Light Source User Guide

Similar documents
Light Source User Guide

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

P/N Wheeler. user manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Measurements are expressed in millimeters.

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LED Twister II. User manual UK Version 1.0

FiberSource Q150. user manual P/N

Mania EF1 user manual

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

User Guide for Logo Projector

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

LED Pinspot 2. Snapshot. User Manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

LED Pinspot 2. Snapshot. User Manual

FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Sirius Illuminator Range

innovations in battery charging

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

QTFX-F1, QTFX-F2 FLAME EFFECT

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

X100P Load Bank. Read all instructions before using the load bank. Contents

12 amp RMS Battery Charger

USER MANUAL LUX-LD30W LED MOVING HEAD

Mania DC3 user manual

Ego 01 Ego 02 Ego 03 Logo Projector user manual

FL 150 XT-2 B, F, and C

INSTALLATION INSTRUCTIONS

USER MANUAL PAR56 LED PAR CANS

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

CH-158 Color Bank 8 USER MANUAL

XS400 Load Bank. Read all instructions before using the load bank. Contents

Switching DC Power Supply

Operations and Service Manual. X30208 Load Bank

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

OWNER S MANUAL Please read this manual before operating your power supply

FL B. Halogen light generator for Fibre optic lighting systems

INSTALLATION INSTRUCTIONS

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Operating instructions Bedienungsanleitung Mode d emploi

Navigator ORDERCODE 40410

12VDC TO 230VAC INVERTERS

INSTALLATION INSTRUCTIONS

1RECHARGEABLE APPLIANCES

Instruction/Installation Manual

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

Operating instructions EWB 200

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

INSTALLATION INSTRUCTIONS

Bubble King. User Manual

User Manual Rittal PMC UPS 6kVA

Operating Manual. Follow all safety precautions!

STATIC DAYLIGHT PAR 575 VF

Inverter User Manual

HyperFlex 12G.

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Snapshot. Hurricane 1300 USER MANUAL F-1300

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

Bubble Machine. User Manual

Compact LED profile with zoom

Car Battery Charger Instructions for Use

AvaLight-DHS Deuterium Halogen Light Source Operating manual

Snapshot. User Manual BOB LED

58kHz AM Deactivator DB104 Instruction Manual V1.0

Matala. VersiFlow Series. Instruction and Maintenance Manual

SZ2-ILA INSTRUCTIONS TRANSMITTED ILLUMINATION ATTACHMENT SZ-ADD SZ-POL-2 SZH-CLJ. Optional Modules

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Product Data Sheet : LIGHTHAWK 6 CELL

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

Triple Output Power Supply

EC200 ELECTRONIC CONTROL SYSTEM

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

OWNER S MANUAL POWER INVERTER

V1606 3U RACK ENCLOSURE

HPP1 MK6-15A/20A R00 Owners Manual

GP12 TECHNICAL MANUAL

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Operating Manual. Follow all safety precautions!

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

MOVING HEAD. User manual CAUTION!

LED Recessed Troffer Retrofit Kit

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Installation Instructions

HPNLS-HO. Installation Manual

Operations and Service Manual. XE400D-SB Load Bank

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

LEAD ACID BATTERY CHARGER

Operating Instruction for Downlights

Transcription:

Light Source User Guide Compact Light Source Range Models covered by this manual: UFO 70/150 CG Glass, White Light - 240V UFO 70/150 CP Plastic, White Light - 240V UFO 70/150 CGC Glass, Colour Wheel (continuous) - 240V UFO 70/150 CPC Plastic, Colour Wheel (continuous) - 240V UFO 70/150 CGS Glass, Colour Wheel (switch on box) - 240V UFO 70/150 CPS Plastic, Colour Wheel (switch on box) - 240V UFO 70/150 CGCF Glass, Colour Wheel (separate feed) - 240V UFO 70/150 CPCF Plastic, Colour Wheel (separate feed) - 240V Issue 2 Revised: 10092013 Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel: +44 (0)1890 883416 Fax: +44 (0)1890 883062 www.fibreopticlighting.com

INTRODUCTION Thank you for purchasing this UFO Light Source. Please read these instructions fully before connecting your unit to the electrical supply, and keep them for future reference. The UFO Compact light sources are a range of low profile light sources which use either 70W or 150W metal halide discharge lamps to give much greater brightness than those powered by halogen lamps. These models have a fast re-lamping feature (the lamp is mounted on a pull out hatch at the rear) and can be fitted with a combination of colour, twinkle or dimmer wheels for providing lighting effects. We do not recommend that the light source be left on for 24 hours a day, 7 days a week as lamp life will be impaired. A switch off of 30mins per day is recommended. METAL HALIDE LAMPS CANNOT BE CONNECTED TO A MAINS DIMMER OR A REDUCED SUPPLY VOLTAGE. THIS WILL RESULT IN DAMAGE TO THE LAMP AND AND THE ELECTRONIC BALLAST. IMPORTANT THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED Do not operate without complete lamp enclosure in place or if lens is damaged. KEEP HARNESS IN PLACE WHEN IN OPERATION. CAUTION: Hot surface. Keep away from curtains and other combustible materials. WARNING: RISK OF FIRE/INJURY TO PERSONS. Keep away from combustibles. Unplug to change lamp. Do not touch lamp. WARNING: RISK OF FIRE. Do not place lamp where the overhead surface is closer than 0.2m to the light source. 1 Compact Light Source Range

IMPORTANT SAFETY INFORMATION INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted Lamp is HOT: WARNING To reduce the risk of FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS: 1. Unplug and allow to cool before replacing lamp. 2. Lamp gets HOT quickly! Only contact plug when turning on. 3. Do not touch hot lens, guard, or enclosure. 4. Do not remain in light if skin feels warm. 5. Do not look directly at lighted lamp. 6. Keep lamp away from materials that may burn. 7. Use only with the correct lamp wattage as detailed on the serial label. Failure to adhere to this will cause damage to the unit. 8. Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp. 9. Do not operate product with missing or damaged guard, lamp containme barrier, lens or fibre-optic harness. 10. WARNING - Lamp types are matched to the ballast and different wattages/types cannot be used. SAVE THESE INSTRUCTIONS Always disconnect the unit from the power supply before opening or attempting to perform any work on it. UNIT MAY GET HOT - always allow unit to cool down before handling or moving it. Do not touch or attempt to remove the lamp while it is hot. Ensure that the power supply is correct for the unit before powering it up. Always ensure that the unit is properly EARTHED. Do not expose the unit to rain or moisture. Keep away from all combustible materials. Never attempt to tamper with the wiring or other internal components. Keep the unit away from gas, oil and any other flammable or explosive materials. Universal Fibre Optics 2

LIGHTSOURCE LAYOUT Item Description 1 Power LED 2 Mains input socket & fuse holder 3 Blanking plate or colour wheel switch depending on specification 4 Motor cover (decorative units only) 5 Fibre port connector 6 Cooling fan 7 Lamp access hatch 8 Securing holes (keyhole slots) 3 Compact Light Source Range

INSTALLATION GUIDE In order for the Compact light source to function safely and efficiently it must be installed according to this user manual. Please read all sections thoroughly before switching on the light source. POWER SUPPLY REQUIREMENTS Before plugging in the unit, please make sure that the supply is correct. Failure to do so could cause the unit to malfunction. The unit requires a 240VAC 50Hz supply and it MUST BE EARTHED. The light source units are provided with a cordset fitted with a standard 3-pin plug. POSITIONING THE UNIT The light source can be mounted horizontally, vertically or upside-down on any flat surface. Keyhole slots are provided on the base of the unit to allow for securing to a surface. The light source is only suitable for use in a dry area. If the unit is being mounted at a higher than the ground level, block access below the work area before installing. Verify that any screws or bolts can safely bear the weight of the light source. Universal Fibre Optics 4

INSTALLATION GUIDE (Continued) Verify that the supporting structure can safely bear the weight of all installed units, cables and any other equipment. The minimum thickness of the mounting surface must be no less than 19mm. For horizontal mounting, it is recommended that the lightsource is secured to a solid surface using 4 x M4 or M5 screws or bolts and the keyhole slots. This is particularly important if the lightsource location is not at ground floor level. To mount the light source vertically, first securely install 4 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots. The light source can then be mounted onto them and slid into position. The bolts or screws MUST then be fully tightened. To mount the light source under a surface, first securely install 4 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots. The light source can then be mounted onto them and slid into position. The bolts or screws MUST then be fully tightened. CLEARANCE / VENTILATION It is imperative that a gap of 200mm (8") or more is left around the unit. This is to allow air to circulate and prevent overheating. The location must have free ventilation. 5 Compact Light Source Range

INSTALLATION GUIDE (Continued) CONNECTION There are 2 main connections required - the fibre port and the mains power supply. On separate feed units, there are two power connections. Connect and secure the fibre optic connector to the fibre port before connecting the electrical supply. Never run the light source with the fibre connector unplugged. OPERATION Switch on the power to the light source and it will start up automatically. Light will be output from the port connector and throughout the fibre harness. If no light is produced, please consult the TROUBLESHOOTING section in this manual WHEEL CONTROL Decorative models of the Compact are available with a number of different colourwheel control options. The control system available will depend on the exact model specified. Continuous rotation - the wheel rotates continuously and cannot be stopped. White light only output is available by removing the wheel, as detailed on page 8 of this manual. Separate feed - the wheel is controlled by a secondary mains electrical feed. It can be started and stopped on any colour by simply switching the power off. Switch control - the wheel can be started and stopped by using a switch built into the back of the unit. Universal Fibre Optics 6

MAINTENANCE LAMP REPLACEMENT - Recommend Lamp change every 12 months for Metal Halide Lamps should not be run to the end of their life. 1) Unplug unit from electrical supply and allow to cool. 2) On the rear of the unit, unscrew the two knurled securing nuts (A) which hold the lamp holder in position. 3) Use the handle (B) to withdraw the lamp holder(c) from the light source. 4) Unplug the old lamp from its ceramic holder. 5) Plug the new lamp into the holder, making sure that you use a bulb of the same specification as to that which was removed. Also make sure not to touch the glass part of the lamp. 6) Slide the lamp holder plate back into position and tighten the two retaining nuts. FUSE REPLACEMENT 1) Unplug unit from electrical supply and allow to cool. 2) The fuse is located in a drawer under the mains input connector. There is also a spare fuse located in this drawer. 3) Open the fuse drawer. 4) Withdraw fuse from its holder. 5) Replace with identically specified fuse - see specification table in this manual. 6) Close the fuse drawer and power up the light source. 7 Compact Light Source Range

MAINTENANCE (Continued) CLEANING THE UNIT Disconnect unit from power supply and allow to cool before attempting any cleaning of the unit. A visual check of the unit should be completed every 12 months. However cleaning should take place as and when required. The body of the unit can be cleaned with a soft, damp cloth - do not use any abrasives on the unit. The fans and vents should be kept clear by periodically blowing them out with compressed air. Glass filter to be cleaned with soap and water then dried. Please note that a record of all maintenance MUST be kept in the table below, indicating what maintenance was undertaken and when. This must be DATED for warranty purposes. Date Maintenance Undertaken Universal Fibre Optics 8

TROUBLESHOOTING Problem Probable cause(s) Remedy Unit is completely dead - Lamp and LED power indicator are not illuminated Main fuse blown No power to unit Lamp blown Check and replace fuse. Check that power is switched on and power supply is plugged in. Replace lamp LED power indicator & fan are on, but no light is output Thermal switch activated Lamp wires are not connected Allow unit to cool for 5 to 10 minutes and investigate reason for overheating Check plug connection - ensure lamp is properly seated in its holder and the pins are fully mated Poor light output Lamp needs replacing Unit needs cleaning Incorrect power supply Replace lamp Clean glass lens with soap and water and then dry Ensure power supply is 240VAC 50Hz Fibre port connector not plugged in correctly Ensure fibre port connector is plugged in correctly, and that the screw is tightened up properly Lamp going on & off randomly Unit is overheating Allow unit to cool for 5 to 10 minutes and investigate reason for overheating Please complete troubleshooting procedures before returning unit to us for further investigation. 9 Compact Light Source Range

TECHNICAL SPECIFICATIONS Description 70W White Light 70W Decorative 150W White Light 150W Decorative Port connector size 30mm diameter 30mm diameter 30mm diameter 30mm diameter Fibre type Glass / polymer Glass / polymer Glass / polymer Glass / polymer Supply voltage 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz 240VAC 50Hz Lamp power 70W 70W 150W 150W Input power 114VA @ 240VAC 114VA @ 240VAC 180VA @ 240VAC 180VA @ 240VAC Start up current 0.25A @ 240VAC 0.25A @ 240VAC 0.3A @ 240VAC 0.3A @ 240VAC Running current 0.6A @ 240VAC 0.6A @ 240VAC 0.75A @240VAC 0.75A @240VAC Min. ambient temp. -20 C -20 C -20 C -20 C Max. ambient temp. 40 C 40 C 40 C 40 C Thermal protection Thermal switch Thermal switch Thermal switch Thermal switch Ballast type Electronic Electronic Electronic Electronic Fan type (polymer fibre) Papst 8550N Papst 8550N Papst 8550N Papst 8550N Fan type (glass fibre) Papst 8880N Papst 8880N Papst 8880N Papst 8880N Power cord IEC mains cable IEC mains cable IEC mains cable IEC mains cable Main fuse 4 Amp 4 Amp 4 Amp 4 Amp Lamp type Metal halide Metal halide Metal halide Metal halide Lamp model Philips CDM-T or CDM Philips CDM-T or CDM Philips CDM-SA/T or CDM *Lamp life c. 12000h c. 12000h c. 9000h (SA-T) c. 12000h (CDM) Lamp colour temp. 4200K (CDM-T) 3000K (CDM) Lamp CRI 92 (CDM-T) 84 (CDM) Acoustic rating (polymer fibre) 4200K (CDM-T) 3000K (CDM) 92 (CDM-T) 84 (CDM) 4200K (SA/T) 3000K (CDM) 95 (SA/T) 88 (CDM) Philips CDM-SA/T or CDM c. 9000h (SA-T) c. 12000h (CDM) 4200K (SA/T) 3000K (CDM) 95 (SA/T) 88 (CDM) 38.0dB(A) 38.0dB(A) 38.0dB(A) 38.0dB(A) Acoustic rating (glass fibre) 23.0dB(A) 23.0dB(A) 23.0dB(A) 23.0dB(A) Operating environment Indoor / dry Indoor / dry Indoor / dry Indoor / dry Protection rating IP20 IP20 IP20 IP20 Material Sheet steel Sheet steel Sheet steel Sheet steel Colour Black Black Black Black Size 288x250x100 mm 288x277x129 mm 288x250x100 mm 288x277x129 mm Weight 3.2kg 3.5kg 3.2kg 3.5kg * lamp life as stated by manufacturer in optimum conditions Universal Fibre Optics 10

Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel: +44 (0)1890 883416 Fax: +44 (0)1890 883062 www.fibreopticlighting.com