PFS-FN FEATURES: * ASME & ISO RECOGNIZED * * WIDELY ACCEPTED TEST STANDARD * * RELIABLE PERFORMANCE HISTORY * * ACCURATE METERING SOLUTION *

Similar documents
Flow nozzle for in-pipe installation, model FLC-FN-PIP Flow nozzle for flange assembly, model FLC-FN-FLN Venturi nozzle, model FLC-FN-VN

Fundamentals of Natural Gas Measurement

ORIFICE PLATE flow meters

TRANSMITTER ATTACHES TO THIS SURFACE

94D / 94F / 94M / 96M

ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES

STEEMCO Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

IFOA Integral Flow Orifice Assembly

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

IntraNozzle Flow Nozzle Type: IFN

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

ORIMAS Mass Flowmeter

Rosemount 1195 Integral Orifice Primary Element

EMCO Primary Elements for Flow Measurement

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Practical Guidelines for Specifying Orifice Fittings

VERIS FLOW MEASUREMENT GROUP

Square Edged Concentric

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

VENT SILENCER PRODUCT GUIDE

Experiment (4): Flow measurement

FLUID CONTROL RESEARCH INSTITUTE

Datasheet MATRE Foam Inductors. Datasheet for MATRE Foam Inductors. 1 Contents

The calculation of fluid flow

Differential Pressure - Primary Flow Element Wedgemeter II Series WM: C/F/P

T5 Flare Gas Transducer

Background. The function of wear rings. Wear Rings. Throat Bushing

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Dual Chamber Orifice Fitting

FLOW NOZZLES - 3 SAMIL INDUSTRY CO.,LTD. IN THIS CHAPTER - 3

Class 300, Welding Neck, Slip-On and Threaded B16.47, Ser. A. ASME B16.5 Flanges

FLOW E L E M E N T S

Orifice plates and nozzles. Flow measurement using differential pressure

INSTALLATION, OPERATION and MAINTENANCE MANUAL for FLOTEC SENSOR

Worcester 18/19 Series. Modular Multi-Way Ball Valves

TM Tecnomatic is the 1 st European Company for Flow Measurement Devices

FLANGE. Flanges used for

DuPont Vespel CR-6100 APPLICATION AND INSTALLATION GUIDE FOR CENTRIFUGAL PUMP STATIONARY WEAR PARTS

CHAPTER 1: INSTRUMENTATION EQUIPMENT MODULE 5: Flow Instrumentation

SECTION METERS AND GAGES FOR HVAC PIPING

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

RTD Temperature Sensor omnigrad T -TR 470

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.

Forged High Pressure Pipe Fittings

Bore (B) Pitch Diam. Drilling Template Flanges (1) Diam of Diam of. Groove. Neck D X G A Raised Face Raised Face P Raised face

Installation Instructions

Datasheet Rev.1 Feb 2014 High precision flowmeter

Datasheet December Daniel Orifice Plates and Plate Sealing Units Differential Pressure Flow Meters

Fisher 461 Increased Outlet Angle Sweep-Flo Valve

Rosemount 285 Annubar Primary Element Series

Worcester 18/19 Series. Modular Multi-Way Ball Valves

LDV / LDVQ 5000 AIR VOLUME CONTROL VALVE INSTALLATION MANUAL. Date: 02 / 10 Reference # : F-36. w w w. p r i c e - h v a c. c o m

Field IT Differential Pressure Flow Elements

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Product Data Sheet , Rev KA April 2010 Rosemount 1495 and Contents

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

INSERTION flow sensor for continuous flow measurement

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

Please note this is a condensed catalog. For a complete version, contact Velan directly.

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Yl)HAl STrrl (INDIA) Forged High Pressure Pipe Fittings. All ISO 9001:2003/ ISO 14001:2004 / 8S Ol!SAS 18001:2007 / PED Al'PROl'ED 97/23/EC

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Experiment No.3: Flow through orifice meter. Background and Theory

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

1495 Orifice Plate 1496 Flange Union 1497 Meter Section Installation & Operation Manual

FLUID FLOW. Introduction

Datasheet Rev.3 Feb 2015 Venturi tube

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

C7170A,B Encapsulated Temperature Sensor

Family of Products 1100 SERIES 1500 SERIES. 3 Piece Full Port Fire Safe Ball Valve ANSI Class WOG

TM Tecnomatic is the 1 st European Company for Flow Measurement Devices

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

TRUNNION MOUNTED METAL SEATED BALL VALVES

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

Sleeve Valves Energy Dissipaters

Cartridge Filter Housings Nowata A Series

Flowserve TX2 Butterfly Valves Triple Offset TECHNICAL BULLETIN FCD DVENTB

Impacts of Short Tube Orifice Flow and Geometrical Parameters on Flow Discharge Coefficient Characteristics

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

SERIES DESUPERHEATERS

Yarway Narvik Model 37 and 47 Cryogenic injector

Orifice Fittings and Meter Tubes

Yarway Narvik Ven-Temp Desuperheater Model 25

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

SECTION METERS AND GAGES FOR PLUMBING PIPING

Condensate Drain Valve AK 45. Original Installation Instructions English

EMERSON. CONSIDER IT SOLVED

Vertical Pre-Piped Bladder Tanks with Proportioner

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Smart Electromagnetic Flowmeter Detector for Sanitary use

Sample Probe Module. Application Guide

Fisher CAV4 Control Valve

General Engineering Spray Nozzles & Accessories

Specifications. Body Materials: Carbon steel, stainless steel, chrome-moly steel, other castable alloys

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

Direct Contact Desuperheaters

Transcription:

FEATURES: * ASME & ISO RECOGNIZED * * WIDELY ACCEPTED TEST STANDARD * * RELIABLE PERFORMANCE HISTORY * * ACCURATE METERING SOLUTION * * FLEXIBLE DESIGN & MATERIALS *

2 PFS FLOW NOZZLE TYPES PFS-NZF PFS-NZFT The PFS-NZF type nozzle is machined with a holding flange that is flush with the inlet contour of the element. This flange is typically of raised face or ring joint construction. The nozzle is mounted concentrically within the process flanges of the pipe section in which it is installed. Each nozzle is provided with a close tolerance shoulder downstream of the holding flange to insure its concentricity within the metering run. The PFS-NZFT is furnished with the downstream pressure tap machined integrally in the nozzle holding flange. It is a flanged nozzle used primarily in smaller line sizes where the downstream tap may cause interference with the pipe weld, mounting flange and/or assembly bolting. This nozzle is most commonly supplied in sizes of 4 and below and furnished with a 1/2 NPT-F as standard. PFS-NZWI PFS-NZHR The PFS-NZWI nozzle is designed for installation in the metering run by welding. The nozzle is furnished with a machined boss on the outside diameter of the shoulder which assists in its installation between the beveled ends of the up and downstream pipe sections. This nozzle is extensively used in applications that preclude the use of mounting flanges such as high pressure/ temperature feedwater and steam measurements in power plants. The PFS-NZHR nozzle is supplied in a precision bored metering pipe where the welding of dissimilar metals is prohibited or not preferred. A holding ring is welded into the meter pipe with the nozzle subsequently pulled through and locked into place via pins that are installed through the pipe wall, holding ring and nozzle body. The pipe, ring and pins are all of compatible material designation. In line sizes below 4 please contact PFS.

GENERAL FEATURES - PFS FLOW NOZZLES 3 LINE SIZE/BETA RATIO ASME Nozzles manufactured in accord with ASME MFC-3M-2004 are supplied in 2.0-25.0 Line ID Beta Ratio Range: 0.20-0.80 NOZZLE MATERIAL Nozzles are furnished in 300 series Stainless Steel for most applications due to the high velocities and extreme environments to which they are exposed. Other materi als are available for extreme temperatures and corrosive service. PRESSURE TAPS For ASME Wall Tap Installation: High Pressure: 1 Dia Upstream of Nozzle Inlet Face Low Pressure: 0.5 Dia Downstream of Nozzle Inlet PRESSURE TAPS (cont d) For ASME Throat Tap Installation: High Pressure: 1 Dia Upstream of Nozzle Inlet Face Low Pressure: Nozzle Throat-Code Specified Location ACCURACY Nozzle accuracy is dependent on several functions inclu sive of piping configuration, beta ratio and Reynolds number. The ASME MFC standard indicates a discharge coefficient uncertainty of +/- 2% for nozzles fabricated in accord with this specification. This may be improved through hydraulic Lab Calibration. PIPING REQUIREMENTS Table 3-3 below indicates up and downstream piping re quirements for these nozzles. These lengths may be re duced through the use of flow conditioners.

4 TYPICAL CALIBRATION-ASME NOZZLE DISCHARGE COEFFICIENT ASME Nozzles manufactured in accord with ASME MFC- 3M-2004 and supplied with pipe wall taps have a discharge coefficient that is characterized by the equation below: The lab calibration report presented here is representa tive of a wall tap assembly.

5 PRIMARY FLOW SECTIONS FOR ASME PTC-6 PERFORMANCE TEST

6 ASME PTC-6 FLOW NOZZLE TYPES Fig. 1 - PTC6-NZFT The PTC6-NZFT type nozzle assembly is typically provided for the measurement of condensate return flow where line pressures are low to moderate. The construction of this assembly allows for easy removal and inspection of the nozzle, pressure taps and piping during performance testing. The assembly is most commonly supplied with carbon steel process piping, 304 stainless steel flow nozzle and flow conditioner. Other material combinations and grades can be supplied as required. Fig. 2 - PTC6-NZWI The PTC6-NZWI type nozzle assembly typically provided for the measurement of final feedwater flow where line pressures are high. The nozzle can be furnished with the diffuser cone integral to the flow nozzle or as an attachment. Inspection ports are supplied as standard to allow for code recommended nozzle inspection during performance testing. The assembly is most commonly supplied with carbon steel process piping, carbon steel inspection port, 304 stainless steel nozzle and flow conditioner. Other material combinations and grades can be supplied as process conditions dictate.

7 ASME PTC-6 FLOW NOZZLE-ACCURACY & CALIBRATION

8