,192 14,085 4,736 5,981 7,390 8,714 10,018 11,147 7.2 4,320 6,080 8,830 12,764 16,903 3,989 5,312 6,694 8,083 9,410 10,683 9.0 5,169 7,619 11,249 15,654 3,664 4,623 5,913 7,411 8,752 10,113 10.8 4,729 6,343 9,711 14,020 3,330 4,299 5,254 6,592 8,059 9,417 12.6 5,057 6,807 10,018 4,770 5,957 7,285 8,653 9,891 10,970 5.4 4,477 6,036 8,806 12,566 16,613 4,105 5,394 6,691 8,042 9,383 10,577 7.2 5,333 7,663 11,205 15,463 3,504 4,668 6,046 7,401 8,735 10,086 9.0 4,606 6,565 9,711 14,020 3,180 4,142 5,234 6,746 8,121 9,424 10.8 5,510 8,346 12,348 2,835 3,815 4,784 5,862 7,401 8,779 12.6 4,504 5,893 8,588 12,369 4,176 5,381 6,612 7,960 9,322 10,413 5.4 5,388 7,489 11,072 15,177 3,446 4,794 6,029 7,397 8,690 9,994 7.2 4,750 6,575 9,731 13,931 3,020 4,023 5,405 6,790 8,097 9,407 9.0 5,620 8,411 12,328 2,689 3,664 4,644 6,039 7,459 8,769 10.8 4,947 7,158 10,765 2,334 3,330 4,299 5,278 6,708 8,097 12.6 5,343 7,332 10,744 3,572 4,801 5,981 7,288 8,629 9,837 5.4 4,818 6,486 9,554 13,689 2,869 4,183 5,452 6,769 8,039 9,352 7.2 5,695 8,301 12,215 2,539 3,504 4,784 6,121 7,428 8,738 9.0 5,002 7,223 10,721 2,191 3,180 4,139 5,370 6,821 8,138 10.8 6,104 9,247 1,805 2,835 3,815 4,784 6,032 7,469 12.6 4,794 6,312 9,315 2,945 4,207 5,405 6,636 7,947 9,270 5.4 5,695 8,104 12,061 2,382 3,538 4,852 6,073 7,411 8,684 7.2 5,125 7,179 10,587 2,047 3,020 4,115 5,473 6,834 8,100 9.0 6,223 9,182 1,675 2,689 3,658 4,715 6,169 7,489 10.8 5,268 7,906 1,225 2,334 3,330 4,299 5,336 6,838 12.6 3,862 5,684 880 1,658 2,351 3,026 3,825 4,784

TABLE 6d FCX US/USPO 50 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) Page 12 of 20 SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 12,085 8,953 10,072 11,246 12,392 7.2 11,011 14,535 18,657 8,397 9,588 10,731 11,942 13,088 14,208 9.0 9,936 13,280 17,343 21,857 7,793 9,018 10,233 11,406 12,638 13,781 10.8 8,830 11,997 15,910 20,510 25,423 7,042 8,417 9,659 10,867 12,096 13,293 12.6 7,663 10,680 14,446 18,988 24,031 5,988 7,680 9,028 10,287 11,495 12,761 5.4 10,816 8,353 9,513 10,622 11,799 12,935 7.2 9,844 13,129 17,166 7,813 9,015 10,168 11,348 12,498 13,610 9.0 8,888 11,935 15,791 20,336 7,152 8,428 9,653 10,809 12,020 13,174 10.8 7,871 10,710 14,416 18,899 23,812 6,305 7,813 9,062 10,280 11,451 12,693 12.6 6,766 9,516 13,010 17,343 22,335 5,244 7,005 8,431 9,693 10,898 12,133 5.4 9,666 12,891 7,773 8,950 10,035 11,191 12,348 7.2 8,800 11,785 15,610 7,182 8,434 9,584 10,710 11,894 13,030 9.0 7,947 10,680 14,296 18,718 6,456 7,851 9,066 10,236 11,406 12,590 10.8 7,036 9,574 12,952 17,193 22,161 5,521 7,179 8,472 9,683 10,857 12,082 12.6 5,872 8,441 11,608 15,671 20,598 4,623 6,234 7,820 9,110 10,304 11,498 5.4 8,649 11,519 7,131 8,353 9,506 10,564 11,748 12,870 7.2 7,933 10,502 14,088 18,391 6,483 7,841 9,015 10,151 11,283 12,444 9.0 7,080 9,516 12,935 17,046 21,857 5,715 7,230 8,472 9,653 10,799 11,997 10.8 6,200 8,516 11,577 15,552 20,424 4,664 6,456 7,875 9,096 10,256 11,454 12.6 7,469 10,352 14,115 18,776 5,394 7,172 8,516 9,738 10,901 5.4 7,844 10,263 13,730 6,428 7,786 8,912 10,001 11,130 12,276 7.2 7,155 9,366 12,624 16,746 5,766 7,240 8,455 9,581 10,676 11,833 9.0 6,350 8,499 11,457 15,371 20,162 4,941 6,541 7,909 9,073 10,216 11,359 10.8 7,605 10,294 13,969 18,657 3,914 5,684 7,257 8,537 9,707 10,823 12.6 6,619 9,189 12,624 17,016 4,664 6,428 7,916 9,154 10,318 5.4 7,080 9,127 12,293 5,725 7,141 8,356 9,468 10,506 11,672 7.2 6,394 8,380 11,188 15,132 5,036 6,541 7,875 9,021 10,123 11,229 9.0 7,633 10,175 13,757 18,418 4,129 5,807 7,295 8,503 9,649 10,717 10.8 6,797 9,158 12,505 16,808 4,872 6,582 7,953 9,127 10,253 12.6 8,141 11,188 15,282 5,630 7,291 8,581 9,734 5.4 6,319 8,230 10,891 5,012 6,456 7,807 8,892 9,949 11,055 7.2 7,588 9,963 13,518 17,971 4,282 5,821 7,281 8,455 9,564 10,615 9.0 6,858 9,052 12,293 16,538 3,245 5,053 6,623 7,957 9,083 10,164 10.8 8,172 11,099 15,074 4,006 5,821 7,349 8,574 9,676 12.6 7,244 9,936 13,638 4,777 6,592 7,991 9,189 5.4 7,483 9,666 13,071 4,292 5,756 7,172 8,353 9,424 10,444 7.2 6,827 8,888 11,966 16,149 3,497 5,094 6,582 7,902 9,011 10,082 9.0 8,110 10,891 14,805 4,268 5,893 7,360 8,530 9,632 10.8 7,336 9,844 13,399 5,036 6,677 7,998 9,141 12.6 8,800 12,116 5,821 7,404 8,622 5.4 6,722 8,636 11,594 3,566 5,053 6,469 7,807 8,912 9,885 7.2 8,022 10,622 14,477 2,610 4,350 5,862 7,322 8,462 9,543 9.0 7,336 9,666 13,129 3,385 5,149 6,677 7,994 9,076 10.8 8,738 11,904 4,169 5,933 7,421 8,585 12.6 7,844 10,710 4,971 6,728 8,069

TABLE 6e FCX US/USPO 62 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) Page 13 of 20 SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 14,296 18,804 23,795 12,693 14,477 16,234 17,998 19,694 21,315 7.2 12,710 17,121 22,178 27,583 11,690 13,546 15,354 17,166 18,940 20,660 9.0 10,867 15,218 20,298 25,873 31,783 10,314 12,454 14,385 16,238 18,101 19,875 10.8 9,345 13,027 18,203 23,935 30,029 9,496 11,021 13,228 15,218 17,156 19,025 12.6 8,823 11,058 15,726 21,717 27,995 8,946 10,427 11,816 13,993 16,071 18,049 5.4 12,740 17,091 22,042 11,829 13,583 15,310 17,098 18,821 20,438 7.2 11,266 15,374 20,359 25,781 31,554 10,802 12,662 14,481 16,248 18,053 19,786 9.0 9,567 13,535 18,456 24,024 29,937 9,301 11,533 13,491 15,344 17,190 18,998 10.8 8,533 11,345 16,296 21,994 28,091 8,680 10,250 12,263 14,307 16,238 18,131 12.6 8,045 10,076 13,819 19,660 26,013 8,131 10,819 11,103 13,024 15,153 17,145 5.4 11,314 15,347 20,233 10,973 12,723 14,463 16,207 17,944 19,595 7.2 9,977 13,726 18,486 23,935 29,705 9,833 11,782 13,593 15,371 17,169 18,913 9.0 8,455 11,945 16,582 22,089 27,995 8,414 10,581 12,594 14,467 16,262 18,101 10.8 7,803 9,919 14,457 19,950 26,105 7,865 9,479 11,280 13,402 15,323 17,214 12.6 9,189 11,915 17,568 23,843 7,319 8,946 10,434 12,017 14,231 16,193 5.4 10,042 13,662 18,394 23,700 10,028 11,864 13,559 15,293 17,060 18,749 7.2 8,933 12,171 16,613 21,994 27,811 8,769 10,915 12,723 14,491 16,262 18,039 9.0 8,168 10,519 14,774 20,042 26,057 7,599 9,513 11,696 13,563 15,395 17,207 10.8 7,073 8,933 12,710 17,916 23,980 7,049 8,680 10,314 12,478 10,789 16,299 12.6 8,394 10,615 15,535 21,625 6,483 8,131 9,714 11,150 13,266 15,286 5.4 9,059 12,092 16,490 21,810 9,018 11,024 12,737 14,419 16,176 17,875 7.2 7,981 10,744 14,839 19,977 25,825 7,633 9,973 11,877 13,607 15,368 17,145 9.0 6,838 9,281 13,058 18,012 23,980 6,783 8,448 10,789 12,689 14,481 16,272 10.8 8,155 11,092 15,917 21,810 6,234 7,865 10,567 11,529 13,518 15,371 12.6 9,598 13,566 19,407 5,667 7,319 8,929 10,427 12,300 14,385 5.4 8,168 10,697 14,678 19,790 8,008 10,100 11,887 13,583 15,269 17,002 7.2 6,995 9,554 13,088 17,947 23,795 6,534 8,929 11,017 12,757 14,474 16,227 9.0 8,250 11,475 16,043 21,810 5,968 7,599 9,796 11,826 13,607 14,481 10.8 7,425 9,629 14,013 19,599 5,401 7,049 8,663 10,536 12,628 14,481 12.6 8,759 11,727 17,251 4,825 6,483 8,114 10,813 11,301 13,447 5.4 7,251 9,554 12,931 17,756 23,427 6,960 9,086 11,065 12,751 14,392 16,122 7.2 8,598 11,533 16,013 21,673 5,811 7,848 10,100 11,922 13,624 15,303 9.0 7,251 10,106 14,170 19,599 5,152 6,783 8,663 10,929 12,778 14,498 10.8 8,581 12,266 17,439 4,575 6,234 7,848 9,550 11,744 13,624 12.6 8,011 10,171 15,153 3,968 5,667 7,298 8,929 10,475 12,536 5.4 8,663 11,376 15,757 21,349 5,862 8,076 10,134 11,904 13,556 15,207 7.2 7,663 10,202 14,109 19,442 4,889 6,677 9,069 11,089 12,802 14,467 9.0 8,963 12,457 17,439 4,326 5,968 7,616 10,011 11,932 13,648 10.8 7,773 10,710 15,374 3,736 5,401 7,042 8,663 10,809 12,744 12.6 9,154 13,184 3,074 4,825 6,483 8,114 9,724 11,594 5.4 7,773 10,089 13,866 19,155 4,668 7,049 9,141 11,092 12,744 14,344 7.2 9,154 12,392 17,278 4,060 5,695 8,008 10,205 11,976 13,617 9.0 7,998 10,932 15,374 3,487 5,145 6,766 8,912 11,072 12,809 10.8 9,376 13,440 2,958 4,575 6,223 7,848 9,751 11,884 12.6 8,363 11,410 2,092 3,968 5,667 7,298 8,929 10,622

TABLE 6f FCX US/USPO 82 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 17,766 23,427 15,003 17,033 19,121 21,134 23,069 24,938 7.2 15,821 21,291 27,569 34,349 13,853 15,995 18,090 20,189 22,253 24,194 9.0 13,726 18,984 25,266 32,233 39,569 12,396 14,798 17,012 19,124 21,270 23,307 10.8 11,290 16,419 22,659 29,807 37,331 10,721 13,215 15,716 17,971 20,168 22,345 12.6 10,458 13,426 19,837 27,020 34,905 10,048 11,829 14,085 16,688 19,015 21,233 5.4 15,821 21,250 13,986 16,033 18,046 20,121 22,059 23,990 7.2 14,068 19,111 25,310 32,110 12,802 14,989 17,036 19,141 21,243 23,232 9.0 12,123 16,889 22,915 29,872 37,269 11,144 13,744 15,958 18,077 20,220 22,311 10.8 10,222 14,453 20,353 27,316 34,905 9,755 11,949 14,655 16,947 19,094 21,281 12.6 9,557 12,017 17,531 24,454 32,295 9,107 10,987 12,887 15,596 17,927 20,179 5.4 14,068 19,070 25,181 12,969 15,006 17,026 19,083 21,079 22,997 7.2 12,488 17,060 22,935 29,746 11,683 13,972 16,030 18,053 20,192 22,229 9.0 10,779 14,965 23,577 27,446 34,843 9,779 12,648 14,934 17,060 19,165 21,277 10.8 9,301 12,659 18,128 24,795 32,421 8,813 10,785 13,529 15,890 18,067 20,250 12.6 8,660 10,905 15,306 21,932 29,684 8,165 10,048 11,874 14,470 16,876 19,124 5.4 12,549 16,975 22,830 11,864 14,027 16,030 18,019 20,059 21,997 7.2 11,205 15,136 20,608 27,361 34,594 10,451 12,945 15,044 17,063 19,114 21,192 9.0 10,198 13,215 18,343 24,880 32,356 8,568 11,457 13,887 16,030 18,087 20,243 10.8 8,404 11,034 15,992 22,233 29,807 7,871 9,755 12,358 14,832 17,022 19,162 12.6 9,987 13,256 19,496 26,934 7,223 9,107 10,966 13,297 15,808 18,039 5.4 11,331 15,009 20,438 10,676 13,034 15,023 16,982 19,008 20,960 7.2 10,028 13,406 18,384 24,795 32,110 9,171 11,840 14,030 16,060 18,046 20,158 9.0 8,213 11,717 16,248 22,318 29,746 7,605 10,137 12,839 15,006 17,084 19,148 10.8 9,837 14,027 19,796 27,020 6,933 8,813 11,034 13,781 15,978 18,118 12.6 9,090 11,591 17,101 24,113 6,258 8,165 10,048 12,038 14,713 16,999 5.4 10,198 13,320 18,172 24,539 9,465 11,928 14,051 16,026 17,954 19,957 7.2 8,810 11,952 16,248 22,233 29,497 7,807 10,628 13,034 15,067 17,077 19,090 9.0 10,458 14,324 19,923 27,020 6,664 8,724 11,707 14,020 16,091 18,125 10.8 8,834 12,314 17,487 24,283 5,991 7,871 9,823 12,672 14,968 17,101 12.6 10,434 14,924 21,461 5,316 7,223 9,107 11,011 13,631 15,965 5.4 9,045 11,932 16,033 21,977 8,233 10,741 13,082 15,009 16,961 18,923 7.2 10,779 14,368 19,796 26,849 6,415 9,352 11,973 14,092 16,091 18,022 9.0 9,195 12,659 17,572 24,239 5,722 7,605 10,427 13,003 15,095 17,101 10.8 10,819 15,351 21,632 5,043 6,933 8,813 11,437 13,965 16,071 12.6 9,516 12,955 18,899 4,330 6,271 8,165 10,048 12,409 14,921 5.4 10,819 14,133 19,496 6,978 9,554 11,997 14,054 15,995 17,879 7.2 9,581 12,720 17,487 24,027 5,439 8,052 10,765 13,126 15,095 17,033 9.0 11,290 15,477 21,547 4,773 6,664 9,062 11,928 14,129 16,125 10.8 9,496 13,471 19,070 4,077 5,991 7,871 10,048 12,908 15,095 12.6 11,246 16,504 3,313 5,316 7,223 9,107 11,167 13,866 5.4 9,687 12,573 17,166 23,642 5,609 8,332 10,809 13,109 15,003 16,886 7.2 11,440 15,351 21,376 4,490 6,595 9,509 12,085 14,156 16,064 9.0 10,093 13,641 19,025 3,815 5,722 7,670 10,652 13,133 15,132 10.8 11,846 16,760 3,078 5,043 6,933 8,858 11,758 14,088 12.6 10,028 14,409 2,197 4,337 6,271 8,165 10,048 12,778 Page 14 of 20

TABLE 6g FCX US 102 COOLING CAPACITY EXPANDED RATINGS Entering Water Temp ( o F) 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 TOTAL COOLING CAPACITY (Btu/Hr) Page 15 of 20 SENSIBLE COOLING CAPACITY (Btu/Hr) Wet bulb air temperature ( o F) Dry bulb air temperature ( o F) T 59.0 62.6 66.2 69.8 73.4 69.82 73.43 77.0 80.6 84.2 87.8 5.4 22,161 16,480 18,800 21,028 23,243 7.2 19,947 26,641 34,349 15,398 17,684 19,981 22,338 24,560 26,730 9.0 17,582 24,031 31,701 40,221 14,013 16,500 18,848 21,189 23,580 25,873 10.8 15,023 21,226 28,756 37,430 46,594 12,078 15,074 17,613 20,028 22,417 24,809 12.6 12,314 18,172 25,655 34,205 43,728 10,437 13,061 16,163 18,742 21,192 23,669 5.4 19,796 15,402 17,633 19,858 22,096 7.2 17,729 23,983 31,558 14,266 16,558 18,814 21,117 23,430 25,580 9.0 15,613 21,472 28,855 37,286 12,819 15,354 17,691 20,042 22,383 24,720 10.8 13,201 18,814 25,900 34,349 43,657 10,506 13,880 16,432 18,841 21,195 23,628 12.6 11,133 15,859 22,850 31,117 40,651 9,417 11,662 14,907 17,548 20,025 22,465 5.4 17,582 23,734 14,317 16,494 18,718 20,919 23,150 7.2 15,736 21,421 28,705 13,099 15,460 17,701 19,970 22,263 24,467 9.0 13,842 19,059 25,999 34,277 43,370 11,386 14,208 16,562 18,868 21,189 23,539 10.8 11,529 16,599 23,195 31,216 40,579 9,189 12,553 15,293 17,695 20,059 22,454 12.6 10,076 13,744 20,192 28,067 37,430 8,424 10,461 13,614 16,391 18,834 21,247 5.4 15,589 21,175 13,119 15,415 17,609 19,766 21,987 24,167 7.2 14,064 19,008 25,802 33,990 11,758 14,368 16,599 18,817 21,100 23,318 9.0 12,314 16,845 23,243 31,117 40,292 9,905 13,013 15,453 17,742 20,001 22,362 10.8 9,905 14,579 20,585 28,166 37,286 8,148 11,014 14,139 16,582 18,902 21,226 12.6 11,969 17,729 25,112 33,990 7,407 9,417 12,126 15,207 17,725 20,107 5.4 14,037 18,715 25,409 11,826 14,361 16,480 18,657 20,820 23,024 7.2 12,635 16,845 23,045 30,923 10,390 13,235 15,528 17,715 19,861 22,171 9.0 10,789 14,948 20,585 28,067 37,071 8,284 11,662 14,368 16,637 18,892 21,161 10.8 12,908 18,125 25,211 33,919 7,145 9,397 12,887 15,463 17,766 20,073 12.6 10,642 15,514 22,260 30,725 6,415 8,424 10,645 13,986 16,555 18,920 5.4 12,659 16,548 22,652 10,506 13,187 15,422 17,589 19,660 21,881 7.2 11,185 14,972 20,438 27,770 8,980 11,894 14,436 16,613 18,776 20,987 9.0 13,348 18,223 25,112 33,704 6,865 10,229 13,198 15,545 17,759 19,984 10.8 11,280 15,958 22,355 30,626 6,138 8,148 11,430 14,351 16,654 18,930 12.6 13,498 19,551 27,477 5,384 7,421 9,444 12,669 15,450 17,790 5.4 11,256 14,777 19,994 9,165 11,894 14,385 16,459 18,548 20,707 7.2 13,498 18,026 24,819 33,277 7,479 10,553 13,327 15,548 17,698 19,810 9.0 11,874 16,081 22,260 30,333 5,858 8,680 11,894 14,494 16,685 18,855 10.8 14,088 19,697 27,378 5,115 7,145 9,861 13,160 15,596 17,814 12.6 11,775 17,138 24,324 4,350 6,415 8,424 11,062 14,279 16,702 5.4 13,399 17,582 24,229 7,800 10,577 13,235 15,426 17,541 19,527 7.2 12,068 15,958 21,915 29,889 5,742 9,165 12,010 14,508 16,627 18,711 9.0 14,310 19,602 27,081 4,845 6,971 10,461 13,375 15,610 17,770 10.8 12,512 17,336 24,229 4,094 6,138 8,240 11,778 14,498 16,729 12.6 14,972 21,373 3,272 5,391 7,431 9,557 13,044 15,579 5.4 12,020 15,589 21,373 6,391 9,257 11,939 14,423 16,415 18,442 7.2 14,283 19,257 26,689 4,565 7,687 10,669 13,419 15,576 17,654 9.0 12,833 17,237 23,983 3,828 5,858 8,980 12,078 14,586 16,709 10.8 15,269 21,322 3,037 5,115 7,145 10,277 13,344 15,675 12.6 13,177 18,715 2,088 4,357 6,415 8,424 11,570 14,481

Page 16 of 20

Page 17 of 20

Physical Size (in.) & Data A B C Weight (lbs) Connec on (FPT) 22 19.2 29.5 8.7 33.1 1/2 32 19.2 38.6 8.7 44.1 1/2 42 19.2 47.2 8.7 52.9 3/4 50 19.2 47.2 8.7 52.9 3/4 62 23.2 52.0 8.7 75.0 3/4 82 23.2 52.0 8.7 75.0 3/4 102 23.2 52.0 8.7 75.0 3/4 FCX US DIMENSIONS WITHOUT CABINET FCX 22, 32, 42 & 50 FCX 62, 82 & 102 Page 18 of 20

FCX 22, 32, 42 & 50 FCX 62 & 82 A B C Weight Connec on (lbs) (FPT) 22 22.6 20.6 17.3 30.9 1/2 32 31.7 29.7 26.4 41.9 3/4 42 40.3 38.3 35.1 50.7 3/4 50 40.3 38.3 35.1 50.7 3/4 62 45.6 44.2 43.4 75.0 3/4 82 45.6 44.2 43.4 75.0 3/4 Page 19 of 20

Phoenix Energy Supply 7523 County House Road Auburn, New York 13021 Page 20 of 20 (315) 253 3720 info@phoenixenergysupply.com www.phoenixenergysupply.com