FR600G Series AC Transfer Pumps

Similar documents
FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps

FR310V Parts List WARNING! DO NOT

Owners Installation, Operation, and Safety Manual. Series 300V. Fuel Transfer Pump. Series 300V 115 and 230 VOLT AC

Owners Installation, Operation, and Safety Manual

M-3025CB-AV Fuel Pump

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

Owner s Operation and Safety Manual High Flow DC Powered Fuel Transfer Pump

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Remote Dispensing Cabinet 902V Series Cabinet Dispenser

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

DSTP20: Fuel Transfer Pump

M-1115S Series Fuel Pump

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

Model DEF Pump Diesel Exhaust Fluid Transfer Pump

Electric Fuel Pump FPM

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc.

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

Electric Fuel Pump FPM

M-3020 STOP. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

Owner s Installation and Operation Manual 8 GPM DEF Pump

STOP. Contractor Special Fuel Pumps. Heavy Duty Fuel Pumps. Use this manual with: M-3425CS 24-Volt DC. M Volt DC & M Volt DC

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

ILLUSTRATED PARTS LIST

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE!

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual

Model 1210C Battery Powered Pump Shown

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

Electric Diesel Pump EDP/12, EDP/24

M-150S, M-180S & M-240S FUEL PUMP

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

SERIES FR400 DIAPHRAGM PUMP

AC 700 SERIES FUEL PUMPS Item code: FILLRITE-AC700

Oil Pump Models L 5016, L 5116 & L 5132

STOP. M-150S-Methanol Pump Owner s Manual SAVE THESE INSTRUCTIONS DO NOT RETURN THIS PRODUCT TO THE STORE! TABLE OF CONTENTS

G8 Portable Fuel Transfer Pump Owner s Manual

M-150S, M-180S. and M-240S Fuel Pump. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Digital Liquid Meter

SERIES FR400 DIAPHRAGM PUMP

GARDEN HOSE UTILITY PUMP

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972

Model &

NECO Pumping Systems

Pump System Technology. Owner's Manual SERIES LP PUMP. For series: LP50, LP200, LP450, LP650. Series LP50

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

EZ-8 & EZ-8 METHANOL FUEL PUMP

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Cast Iron Rotary Drum Pump

Fuel Transfer Pumps DC Aluminum Gear Fuel Pump with Auto Nozzle

FUEL DISPENSING SYSTEMS SE-37. Component Details. 120V AC - 20 GPM Metered Tank-top Dispensing System

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

M-1115S Series Fuel Pump

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

P-200 Plastic Utility Pump for Petroleum Products

OIL DISPENSING SYSTEM

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

12 Volt DC Diaphragm Pumps Series 400

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Polypropylene Piston Drum Pumps

Low Profile J Series Power Unit with Vane Pump

KIT Finder. The Tuthill Marketing Team

Stainless Steel Rotary Drum Pump

12V DC FUEL PUMPS Item code: FILLRITE-12V

LAWN SPRINKLER, IRRIGATION PUMP

Submersible Effluent Pump

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL

STAR STOP SHALLOW WELL JET PUMP

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

12v / 24v Diesel Transfer Pump Kit

End Suction Centrifugal

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

SHALLOW WELL JET PUMP

Ph: (07) Fax: (07) Pump Manual

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

ESE Series Cast Iron Sewage Pumps

COOKSON OWNER'S MANUAL

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

END SUCTION CENTRIFUGAL PUMPS

MODEL SAFETY & INSTRUCTION MANUAL

FUEL DISPENSING SYSTEMS SE-47. Component Details. 120V AC - 18 GPM Metered Tank-top Pump, Remote Dispensing System

Transcription:

Owners Installation, Operation, and Safety Manual FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps FR600G Series AC Transfer Pumps 1 Tuthill Transfer Systems 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.com

Table of Contents Safety Information... 3 Installation... 3 DC Electrical Wiring... 6 DC Wiring Diagram... 9 AC Electrical Wiring... 10 AC Wiring Diagram... 11 Operating Instructions... 12 Padlocking... 12 Troubleshooting... 13 Dimensional Information... 14 DC Technical Information (1200 / 2400 Series)... 15 DC Technical Information (4200 / 4400 Series)... 16 AC Technical Information... 17 Kits and Parts... 18 Accessories... 19 Safety Approvals and Certifications... 20 Motor Tag Information..... 20 Thank You! Thank you for your purchase! Your Fill-Rite product comes with over 80 years of pump manufacturing experience behind it, providing you the value that comes with superior performance, user friendly design, long service life, and solid, simple engineering. Experience that gives you peace of mind. About This Manual Excellence at work. Excellence in life. From initial concept and design through its final production, your Fill-Rite pump is built to give you years of trouble free use. To ensure it provides that service, it is critical that you read this entire manual prior to attempting to install or operate your new pump. Become familiar with the terms and diagrams, and pay close attention to the highlighted areas with the following labels: WARNING! Emphasizes an area in which personal injury or even death could result from failure to follow instructions properly. Mechanical damage may also occur. IMPORTANT! These boxes contain information that illustrates a point that may save time or may be key to proper operation, or clarifies a step. CAUTION! Failure to observe a Caution can cause damage to the equipment. At Tuthill, your satisfaction with our products is paramount to us. If you have questions or need assistance with your product, please contact us at 1-800-634-2695 (M-F 8 AM 5 PM ET). 2

Safety Information WARNING! Electrical wiring should be performed ONLY by a licensed electrician in compliance with local, state, and national electrical code NEC/ANSI/ NFPA 70, NFPA 30, and NFPA 30A, as appropriate to the intended use of the pump. Threaded rigid conduit, sealed fittings, and conductor seal should be used where applicable. The pump must be properly grounded. Improper installation or use of this pump can result in serious bodily injury, or death! WARNING! To ensure safe and proper operation of your equipment, it is critical to read and adhere to all of the following safety warnings and precautions. Improper installation or use of this product can cause serious bodily injury or death! NEVER smoke near the pump, or use the pump near open flames when pumping a flammable liquid! Fire can result! A filter should be used on the pump outlet to ensure no foreign material is transferred to the fuel tank. We recommend Fill-Rite filters for best results. Threaded pipe joints and connections must be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks. Storage tanks must be securely anchored to prevent shifting or tipping when full or empty. To minimize static electricity build up, use only static wire conductive hose when pumping flammable fluids, and keep the fill nozzle in contact with the container being filled during the filling process. The pump motor is equipped with thermal overload protection; if overheated, the motor will shut off to prevent damage to the windings. If this happens: 2400, 4400, 600, and SD600 series pumps will reset automatically when the pump cools down. 1200 & 4200 series pumps must be reset manually to operate again. Wait until the motor cools down and turn the power switch off to reset. WARNING! This product shall not be used to transfer fluids into any type of aircraft. WARNING! This product is not suited for use with fluids intended for human consumption or fluids containing water. Installation Your Fill-Rite pump is designed to be mounted on a skid tank using the threaded inlet flange supplied with the pump (see attached diagrams). Your pump features an integral bypass valve to recirculate the fluid when the pump is operating with the nozzle closed. WARNING! In Skid Tank applications, be sure the tank is properly secured so it cannot shift or move whether the tank is empty or full. CAUTION! Do not use additional check valves or foot valves unless they have a proper pressure relief valve built into them. Note that additional check valves will reduce rate of flow. 3

CAUTION! A pressure retaining fill cap can be used to reduce fuel loss through evaporation, but note that it will reduce the flow rate. CAUTION! Threaded pipe joints and connections must be sealed with the appropriate sealant or sealant tape to prevent the possibility of leaks. WARNING! Fill-Rite pumps are designed for use with stationary and mobile tank applications. While DC powered units are excellent choice for mobile applications, anchoring the tank to which the pump is mounted is paramount to ensure no movement in transit. Failure to secure the tank to the vehicle can cause uncontrolled movement, resulting in damage, injury, and potential fire. Typical Skid Tank Installation The pump mounts to the bung of a skid tank by way of the inlet flange. The suction tube threads into the bottom of the inlet flange, and must extend to a length that positions it at least 3 from the bottom of the tank. The skid tank should be equipped with a vent cap. Pump Vent Cap Tank 3 Min 4

Typical Skid Tank Installation Materials: 1 telescoping suction pipe extended to a length that will extend to within 3 of the bottom of the tank when screwed into the tank adapter with the tank adapter screwed into the tank flange (see SKID TANK INSTALLATION diagram). Threaded pipe joint sealant appropriate for application. Gasket Screen Installation Assembly View Tank Adapter Telescoping Suction Pipe Installation Procedure: 1. Thread the 1 pipe into the tank adapter. Seal threads liquid tight with appropriate sealant. (Figure 1) Figure 1 5

Typical Skid Tank Installation (cont d) 2. Screw the inlet flange (with suction pipe) into the tank bung; seal threads liquid tight with appropriate thread sealant (Figure 2). Figure 2 3. Mount the pump on the adapter; making sure the seal and screen are installed as shown. (Figure 3). Figure 3 Electrical Wiring DC Wiring Procedure FR1200G / FR2400G / FR4200G / FR4400G / SD1202G Series DC Transfer Pumps CAUTION! DC powered pumps are designed to operate on either 12 or 24 VDC (depending on model). Where applicable, use the supplied battery cable to supply power to the pump from a 12 or 24 VDC battery. A 30 amp fuse (20 amp fuse on 24 VDC motors) should be installed on the battery cable (see wiring diagram page 9) to protect the wire in case of electrical short. CAUTION! Voltage drop in wiring varies depending on the distance from the battery to the pump and the gauge of the wire used. If the distance is greater than 20, refer to national, international, or local electrical codes to ensure the wire is of the correct size for this application. 6

Instructions Before Proceeding With DC Wiring The pump needs to be electrically bonded to supply tank or vehicle frame. To electrically bond pump, remove green bonding screw located next to junction box cover. Insert this screw through eyelet of furnished green bonding wire assembly and refasten it securely to the pump. The other end of the wire is to be stripped of insulation and the bare wire securely bonded to the vehicle / trailer frame or skid tank. WARNING! Do not connect the positive or negative power to the green screw or wire as this could cause a fire. Wiring Instructions (see Figure 4, Page 8) 1. Remove pump s electrical junction box cover and straighten the 2 wires to make the stripped wire ends accessible outside of the junction box. 2. Screw furnished cable connector into NPT* conduit opening in pump junction box. 3. Strip 6 inches of the outer covering from one end of the furnished electrical cable being careful not to damage the black and red wire insulation. 4. Loosen cable connector nut and pass the stripped end of the furnished cable through the cable connector. Tighten the cable connector nut. 5. Strip ½ inch of the insulation from the ends of the red and black cable wires. Using the furnished wire nuts, connect these wires to the pump wires matching the colors. Be sure no bare wire is exposed. 6. Fold wires into junction box and replace cover making sure the gasket is in place. Make sure all screws are seated so there is no space between the cover and the junction box (see IMPORTANT! information box and diagram page 10). Wiring To A Vehicle Electrical System (see wiring diagram, page 9) 1. Pass the electrical wires to the source of the vehicle power system, supporting the wires as necessary and protecting them from sharp edges, heat, and anything that could damage the wires. 2. To determine if the vehicle electrical system is negative (-) or positive (+) ground, check the battery marking of the terminal that is wired to the vehicle frame or motor block. The red wire from the pump will connect to positive battery post and the black wire from the pump will connect to negative battery post. 3. Attach one end of the fuse holder to the end of the ungrounded wire. Make a solid electrical connection with the other end of the fuse holder to the ungrounded side of the battery, as close to the battery as possible. Make a solid electrical connection to the grounded side of the battery with the remaining wire. The battery terminal or the end of the battery cable is recommended. 4. Check all connections to make sure they are connected per instructions and all electrical codes. Install the 30 amp fuse (20 amp fuse in 24 VDC installations) in the fuse holder. The installation is now complete. WARNING! Do not attempt to power the pump from vehicle wiring smaller than 12 gage such as the cigarette lighter wire because these thin wires could overheat and cause a fire. 7 *M20 Conduit entry on GE models

DC Wiring (cont d) For Skid Mounted Tanks 1. Pass the electrical wires to the power source, supporting the wires as necessary and protecting them from sharp edges, heat and anything that could damage the wires. 2. Attach one end of the fuse holder to the red pump wire, as close to the battery / power source as possible. Make a solid electrical connection to the positive terminal of the power source with the other end of the fuse holder. Make a solid connection with the black pump wire to the negative terminal of the power source. 3. Check all connections to make sure they are connected per instructions and all electrical codes. Install the 30 amp fuse (20 amp fuse in 24 VDC installations) in the fuse holder. The installation is now complete. Figure 4 Junction Box Wire in 8

DC Wiring Diagram DC Wiring Diagram Fuse to be located outside of hazardous area, as close to the power source as possible. If the wiring from the power source to the pump is greater than 20, refer to the applicable Electrical Code (National, International, or local) to ensure the wire is of the correct size for the application. Fuse to be located outside of hazardous area, as close to the power source as possible. If the wiring from the power source to the pump is greater than 20, refer to the applicable Electrical Code (National, International, or local) to ensure the wire is of the correct size for the application. 9

AC Wiring Instructions FR600G / SD602G AC Transfer Pumps WARNING! Electrical wiring should be performed ONLY by a licensed electrician in compliance with local, state, and national electrical code NEC/ ANSI/NFPA 70, NFPA30, and NFPA 30A, as appropriate to the intended use of the pump. The pump must be properly grounded. Improper installation or use of this pump can result in serious bodily injury, or death! CAUTION! All pumps should operate at the rated nameplate voltage. AC power should be supplied to the pump from a dedicated circuit with 15 amp circuit protection. No other equipment should be powered by this circuit. Wiring must be of sufficient size to carry the correct current for the pump (minimum 12 gauge). Voltage drop will vary with distance to pump and size of wire; refer to the National Electrical Code (NEC), or local codes, for voltage drop compensation to be sure you are using the correct size wire for your application. AC Wiring Procedure 1. Remove the junction box cover and straighten the wires to make sure the stripped wire ends are accessible outside the junction box. 2. Install rigid conduit and appropriate wiring from power source to the junction box to maintain the explosion proof integrity. Power should be supplied from a dedicated 15 amp circuit breaker; no other equipment should be powered by this circuit. 3. Connect the pump wires to the power supply lines according to the wiring diagram (page 11). Be certain to properly insulate the connections with the appropriate wire nuts or other connectors. Note that the ground wire MUST be connected (ground wire connection is inside the junction box; see figure 5, page 11). 4. Fold the wires back into the junction box and replace the cover, making sure the cover gasket is in place. IMPORTANT! Be certain the gasket for the junction box cover is in place, and the screws draw the cover down tight over the junction box. There must be no gap between the junction box and it s cover. The seal should be weather tight to prevent moisture from entering the junction box. Junction Box Gasket Junction Box Cover 10

AC Pump Junction Box (FR600G Series AC Transfer Pumps) Ground screw in junction box Figure 5 AC Wiring Diagram (FR600G Series AC Transfer Pumps) WARNING! Ground wire in supply wiring MUST be connected to the ground screw inside the junction box. 11

Operating Instructions WARNING! Always keep the nozzle in contact with the container being filled during the filling process to minimize the possibility of static electricity build up. 1. If so equipped, reset meter to 0 (do not reset while in use as this will cause damage to the meter). 2. Remove dispensing nozzle from nozzle boot. 3. Move the switch lever to the ON position to power the pump (figure 5). 4. Insert the dispensing nozzle into the container to be filled. 5. Operate the nozzle to dispense fluid; release nozzle when the desired amount of fluid has been dispensed. Figure 5 ON position 6. Move switch lever to the OFF position (Figure 6) to turn off the pump. 7. Remove the dispensing nozzle from the container being filled and store it in the nozzle boot. Figure 6 OFF position Padlocking Your Fill-Rite pump nozzle can be padlocked to the pump for added security. With the pump turned off, and the nozzle in the stored position, a padlock can be inserted through the locking link and the nozzle handle. The locking link is located on the nozzle side of the pump, and can be pivoted into position to work with a variety of nozzles (Figure 7). Figure 7 Locking Link 12

Troubleshooting The following troubleshooting guide is provided to offer basic diagnostic assistance in the event you encounter abnormal service from your Fill-Rite product. If you have questions regarding installing, operating, or servicing your product, please feel free to contact our Customer Service Department at 1-800-634-2695 (M-F 8 AM 5 PM ET). You can also reach us on the World Wide Web at www.fillrite.com. WARNING! DO NOT open or attempt to repair the motor on your Fill-Rite pump. Return it to the place of purchase for service. Opening the motor case can compromise the integrity of the Explosion Proof construction and will void any existing warranty and certification. WARNING! Be certain all power to the pump is disconnected prior to performing any service or maintenance. Symptom Cause Cure Check for leaks or obstructions in 1. Suction line problem. suction line. Remove and inspect valve; must 2. Bypass valve open. move freely & be free of debris. Check vanes and slots for nicks, 3. Vanes sticking. burrs and wear.* Pump won't prime. Low capacity. Pump runs slowly. 4. Excessive rotor or vane wear. 5. Vapor Lock. 13 Inspect rotor & vanes for excessive wear or damage; replace if necessary.* Reduce vertical and horizontal distance from pump to liquid; remove automatic nozzle. 1. Excessive dirt in screen. Remove and clean screen. Check suction line for leaks or 2. Suction line problem. restrictions; it may be too small, too long or not airtight. Remove and inspect valve; must 3. Bypass valve sticking. move freely & be free of debris. Check pump outlet, hose, nozzle & 4. Outlet blocked. filter for blockage. 5. Vanes sticking. Check vanes and slots for wear.* Inspect rotor & vanes for excessive 6. Excessive rotor or vane wear or damage; replace if wear. necessary.* 7. Hose or nozzle damage. Replace hose or nozzle. 8. Plugged filter. Replace filter. 9. Low fluid level. Fill tank. 1. Incorrect voltage. Check incoming line voltage while pump is running. 2. Vanes sticking. Inspect vanes and slots for nicks, burrs and wear.* 3. Wiring problem. Check for loose connections. 4. Motor problem. Return to place of purchase. See page 14 for explanation of Bold text and * items.

Troubleshooting (cont d) Motor stalls / fuse blows or thermal protector trips repeatedly. Motor overheats. Motor Inoperative. Fluid leakage. Pump hums but will not operate. Remove and inspect valve; must 1. Bypass valve sticking. move freely & be free of debris. Check incoming line voltage while 2. Low voltage. pump is running. 3. Excessive rotor or vane Check rotor & vanes for excessive wear. wear or damage.* 4. Debris in pump cavity. Clean debris from pump cavity. 1. Pumping high viscosity fluids. These fluids can only be pumped for short periods of time (less than 30 minutes duty cycle). 2. Clogged screen. Remove and clean screen. 3. Restricted suction pipe. Remove and clean pipe. 4. Motor failure. Return to place of purchase. Clean and check pump rotor and 5. Pump rotor lock-up. vanes.* 1. No power Check incoming power. 2. Switch failure. Replace switch (KIT120SW). 3. Motor failure. Return to place of purchase. 4. Thermal protector Return to place of purchase. failure. 5. Incorrect/loose wiring. Check wiring. 1. Bad o-ring gasket. Check all o-ring gaskets. 2. Dirty shaft seal. Clean seal & seal cavity. 3. Bad shaft seal. Replace seal. Refer wetted parts list to fluid 4. Incompatible fluid. manufacturer. 5. Loose fasteners. Tighten fasteners. 1. Motor failure. Return to place of purchase. 2. Broken rotor key. Remove all debris & replace key. Bold text indicates service that cannot be performed by the owner; pump must be returned to the point of purchase for this type of service. * Repairs marked with an asterisk (*) will require Repair Kit KIT120RG Kit includes replacement rotor and new vanes, as well as a number of other important seals and components to complete the repair. Details of this kit are on page 18. WARNING! Disconnect electrical power and relieve any pressure in the lines prior to servicing this pump! Failure to do so can result in damage to the equipment and personal injury or death! Dimensional Information 14

Technical Information DC pumps (G/GE models) Motor Power - AC 115, 230, 115/230 VAC N/A N/A HZ 50, 60, 50/60 N/A N/A Power - DC 12, 24, 12/24 12 24 HP (horsepower) rating 1/4 HP 1/4 HP Power cord length (feet) 18' 18' Power cord gauge (AWG) 12 AWG 12 AWG DC Power cord connectors NONE NONE Amps (FLA) 20 10 RPM 2600 2600 Duty cycle 30 min. 30 min. Thermal protection switch Yes Yes Circuit protection fuse NONE NONE Certification UL, cul Motor, ATEX, CE*, ANZEx, INMETRO UL, cul Motor, ATEX, CE*, ANZEx, INMETRO Pump Type- rotary, diaphragm, gear, vane FR1200 Series Rotary Vane FR2400 Series Rotary Vane GPM in supplied configuration Up to 15 Up to 15 GPM open flow - no hose or nozzle Up to 18.5 Up to 18.5 By-pass pressure rating (psi) - Max 16 psi 16 psi Dry vac (in Hg) 5 5 Head- Max (Ft.) 37 37 Anti-siphon valve None None Inlet - Size / Thread 1 NPT 1 BSPP* 1 NPT 1 BSPP* Outlet Size / Thread 3/4 NPT 3/4 BSPP* 3/4 NPT 3/4 BSPP* Mount 2 Bung NPT 2 BSPT* 2 Bung NPT 2 BSPT* Material -pump housing Cast Iron Cast Iron Material- wetted material BUNA-N BUNA-N Rotor material Powdered Iron Powdered Iron Rotor vane material Sintered Bronze Sintered Bronze Compatible fluids Diesel, gasoline, BioDiesel to B20, E15, Kerosene Diesel, gasoline, BioDiesel to B20, E15, Kerosene Strainer Mesh Size 20 x 20 20 x 20 Warranty 2 Years 2 Years Certification FR1200 Series ATEX, CE*, ANZEx, INMETRO FR2400 Series ATEX, CE*, ANZEx, INMETRO 15 * CE certified models: see page 20

Technical Information DC pumps (G/GE models) Motor FR4200 Series FR4400 Series Power - AC 115, 230, 115/230 N/A N/A HZ 50, 60, 50/60 N/A N/A Power - DC 12, 24, 12/24 12 24 HP (horsepower) rating 1/4 HP 1/4 HP Power cord length (feet) 18' 18' Power cord gauge (AWG) 12 AWG 12 AWG DC Power cord connectors NONE NONE Amps (FLA) 20 10 RPM 2600 2600 Duty cycle 30 min. 30 min. Thermal protection switch Yes Yes Circuit protection fuse NONE NONE Certification Pump Type- rotary, diaphragm, gear, vane UL, cul Motor, ATEX, CE*, ANZEx, INMETRO Rotary Vane ATEX, CE*, ANZEx, INMETRO Rotary Vane GPM in supplied configuration Up to 20 Up to 20 GPM open flow - no hose or nozzle 21 Up to 20 By-pass pressure rating (psi) - Max 16 psi 16 psi Dry vac (in Hg) 5 5 Head- Max (Ft.) 37 37 Anti-siphon valve None None Inlet - Size / Thread 1 NPT 1 BSPP* 1 NPT 1 BSPP* Outlet Size / Thread 1 NPT 1 BSPP* 1 NPT 1 BSPP* Mount 2 Bung NPT 2 BSPT* 2 Bung NPT 2 BSPT* Material -pump housing Cast Iron Cast Iron Material- wetted material BUNA-N BUNA-N Rotor material Powdered Iron Powdered Iron Rotor vane material Sintered Bronze Sintered Bronze Compatible fluids Diesel, gasoline, BioDiesel to B20, E15, Kerosene Diesel, gasoline, BioDiesel to B20, E15, Kerosene Strainer Mesh Size 20 x 20 20 x 20 Warranty 2 Years 2 Years Certification FR4200 Series ATEX, CE*, ANZEx, INMETRO FR4400 Series ATEX, CE*, ANZEx, INMETRO 16 * CE certified models: see page 20

Technical Information AC Pumps Motor Power -AC 115, 230, 115/230 115 VAC 115 VAC HZ 50, 60, 50/60 60 HZ 60 HZ Power - DC 12, 24, 12/24 N/A N/A HP (horsepower) rating 1/6 HP 1/6 HP Power cord length (feet) N/A N/A Power cord gauge (AWG) N/A N/A DC Power cord N/A N/A Amps (FLA) 2.0 A 2.0 A RPM 2000 2000 Duty cycle 30 min. 30 min. Thermal protection switch Yes Yes Circuit protection fuse None None Certification UL/cUL UL/cUL Pump Type- rotary, diaphragm, gear, vane Rotary Vane Rotary Vane GPM in supplied configuration Up to 14.8 Up to 14.8 GPM open flow - no hose or nozzle Up to 17.4 Up to 17.4 By-pass pressure rating (psi) - Max 16 psi 16 psi Dry vac (in Hg) 5 5 Head- Max (Ft.) 37 37 Anti-siphon valve None None Inlet - Size / Thread 1 NPT 1 NPT Outlet Size / Thread 1 NPT 1 NPT Mount 2 Bung (NPT) 2 Bung (NPT) Material -pump housing Cast Iron Cast Iron Material- wetted material BUNA-N BUNA-N Rotor material Powdered Iron Powdered Iron Rotor vane material Sintered Bronze Sintered Bronze Compatible fluids FR600 FR600 Diesel, gasoline, BioDiesel up to B20, E15, Kerosene SD600 SD600 Diesel, gasoline, BioDiesel up to B20, E15, Kerosene Strainer Mesh Size 20 x 20 20 x 20 Warranty 2 Years 1 Years Certification UL/cUL UL/cUL 17

Kits and Parts # Kit Description Parts 1 KIT120BD* BioDiesel Kit* 2 KIT120RG Rotor & Vane Kit O-ring seal, bypass valve poppet, bypass cap seal, inlet seal Rotor cover, rotor, vanes, rotor key, O-ring seal, attaching hardware 3 KIT120JC Junction Cover Kit Junction cover, seal, fasteners 4 KIT120SL Seal Kit O-ring, shaft seals, retainer clip 5 KIT120BV By-Pass Service Kit Screen, bypass valve, valve spring, bypass cap, O-ring seal 6 KIT120NB Nozzle Boot Kit Nozzle boot, attaching hardware 7 KIT120BG Inlet Flange Kit Inlet flange (bung), attaching hardware, inlet seal, screen 8 KIT120SG Inlet Gasket and Screen Gasket for inlet (bung) and screen 9 KIT120SW Switch Lever Kit Switch lever, mounting hardware *KIT120BD not called out in diagram below. 6 5 9 4 2 3 8 7 18

Accessories 3/4 Accessories Description FRHMN075S N075DAU10 807CMK 807CLMK 700F3135 FRH07512 FRH07514 FRH07520 S075H1314 1200KTG9075 3/4 Manual Aluminum Nozzle 3/4 Automatic Nozzle 800 Series Mechanical Meter (Gallons) 800 Series Mechanical Meter (Liters) 3/4 x 12 Hose, UL 3/4 x 12 Hose 3/4 x 14 Hose 3/4 x 20 Hose 3/4 Multi-Plane Swivel 3/4 Filter Head (for use with F18 filters) 1 Accessories Description FRHMN100S N100DAU10 N100DAU13 901CMK4200 901CLMK4200 900CD 900CDP 300F7773 FRH10012 FRH10014 FRH10020 S100H1315 700ACCF7017 1 Manual Aluminum Nozzle 1 Automatic Nozzle 1 Ultra-High Flow Automatic Nozzle 900 Series Mechanical Meter (Gallons) 900 Series Mechanical Meter (Liters) 900 Series Digital Meter (Programmable) 900 Series Digital Meter with Integral Pulsar (Programmable) 1 x 12 Hose, UL 1 x 12 Hose 1 x 14 Hose 1 x 20 Hose 1 Multi-Plane Swivel 1 Filter Head (for use with F40 filters) 900CD N100DAU13 700ACCF7017 19

Safety Testing Approvals The Fill-Rite line of pumps have been safety tested for compliance to the standards set forth by Underwriters Laboratories, ATEX, ANZEx, INMETRO, and lex. Model Series ATEX ANZEx IEx 94/9/EC AS 2380.1 AS 2380.2 AS 1939 IEC 60079-0 IEC 60079-1 FR1200E X X X FR2400E X X X FR4200E X X X FR4400E X X X Certification Date 24-May-12 30-May-12 31-Aug-12 94/9/EC: Equipment and Protective Systems Intended for Use In Potentially Explosive Atmospheres. AS2380.1: Electrical Equipment for Explosive Atmospheres - Explosion - Protection Techniques - Part 1: General Requirements. AS2380.2: Electrical Equipment for Explosive Atmospheres - Explosion - Protection Techniques - Part 2: Flameproof enclosure d. (Class I Group D) AS1939: Degrees of Protection Provided by Enclosures of Electrical Equipment. IEC 60079-0: Explosive Atmospheres - Part 0: Equipment - General Requirements. IEC 60079-0: Explosive Atmospheres - Part 1: Equipment Protection by Flameproof Enclosures d. (Class I Group D) Motor Tag Information The Motor Tag on your Fill-Rite pump contains important technical and performance information. Be certain this label remains affixed to the pump at all times. Date stamp location Visit us on the web at: www.fillrite.com Learn more about Tuthill Corporation and our family of high quality, value minded products at: www.tuthill.com 8825 Aviation Drive Ft. Wayne, IN 46809 1-800-634-2695 20 DC000945-000 Rev 2