Solenoid Valve Installation Kit

Similar documents
Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

E-200 Module Service Kit

TCU Flushing Manifold and RTD Installation

Installing an H-200 Integral Right-Angle Module

Inverted High Pressure Fluid Filters

Pro-Swirl Manifold Air Heater

Spray Pressure Control Manifold

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

E-200 O-rings Service Kit

Spray Pressure Control Manifold

Series 3900/M Pump Retrofit Kit

0 900 psi Pressure-Reducing Diaphragm Regulator

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Miniature Soft Seat Fluid Pressure Regulator

Two Component Meter Cylinder Assembly Replacement

Rhino SD/XD Depressurization Modules for Electric Changeover Controls

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

Installation Instructions for Series 3100V Low Level Indicator

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

5000 Gerotor Pump Service Instructions

Paint/Solvent/Dump Valve and Flow-Through Valve

Inverted Dual High-Pressure Fluid Filter Assemblies

Fluidizing Pickup Tube Kits

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installing the Low Level Indicator (P/N or P/N )

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

Blow Off Valve Retrofit Kit

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

0-800 psi Carbide Seat Fluid Pressure Regulator

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Description. Rhino EFD Bulk Unloader Packages

Hard Seat Fluid Pressure Regulator

Standard and Conical AN Series Air Spray Nozzles

0-500 PSI Soft Seat Fluid Pressure Regulator

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

Soft Seat Fluid Pressure Regulator

8. Illustrated Parts Lists

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

One-Gun Add-On Kit For Smart-Coat Controllers

Air Spray Proportioning Valve

Back Pressure Regulator

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Mobile Powder Spray System Dolly with Hopper

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Auto-Flo Air-Assist Automatic Dispensing Valve

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Upgrading the Sure Coat Modular Gun Control System

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Prodigy HDLV Manual System Installation Instructions

8. Illustrated Parts Lists

Preventive Maintenance for Pail Melters

Rhino VE Follower Modules

Electric Vibratory Box Feeder Retrofit Kit

Pattern Air Control Kit (PACK)

8. Illustrated Parts Lists

11-1 Electrical System NOTE: Table of Contents Electrical System

Installing the Integral Platen Blow Off Valve

Prodigy Mobile Box Unloader System

SP30 10:1 Piston Pump

CoolWave 2 Phase Control Board and Cable Replacement Kit

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor

EP-2 Si Three-Piston Pump

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Description. Rhino SD2/XD2 Type-H Control Modules. S 55-Gallon Drum with Pneumatic Changeover S 55-Gallon Drum with Electric Changeover

Repair. Description. Rhino SD2/XD2 Drum/Pail Level Indicators

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Series 3000V Low Level Indicator

55-Gallon Powder Drum Truck

Encore Manual Powder Spray Gun Trigger Switch Replacement

Model AD-29A Automatic Air Spray Gun and Can Marking System

Sure Coat 90 Degree Spray Extension

TCU Static Mixer Installation

Description. Rhino SD2/XD2 Follower Modules

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

EP-2 Three-Piston Pump

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Description. Rhino SD2/XD2 Follower Modules

Nylon Fluid Regulators

Iso-Flo Coupling Repair

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Circulation Kits for CP Pumps

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

NRPS-100 Rotary Sieve

Adjustment. Description. Installation. Rhino SD/XD Pump Overlap Time-Delay Module

Prodigy to Encore HD Manual Powder Spray System Upgrade Kit

Installation, Operation and Maintenance Manual

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Mandatory X Information Recommended Change. Series/Parts Affected: LS40D, LS40TD, LS50TD and LS60TD Concrete Pumps

Lube Level Maintainer

Pneumatic Division North America Richland, MI 49083

Installation for Dodge Challenger & Charger HellCat PN s , , , , , , ,

PARTS LIST FOR WLP-40-0M10 WATER RECYCLING TREATMENT SYSTEM

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

Transcription:

Instruction Sheet P/N 7 5A Solenoid Valve Installation Kit WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.. Introduction WARNING: Risk of burns! The spool in a 4-way piloted valve may change position during shipment. However, the first time the valve is pressurized, the spool will return to the correct position. Do not guess which valve ports to plug. Doing so can create a normally open gun. Follow the procedures in this instruction sheet to correctly plug and install a 4-way piloted valve for use as a -way valve. When installed correctly, Nordson 5-ported, 4-way piloted solenoid valves can be used as normally closed -way valves. This instruction sheet contains the procedure for installing a 4-way valve for use as a normally closed -way valve and for connecting the valve to a power supply/timer. This instruction sheet also contains the procedure for installing a quick-disconnect fitting that allows easy installation and removal of solenoid valves. A solenoid valve may be either a Series 400 valve or a Series 800 valve. An installation kit must be ordered separately for each type of valve. Refer to Parts at the end of this instruction sheet for the kit part numbers. Be sure to use the appropriate procedure in this instruction sheet for the type of solenoid valve you are installing. The completed installation may be described as a 5-ported, 4-way solenoid valve operating as a -way valve. The input is through port and the output is through port.. Solenoid Valve Installation Use the following procedures to install a 5-ported, 4-way piloted solenoid valve for use as a normally closed -way valve, to install a quick-disconnect fitting (if desired), and to connect a solenoid valve to a power supply/timer.

Solenoid Valve Installation Kit Preparing for Installation Complete this procedure before installing a solenoid valve. WARNING: System or material pressurized. Relieve pressure. Failure to observe may result in serious burns.. Relieve hydraulic pressure by following the instructions in the applicator manual. WARNING: Risk of electrical shock. Disconnect equipment from line voltage. Failure to observe may result in equipment damage, personal injury, or death.. Turn off the applicator; then disconnect and lock out electrical power to the applicator. Installing a Series 400 Valve Use this procedure to install a Series 400 solenoid valve. WARNING: Risk of personal injury. If plugged or installed incorrectly, a solenoid valve will operate as normally open, which means the gun to which the valve is attached will turn on and stay on until the air supply is interrupted at the source. Be sure to properly plug and install solenoid valves. NOTE: See Figure when installing a Series 400 solenoid valve.. Install the / 8 NPT pipe plug (item 4) in port 5.. Install the / 8 NPT silencer (item ) in port.. Install the / 4 NPT pipe plug (item 5) in port 4. 4. Install the / 4 to / 8 NPT bushing (item 7) in port.

Solenoid Valve Installation Kit NOTE: If desired, you can install a quick-disconnect fitting between the valve and the bushing. The quick-disconnect fitting allows easy installation and removal of solenoid valves. Refer to Parts for the quick-disconnect kit part number. Refer to Installing a Quick-Disconnect Fitting to install the quick-disconnect fitting. 5. Connect the / 8 NPT pipe nipple (item 6) to the bushing installed in port. 6. Connect an air supply line to port. NOTE: The boxed numbers in the figure represent the valve port numbers. 4 5 4 5 7 6 46040 Fig. Installing a Series 400 Solenoid Valve. Terminal block housing 5. / 4 NPT pipe plug (port 4). Silencer (port ) 6. Pipe nipple. Air inlet (port ) 7. Bushing (port ) 4. / 8 NPT pipe plug (port 5) 7. Connect the other end of the pipe nipple to the gun s air inlet port.

4 Solenoid Valve Installation Kit Installing a Series 800 Valve Use this procedure to install a Series 800 valve. WARNING: Risk of personal injury. If plugged or installed incorrectly, a solenoid valve will operate as normally open, which means the gun to which the valve is attached will turn on and stay on until the air supply is interrupted at the source. Be sure to properly plug and install solenoid valves. NOTE: See Figure when installing a Series 800 solenoid valve.. Install the / 4 NPT pipe plug (item ) in port 5.. Install the / 4 NPT silencer (item 4) in port 4.. Install the / 4 NPT pipe plug (item 7) in port. 4. Install the / 4 to / 8 NPT bushing (item 5) in port. NOTE: If desired, you can install a quick-disconnect fitting between the valve and the bushing. The quick-disconnect fitting allows easy installation and removal of solenoid valves. Refer to Parts for the quick-disconnect kit part number. Refer to Installing a Quick-Disconnect Fitting to install the quick-disconnect fitting. 5. Connect a / 8 NPT pipe nipple (item 6) to the bushing installed in port.

Solenoid Valve Installation Kit 5 6. Connect an air supply line to port. NOTE: The boxed numbers in the figure represent the valve port numbers. 4 4 5 7 5 6 4607 Fig. Installing a Series 800 Solenoid Valve. Terminal block housing 5. Bushing (port ). / 4 NPT pipe plug (port 5) 6. Pipe nipple. Air inlet (port ) 7. / 4 NPT pipe plug (port ) 4. Silencer (port 4) 7. Connect the other end of the pipe nipple to the gun s air inlet port.

6 Solenoid Valve Installation Kit Installing a Quick-Disconnect Fitting If you wish to install a quick-disconnect fitting to allow easy installation and removal of a solenoid valve, order a quick-disconnect kit and complete this procedure. Refer to Parts for the quick-disconnect kit part number.. Disconnect the bushing and pipe nipple from the solenoid valve (port ).. Install the / 4 NPT quick-disconnect male nipple in port.. Install the / 4 NPT female coupler on the bushing and pipe nipple. Tighten the coupler. 4. Connect the female coupler to the quick-disconnect nipple. These parts snap together. ÎÎÎ 4604 Fig. Installing a Quick-Disconnect Fitting. Quick-disconnect male nipple. Bushing and pipe nipple. Female coupler

Solenoid Valve Installation Kit 7 Connecting a Solenoid Valve to a Power Supply/Timer Follow this procedure to connect a solenoid valve to a power supply/timer after the valve is installed on a gun. WARNING: Risk of electrical shock. Disconnect equipment from the line voltage.. Disconnect and lock out electrical power to the power supply/timer.. Remove the screw that secures the solenoid valve s terminal block and terminal block housing to the valve (see item in Figures or ). NOTE: The terminal block housing is the clear plastic piece with an mpm embossed on it.. Unplug the terminal block housing from the solenoid valve. Save the rubber washer. CAUTION: Risk of equipment damage. When removing the terminal block from the housing, do not attempt to pry the plug out of the housing from the plug face. Doing so can damage the prongs. Use the tool to press gently on the side of a prong, as shown in Figure 4. 4. Use an appropriate tool to push the terminal block out of the housing as shown in Figure 4. Press the tool gently against the edge of one of the prongs. Do not attempt to pry the plug out of the housing from the plug face. 4608 Fig. 4 Removing the Terminal Block from the Housing

8 Solenoid Valve Installation Kit CAUTION: A solenoid valve can be damaged if its voltage rating does not match the output voltage from the power supply/timer. Make sure the ratings match. 5. Thread two 8 AWG solid wires and a ground wire from the power supply/timer through the strain relief in the terminal block housing. 6. Loosen the screws for terminal blocks and ; then insert the two 8 AWG wires into the terminals and tighten the screws. NOTE: It does not matter which wire is connected to which terminal because the terminals are not polarity-sensitive. 7. Loosen the screw for the ground wire; then insert the ground wire and tighten the screw. 8. Snap the terminal block back into its housing. 9. Align the rubber washer on the terminal block housing; then plug the terminal block housing into the solenoid valve. CAUTION: Risk of equipment damage. Do not overtighten the securing screw in the following step. Overtightening the screw can break the terminal block housing. 0. Use the securing screw removed earlier to secure the terminal block housing to the solenoid valve.

Solenoid Valve Installation Kit 9. Parts To order parts, call the Nordson Customer Service Center or contact your local Nordson representative. Use the following parts lists to describe and locate parts correctly. Series 400 Solenoid Valves and Installation Kit The following parts list includes part numbers for Series 400 solenoid valves and the valve installation kit, which must be ordered separately. Item Part Description Quantity Note 0 00 Solenoid valve, 0.88 Cv, 4 Vdc, / 4 NPT, quick-disconnect (QD) w/light (LED), piloted 0 0 Solenoid valve, 0.88 Cv, 4 Vdc, / 4 NPT, QD, piloted 0 0 Solenoid valve, 0.88 Cv, 4 Vdc, / 4 NPT, QD w/light, water-wash, piloted 0 04 Solenoid valve, 0.88 Cv, 0 Vac, / 4 NPT, QD, piloted 60 Installation kit, Series 400 solenoid valves A 97 40 Pipe plug, / 8 NPT 66 Silencer, air, / 8 NPT 4 97 7 Bushing, pipe, hydraulic, / 4 NPT x / 8 NPT 5 97 4 Pipe plug, / 4 NPT NOTE A: This installation kit must be ordered separately. 5 4 4609 Fig. 5 Series 400 Solenoid Valve and Installation Kit Parts

0 Solenoid Valve Installation Kit Series 800 Solenoid Valves and Installation Kit The following parts list includes part numbers for Series 800 solenoid valves and the valve installation kit, which must be ordered separately. Item Part Description Quantity Note 0 05 Solenoid valve,. Cv, 4 Vdc, / 4 NPT, QD, piloted 0 06 Solenoid valve,. Cv, 4 Vdc, / 4 NPT, QD w/light, piloted 6 Installation kit, Series 800 solenoid valve A 97 4 Plug, pipe, socket, flush, / 4 NPT 67 Silencer, / 4 NPT 4 97 7 Bushing, pipe, hydraulic, / 4 NPT x / 8 NPT NOTE A: This installation kit must be ordered separately. 4 4606 Fig. 6 Series 800 Solenoid Valve and Installation Kit Parts

Solenoid Valve Installation Kit Quick-Disconnect Kit (Optional) Item Part Description Quantity Note 6 Quick-disconnect kit, / 4 NPT 68 Nipple, / 4 NPT, quick-disconnect, male 7 7 Coupler, / 4 NPT, Series 50, female ÎÎ Î ÎÎÎÎ 4605 Fig. 7 Quick-Disconnect Kit Parts

Solenoid Valve Installation Kit Original copyright date 998. Nordson and the Nordson logo are registered trademarks of Nordson Corporation.