Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Similar documents
Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Lumination TM LED Luminaire (IS Series)

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Horticulture Batten LED Luminaire

MOONRING 1.5 MOONRING 3

Wet Rated Batten LED Luminaire

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTIONS

WARNING / AVERTISSEMENT

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Lumination TM LED Luminaire LUR Series

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Installation Instructions CRAFT M/L

Lumination LED Luminaires

Installation Instruction

Installation Instructions

GETTING STARTED WITH IN-WALL DIMMER SWITCH

HBDBM High Bay Series

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

FINA SUSPENDED INSTALLATION INSTRUCTIONS

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

CFP-LED Contractor Select Flat Panel. Installation Instructions

MAXLITE RKT LED Retrofit Kit

VA-4233-AGx Series Electric Valve Actuators

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

High Bay Luminaire Series

EMERY SKY SUSPENDED LED LUMINAIRE

LAL SERIES LED LUMINAIRE

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Spun Bay Installation Standard Version (non dimmable), Hook Mount

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

NT-300 Series Single Circuit Track System & Accessories

General Installation Instructions LED

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

ZIP LIGHT LED LUMINAIRE

1Unpack fixture. Suspensions/canopies are ordered and

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

Installation Instructions

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

Lumination LED Luminaires

LIGHTPLANE 1 RECESSED - LP1R

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Installation Instructions

Installation Instructions

Installation Instructions

MODELS 2 & 4 Top Conduit Linears

Cable Cubby 1202 and 1402 Installation Guide

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Installation Instructions

VR44-MU-xxx-8yy-xxxxA

MODELS. 2 & 4 Low Profile Linears

Specification Grade Contemporary Wall Mount/Technical Installation Data

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work

TM-11x1 Series Room Temperature Module

ecolor Cove MX Powercore Premium interior linear LED cove and accent fixture with solid color light

LED IMPORTANT SAFETY INSTRUCTIONS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Evolve LED Roadway Lighting

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

VA-715x Electric Valve Actuator

TORi INSTRUCTION SHEET. Minimalist Linear Fixture T5/T5HO. CSS - Cable Suspended. 1. Cut cables to desired length - take care not to fray cable ends.

LOOP 65 Up 35 Dn LS1-A. Luminaire LOOP - 65 UP 35 DN LED (LS1-A) Type. Project. Product. Notes. Performance Summary OPTIONS

1000mA - 650mA Phase Dimmable LED Driver

Captivate Illuminated Mirror Light

Installation Instructions

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

BT300 Variable Frequency Drive Bypass

MaxLite StaxMax LED Flood Lights

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

VR22-MU-xxx-8yy-xxxxA

Service Manual. Frequency (Hz) Noise (sones) < <0.3

Cable Cubby 650 UT Installation Guide

Customer service: or Upper mounting ring. Canopy

VR44-MU-xxx-8yy-xxxxA

650mA Phase Dimmable LED Driver

DALI 650mA LED Driver

CLARA CLA SUSPENDED, WALL, SURFACE

Evolve LED Roadway Lighting

Cable Cubby 1200 and 1400 Installation Guide

Transcription:

GE Lighting Solutions Installation Guide Lumination TM LED Luminaires Suspended LED Fixture (Series EP14) Features Long life (50,000 hour rated life) 5 year warranty IP30 Dry location rated BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal. Properly ground electrical enclosure. RISK OF FIRE Follow all IEC and local codes. Use only UL or IEC approved wire for input/output connections. Minimum size 18 AWG (0.82mm 2 ). WARNING/AVERTISSEMENT RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l alimentation avant d inspecter, installer ou déplacer le luminaire. Assurez-vous de correctement mettre à la terre le boîtier d alimentation électrique. RISQUES D INCENDIE Respectez tous les codes IEC et codes locaux. N utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de connexion. Taille minimum 18 AWG (0.82mm 2 ). Save These Instructions Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. imagination at work

Define Distance Between Canopy Sets Single unit installation scenario: Canopy set 1179mm (46.4 in.) (distance between canopy sets) Luminaire Multiple units in series installation scenario: 1193mm (47 in.) 1207mm (47.5 in.) 1207mm (47.5 in.) 1207mm (47.5 in.) 1193mm (47 in.) 1st luminaire 2nd luminaire 3rd luminaire 4th luminaire 5th luminaire Distance between canopy sets for left and right luminaires = 1193mm (47 in.) Distance between canopy sets for luminaires in the middle = 1207mm (47.5 in.) Example: To install five units in series, the distance between canopy sets for the 1st (left) and 5th (right) luminaire is 1193mm (47 in.), and the distance between canopy sets for the 2nd, 3rd and 4th (middle) luminaires is 1207mm (47.5 in.).

Unit Installation To driver enclosure Junction box in ceiling Bracket bar 1 Carefully unpack unit from its packaging. Properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire. 2 Attach bracket bar to junction box in ceiling with two 8-32 (M4) screws. Repeat on other side. To driver enclosure Strain relief bushing Wires from luminaire Canopy (electrical) Stud Cable coupler Suspension cable 3 Connect the black (line) and white (neutral) wires from the luminaire to the matching-colored wires from the driver enclosure. Connect both green wires to the grounding screw. 4 Fit canopy over stud of bracket bar, then screw cable coupler onto stud. Squeeze tip to adjust Tie wrap 5 To adjust height and to level a fixture, squeeze the tip of the gripper and pull the suspension cable to the desired height. Clip the cable with cable cutters to finish the appearance. 6 Optional: For an improved appearance, electrical wire can be tie-wrapped to the suspension wire.

Optional Mounting Method - Connecting Suspended Fixtures in Series Canopy sets with power cable Canopy set without power cable 1 For multiple units installed in series, all canopy sets will have a power cable except the last canopy. Disconnect suspension wire Remove Y shape wires Y shape suspension wire Bracket 2nd luminaire 1st luminaire 2 On the 1st luminaire, disconnect the right-side suspension wire and Y shape suspension wire. Then on the 2nd luminaire, disassemble the left-side Y shape suspension wire (this one will not be used). 3 Attach a bracket to each end of the Y shape suspension wire using washer, spring washer and M8 nuts. Screw torque should be between 15.3±0.8kg f. Squeeze tip to adjust 4 Join 1st and 2nd luminaires together by fastening the brackets on the modified Y shape suspension wire from Step 9. Fasten brackets using four M8 screws. Screw torque should be between 15.3±0.8kg f. 5 Reattach suspension wire to Y shape suspension wire. To adjust height and to level a fixture, squeeze the tip of the gripper and pull the suspension cable to the desired height. Clip the cable with cable cutters to finish the appearance.

Electrical Connections Remove cover Install fittings 1/4-20 screws 1 Remove driver enclosure cover. Carefully remove knockout for AC line input wires. Install listed electrical fittings in the knockout holes for wire protection. 2 Install driver enclosure to a suitable structural member using two 1/4-20 screws. AC line From luminaire To dimming controller (optional) 3 Connect the black (line), white (neutral) and green 4 wires of the AC line to the terminal block. Next connect the red, blue and green wires of the luminaire to the terminal block. Replace electrical enclosure cover. Remove protective film from the face of the luminaire. Optional dimmer: When connecting dimming controller, wires must be run through a separate knockout hole equipped with cable gland suitable for 20mm hole and separated a minimum of 6.4mm (0.250 in.) from branch circuit wiring.

Maximum Driver Remote Mounting Distance Supply Wire Gauge Wire Length* 18 AWG (0.82 mm 2 ) 59.0 ft. (18 m) 16 AWG (1.31 mm 2 ) 98.4 ft. (30 m) 14 AWG (2.08 mm 2 ) 154.2 ft. (47 m) 12 AWG (3.31 mm 2 ) 249.3 ft. (76 m) * Includes fixture s 6.6 ft. (2.0 m) power cord Specifications Input Voltage (VAC) 120 277V Input Power (W) 55W Input Frequency (Hz) 50/60 Hz Power Factor > 0.9 THD < 20% Control 0-10V & DALI Ceilings Cable Suspension System Warranty 5 years Dimensions 47.5 in. x 11.8 in. x 1.38 in. (1206 mm x 299 mm x 35 mm) Light Fixture Weight 14.3 lbs. (6.5 kg) Environmental Operating Temperature Range -10 C to +40 C Environmental Humidity (non-condensing) 20 to 80% Non-condensing, dry location rated Environmental Storage Temperature Range -40 C to +60 C IP Rating IP30 Conforms to the following standards: GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com 1-8 8 8-6 9-4 3-5 3 3 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Lumination is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. IND027-112712