Hinged Safety Door Switch

Similar documents
D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Manual Reset Limit Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Safety-door Switch. Ordering Information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Safety Limit Switch

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4NH CSM_D4NH_DS_E_7_1

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4NS. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Safety-door Switch. Model Number Structure

D4BS CSM_D4BS_DS_E_8_4

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Model Number Structure

Safety Limit Switch

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

2NC (slow-action) Direct. Model. opening

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Inductive Proximity Sensor

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4GS-N CSM_D4GS-N_DS_E_7_2

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

D4BL. Guard Lock Safety-door Switch

CSM_D4N-_R_DS_E_6_1

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Small Limit Switch D4V

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

2NC (slow-action) Direct. Model. opening

D4NL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key \ Lead-free, Environment-friendly Design

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Solenoid Locking Switches

Multiple Limit Switch

Switching Power Supply

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

HS6B Series Subminiature Interlock Switch

Door Interlock Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Switches & Operator Controls

Subminiature Basic Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

A22NK. Key-type Selector Switches

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

F3S-TGR-KM15/-KM16/-KH16

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

D4BL. Guard Lock Safety-door Switch

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

ED SERIES SAFETY LIMIT SWITCH Description

Miniaturized limit switches

ED SERIES SAFETY LIMIT SWITCH

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

HS1C Interlock Switches with Solenoid

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

Cylindrical Proximity Sensor

Compact plastic limit switches with positive opening mechanism

HS5D Miniature Interlock Switches

Door Interlock Switches

Inductive Proximity Sensor

Multiple Plunger Limit Switch

HS5D Miniature Interlock Switches

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Model Number Structure

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Position switches FR series

Compact plastic limit switches with positive opening mechanism

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

DL (AZD1) Mini Limit Switches

SG-B1 SERIES / SG-A1 SERIES

Model Number Structure

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Transcription:

Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ), left (180 ), or center (90 left or right) rotation. The head can be mounted in four directions. Double-insulation structure requires no grounding terminals. (with mark) 1- and 2-conduit models are available. Wide standard operating temperature range: 30 C to 70 C Safety Standards Conformity: Machinery Directive, Low-voltage Directive, EN50047, EN1088 Approval: Agency Standard File No. TÜV Rheinland EN60947-5-1 R9650736 BIA EN60947-5-1, 9610569 GS-ET-15 UL (see note) UL508, CSA C22.2 E76675 No.14 SUVA SUVA 6123 Note: Approval for CSA C22.2 No. 14 is authorized by mark. Ordering Information Model Number Legend - 1 2 3 c c 1. Conduit Size 1: Pg13.5 (1-conduit) 2: G 1 / 2 (1-conduit) 3: 1 / 2-14NPT (1-conduit) 5: Pg13.5 (2-conduit) 6: G 1 / 2 (2-conduit) 2. Built-in Switch 5: 1NC/1NO (Slow-action) A: 2NC (Slow-action) 3. Actuator AS: Shaft BC: Arm lever (mounted upward in the center position) 1

Actuator cuao Conduit size 1NC/1NO (see note) 2NC (see note) Model Shaft 1-conduit Pg13.5-15AS -1AAS G 1 / 2-25AS -2AAS 1 / 2-14NPT -35AS -3AAS 2-conduit Pg13.5-55AS -5AAS G 1 / 2-65AS -6AAS Arm lever ee 1-conduit Pg13.5-15BC -1ABC G 1 / 2-25BC -2ABC 1 / 2-14NPT -35BC -3ABC Model Note: 2-conduit Pg13.5-55BC -5ABC G 1 / 2-65BC -6ABC All models have slow-action contacts with approved positive opening mechanisms on NC contacts only. Specifications Approved Standard Ratings TÜV (EN60947-5-1) Utilization category Rated operating current (I e ) Rated operating voltage (U e ) AC-15 2 A 400 V Note: Use a 10-A fuse type gi or gg as a short-circuit protective device that conforms to IEC269. UL (UL508/CSA C22.2 No. 14) A600 Rated voltage Carry current Current (A) Voltage (VA) Make Break Make Break 120 VAC 10A 60 6 7,200 720 240 VAC 30 3 480 VAC 15 1.5 600 VAC 12 1.2 2

Characteristics Enclosure rating (see note 1) Life expectancy (see note 2) Operating speed Contact gap Operating frequency Positive opening force (see note 3) Positive opening travel (see note 3) Insulation resistance Contact resistance IP65 (EN60947-5-1) Mechanical:1,000,000 times min. Electrical: 150,000 times min. 2 /sec to 360 /sec 2 x 2.0 mm min. 30 operations/minute max. 1 N m {10.2 kgf cm} min. 45 min. 100 MΩ min. (at 500 VDC) between terminals of same or different polarity and between each terminal and non-current-carrying metal part. 25 mω max. (initial value) Rated impulse voltage (Uimp) Between terminals of same polarity: Uimp 4 kv (EN60947-5-1) Between terminals of different polarity: Uimp 4 kv (EN60947-5-1) Between each terminal and non-current-carrying metal part: Uimp 4 kv (EN60947-5-1) Rated insulation voltage (U i ) Conditional short-circuit current Switching overvoltage Pollution degree (operating environment) Conventional enclosed thermal current (I the ) Protection against electric shock Vibration resistance 400 V (EN60947-5-1) 100 A (EN60947-5-1) 1,500 V max. (EN60947-5-1) 3 (EN60947-5-1) 10 A (EN60947-5-1) Class II (double insulation) Malfunction:10 to 55 Hz, 0.75 mm single amplitude Shock resistance Mechanical: 1,000 m/s 2 {approx. 100G} min. Malfunction: 300 m/s 2 {approx. 30G} min. Ambient temperature Ambient humidity Weight Material Note: Body and actuator flange Actuator Operating: 30 C to 70 C (with no icing) Operating: 95% max. -15AS: Approx. 74 g -15BC: Approx. 84 g Glass-fiber reinforced thermoplast, self-extinguishing Stainless steel 1. Although the switch box is protected from dust or water penetration, do not use the in places where metal dust, water, or chemical may be sprayed onto the head, otherwise Switch damage or malfunctioning may occur. 2. The above mechanical or electrical life is ensured at an ambient temperature of 5 C to 35 C and an ambient humidity of 40% to 70%. 3. Be sure that the applied positive opening force and stroke are in conformity with the specified ranges. 3

Nomenclature - BC Guard Closed Guard Open Cam Forced separation of NC contacts When opening the guard When the guard is opened, the cam that is directly coupled to the shaft rotates to press the Switch in the direction shown by the arrow. This action separates the contacts to stop the machine. Arm Lever The arm lever is mounted upwards in the center position before shipping. To change the position, loosen the arm lever mounting screw, dismount the arm lever, and mount the arm lever in the left or right position. The joint between the shaft and arm lever is formed with form-lock construction which remains secure even when the screw becomes loose. Arm lever and shaft are made of stainless steel. Built-in Switch The built-in switch has a positive opening mechanism that forcibly separates the NC contact. Models with a 1NC contact and 1NO contact or 2NC contacts are available. Cover The cover, with a hinge on its lower part, can be opened by removing the screw of the cover, which ensures ease of maintenance and wiring. * The housing and head of the are made of resin. Use D4BS Miniature Electromagnetic Lock Safety Door Limit Switches for applications requiring safety door switches of tough, high-sealing, or oil-resistant construction. Head The head can be mounted in four directions. Conduit A wide variety of conduits is available. Size 1-conduit 2-conduit Pg13.5 Yes Yes G 1 / 2 Yes Yes 1 / 2-14NPT Yes --- 4

Operation Contacts Model Contact Contact form Diagram Remarks - 5 1NC/1NO Closed (7 ) Travel (19 ) Open ON Only NC contacts 11 and 12 have a positive opening mechanism. The minimum positive opening travel is 45. They can be used as opposing poles. - A 2NC Closed (7 ) Travel Open ON NC contacts 11, 12, 21, and 22 have a positive opening mechanism. The minimum positive opening travel is 45. They can be used as opposing poles. Note: Terminals are numbered according to EN50013. Contact forms are according to EN60947-5-1. Positive Opening Mechanism 1NC/1NO Contact (Slow-action) 2NC Contact (Slow-action) Fixed contact on NC side Contact spring Reset spring Fixed contact on NC side Movable contact Fixed contact on NO side Plunger Contact spring Reset spring Movable contact Plunger All models have slow-action contacts with approved positive opening mechanisms on the NC contacts, thus forcibly separating the NC contacts even if they weld. (Meets the requirements of EN60947-5-1.) All models have slow-action contacts with approved positive opening mechanisms on the NC contacts, thus forcibly separating the NC contacts even if they weld. (Meets the requirements of EN60947-5-1.) 5

Dimensions Note: All units are in millimeters unless otherwise indicated. Shaft Type with 1 Conduit -1 AS -2 AS -3 AS R2.15±0.05 mounting hole 20.5 x 20.5 8±1 8.5±0.1 dia. Depth: 20 min. 12.5 dia. 17 dia. Two, 3.2±0.1 dia. Two, 3.2±0.1 dia. 31 max. Conduit opening Two, 4 +0.15 0 holes Depth: 5 min. Shaft Type with 2 Conduits -5 AS -6 AS 8.5±0.1 dia. Depth: 20 min. 20.5 x 20.5 8±1 R2.15±0.05 mounting hole 21.5±0.2 17 dia. 12.5 dia. Two, 3.2±0.1 dia. Two, conduit opening 25 dia. Two, 3.2±0.1 dia. Conduit cap 56 max. Two, 4 +0.15 0 holes Depth: 5 min. Arm Lever Type with 1 Conduit -1 BC -2 BC -3 BC 11 20 5 x 20.5 R2.15±0.05 mounting hole 21.5±0.2 31 max. Conduit opening Two, 4 +0.15 0 holes Depth: 5 min. 6

Arm Lever Type with 2 Conduits -5 BC -6 BC 11±0.2 20 5 x 20.5 R2.15±0.05 mounting hole Two, conduit openings 25 dia. 21.5±0.2 Conduit cap 56 max. Two, 4 +0.15 0 holes Depth: 5 min. Note: 1. Each dimension has a tolerance of ±0.4 mm unless otherwise specified. Operating force Pre-travel angle 1 (NC) (7 ) Pre-travel angle 2 (NO) (see note 2) (19 ) Positive opening travel (min.) Positive opening force (min.) 0.15 N m {1.53 kgf cm} max. 45 min. 2. Applicable to models with 1NC and 1NO contacts. Application Examples 1 N m {10.2 kgf cm} min. Application Examples of Arm Lever Use Note: Be sure to evaluate the Switch under actual working conditions after installation. Shaft Actuator Arm Lever Actuator 7

When Installing at the Center The arm lever is set for center installation at the time of shipment. When Installing to the Left Remove the screw and arm lever, position the arm lever to the left, and then secure it with the screw. Note: Install the arm lever so that it will not rotate more than 90. Otherwise, the lever will hit the switch body. When Installing to the Right Remove the screw and arm lever, position the arm lever to the right, and then secure it with the screw. Note: Install the arm lever so that it will not rotate more than 180. Otherwise, the lever will hit the switch body. Note: Install the arm lever so that it will not rotate more than 180. Otherwise, the lever will hit the switch body. 8

Precautions! CAUTION Do not disassemble or touch inside under power-on. Electrical shock hazard may be caused. Do not use metal connectors or conduits with this Switch. Rigid connectors and conduits may damage the Switch. The broken conduit hole may cause electrical shock hazard. NOTICE If the is applied to an emergency stop circuit or safety circuit for prevention of injury, use the NC contact, which incorporates a force-separation mechanism, and make sure that the operates in positive mode. Furthermore, secure the with screws or equivalent parts that are tightened in a single direction so that the or operation key cannot be easily removed or provide a protection cover to the and post a warning label near the. Protect the with an appropriate cover and post a warning sign near the for safety reasons so that the will not be removed carelessly. To protect the from damage due to short-circuits, connect the in series to a fuse that has a breaking current 1.5 to 2 times the rated current of the. If the is used under EN-approved rating conditions, use a 10 A fuse, type gi or gg conforming to IEC 269. Do not touch the live switch terminal. Electric shock hazard may be caused. Do not use the in locations subject to corrosive or flammable gases. Make sure that the load current does not exceed the rated current and that the load terminals are wired correctly. Pay utmost attention to correctly wire each terminal. Be sure to evaluate the Switch under actual working conditions after installation. Do not use the Switch as a stopper. Do not drop or disassemble the. Life Expectancy The life of the will vary with the switching conditions. Before applying the, test the under actual operating conditions and be sure to use the in actual operation within switching times that will not lower the performance of the. Operating Environment The is for indoor use only. Do not use the outdoors. Otherwise, the may malfunction. Be sure that no metal dust, oil, or chemical will be sprayed onto the, otherwise the may malfunction. Do not use the in the following locations: Locations with severe changes in temperature Locations with excessive humidity that may cause condensation Locations with excessive vibration Locations where metal dust, oil, or chemical may be sprayed onto the Mounting Screw Tightening Torque Be sure to tighten each screw of the properly, otherwise the may malfunction. (7) (5) (4) (1) (2) No. Type Torque (1) Terminal screw (M3.5) (2) Cover mounting screw (3) Head mounting screw (4) Body mounting screw (M4) (See note 1) (5) Arm lever mounting screw (M5 x 0.8) (6) Connector at conduit opening (7) Cap screw (see note 3) Note: 0.59 to 0.78 N m {6 to 8 kgf cm} 0.78 to 0.88 N m {8 to 9 kgf cm} 0.78 to 0.88 N m {8 to 9 kgf cm} 0.49 to 0.69 N m {5 to 7 kgf cm} 1.57 to 1.77 N m {16 to 18 kgf cm} 1.77 to 2.16 N m {18 to 22 kgf cm} (3) (6) 1.37 to 1.77 N m {14 to 18 kgf cm} (see note 2) 1.27 to 1.67 N m {13 to 17 kgf cm} 1. Tighten each screw together with a washer to the specified torque. 2. This torque range applies to 1 / 2-14NPT connectors. 3. For 2-conduit models only. 9

Mounting Be sure the that operates properly after mounting and adjusting the. Use two M4 screws (one-way screws, etc.) and washers to mount the securely. The can be mounted more securely with two protruding portions inserted into the lower part of 0.05 the as shown below. Each protruding portion is 4 0.15 mm in diameter with a maximum height of 4.8 mm. Be sure that the arm lever moves smoothly when the door opens or closes. 1 to 3 8 to 10 dia. 1 to 3 4.5 to 5 dia. Mounting Holes Standard Model 2-conduit Model 0.05 4 0.15 dia., height: 4.8 max. Arm Lever Mounting Position The arm lever is mounted upwards in the center position before shipping. To change the position, loosen the arm lever mounting screw, dismount the arm lever, and mount the arm lever in the left or right position. Head Direction By removing the four screws of the head, the mounting direction of the head can be changed. The head can be mounted in four directions. Be sure that no foreign material will enter during a change in direction. 0.05 4 0.15 dia., height: 4.8 max. Mounting hole Mounting surface Insertion hole for protruding portion Mount the shaft or arm lever with a one-way screw, or an equivalent securely so that the shaft or arm lever cannot be easily dismounted. Although the shaft withstands a force exceeding 500 N {approximately 50 kgf}, do not impose a force of 50 N {approximately 5 kgf} or more on the shaft. 10

Wiring Do not connect lead wires directly to the terminals. Be sure to connect the lead wires through insulation tubes and crimp terminals. The tightening torque applied to each crimp terminal is 0.59 to 0.78 N m {6 to 8 kgf cm}. The lead wires must be an AWG20 to AWG14 type (i.e., 0.5 to 2.5 mm 2 thick). dz dia.: 3.7 D dia.: 4.5 B: 7.0 L: 20.2 F: 7.7 I: 9.0 (mm) D dia. dz dia. Wire the crimp terminal as shown in the following diagram so that it will not come in contact with the case or cover. Crimp terminal Correct Terminal screw Incorrect Conduit Opening The torque required to tighten a connector other than a 1/2-14NPT connector is 1.77 to 2.16 N m {18 to 22 kgf cm}. The torque required to tighten a 1/2-14NPT connector is 1.37 to 1.77 N m {14 to 18 kgf cm}. The casing may be damaged if an excessive tightening torque is applied. For the casing to maintain IP65, apply sealing tape between the connector and conduit opening. Be sure that the diameter of the cable connected to the connector is correct. When wiring a 2-conduit model, attach and tighten a conduit cap to the unused conduit opening. The torque to be applied to the conduit cap is 1.27 to 1.67 N m {13 to 17 kgf cm}. The conduit cap is provided with the. Recommended Connectors Size Manufacturer Model Cable diameter G 1 / 2 OMRON SC-6 7.5 to 9.0 mm LAPP ST-PF1/2 6.0 to 12.0 mm 5380-1022 Ohm Denki OA-W1609 7.0 to 9.0 mm Pg13.5 LAPP ST13.5 5.0 to 12.0 mm 5301-5030 HEYCO 3216 4.3 to 11.9 mm 1 / 2-14NPT LAPP ST-NPT1/2 6.0 to 12.0 mm 5301-6030 HEYCO 3231 4.3 to 11.9 mm Note: LAPP is a German manufacturer. Ohm Denki is a Japanese manufacturer. HEYCO is an American manufacturer. Maintenance and Repairs Please note in the machine manufacturer s instruction manual that the user must not repair or maintain the Switch and must contact the machine manufacturer for any repairs or maintenance. Others Use the D4BS under conditions requiring greater rigidity, sealing performance, and oil resistance. 11

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C106-E1-2 OMRON Corporation Industrial Control Components Division 28th Fl., Crystal Tower Bldg., 1-2-27, Shiromi, Chuo-ku, Osaka 540-6028 Japan Phone: (81)6-949-6025 Fax: (81)6-949-6029 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0898-1M (0497) 12