Valve monitoring system VDK 200 A S02

Similar documents
Valve testing system VPS 504 for multiple actuators

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Old documentation - Only for your information! Product is not available any more!

Manually operated safety shut-off valve HSAV HSAV/5

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Two-stage safety solenoid valves ZRLE/5, ZRDLE/5

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Pressure switch for gas, GW 500 A4 GW 500 A4/2

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

Two-stage safety solenoid valves ZRD/5, ZRLE/5, ZRDLE/5

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

3 Edition Product brochure GB AGA

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Old documentation - Only for your information! Product is not available anymore!

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Tightness control TC. Product brochure GB Edition 12.10

Special gas range Biogas range

The installation and maintenance of this product must be done under the supervision of an experienced

Commonwealth of Massachusetts Approved Product Approval code G

Combination controls CG 10

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

VE4000 & VE5000 SERIES

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Solenoid actuator MB 7 and butterfly valves BVHM

BGD258 Series BASOTROL CE Approved Class A Gas Valve

RS/M SERIES. Modulating Gas Burners FIRING RATES

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

BGD278 Series BASOTROL CE Approved Gas Valve

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

Typetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Solenoid valves for gas VAS Double solenoid valves VCS

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

Oil - kerosene burner

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Position switches FR series

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

Servo-operated 2/2-way solenoid valves Type EV220A

Type 6213 EV, 6281 EV

Solenoid valves for gas VAS, Double solenoid valves VCS

Flash Point Process Analyzer

Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

E Series CE Approved Intermittent Pilot Ignition Control

Kerosene - oil burner

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

Solenoid valves for gas VAS, Double solenoid valves VCS

Pressure switch and Thermostat Type CAS

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

One-line distributor e.g. VEI-A. One-line aggregate GEI-A

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

Light oil - kerosene burner

AQUASTATS THERMOSTAT APPLICATION CONTENTS PRODUCT HANDBOOK

G76x Direct Spark Ignition Controls

Operating Instructions Pedestrian Turnstile Type MPT 33

Solenoid valves for gas VAS, Double solenoid valves VCS

VTZ variable speed Reciprocating compressors

LK Manifold Shunt VS2

LK Position Switches TECHNICAL DATASHEET.

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

ONE STAGE GAS BURNERS RDBS SERIES

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

Position switches FR series

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Transcription:

Valve monitoring system VDK 200 A S02 8.11 Printed in Germany Edition 11.17 Nr. 214 768 1 6 Technical description The VDK 200 A S02 is the compact valve monitoring system as per EN 1643 for automatic shut-off valves: - Device operates independent of inlet pressure - Test volume 20 l - Setting possible on site - The complete test procedure is defined - Release time: max. 26 s - Tightness or leaks are displayed by an LED - Suitable for TRD systems - Electrical connection at screw terminals via PG 11 cable entry Fields of application Valves according to EN 161 Class A The VDK 200 A S02 may be used with any other valve whose tightness in counter-flow direction excludes by construction a leakage in flow direction. The VDK 200 A S02 is suitable for all DUNGS valves according to EN 161 Class A. For special model for H 2 applications, refer to data sheet 8.12. Suitable for gases of gas families 1, 2, 3 and other neutral, technical burnable gases. Approvals EC type test approval as per EC Gas Appliance Directive: VDK 200 A CE-0085 AQ 0808 EC type test approval as per EC Pressure Equipment Directive: VDK 200 A CE0036 Approvals in other important gas-consuming countries. Special design for the North American market with U L, FM and CSA registration.

VDK 200 A S02 Valve proving system for automatic shut-off valves as per EN 161, Class A Specifications Operating pressure Test volume Pressure increase by motor pump Rated voltage / frequency (admissible voltage range) Power requirements Back-up fuse (provided by customer) Fuse installed in housing cover, replaceable Switching current Observe the starting current of the motor! Degree of protection Ambient temperature Release time Interference time Sensitivity limit Switch-on duration of control Max. number of test cycles Installation position max. 360 mbar (36 kpa) 0,4 l 20,0 l 35-40 mbar 230 V AC -15% to -240 V 6% 50 Hz For further voltages, refer to type overview During pumping time approx. 80 VA, in operation 20 VA 10 A fast-blow fuse or 6.3 A slow-blow fuse Microfuse T 6.3 L 250 V; IEC-127-2/III (DIN 41 662) Operation output Terminal 13: max. 4 A Fault output Terminal 14: max. 1 A IP 40-10 C to 60 C 10 26 s, depending on test volume and inlet pressure 32 ± 3 s 50 dm3/h or 0.1 % of the burner heat load (> 500 kw) The VDK 200 A S02 can always be used with systems with a burner capacity < 500 kw or a test volume < 6 l. If the system has a burner capacity > 500 kw or a test volume > 6 l, the VDK 200 A S02 can be used only if the burner capacity is higher than the minimum burner capacity specified in the diagram. 100 % 15/h. Wait for at least 2 minutes after carrying out more than 3 consecutive test cycles. vertical to horizontal, not upside down Defining the minimum burner capacity: 1. Determine the test volume (see page 5) 2. Test volume --> Inlet pressure curve 3. Inlet pressure curve --> Reading the minimum burner capacity 4. The VDK 200 A S02 can be used if the burner capacity is higher than the read minimum burner capacity. Min. burner capacity [kw] 1500 1400 1300 1200 1100 1000 900 800 700 4 3 VDK 200 A limit values 2 360 mbar 300 mbar 250 mbar 200 mbar 150 mbar 600 1 500 6 8 10 12 14 16 18 20 Test volume [dm3] 2 6

Program flowchart VDK 200 A S02 "TIGHT" VPrüf = 1,0 l pe = 20 mbar VDK 200 A S02 "TIGHT" VPrüf / Test / Prova = 6,0 l pe = 100 mbar VDK 200 A S02 "TIGHT" VPrüf / Test / Prova = 20,0 l pe = 360 mbar Fault signal VDK 200 A S02 "LEAK" t test 0 5 10 15 20 25 30 35 [s] Program flowchart Idle state: Valve V1 and valve V2 are closed. Pressure build-up: The internal motor pump increases the gas pressure in the test section by about 35mbar compared with the pressure arising on the inlet side at valve V1. During the test period (pump period) the integrated differential pressure switch monitors the test section for leaks. When the test pressure is reached, the motor pump switches off (end of test period), and the yellow LED flashes until the contact is released. The release time (max. 26s) is dependent on test volume (max. 20l) and inlet pressure (max. 360mbar). If the test section is leak-tight, the contact is released to the automatic burner control after 26s and the yellow LED comes on. If the test section is leaky or if the pressure rise by 35 mbar is not reached during the test period (max. 26 s), the VDK 200 A S02 switches to fault. The red signal lamp lights as long as the contact is released by the regulator or thermostat (heat request). An automatic restart is performed on short-term voltage failure during the test or in burner mode. Operation: Valve V1 and valve V2 are open, the internal valve of VDK 200 A S02 is closed. 3 6

Dimensions [mm] 106 196 132 Electrical connection VDK 200 A S02 Connection to screw terminals via PG* 11 cable gland (* = heavy-gauge conduit thread). 34 11 142 37 Only use terminals 1, 3, 13 and 14. If you do not observe this instruction, it may result in personal injury or material damage. Made in Germany ø 4.6 for self-pressing screws M5 Typ: VDK 200 A S02 Störung Betrieb Dérangement Fonctionnement Blocco Funzionamento Lockout Run Functional description The VDK 200 A S02 operates according to the pressure build-up principle. The program module starts to function when heat is requested. Test is performed depending on the burner functional procedure: Function principle - Test prior to burner start or - Test during pre-purge time or - Test after burner shut-down The VDK 200 S02 performs a self-test during a switching sequence. Startup 1. Check test section for leaks after assembly. 2. Start test by using temperature regulator and/or restart or by pressing the reset button on VDK 200 A S02. 3.If the test section is tight Depending on the length of the test section and the residual pressure applied, the pumping time can be up to 26 s. The release for the automatic burner control system is granted at the latest after approx. 26s - the yellow signal light illuminates continuously. If the test section is leaky The test pressure is not reached. The motor pump switches off, the red fault lamp lights up. Switch-through to the automatic burner control does not take place. Functional check By opening a screw plug p 2 (p a ) during the test period (pumping time), leakage can be simulated and a function check can take place. Setting The VDK 200 A S02 is preset at the factory. Setting the VDK 200 A S02 is possible on site. Setting is performed at the externally accessible setting screw. Apply varnish to the setting screw after startup. Keep strictly to the instructions. Assembly The VDK 200 A S02 must be connected to the DUNGS single valves (can be mounted on the right or the left) by means of two steel pipes (ø 12 mm). If an exhaust gas valve is installed in the boiler, it must be open at the beginning of the test. In order to prevent functioning and tightness problems, we recommend to use solenoid valves according to EN 161 Class A. The connection lines between VDK 200 A S02 and the valves must withstand mechanical, chemical and thermal loads. 4 6

Using the VDK 200 A S02 at DUNGS individual solenoid valves.../5 We recommend the use of the connection kit, Order No. 231 776, for mounting the VDK 200 A S02 on the valves Rp 1 1/2 to Rp 2 and or/ DN 40 to DN 50. We recommend the use of the connection kit, Order No. 231 777, for mounting the VDK 200 A S02 on the valves DN 65 to DN 150. The max. test volume of 20 l must not be exceeded. V Test = Valve volume V1 outlet V2 inlet Volume of pipeline Determining test volume V Test Determine outlet-side volume of V1. Refer to table for Rp 3/8 to DN 200. Determine inlet-side volume of V2. Refer to table for Rp 3/8 to DN 200. Determine volume of intermediate pipeline section 3. Refer to table for Rp 3/8 to DN 200. V Test = Volume Valve 1 Volume Intermediate pipeline section Volume Valve 2 Determining test volume V Test Rp / DN Valve - Volume [l] V1 outlet V2 inlet Test volume [l] = Volume V1 outlet V2 inlet Pipeline length Pipeline lengths between individual valves L [m] 0,5 m 1,0 m 1,5 m 2,0 m Rp DN Rp DN Rp DN Rp DN Rp DN Rp 3/8 0,01 l 0,06 l 0,11 l 0,16 l 0,21 l Rp 1/2 0,07 l 0,17 l 0,27 l 0,37 l 0,47 l Rp 3/4 (DN 20) 0,12 l 0,27 l 0,42 l 0,57 l 0,72 l Rp 1 (DN 25) 0,20 l 0,45 l 0,70 l 0,95 l 1,20 l Rp 1 1/2 / DN 40 0,50 l 0,70 l 1,10 l 1,35 l 1,70 l 2,00 l 2,20 l 2,65 l 2,80 l 3,30 Rp 2 / DN 50 0,90 l 1,20 l 1,90 l 2,20 l 2,90 l 3,20 l 3,90 l 4,20 l 4,90 l 5,50 l DN 65 2,0 l 3,7 5,30 l 7,00 l 8,60 l DN 80 3,8 6,3 l 8,80 l 11,30 l 13,80 l DN 100 6,5 l 10,5 l 14,40 18,40 l 22,3 l DN 125 12,0 l 18,2 l 24,3 l 30,50 l 36,6 l DN 150 17,5 l 26,5 l 35,2 l 44,10 l 52,9 l DN 200 46,0 l 61,7 l 77,4 l 93,10 l 108,9 l VPS 504 0,1 l V prüf 4,0 l 1 l = 1 dm 3 = 10-3 m 3 VPS 508 1,5 l V prüf 8,0 l VDK 0,4 l V prüf 20,0 l DSLC 1,5 l V prüf 5 6

Valve monitoring system VDK 200 A S02 VDK 200 A S02 type overview / accessories / order details Version Order No. VDK 200 A S02 230 VAC 50 Hz 211 222 VDK 200 A S02 110 VAC 50 Hz 211 224 VDK 200 A S02 240 VAC 50 Hz 211 229 VDK 200 A S02 120 VAC 60 Hz 211 927 Hydrogen version For specifications, refer to datasheet 8.12 Accessories / spare parts Connection kit Rp 1 1/2 - Rp 2 DN 40 - DN 50 231 776 Connection kit DN 65 - DN 150 231 777 Appliance fuse link (5 pieces) 231 780 We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. KG Karl-Dungs-Platz 1 D-73660 Urbach, Germany Telephone 49 (0)7181-804-0 Fax 49 (0)7181-804-166 Postal address Karl Dungs GmbH & Co. KG Postfach 12 29 D-73602 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 6 6