DeltaV SIS TM Auxiliary Components

Similar documents
DeltaV SIS TMAuxiliary Components

Monitoring Health of External Solenoid Valve (SOV) with FIELDVUE DVC6200 SIS Digital Valve Controllers

Bettis GH-Series Pneumatic Spring-Return Actuator Torque Chart Imperial

Innovation in actuation.

Bettis GC01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Metric

Bettis G01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Imperial

Bettis TEC2 Electric Actuator with Model 500 Quick-Start Guide. Quick-Start Guide E2K Rev. 2 October 2017

Power controlled LPU system

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

EIM TEC2 Electric Actuator with Model 500 Quick-Start Guide

Operating Instructions M3 and M3HW Jackscrew Manual Override. Service Instructions Rev. D October 2014

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

CBA-Series Pneumatic Dimension Data Metric

Type 289RC Exhaust Booster

SLAM-SHUT VALVE. Type OSE

FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

Electrical: Valve monitoring and control circuits

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers

Programmable Logic Controller. Mat Nor Mohamad

Coriolis Flowmeter with Model 1700 or Model 2700 Transmitter

AMS ValveLink SNAP-ON Applications

Shafer Poppet Block Control

Roxar 2 Mechanical Access Fitting System Pressure ratings up to 6,000 psi/420 bar or 10,000 psi/690 bar 1)

4CR SERIES MOTOR STARTING RELAY All Position, Current-Type

Endurance TM Conductivity Sensors

Type 310A-32A Pressure Reducing Regulator

PowerCommand iwatch Wireless

ValveLink SNAP-ON Application

Logix 3800 Digital Positioner

Roxar 2 Hydraulic Access Fitting System Pressure ratings up to 6,000 psi/420 bar or 10,000 psi/690 bar

Logix 3800 Digital Positioner

True Fail-Safe Technology and Precision Control Meet Emergency Shutdown and Demanding Process Applications

Shafer RV-Series Rotary Vane Valve Actuators

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Roxar 2 Mechanical Access Fitting System Pressure ratings up to 6,000 psi/420 bar or 10,000 psi/690 bar 1)

Disassembly and Reassembly for WG Series Worm Gear Operator. User Instructions Part Number: XXXXXX, Rev. 0 Release: February 2017

Triple offset technology for lower pressures.

Bettis Nuclear Series Actuators. Operation and Maintenance Manual VA Rev. E June 2014

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Market Briefing: Mergers & Acquisitions World, Region, & Country

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Kämmer Multi-Z Severe Service Valves

Shafer SH Series Actuator. Service Manual SHSM Rev. 1 September 2016

Transfer switch GTEC open or delayed transition

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Market Briefing: Mergers & Acquisitions World, Region, & Country

Transfer switch OTEC open or delayed transition

Pressure control solutions for your industry. Aerospace & Defense

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

HIPPS (High Integrity Pressure Protection System)

RAP R10: Air Relay Valve Service and Adjustment ARV-69626/ /05/11. Air Relay Valve Service and Adjustment

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

HPUs Hydraulic Power Units

Bettis RGS Q-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet April 2016 RGS Rev.

Tissue Machine Bearing Failure and PeakVue Problem Resolution

Model 788DVC DIGITAL CONTROL VALVES

SAN10B ( <00>)

Kämmer Series Low Flow Valves

Electronic Limit Switch Type

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Installation, Operation and Maintenance Manual E Rev. D September Bettis Pneumatic Rotary Valve Actuators

Emech DIGITAL CONTROL VALVES

ISC Series Innovative Standard Cartridge Seals

Actuator Control Manual

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Fisher 377 Trip Valve

Electronic Circuit Breaker ESS20

Aldi V4 & V V1.1 5/23/2014

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

DRAFT. Installation, Operation and Maintenance Instructions for Emerson KBG-V Series

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

Two Channel Remote Shutdown Device

TOP SMART intelligent position monitor:

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Phase Modular Finally the benefits of Modular ups are for all

ONTRAC WIRE MESH CABLE TRAY SYSTEM

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Fisher 377 Trip Valve

Kämmer Series Low Flow Valve

1 Terminal Block A-22

engineered to order solutions

OBSOLETE DOCUMENT. 167D Series Switching Valves. Bulletin 71.7:167D. Introduction. Features

Electronic Circuit Breaker ESS20-0..

BETTIS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS FOR PNEUMATIC ROTARY VALVE ACTUATORS

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

Components for EEx e Panels

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

ENGINEERED TO ORDER SOLUTIONS

Complete Power Systems. Accountability for Every Aspect of Onsite Power Delivery

ANDERSON GREENWOOD M25/M25A/M25B/M251/M251B MANIFOLDS

POWER STRIPS - INTERNATIONAL

Installation, Operation and Maintenance Manual HP/DHV Rev. 1 November Shafer Hand Pump-Double Holding Valve

Remote Monitoring System

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Transcription:

January 2013 Page 1 DeltaV SIS TM Auxiliary Components Pair the DTA Inverting module or the ETA Direct module with an Auxiliary Relay Diode module to achieve additional functionality. Enables diagnostics of field wiring all the way to a high-current discrete end device Monitors that the relay changed state correctly Enables de-energize-to-actuate applications, even with higher current ratings Enables energize-to-actuate applications with current ratings above 500 ma Introduction In most cases, DeltaV SIS system will connect to either 4 20 ma analog signal devices or discrete I/O devices rated at up to 500 ma per channel. Almost all the outputs will be De-energize-to-Trip. However, there will be some output signals that require higher currents and some devices, mainly in fire and gas applications, that require energize-to-trip functionality. For applications that simply need high current DeltaV offers the Auxiliary Relay Energize to Actuate (ETA Direct) module. For applications where the current to the final device needs to be switched on when the system trips, there is the Auxiliary Relay De-energize to Actuate (Inverting), or DTA-Inverting relay. Either of these relay modules, paired with the Auxiliary Relay Diode module, allows DeltaV SIS platform to meet higher-current discrete output requirements while maintaining its field wiring monitoring and ensuring that the relay changes states correctly. www.deltavsis.com

January 2013 Page 2 Benefits Enables energize-to-trip applications including line monitoring to the final device and higher current ratings. Some applications, especially in fire and gas, require that the output of a safety loop be energized when a hazardous situation occurs. An example is a motor starter on a fire water pump. DeltaV SIS system has a de-energize-to-trip design it turns off its outputs when there is a safety demand. Our De-Energize to Actuate-Inverting Relay (DTA-Inverting) inverts the output of the logic solver. It sends power to the field device when the logic solver output is switched off. This enables DeltaV SIS system to be used in energize-to-trip applications. Enables enhanced diagnostics on higher-current discrete outputs. Many safety systems monitor the field wiring from their I/O modules. However, if the I/O channel is connected to a relay, then the monitoring likely only extends as far as the relay in the cabinet. Any wiring failure in the field will go un-noticed until the system is manually tested or fails on demand. These auxiliary components extend DeltaV SIS automatic testing of field wiring past the interposing relay. The majority of SIS applications are de-energize-to-trip. If a de-energize-to-trip output requires more current than the DeltaV SIS Logic Solver can provide on a single channel then we use our Energize to Actuate (ETA) relay to switch off the output when the logic solver output is de-energized, and extend line-monitoring diagnostics to the end device. Auxiliary Relay De-Energize to Actuate (DTA-Inverting) The DTA-Inverting relay module has a connection to a single discrete input and a single discrete output channel on a Logic Solver and a connection to a dual 24 V DC power supply. Two field terminals are used to connect to the diode module that is located next to the field actuator. The DTA-Inverting relay module energizes the field device when the Discrete Out is turned off. The DTA-Inverting relay module is paired with the Relay Diode module to enable the monitoring of the field wiring and the status of the relay. A switch on the Relay Diode module is used to change between energize to actuate and de-energize to actuate. The Auxiliary Relay DTA-Inverting module s LED shows the state of the relay coil and that power is correctly installed. Relay module block diagram The DTA-Inverting and the ETA relay modules incorporate additional circuitry to monitor the integrity of the field wiring all the way to the final device, while also ensuring that it is impossible to accidentally trip the output while performing open and short circuit testing. Their design also provides diagnostics that the relay has switched the output on or off as required. Product Description Relay Modules for Fire and Gas Applications DeltaV SIS system can be used with auxiliary equipment to support fire and gas applications (in accordance with the DeltaV SIS Safety Manual) and other energize to actuate applications. The paired modules available for these applications include: Auxiliary Relay De-Energize to Actuate-Inverting (DTA-Inverting), 24 V DC module Auxiliary Relay Diode, 24 V DC module.

January 2013 Page 3 Item Input Power Field Power Isolation Discrete out load current Mounting Auxiliary Relay DTA-Inverting Module Specifications: 24 V DC ± 20% Contains integrated input OR-ing diodes for redundant 24 V DC inputs 5 A @ 24 V DC nominal (depends upon actuator used) Power input and logic solvers must be connected to a common ground 430 Ω, 55 ma @ 24 V DC input voltage DIN rail-mounted Top view of the Auxiliary Relay DTA-Inverting Module Bottom view of the Auxiliary Relay DTA-Inverting Module (showing the connectors)

January 2013 Page 4 Relay Module for High-Current Applications DeltaV SIS system can be used with auxiliary equipment to support other applications. The paired modules available for other applications include: Auxiliary Relay Energize to Actuate (ETA-Direct), 24 V DC module Auxiliary Relay Diode, 24 V DC module. Auxiliary Relay Energize to Actuate (ETA-Direct) The ETA-Direct relay module has a connection to a single discrete input and a single discrete output channel on a Logic Solver and a connection to a dual 24 V DC power supply. Two field terminals are used to connect to the diode module that is located next to the field actuator. The ETA Direct relay module de-energizes the field device when the Discrete Out is turned off. The ETA Direct relay module is paired with the Relay Diode module to enable the monitoring of the field wiring and the status of the relay. A switch on the Relay Diode module is used to change between energize to actuate and de-energize to actuate. The Auxiliary Relay DTA-Inverting module s LED shows the state of the relay coil and that power is correctly installed. The connectors on the Auxiliary Relay ETA-direct module are the same as those for the Auxiliary Relay DTA- Inverting module. Auxiliary Relay ETA-Direct Module Item Specifications: Input Power Field Power Isolation Discrete out load current Mounting 24 V DC ± 20% Contains integrated input OR-ing diodes for redundant 24 V DC inputs 5 A @ 24 V DC nominal (depends upon actuator used) Power input and logic solvers must be connected to a common ground 430 Ω, 55 ma @ 24 V DC input voltage DIN rail-mounted Auxiliary Relay Diode Module The Auxiliary Relay Diode Module must be paired with either of the Auxiliary Relay modules (ETA Direct or DTA- Inverting). Auxiliary Relay Diode Module Mode Selection Item Specifications: Switch selectable between ETA and DTA operation Mounting Per DIN 43729

January 2013 Page 5 Connectors and switch positions on the Relay Diode module Use the following table to match the application to the appropriate module. Matching the Application to the Appropriate Module Condition of final device in safe state Application Type Current rating of final device De-energized (off) De-energize-to-trip <= 500 ma Module None wire device to Digital Output channel on DeltaV SIS logic solver De-energized (off) De-energize-to-trip > 500 ma Energize to Actuate (ETA) Relay Energized (on) Energize-to-trip Any De-Energize to Actuate-Inverting (DTA- Inverting) Relay

January 2013 Page 6 Ordering Information Description Auxiliary Relay ETA-Direct Module Auxiliary Relay De-Energize to Actuate (DTA-Inverting), 24 V DC module Auxiliary Relay Diode, 24 V DC module VS6901 VS6902 VS6903 Model Number Prerequisites DeltaV v8.3 software or later. To locate a sales office near you, visit our website at: www.deltavsis.com Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 For large power, water, and wastewater applications contact Power and Water Solutions at: www.emersonprocess-powerwater.com Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East, Africa: 48.22.630.2443 North America, Latin America: +1 412.963.4000 Emerson Process Management 2013. All rights reserved. For Emerson Process Management trademarks and service marks, go to: http://www.emersonprocess.com/home/news/resources/marks.pdf. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. www.deltavsis.com