Hinge Wing Safety Interlock Switches

Similar documents
Hinge Wing Safety Interlock Switches

Hinge Wing Safety Interlock Switches

EZ-LIGHT 2-Color Indicators for Use with Sensors

WLA General Purpose LED Light - PWM Dimmable

WLS28 Work Light Strip

WLS28-2 LED Strip Light

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

EZ-LIGHT Indicators 4-Color, Multi-Function

WLS28-2 LED Strip Light

WLS28-2 LED Strip Light

WLS28 Work Light Strip

Safety Interlock Switches

CONTROLLERS & MODULES EMERGENCY STOP & STOP CONTROL SAFETY LIGHT SCREENS

Sense7-series Non-contact coded safety switch

SUNTURA SOLAR TRACKER

SUNTURA HD SOLAR TRACKER

Users Guide for Ac-sync

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

37SCENE 46SCENE 79SCENE

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

The Da-Lite Difference.

Do not install and/or operate this safety product unless you have read and understand the safety information contained

Installation and Operation Instructions Safety Director Arrow

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

CD Couplings SERIES A1C. MTY (81) MEX (55) QRO (442) DIST.

Easytork Solenoid Valve IOM

A2P Single Phase Automatic Industrial Battery Charger

MKey9-series Safety Interlock Switch with Guard Locking

A S S E M B L Y I N S T R U C T I O N S

Please read and understand instructions before attempting installation. HDHWF (e/h)

II DISTRIBUTION & SUBSTATION TYPE C

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

EStrong-series Emergency Stop

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

AD-7. Instruction Manual. Thermal Indicating Ammeter HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Installation / Operation Instructions Sunnex ORION Series Exam Lights

WARNING. Laser light is extremely bright and can potentially cause permanent eye damage or interfere with critical operations if improperly used.

The Da-Lite Difference.

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

TL30 Basic Tower Light

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Advanced Test Equipment Rentals ATEC (2832)

User's Manual. Earth Ground Resistance Tester. Model Introduction

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

SPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

CRD610 Automatic Fitting Inserter

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

Power Float Manifold. Installation and Operations Manual Module 11A

Type Flexair Pneumatic Pressure Control Valves

CRD400 Fitting Inserter OPERATIONS MANUAL

Heavy Duty Industrial Foot Switches

CCP2-FLR1-21_ flange-rod operating mechanism

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

LINEAR MOTION CONTROL

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

INW Panel Meter Reading an INW PT12 Sensor

Guardian HH Shaft Coupling

this manual Covers all units shipped 2015 to date

The Da-Lite Difference.

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Guardian FH Flywheel Coupling

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CRD600 Automatic Fitting Inserter

Heavy Duty Commercial Linear Gate Operator

Pontoon and Tri-Toon Bunk Assembly Instructions

Guardian Taper Grid Shaft Coupling

FMC-1/2 Tina Muting unit

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

Smile 41 Push-button box with/without emergency stop

Owner s Manual & Safety Instructions

Safety Assembly Operation Service and Adjustment Repair Parts 1602 CORPORATE DRIVE, WARRENSBURG MISSOURI PHONE FAX

3-Pt. Quick Hitch. Owner s Manual

DAP-625S and DAP-875S

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Owner s Guide. Dumbwaiter. Series DUMBWAITER OWNER S GUIDE 1

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

3700/8700/8800 Rim Exit Device Owner s Manual

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

SCHMIDT COUPLINGS OPERATIONAL BENEFITS

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Level One Electric Vehicle Charging Station Wall Mount Product Guide

CAMBELT TENSION GAUGE

Washington, DC U.S.A. SC-M150-00X Axial Flux, Permanent Magnet, DC Brushless Electric Motor Operating Manual Version 1.00

Adjustable Steel Welding Table

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

D4BS CSM_D4BS_DS_E_8_4

Electric Actuator Installation, Operation & Maintenance Manual

16K and 19K Sidewinder TM Service Kit Instructions 86005

NHP SAFETY REFERENCE GUIDE

Transcription:

SI-HG80 Series Safety Interlock Switches encapsulated in a load-bearing hinge Safety switch is integrated and encapsulated into a load-bearing hinge, providing a high degree of protection from intentional defeat Identical in appearance to non-switching blank hinge (see Accessories on page 6) Switch components concealed inside the hinge are protected from mechanical impact, providing superior performance to actuator-activated safety switches; rated IEC IP67 Hinge operates to a full 80 range of motion; safety switching point (guard-closed position) is adjustable over the full 0 80 operating range Hinge can support an axial load of 750 N and more than,000 N in radial direction When properly interfaced or used with an appropriate controller, two SI-HG80D.. switches can achieve safety category 4, per ISO 3849 (EN 954-) Robust zinc die-cast housing is corrosion resistant Typical applications include: Hinged covers and guards to machines Hinged doors and gates in safety fencing systems Modular aluminum framing Inline QD Fitting Right-angle QD Fitting Model QD Connection Contact Configuration (Closed State) Contact Configuration (Open State) Switching Diagram SI-HG80DQD Inline QD Fitting -2 0 3 SI-HG80DQDR Right-angle QD Fitting 4 3 2 4 3 2 3 0 Safety Operating Angle Note: Terminal #3 is non-safety. Switching Diagram Key Contacts: Open Closed Transition Important Information Regarding the Use of Safety Switches In the United States, the functions that Banner safety switches are intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are applied, installed, wired, operated, and maintained. Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This information is found in the instruction manual packaged with each safety switch. In addition, we suggest that any questions regarding the use or installation of safety switches be directed to the factory applications department at the telephone numbers or address shown below.

Banner Engineering Corp. recommends that safety switches be applied according to the guidelines set forth in international (ISO/IEC) standards listed below. Specifically, Banner Engineering Corp. recommends application of these safety switches in a configuration which meets safety category 4, per ISO 3849 (EN954-). In addition, the user of Banner safety switches has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of Banner safety switches in any particular application are satisfied. Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed. Application Assistance Toll Free: -888-3-SENSOR (-888-373-6767) 974 Tenth Avenue North Minneapolis, MN 5544 Hinge Wing Safety Interlock Switches U.S. Regulations Applicable to Use of Banner Safety Switches OSHA Code of Federal Regulations: Title 29, Parts 900 to 90 Available from: Superintendent of Documents, Government Printing Office, P.O. Box 37954, Pittsburgh, PA 5250-7954, Tel: 202-52-800 U.S. Standards Applicable to Use of Banner Safety Switches ANSI B Standards for Machine Tools Safety Contact: Safety Director, AMT The Association for Manufacturing Technology, 790 Westpark Drive, McLean, VA 2202, Tel.: 703-893-2900 Applicable European and International Standards ISO/TR 200- (EN 292- & -2) Safety of Machinery Basic Concepts, General Principles for Design ISO 3852 (EN 294) Safety of Machinery Safety Distances to Prevent Danger Zones Being Reached by the Upper Limbs ISO 3853 (EN 8) Safety of Machinery Safety Distances to Prevent Danger Zones Being Reached by the Lower Limbs ISO 3849- (EN 954-) Safety-Related Parts of Control Systems ISO 3855 (EN 999) The Positioning of Protective Equipment in Respect to Approach Speeds of Parts of the Human Body ISO 49 (EN 088) Interlocking Devices Associated with Guards Principles for Design and Selection IEC 60204- Electrical Equipment of Machines Part : General Requirements IEC 60947-5- Low Voltage Switchgear Electromechanical Control Circuit Devices Contact: Global Engineering Documents, 5 Inverness Way East, Englewood, CO 802-5704, Tel.: 800-854- 779 Mechanical Installation WARNING: Hazard Point It must not be possible for personnel to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. Please reference OSHA CFR 90.27 and ANSI B standards for information on determining safety distances and safe opening sizes for your guarding devices. All mounting hardware is supplied by the user. Fasteners must be of sufficient strength to guard against breakage. Use of permanent fasteners or locking hardware is recommended to prevent loosening or displacement of the actuator and the switch body. The mounting holes in the switch body and the actuator accept M6 screws (see Dimensions on page 5). Ensure that excessive force is not exerted by the weight and swing of the guard, gate, or door (see Specifications on page 5). Position blank hinges (if used) and the hinge switch(es) on the guard or gate while it is in its fully closed and latched position. Verify that the axis of rotation is identical for all hinges used. (Typically, this can be accomplished by using a straight edge along the long flat edge to ensure the switch bodies are parallel.) After the mounting hardware is secure, check the rotation of the guard or gate for misalignment and binding. NOTE: A safety switch must be installed in a manner that discourages tampering or defeat.

CAUTION: End Stops. Do not use the switch as an end stop. The operating angle of the switch must be limited by outer end stops. Setting the Switch Point CAUTION: Remove Set Screw Head. Shear off the hexagonal head of the set screw after it is set, and before using the switch. If not, the safe activation of the switch can not be ensured. Figure. Hinge switch with set screw head in place. Ensure the hinge switches (and blind hinges, if used) are properly mounted and the guard or gate swings freely throughout its range of motion without binding. If binding is noticed, repeat the mechanical installation procedures. 2. Place the guard in its closed and latched position. After the switch point is set, it cannot be changed. Before proceeding, verify the installation is correct and the resulting switching action is what is expected. 3. Tighten the hexagonal set screw head with a 3 mm open-ended wrench (rotate clockwise when switch is mounted vertically and the nut is on top). See Figure. Hinge switch with set screw head in place on page 3. 4. Continue tightening until the set screw head shears completely off the switch. When the screw head shears off, the switch point is set. Electrical Installation CAUTION: Electrical Installation Two safety switches must be used for each interlock guard to achieve control reliability or Safety Category 4 (per ISO 3849-, EN 954-) of a machine stop circuit. Use of only one safety switch per interlock guard is not recommended. In addition, normally-closed safety contacts from each of the two safety switches should be connected to the two separate inputs of a 2-channel safety module or safety interface. This is required to provide monitoring for safety switch contact failure, and to provide the necessary reset routine, as required by IEC 60204- and NFPA 79 machine safety standards.

WARNING: Series Connection of Safety Interlock Switches Monitoring multiple guards with a series connection of safety interlock switches may result in a failure being masked or not detected at all. When such a configuration is used, periodic checks must be performed regularly to verify proper operation. All failures must be immediately corrected ( e.g. immediately replacing a failed switch), or the loss of the safety stop signal or an inappropriate reset could lead to serious injury or death. As shown, a normally-closed safety contact (i.e., a safety contact that is closed when the actuator is engaged) from each of two safety switches per interlock guard must connect to a 2-channel safety module or safety interface to achieve a control reliable interface to the master stop control elements of a machine. Examples of appropriate safety modules include 2-channel emergency stop (E-stop) safety modules and gate monitor safety modules. Two functions of the safety module or safety interface are to:. provide a means of monitoring the contacts of both safety switches for contact failure, and to prevent the machine from restarting if either switch fails; and 2. provide a reset routine after closing the guard and returning the safety switch contacts to their closed position. This prevents the controlled machinery from restarting by simply closing the guard. This necessary reset function is required by ANSI B and NFPA 79 machine safety standards. Use only the positively driven, normally closed safety contact (between pins and 2) from each switch for connection to the safety module. A typical use is to communicate with a process controller. Refer to the installation instructions provided with the safety modules for more information regarding the interface of the safety module to the machine stop control elements. Periodic Checks Safety Switch # 2 Input Channel # 2-channel Safety Module (2-channel E-stop Module 2-channel Gate Monitor Module, etc.) Safety Switch #2 2 Input Channel #2 Single gate or guard Figure 2. Hinge Wiring to Safety Module Connect two redundant safety switches per interlock guard to an appropriate 2-channel input safety module. Refer to the installation instructions provided with the safety module for information regarding the interface of the safety module to the machine stop control elements. A designated person should perform the following safety switch checks at each shift change or machine setup. A designated person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure.. Check the switch body for damaged or broken parts. 2. Confirm the safety switch is not being used as an end stop. 3. Verify it is not possible to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. 4. Verify the hinge swings freely throughout its total operating range. 5. Tighten any loosened mounting hardware. 6. Check for signs of deterioration or damage. 7. Check for signs of tampering or defeat to the switch or to the wiring interface to the machine. Repairs Do not attempt any repairs to the Module. It contains no field-replaceable components. Return it to the factory for warranty repair or replacement by contacting Banner Factory Application Engineering. They will attempt to troubleshoot the system from your description of the problem. If they conclude a component is defective, they will issue a return merchandise authorization (RMA) number for your paperwork and give you the proper shipping address. Pack the Module carefully. Damage that occurs in return shipping is not covered by warranty.

CAUTION: Abuse of Module After Failure If an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt to correct the fault by a physical impact to the housing. An internal relay may have failed in such a manner that its replacement is required. If the Module is not immediately replaced or repaired, multiple simultaneous failures may accumulate such that the safety function can not be guaranteed. Specifications Contact Rating 3A @ 250V ac max., 0.5 A @ 60V dc max. 2.5 kv max. transient tolerance NEMA A300 P300 European Rating Utilization categories: AC5 and DC3 (IEC 90497-5-) Ui = 250V ac Ith = 3A Short Circuit Protection 6 amp Slow Blow, 0 amp Fast Blow. Recommended external fusing or overload protection. Wire Connections 4-pin Micro-style quick-disconnect (QD) fitting. Cables are ordered separately; see Accessories. Weight 0.40 kg (0.88 lb) Minimum Switching Speed 20 operations per minute Mechanical Life million operations Force Exerted by Guard per Switch Axial: 750 N (65 lbf) max. Radial: 000 N (220 lbf) max. Operating Range 0 to 80 Construction Zinc Die-cast (GD-Zn) Environmental Rating NEMA 4, IEC IP67 Operating Conditions Temperature: -25 to +70 C (-3 to +58 F) Application Notes: To avoid excessive radial stress in applications containing large doors, the hinge switch should be mounted either in pairs of two, or in conjunction with a blank hinge (see page 7). Certifications: Dimensions Model SI-HG80DQD Model SI-HG80DQDR 72.0 mm (2.83").0 mm (0.43") 5.0 mm (0.59") 6.0 mm (.63") 0.0 mm (0.39") 80.0 mm (3.5") 64.0 mm (2.52") 4x 6.5 mm (0.25") 2 x 0.5 mm (0.4") R9.0 mm 5.5 mm 2.0 mm (0.83").5 mm (0.45") 7.0 mm (0.67") 9.0 mm (0.75") 0.0 mm (0.39") 4.5 mm (0.8") M2 x 5.5 mm (0.6) 9.0 mm (0.75") 23.6 mm (0.93") 0.0 mm (0.39") M2 x Note: 8 mm Hole Recommended

Accessories 4-Pin Micro-Style Cordsets Model Length Style Dimensions Pinout MQEAC-406 MQEAC-45 MQEAC-430 MQEAC-406RA MQEAC-45RA.83 m (6 ft) 4.57 m (5 ft) 9.4 m (30 ft).83 m (6 ft) 4.57 m (5 ft) Straight 42 mm Typ. (.65") 32 mm Typ. (.26") ø4.5 mm (0.57") M2 x 3 2 = Red/Black 2 = Red/White 3 = Red 4 = Green 4 MQEAC-430RA 9.4 m (30 ft) Right-Angle 28 mm Typ. (.") M2 x ø 4.5 mm (0.57") Blank Hinge Model Description Dimensions SI-HG80A Same mechanical specifications as SI-HG80 Series Hinge Switches.0 mm (0.43") 5.0 mm (0.59") 72.0 mm (2.83") 6.0 mm (.63") 0.0 mm (0.39") 80.0 mm (3.5") 64.0 mm (2.52") 4x 6.5 mm (0.25") 2 x 0.5 mm (0.4") 0.0 mm (0.39") R9.0 mm 5.5 mm 9.0 mm (0.75") 4.5 mm (0.8") Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN- CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPEN- SES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR- RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.