Electronic Flow Monitor for liquids

Similar documents
Air Flow Controller M1compact Type-Summary FKM 130

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Compressed Air-Supply Meter

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

SP/SF Series Flow Switches

JUMO MIDAS S05 Pressure transmitter Type

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Servo solenoid valves with on-board electronics (OBE)

JUMO MIDAS Pressure transmitter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Special Purpose Transmitters

Screw-in resistance thermometers with plug connector

Paddle-wheel flow controller with optical principle for On/Off control

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Electronic Pressure Switch EDS 3000

Proportional pressure reducing valve, pilot operated

Pressure transmitter PASCAL CV4

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with positive overlap and on-board electronics

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Operating instructions Flow monitors SI / / 2010

Heating chamber with mechanical convection

JUMO ecotrans Lf 01/02

J TS 7090 Thyristor power switch

Climate chamber with illumination

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Industrial Pressure Transmitters

Paddle-wheel flow controller for On/Off control

Heating chamber with mechanical convection

Differential-Pressure Flow Meter

Servo solenoid valves with on-board electronics (OBE)

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

Differential pressure gauges with Bourdon tube

Operating Instruction for Flowmonitor. Model: DF-WM

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Electronic Temperature Sensor ETS 300

Climate chambers with illumination

Proportional pressure relief valve, pilot operated

Electric amplifiers for proportional valves

INSTRUMENTATION & CONTROL

CTE7000 / CTU7000 Series Miniature pressure transmitters

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Electromagnetic Flow Monitor magphant

Proportional pressure reducing valve, pilot operated, with inductive position transducer

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Operating instructions Flow monitors SI5000 SI / / 2007

Operating Instruction for Electronic Pressure Switch. Model: PDD

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

,

Pressure transmitter COMPACT ECOnomic

Diaphragm Valve, Plastic

SPT- I / U PRESSURE TRANSMITTER for general applications

Direct immersion resistance thermometer

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

RDN4 - RDN8 Differential pressure switch

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Heating chamber with mechanical convection

Proportional pressure relief valve

Pressure Transmitter JUMO dtrans p30 Type

Design and applications

better measurement Simply a question of

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Paddle-wheel flow controller for On/Off control

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

CONTROLLERS & SPECIAL VALVES

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Differential pressure transmitter PASCAL Ci4 Delta P

More Precision. mainsensor Magneto-inductive displacement sensor

Servo solenoid valves with on-board electronics (OBE)

SIKA Flow Switches -1-

Proportional flow control valve, with inductive position transducer

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

SIKA Flow Switches -1-

Heating chamber with mechanical convection

Pressure transducer DMU 01K Compact version

Electronic Pressure Switches

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Page 1/6. Temperature sensor baelz 61 with questionnaire for inquiries on page 5 DS 61, 251

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitters for industrial applications Type MBS 4510

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Pressure transmitter for elevated media temperatures

Pressure sensor for liquid and gaseous media QBE620-P...

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Insertion magnetic inductive flowmeter

Transcription:

Electronic Flow Monitor for liquids Flow Pressure Level Temperature measurement monitoring control Intelligent temperature compensation with measuring range adjustment Easy to fit No moving parts No mechanical wear Negligible pressure loss KOBOLD Messring GmbH Nordring 22-24 D-6579 Hofheim/Taunus Box 265 77 26 Ludvika Telefon 0240-50 09 Fax 0240-6 08

Method of operation The model KAL-... electronic flow monitor continuously monitors liquid media. It is suited for securely monitoring flows with minimum pressure loss. Sensitivity to soiling is significantly reduced by means of a single-part sensor. Theory of operation The operation of the model KAL-... electronic flow monitor is based on the calorimetric principle. The end face of the sensor is heated to a few degrees above the temperature of the flow medium. When the medium flows, the heat generated in the sensor is transferred to the medium, ie, the sensor is cooled. The cooling procedure is an accurate measure of the flow velocity. The sensor signal is compared with the reference data stored in a microcontroller. An alarm signal and/or an analog signal (4-20 ma) that is proportional to the flow velocity is output if the actual flow velocity deviates from the desired flow velocity. The microcontroller allows the flow indicator to be easily calibrated and the temperature to be compensated. Temperature compensation The temperature of the KOBOLD flow monitor is compensated with a microcontroller. All data required for temperature compensation are stored in EEPROMS, and are maintained for at least 0 years after power failure. The instruments may be easily adjusted by the customer to suit process conditions. The measured flow rate is compared with the zero-point adjustment values stored in the EEPROM and the stored characteristic curves. The data is processed by the microcontroller and controls the alarm signal or the analog output. The sensor switching point is absolutely consistent, as the sensors have been adapted to suit the process data. Drift of operating point with respect to temperature 2 Schaltpunktveränderung über Temperatur Features Optimal temperature compensation Intelligent switching Measuring range adjustment No moving parts Easy to fit and put into service Minimum pressure loss Easy to use Switch point (m/s) KAL-... with compensation Standard without compensation Measuring and switching ranges 0 20 0 40 50 60 70 80 Nominal size (mm) Appr. meas. range l/min. water Nominal size (mm) Appr. meas. range l/min. water 8 0,2-6,0 40,0-50 0 0,9-9,4 50 4,7-25 5 0,42-2,8 60 6,8-40 20 0,75-7,7 80 2,0-60 25,8-59,0 00 8,8-942 0,7-84,8 50 42,4-220 Important: The flow velocity has been converted for the pipe nominal size for the specified measuring ranges. Please note that the flow velocity approaches zero in the pipeline in the direction of the wall. Depending on the pipe nominal size, depth of engagement of the sensor, and flow profile, the deviations from the specified flow rates can be of considerable magnitude. Temperature ( ) Range of models ompact devices KAL-A... Flow meter with analog output (4-20 ma) KAL-AK Flow meter /-monitor with analog output (4-20 ma) and alarm signal (PNP/NPN, make contact) KAL-K... Flow indicator alarm signal (PNP/NPN, N/O contact) Separate version KAL-.. Sensor KAL-E.. Electronics with relay contact for flow monitoring KAL-E2.. Electonics with relay contact and trend indication for flow monitoring KAL-E.. Electronics with relay contact for flow and temperature monitoring Trend indication for flow monitoring

Technical details: Electronics: Power supply: 24 VD ±0 % 0 VD ± 0 %, 0, 20 VA ± 20 %, Power input: max. 4,5 (typically,2 W) max.,6 W for 24 VD Ambient temperature: - 20... +60 Temperature of medium: -20... +80 IP compatibility: max. 40 non-operating Max. pressure: 00 bar Time delay before availability: max. 2 s Switching range: approx. 4 cm/s to 200 cm/s Temperature gradient: unlimited Response time: typically 5,6...2 s upon request: 2-5,6 s (KAL-KS...) Flow rate indication: trend indication with 8- LED s Switch point adjustment: with potentiometer, optical indication on LED chain with flashing LED Output indicator: LED, red= alarm, green= flow OK Switching output: 24 VD version: semiconductor PNP/NPN switchable, max. 400 ma, short-circuit proof 0 VD version: relay max. 0,2 A /0 VD 0 VA, 20 VA version: relay max. 5 A N/O function: actual value setpoint value;(standard setting: green LED is energized) output switched through N/ function: available as option Protection type: IP 65 ase material: polyamide Electrical connection 2 KAL-K... 24 VD Output Ground +24 VD KAL-K..., with cable connection 0 VD, 0 VA, 20 VA white make contact () black make contact (2) brown A/D supply ()* blue A/D supply (4)* green/yellow PE conductor (with A only)* *Voltage according to nameplate Order details Order numbers for materials onnection.40.405.457 Type of contact G /4 KAL K08 - KAL K408* Electrical connection Supply G /2 KAL K5 KAL K25 KAL K45 0=20 VA G /4 KAL K20 - KAL K420* S=N/O contact PG=PG,5 =0 VA M 2x KAL K02 - - (NPN/PNP = 24 VA /4 NPT KAL K508 - KAL K5408* switchable) ST=connector 6=0 VD /2 NPT KAL K55 - KAL K545 M2x /4 NPT KAL K520 - KAL K5420* O=N/ contact Tri clamp, DIN 2676 - - KAL K4440 (optional) Example of order: KAL-K 520 S PG *Stainless steel hexagon.40

Technical details Sensor: Material case: see order details cable: PV, option (KAL-...HT): silicone cable gland: Brass nickel-plated; PG 7 able: 2 x 0,56 mm 2, length = 2 m max. line length 00 m Switching range: 4 cm/s to 200 cm/s Temperature of medium:-20 to +80, (KAL-...HT) option: 0 to +20 Ambient temperature:-20 to +80, KAL-...HT: -20 to +20 Max. pressure: 00 bar (KAL-2 and KAL-40: 25bar) Protection type (DIN 40050): IP 68 Important! For cable lengths >0m, the client can lucrease the absolute switching accuracy manually by adjustment (cable resistance must be considered). (See ompensation Temperature). Model KAL-E(H)..electronics Power input: max.,6 W Switching capacity: max. 250 V, max. A Switch point adjustment: with potentiometer Switching function: relay picks up with flow (terminals 9 & 0 closed) (KAL-E..) option: relay picks up if temperature falls below setpoint, LED is energized (terminals 2 & closed) Output: relay with changeover contact Output indicator: with LED Time delay before availability: max. 2 s Temperature range: - 20...+80 Accuracy: temperature limit value ± 2 % Reproducibility: approx. 2 % Response time: typically 5... 2 sec DIN rail fitting: DIN EN 50022 und DIN 46277 Protection type: case: IP 40, terminals: IP 20 ase: polycarbonate, L 75 x W 55 x H 0 mm Sensor output: short-circuit proof, cable break is detected as flow stoppage Power failure: calibration data are stored for at least 0 years without battery power. Sensor order details Order numbers Sensor for coupling fitting Sensor with pipe fitting onnection.40.457 Brass fitting/ Sensor.40 Fitting.40/ Sensor.40 G /4 KAL 08 KAL 408 KAL 08 KAL 208 G /2 KAL 5 KAL 45 KAL 5 KAL 25 Electrical onnection G /4 KAL 20 KAL 420 KAL 20 KAL 220 00= G - - KAL 25 KAL 225 2 m PV-cable G /4 - - KAL 2 KAL 22 HT= G /2 - - KAL 40 KAL 240 2 m silicone cable M 2x KAL 02 - - - ST= /4 NPT KAL 508 KAL 5408 - - M2xconnector /2 NPT KAL 55 KAL 545 - - /4 NPT KAL 520 KAL 5420 - - Order details electronics (KAL-E..standard, KAL-EH..high temperature version) Supply voltage Field of application Example of order: KAL 08 HT Flow trend indication Temperature monitoring 24 VD 24 VA 0 VA Flow - - KAL E(H) KAL E(H)2 KAL E(H) Flow 8-LEDs - KAL E(H)2 KAL E(H)22 KAL E(H)2 Flow/ 8-LEDs -20..+80 0 KAL E KAL E2 KAL E Temperature 0..+20 0 KAL H KAL H2 KAL H 20 VA KAL E(H)0 KAL E(H)20 KAL E0 KAL H0

Technical details Power supply: 24 VD ± 20 % Power input: max.,6 W (typically,2 W) Ambient temperature: - 20 to +60 Temperature of medium: -20... +80 Max. pressure: 00 bar Time delay before availibility: max. 2 s Measuring range: approx. 4 cm/s to 200 cm/s Temperature gradient: unlimited Response time: 5,6...2 s Accuracy: ± 0 % of measured value Reproducibility: ± % of measured value Signal output: 4-20 ma Flow rate indication: Trend indication with 8- LED s Protection type: IP 65 ase material: glass-fibre-reinforced polyamide For KAL-AK...only Switching function: N/O contact Switch point adjustment: with potentiometer, optical indication on LED chain with flashing LED Output indicator: LED, red= alarm, green= flow OK Switching output: semiconductor, PNP/NPN switchable, max. 400 ma, short-circuit proof Electrical connection KAL-A... 4...20 ma 2 +24 VD Ground 2 4 KAL-AK... 4...20 ma +24 VD Ground PNP/NPN-switch Order details Order numbers for materials Output/contact onnection.40.405.457 Electrical connection G /4 KAL A08A4 - KAL A408A4* G /2 KAL A5A4 KAL A25A4 KAL A45A4 4-20 ma/ G /4 KAL A20A4 - KAL A420A4* PG=PG,5 without contact M 2x KAL A02A4 - - /4 NPT KAL A508A4 - KAL A5408A4* ST=plug /2 NPT KAL A55A4 - KAL A545A4 M2x /4 NPT /2 Tri clamp, DIN 2676 G /4 G /2 KAL A520A4 - KAL A5420A4* - - KAL A4440A4 KAL AK08AS - KAL AK408AS* KAL AK5AS KAL AK25AS KAL AK45AS 4-20 ma/ G /4 KAL AK20AS - KAL A420AS* PG=PG,5 N/O contact M 2x KAL AK02AS - - NPN/PNP /4 NPT KAL AK508AS - KAL AK5408AS* ST=plug switchable /2 NPT KAL AK55AS - KAL AK545AS M2x /4 NPT /2 Tri clamp, DIN 2676 KAL AK520AS - KAL AK5420AS* - - KAL AK4440AS Example of order: KAL-A08A4PG *Stainless steel hexagon.40

Dimensions KAL-K..., KAL-A(K)... A (mm) (mm) D (mm) G /4 26 6 G /2 40 0 D G /4 4 A M 2x 2 /4 NPT 6 6 approx. 70 /2 NPT 27 0 B=SW 4 /4 NPT 26 KAL-...sensor A (mm) B (mm) D (mm) M 2x HEX 9 2 4 G /4 HEX 9 26 4 G /2 HEX 27 4 58 B D G /4 HEX 2 4 58 A KAL-...with pipe fitting A B (mm) D (mm) G /4 HEX 27 0 50 G /2 HEX 27 0 50 G /4 HEX 2 5 52 G HEX 9 5 56 E (mm) 8 8 82,5 85 E L=2000 +/- 20 SW 0 60 +0 G /4 HEX 46 5 50 G /2 HEX 55 5 50 92,5 90 A D B