SA/4/10/EN Low Leakage Steel Door Type ST- TROX South Afria (Pty) Ltd. 10 Wigford Road Masons Mill Pietermaritzburg Tel. +27 (0) 98 1006 Fax. +27 (0) 98 1100 email : pmb@troxsa.o.za Website: www.troxsa.o.za
Contents Desription Desription 2 Constrution Standard Sizes Installation Details 5 Produt Range 6 Aessories Tehnial Data 7 Order Details 8 ST STV V ST-D STV-D -D V-D Low leakage steel doors are designed for use in air onditioning systems, plant rooms, filter plenums, air handling units et. If exposed to the weather the steel doors should be proteted with anti-orrosion paint. The stable onstrution guarantees a very low leakage even with high pressure differentials. Good sound insulation is also ahieved in the onstrution with additional aousti treatment (X versions). 2
Constrution Type ST STV V ST Double skinned door in galvanised sheet steel with rokwool insulation: door thikness d approx. 44 mm Installation frame (angled setion or U-hannel) with galvanised builders leats welded in position Double lever loking devies (2 off) dieast aluminium, enables operation from both sides APT rubber seal, temperature resistant up to 90 C Maximum pressure differential 1000 Pa (pressure should push the door against the frame); leakage 2 m /h As for type ST, but also with additional aousti treatment V As for type STV, but also with additional aousti treatment STV As for type ST, but: Reinfored door onstrution Maximum pressure differential 2000 Pa (pressure should push the door against the frame); leakage 4 m /h Type ST STV V Detail of Double Lever Loking Devie With angled setion installation frame e d a 5 b d H + a. 0/B + a. 0 d With U-hannel installation frame 5 (right hand opening shown) a. 20 a Door b Rokwool insulation Double lever loking devie - not removeable d Installation frame, angle setion or U-hannel e Seal
Constrution Type ST-D STV-D -D V-D ST-D Double skinned door of galvanised sheet steel with rokwool insulation Installation frame (angle setion or U-hannel) with srew-fixed entre mullion and galvanised builders leats welded in position Double lever loking devies (2 off per door) in dieast aluminium, enabling operation from both sides APT rubber seal, temperature-resistant up to 90 C Maximum pressure differential 1000 Pa (pressure should push the door against the frame); leakage 4 m /h -D As for type ST-D, but also with additional aousti treatment V-D As for type STV-D, but also with additional aousti treatment STV-D As for type ST-D, but: Reinfored door onstrution Maximum pressure differential 2000 Pa (pressure should push the door against the frame); leakage 8 m /h Type ST-D STV-D -D V-D a Door b Rokwool insulation Double lever loking devie d Installation frame, angle setion or U-hannel e Seal f Centre mullion Detail of Double Lever Loking Devie see page B/H e a b 80 f d a. 20 B + a. 0/H + a. 0 4
Standard Sizes Installation Details Standard Sizes Type B H Builders leats on in mm in mm B dimension H dimension ST 500 1500 STV 600 1600 600 1800 4 V 800 1800 4 940 1940 4 ST-D 1080 1500 4 STV-D 1280 1600 4 -D 1280 1800 1 5 V-D 1680 1800 5 1960 1940 5 Installation Details = = = H H + 20/B + 20 Builders leat a H/B Outside pressure pushing door against frame a b b H/B 200 Outside pressure pushing door against frame 200 Single door onstrution shown B Angle setion U-hannel For double door onstrution, 1 additional builders leat on the B dimension Type Installation frame ST STV ST-D STV-D Dimensions in mm V -D V-D Angle setion U- hannel a 45 45 b 45 45 5 5 a 115 or 240 b 50 5 5
Produt Range Angle setion installation Frame - single door - 45/45/5 Frame - double door - 50/50/5 Frame Constrution Complete with Code Night Lath Lok Z 01 * Glass Inspetion Port Z 02 * Pressure Relief Valve Z 0 * Basi Constrution Lok with Glass Inspetion Port Z 04 * Lok with Pressure Relieve Valve Z 05 * Glass Inspetion Port with Pressure Relief Valve Z 06 * Lok with Glass Inspetion Port and Pressure Relief Valve Z 07 * Padlok Faility (exludes padlok) Z 08 * U-hannel installation frame 115/50/4.5 1 U-hannel installation frame 240/50/4.5 15 Painted/Stainless Steel onstrution available on request. *Double doors shall have the seleted option on eah leaf. 6
R 70 60 * 50 2 1 db 40 V V 0 20 10 125 250 Hz 500 1000 2000 f Aessories Tehnial Data Nomenlature R in db: Sound redution index R W in db: Sound redution index rating f in Hz: Frequeny Type Graph R W in db V 1 4...46 D V-D 2 44...47 V (doors on both 58...61 sides of wall opening) Type V -D V-D R 70 60 50 db 40 0 V V * 2 1 Note: Before mortaring in plae, align door arefully; when the door is losed, the seal must be in ontat with the door frame all the way around. 20 10 125 250 Hz 500 1000 2000 f * Referene urve from DIN EN ISO 717 Arrangement of Aessories Type ST STV V Type ST-D STV-D -D V-D h i i g j g e H g j B right hand onstrution shown B Dim. in mm Type ST STV V ST-D STV-D -D V-D e H/2 g H/2 190 h 570 g Night Lath Lok i Glass inspetion port j Pressure relief valve 7
Order Details Order Code These odes do not need to be ompleted for standard produts / / / ST-R 500 x 1500 11 Z01 Type ST STV V ST-D STV-D -D V-D Sizes B x H in mm (see page 5) Constrution Right hand R Left hand L (only for ST STV V; if not speified, R is supplied) Right hand onstrution Aessories Z01 Z08 (see page 6) Left hand onstrution Installation Frame 0, 1, 15 (see page 6) (if not given 0 is supplied) Design hanges reser ved All rights reserved TROX South Afria (Pt y) Ltd Otober 2005 Speifiation Text Low leakage steel doors omprising: Double skinned door in formed galvanised sheet steel to DIN EN 10142; with insulation of non-flammable rokwool to DIN 4102 Installation frame with welded hinges and galvanised steel builders leats Double lever loking devies enalbes operation from both sides, in dieast aluminium Peripheral profiled rubber seal of APT, temperature resistant up to 90 C Installation frame: see data on pages 5 and 6 Aessories: see data on pages 6 and 7 Type: see data on pages and 4 Order Example Make: TROX Type: ST-R / 500 x 1500 / 0 / Z01 Qty: 4 8