Technical Director INENSUS GMBH. 01 Wind Energy Basics 02 Components & functions of small wind turbines 03 Service and maintenance

Similar documents
Small Wind Energy - International Standards. Small Wind Energy International Standards. Overview

Technical Explanation for Inverters

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Technical Director INENSUS GMBH DEFINITION OF HYBRID POWER SYSTEMS

Christof Deckmyn DEVELOPING AND TESTING POWER CONTROL FOR A WIND POWER STATION MODEL

Wind Energy System.

Operating & Installation Manual

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

Wind Generation and its Grid Conection

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

Wind Turbine Configuration for the Offshore Environment. Simon Watson Loughborough University

GOLDWIND 2.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD) WIND TURBINE

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems

Doubly fed electric machine

K L E I N W I N D K R A F T kleinwind.at

Wind Kids Series Wind Turbine Specification

HM WIND TURBINE. Operation Manual. **Please read the manual carefully before using **

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Modeling, Simulation & Control of Induction Generators Used in Wind Energy Conversion

A starting method of ship electric propulsion permanent magnet synchronous motor

Technical Guide No. 7. Dimensioning of a Drive system

Power Conditioning of Microgrids and Co-Generation Systems

Wind Turbine Generator System. General Specification for HQ2000

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Contents. Review of Electric Circuitd. Preface ;

OPTIMIZATION IN GENERATION FROM A HORIZONTAL AXIS WIND TURBINE VIA BLADE PITCH CONTROL AND STRUCTURE MORPHING

Renewable Energy Systems

LA10 (480 VAC, 3-phase, 60 Hz)

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

NIAGARA REGION WIND FARM PROJECT DESCRIPTION REPORT. Appendix C. Turbine Specifications

Asynchronous generators

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING B.ENG (HONS) ELECTRICAL & ELECTRONIC ENGINEERING EXAMINATION SEMESTER /2017 RENEWABLE ENERGIES

Technology Requirements for Cold and Tropical Wind-Diesel Applications. Chris McKay Product Manager Northwind 100 Ottawa 2009

Low Speed Wind Turbines. Current Applications and Technology Development

Wind turbine aerodynamics, continued (Part 4/4)

ECE1750, Spring Motor Drives and Other

Content. Introduction Products... 4 AVR05TX... 6 AVR1KTX... 7 AVR2TX... 8 AVR3TX Energy Tower AVTO1000/

Unit Protection System for Pumped-Storage Power Stations

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

VENSYS. Vensys 62 The next Generation of Gearless Wind Turbines goes into Production

brighter future take charge of your family s energy future harvest power year-round, night and day with a wind+solar hybrid system from Pika.

Wind-Electric Systems

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Lab Electrical Power Engineering I

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Permanent-magnet synchronous motors


Electrical Machines II. Week 5-6: Induction Motor Construction, theory of operation, rotating magnetic field and equivalent circuit

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278.

Wind Turbine Technical Specifications

Induction Motor Control

DC CIRCUITS ELECTROMAGNETISM

wind turbine system For New Design

Optimization of Total Operating Costs Using Electric Linear Drives

9kW Multi Wind-Lens Turbine Specification (3kW WL turbine x 3 units)

QUESTION BANK SPECIAL ELECTRICAL MACHINES

Variable speed application guidelines

MAJOR SYSTEM FUNCTIONS

National 4 Physics - Electricity and Energy Summary Notes

MSD Concept Generation Created 9/20/11 Edited 9/29/11, 10/3/11, 10/18/11

Electrical Machines -II

POWER-LEADER INSTALLATION AND OPERATOR S MANUAL

Autonomous Mobile Robot Design

Power Control of a PMSG based Wind Turbine System Above Rated Wind Speed

1KW WIND TURBINE. Welcome to the future, and our latest renewable energy products...

Inductive Power Supply (IPS ) for the Transrapid

ing. A. Kragten February 2010 KD 437

Math and Science for Sub-Saharan Africa (MS4SSA)

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

Wind Turbine Guidebook. For HYenergy HY-400, HY-600, HY-1000, HY-2000, HY-3000 Off-grid Models

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

Eastside Invitational Jan 28, 2017 Wind Power Div C - Part 2

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

Advanced Active And Reactive Power Control For Mini Grids

Design and Implementation of a Smart Terrace Energy System

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

Renewable Energy Systems 13

EP4-Platform: E-126 EP4 / E-141 EP4. Arno Hildebrand, Programm Manager EP4 ENERCON Research & Development

Braking Circuit of Small Wind Turbine Using NTC Thermistors under Natural Wind Condition

Chapter 3.2: Electric Motors

Remy HVH250 Application Manual Remy HVH250 Application Manual

Relation Wave Energy Converter GIANT

Green energy conversion

T701 (240 VAC, 1-phase, 60 Hz)

Anakata New Generation Wind turbines 400W-1400W

hofer powertrain GmbH

WM-1000 WIND TURBINE. Operation Manual. **Please read carefully before using it. **

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application

Contents. Prefece. List of Acronyms «xxi. Chapter 1 History of Power Systems 1

Northern Power 100. All turbines capture wind. The Northern Power 100 is designed to do it better.

Guide Vanes for Darrieus Water Turbine in Tidal Current

Solardyne Corporation Renewable Home Power Design Guide Call

RW-30kW variable pitch wind turbine

Some admonitions you must know before using DS600

Excel 10 (240 VAC, 1-phase, 60 Hz)

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

Transcription:

1 Energy - Basics & Technology 2 AGENDA 01 Energy Basics 02 Components & functions of small wind turbines 03 Service and maintenance 1

3 Energy source The sun Solar Energy Direct usage Solar energy Photovoltaic Solar collector Indirect usage Surrounding heat Passive heat usage with heat pumps Different heating of air mass wind energy power plants Ocean waves/ streams Wave energy Growth of plant Biomass fire fire Evaporation of water, rainfall on higher areas Hydropower Storage power station Running water 5 Comparison wind and hydro power Form of energy Formula energy Kinetic energy of the air in motion Hydro power Potential energy of the water Density of working fluid Energy density low high 1.225 kg/m³ 1000 kg/m³ relationship quadratic linear 2

6 Rotor operating principle (1) No production Rotor 4 m/s 4 m/s 7 Rotor operating principle (2) Power production Rotor 1/3 * 4 m/s 4 m/s 3

8 Rotor operating principle (3) Energy of the air in motion kinetic energy P wind = = time 1 2 m t v 2 P wind P wind 1 = ρ A v 2 ( ) 2 1 = ρ A v 2 3 v Power depends on 1. Air density 2. Rotor surface 3. velocity (3 rd power) 9 Rotor operating principle (4) Limits of energy conversion Rotor Albert Betz: energie und ihre Ausnutzung durch mühlen (1926) Maximum utilization for lift-device rotors if v = 1 v 2 3 degree of harvesting 1 v 1 v 2 = 16 27 c P, Betz 59% 4

10 Rotor operating principle (4a) Background Betz s Law assumption: massflow rotor wind : power : v m& P = = = ρ 1 4 v 1 + v 2 2 v 1 + v A 2 2 = 1 m& v 2 ρ 2 2 ( v ) 2 ( + v ) ( v v ) Av 1 power : P = ρ 0 A v 2 1 2 1 3 1 1 2 2 2 11 Rotor operating principle (4b) Background Betz s Law P_/P_0 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 v_2/v_1 5

12 Technical usage system losses P WEC 59% = P wind cp, Betz η η 70 90% rotor 80 90% η generator 90 95% gearbox η 90 99% electronics Physically usable Aerodynamic and mechanic losses Electrical losses 13 Rotor types (1) drag devices Operating principle rotor blade evades the wind dragforce 2 = c 2 Av - Low rotor speed - Low efficiency + simple rotor blades + much torque at stand still Hau: kraftanlagen S ρ 6

14 Rotor types (2) lift devices lift force - Low torque at stand still - Complex and expensive rotor blades + high speed + good efficiency Rotor blade drag force 15 Rotor types (3) Savonius Rotor Also with more blades Rotor blades twisted or two rotors in one + good start-up behaviour + low noise (low rotor speed) + much torque from standstill - Expensive geared generator - Low efficiency 7

17 Rotor types (4) Darrieus Rotor Lift force Lift force + low noise (low rotor speed) + no direction alignment necessary - More expensive generator - Expensive rotor construction - Self start-up only with more then 2 blades Alternatively: combination with Savonius or motor start-up - High inertia - Inefficient rotor surface usage 18 Rotor types (4a) Darrieus Rotor 8

19 Rotor types (4b) Darrieus Rotor 20 Rotor types (5) 3bladed horizontal axis + lightweight construction + simple generator connection + good usage of rotor surface + high speed generator - A bit more noise - direction alignment necessary - Low torque at stand still 9

21 Rotor types (5a) 3bladed horizontal axis 22 Rotor types (5b) 3bladed horizontal axis 10

23 Rotor characteristics (1) tip speed ratio λ = blade tip speed wind speed Drag device λ < 1 Lift device λ > 1 Slow running λ < 2.5 Fast running λ > 2.5 24 Rotor characteristics (2) comparison of rotor types 0,5 coefficient of power cp 0,4 0,3 0,2 0,1 0 1 2 3 4 5 6 7 8 9 tip speed ratio 11

25 Rotor characteristics (3) synthesis to power curve Power curve Rotor power [W] v=10 m/s v=12 m/s v=14 m/s v=8 m/s v=6 m/s v=4 m/s 0 2 4 6 8 10 12 14 16 18 Rotor speed [rpm] [m/s] 26 Rotor characteristics (4) power curve Rated power power 3 ~v P P WEC Power limitation Technical losses Most frequent wind speeds 0 2 4 6 8 10 12 14 16 18 speed [m/s] 12

27 What is my wind speed? Beaufort number v [m/s] v [km/h] Impact 1 < 1,6 < 5 Smoke drift indicates wind direction 2 < 3,4 < 11 Leaves rustle 3 < 5,5 < 19 Small twigs constantly moving 4 < 8,0 < 28 Dust and loose paper raised 5 < 10,8 < 38 Branches of moderate size move 6 < 13,9 < 49 Large branches in motion 7 < 17,2 < 61 Whole trees in motion 8 < 20,8 < 74 Some twigs broken from trees 9 < 24,5 < 88 Some branches break off trees 10 < 28,5 < 102 Trees are broken off or uprooted 11 < 32,7 < 117 Widespread damage to vegetation 12 > 32,7 > 117 Very widespread damage to vegetation 28 Annual average wind speed? frequency 30% 25% 20% 15% 10% 5% v=10m/s v=7,5m/s v=5m/s v=2,5m/s p [W/m²] 12000 10000 8000 6000 4000 2000 specific power[w/m²] 0% 0 0 5 10 15 20 25 wind speed [m/s] 13

29 Direction alignment Needed for plant with horizontal axis Most common technical solutions: 1. vane Rotor in front of the mast (upwind) 2. Rotor itself behind the mast (downwind) Electrical azimuth drive for rated power > 10kW Small side-rotor Problem Too small vanes not effective Airflow on downwind rotor disturbed by the mast 30 Limitation of rotor power (1) reducing the active rotor surface (furling) Rotor a 1. Lateral turning out of the wind 2. Vertical turning (helicopter position) Depending on rotor thrust Eccentric bearing Restoring force/device needed End stop and damping needed Problems Centrifugal forces delay furling Higher rotor speeds extremely slow down function Only coarse control 14

31 Limitation of rotor power (2) reducing the active rotor surface Rotor 1. Bending of rotor blades, restoring through own elastic force 2. More seldom with hinges and springs Only suitable for downwindrotors Active principle of an umbrella Faster as furling, bit better power control In some systems complicated mechanics 32 Limitation of rotor power (3) stall effect speed > maximum permissible wind speed: increasing of load on rotor -> slowing down of rotor speed Rotor blades are twisted along their axis and allow gradual stall from too steep angle of resulting wind speed vector Wikipedia Problem Generator needs additional reserve power Rotor blades need more careful design effort Loss of load or failure of electrical system causes failure of stall braking 15

33 Limitation of rotor power (4) active blade angle control pitch Active blade angle control Small wind turbines mostly use mechanical systems with centrifugal force depending on rotor speed with springs In some systems also in combination with rotor thrust Problem Mostly too expensive for small wind turbines Complicated mechanics Continuous control needed Lot of effort needed to fulfil safety requirements 34 Generator (1) Requirements & characteristics Extremely low startup- / cogging torque High efficiency at different speeds High torque in short-circuit (if generator part of the safety system) Low maintenance bearing Brushless construction Bearings capable to carry forces and weight from the rotor Stiff characteristic if active electronic power converter or soft characteristic if battery charging system Each generator can only generator AC-current, DC current from rectifier Only 3 phases allow constant torque and Wikipedia power per rotation Frequency of AC current proportional to rotor speed 16

35 Generator (2) Synchronous, salient-pole Wikipedia 36 Generator (3) Synchronous, non-salient pole Wikipedia 17

37 Generator (4) Synchronous, salient-pole with slip rings Wikipedia 38 Generator (5) winding connection ings connected in star or delta ings with several connections Connected in parallel or series Higher number of poles for higher frequency at lower RPM P = 1 : 50Hz @ 3000 RPM P = 3 : 50Hz @ 1000 RPM P = 5 : 50Hz @ 600 RPM P = 10 : 50Hz @ 300 RPM 18

39 Synchronous generator (1) single phase model U R X U P (n) No load voltage proportional to rotor speed n Loaded generator: Ohm losses (heat) from winding resistance with voltage drop Additional voltage drop from synchronous reactance X depending on frequency = rotor speed U P (n) defined by the magnetic circuitry Reaches a saturation level R and X defined by the winding and the air gap 40 Synchronous generator (2) synchronous permanently excited 3phase current Continuous power delivery Efficient energy transmission using 3 wires (enables long distances, saves additional return conductor for 1phase AC or DC) Robust and cheap generator design Permanently excited Generator braking capability at loss of external power supply No slip rings for excitation current -> no wearing parts Cogging torque at start-up may be problematic Rare metals for high power magnets getting rare and costly Magnets can demagnetize if heated above their Curie- Temperature (150 to 200 C) 19

41 Synchronous generator (3) synchronous permanently excited Idle voltage and frequency are proportional to rotor speed variable voltage at different wind speeds Variable frequency not problematic, rectification for further usage Adaptation of the load according to voltage or frequency required for optimum efficiency Voltage has a certain temperature dependency (±10%) 42 700 Synchronous generator (4) measured open circuit voltage (example) Idle voltage AC and DC [V] 600 500 400 300 200 100 V_AC V_DC y = 1,81x y = 1,34x 0 0 50 100 150 200 250 300 350 Generator speed [rpm] 20

43 Gearbox Adaptation of relatively low rotor speed to generator speed Additional effort, allows smaller generator Problem Oil change / regular inspection of fill level Additional vibration from meshing Higher start-up-torque from stand still Start-up-behaviour depending on oil temperature 44 Brake Needed depending on safety concept if generator fails For stopping the rotor completely Different concepts operated by centrifugal force Operated by hydraulics / cable Electrically kept open -> stops automatically on grid loss Bi-stable electrically switched brake Not restored automatically after severe errors 21

45 Safety and control systems Rotor speed monitoring Generator monitoring Manual shutdown Emergency stopping Detection of vibration as result of unbalance or ice building up 46 Systems for battery charging (1) overview 3~ Main switch Charge controller inverter DC consumers rectifier Charge controller Battery 22

47 Systems for battery charging (2) operational principle G 3~ Generator rectifier battery 48 Systems for battery charging (3) summary Generator delivers 3~ AC current Variable frequency and variable voltage Generator in idle mode at low rotor speeds As soon as rectified generator voltage is higher then batter voltage, current flows to the battery Battery limits the rise of generator voltage Sufficient wind enables speeding up of the rotor, more current flows to the battery Generator operates like a bike dynamo, voltage is independent of generator speed Good loading of the rotor according to actual wind speed Battery is charged Overcharge damages the battery, hence wind charge controllers are mostly overcharge protectors dissipating surplus power Each rated battery voltage needs special generator winding and charge controller 23

49 Systems for battery charging (4) fields of operation Rural electrification Holiday flats caravans boats Weather stations Traffic control Research stations Pumping stations Base transceiver stations 50 Polyphase rectification Wikipedia 24

51 Simple battery charger (1) schematic 52 Simple battery charger (2) photo 25

53 Systems for feeding to the grid (1) overview source: www.sieb-meyer.de 1. Small wind turbine 2. Overvoltage protection 3. Disconnecting point 4. Grid-tie inverter 5. Ballast resistor 6. Disconnecting point 7. Grid connection 54 Systems for feeding to the grid (2) electric energy conversion source: www.sieb-meyer.de 26

55 Systems for feeding to the grid (3) summary Generator produces 3~ current Variable frequency and variable voltage AC current rectified Supply of the inverter at its minimum input voltage Feeding to the grid a.too low rectified generator voltage boosted to about 400V DC and inverted to 230V, 50Hz b.inversion of rectified generator voltage, transformation to higher grid voltage via transformer Permanent monitoring of grid parameters according to EN 50438 / VDE 0126, automatic disconnection required Alternative loading of the generator during grid monitoring before feeding to the grid and while grid errors required to prevent speeding up of the rotor 56 Systems for feeding to the grid (4) fields of operation Self supply Feeding to the house electrical system Energy consumption with the existing AC appliances Coincidence of generation and consumption is low Only operating of variable power consumers (mostly heating) can absorb surplus power All surplus power not consumed flows back to the grid without payment (normal electricity meters) Feeding to the grid according to various renewable energy legislation Separate electricity meter required Payment of the energy produced Additional costs for separate meter and annual metering costs Operation in isolated networks Off-grid system with battery, inverter, etc. only economical if no public utility available 27

57 Variable voltage generator constant grid voltage boost converter Wikipedia 58 Systems for water pumping Configuration Dray devices or western windmills directly drive piston pumps, simple system but relatively low overall efficiency Improvements in combination with highly efficient inverter controlled electric pumps with or without battery storage By-passing of the electricity storage problem by means of storing the pumped water 28

59 Systems for heating Overview Electrical heating Air heating Hot water production with electrical heating cartridges Problem: heat absorption capacity of water in heating systems is limited, rotor must shutdown before water starts boiling Direct connection of a heating resistor to the generator not possible, rotor will not start-up at all Electronic power controller needed Direct heat generation With a water brake instead of an electric generator Heating circuit with flow line and return line to/from the wind turbine Anti-freeze protection needed 60 Mast (1) Mechanical loads Load on the top of the mast from rotor thrust Maximum value for conventional rotors (EN 61400-2) Weight of the nacelle negligible (except erection) Resonance from generator and rotor blades For small horizontal axis wind turbines with 3 blades not problematic Free standing masts more susceptible than guyed masts Very strong induced force from vertical axis rotors Mostly not included in the scope of delivery for very small wind turbines Knowledge of the soil conditions 29

61 Mast (2) Overview Materials Steel Wood Concrete Design Free standing tubular Free standing lattice Guyed tube/lattice Foundation On/in ground on buildings (induced vibration!!!!) Erection With tilt up tower Several kinds of self erection With crane 62 Mast (3) Erection with tilt-up tower 30

63 Service and maintenance Small wind turbines are usually relatively maintenance free, but: Operator has to be permanently aware of risks Stop wind turbine before exceptionally high wind speeds Regularly check: Twisted cables? Safety functions operational? Screws properly fixed? Bearings OK? Different noise from damaged or dirty rotor blades? Vibration? Oil leaks?... 64 CONTACT INENSUS GmbH Am Stollen 19 D 38640 Goslar Germany www.inensus.com Tel +49 (5321) 38271-0 Fax +49 (5321) 38271-99 INENSUS West Africa S.A.R.L. 10, Avenue Faidherbe, B.P. 397 Dakar Sénégal 31